Environmental Health & Safety

Similar documents
CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Gas Station & C Store SECTION CWM Job No

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

FIRE SUPPRESSION SPRINKLER SYSTEM

CITY OF PASADENA FIRE DEPARTMENT

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

SECTION FIRE-SUPPRESSION STANDPIPES

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

A. All Fire Suppression System design and installation shall comply with the most current and adopted version of NFPA 13.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

ADDENDUM NO. 3 March 19, 2018

SECTION FIRE PROTECTION

B. Related Sections: The following Sections contain requirements that relate to this Section.

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

New Construction Fire Inspection Process

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY-PIPE SPRINKLER SYSTEMS

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

DIVISION 21 - FIRE SUPPRESSION

DIVISION 21 - FIRE SUPPRESSION

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

SECTION SPRINKLER SYSTEMS

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

A. This section includes design and performance information for fire protection and suppression systems.

SECTION WET FIRE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

SECTION DRY-PIPE FIRE-SUPPRESSION SPRINKLERS

SECTION WET-PIPE FIRE-SUPPRESSION SPRINKLERS

City of Vista Fire Department

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY-PIPE SPRINKLER SYSTEMS

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

SPRINKLERS TABLE OF CONTENTS

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

FIRE PROTECTION BASIC MATERIALS AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

2. Welding Materials and Procedures shall conform to the ASME Code.

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

DIVISION 21: FIRE SUPPRESSION WATER BASED FIRE SUPRESSION SYSTEMS

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SECTION SPRINKLER SYSTEMS

DIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS

Design & Construction Standards, Revised January

B. Section Identification for Fire Suppression Piping and Equipment.

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

SECTION ADDENDUM NO. 1 FIRE SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION WET-PIPE SPRINKLER SYSTEMS

FIRE SPRINKLER SYSTEMS POLICY

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

DIVISION 21 FIRE SUPPRESSION

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Annual Water-Based Fire Protection Systems Inspection

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

FIRE SPRINKLER SYSTEMS POLICY

SECTION FIRE-SUPPRESSION SYSTEMS

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION FIRE SUPPRESSION SYSTEMS

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

DESIGN & CONSTRUCTION GUIDELINES

SECTION FIRE PROTECTION

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

micromatic Standard response Horizontal Sidewall sprinkler

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Western Michigan University Facilities Management Engineering Division

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

SECTION PREACTION SPRINKLER SYSTEMS

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

DISCONTINUED PRODUCT

Orange Township Fire Department Fire Prevention Bureau

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

standard response dry horizontal sidewall sprinklers

Transcription:

Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu Reviewed and Revised September 2017

Status Contact(s) Implementation Date Comments Gerald Petre, EHS June 2016 Review and Update Gerald Petre, EHS September 2017 Review and Update 1

General Intent of Document The information included in this section is intended to identify the SPECIFIC ITEMS required by Oklahoma State University in the design and construction of facilities on the campus. Items of "normal, code, industry or standard construction practice" are not included in this section. Contractor Qualifications / Requirements A minimum of five years specialized experience in sprinkler system installation is required. Project foremen shall have a minimum of three years of experience. Shop drawings shall be submitted to Long Range Facilities Planning or Facilities Management. Long Range Facilities Planning or Facilities Management shall transmit the shop drawings to a representative of Environmental Health and Safety for approval prior to installation. Design Criteria Sprinkler systems shall be designed to a minimum category of "Ordinary Hazard I"; light hazard systems are not permitted in OSU buildings. 2

Materials Above ground piping All above ground piping shall be Schedule 40 black pipe without reducing bushings. No CPVC piping or fittings will be allowed. Sprinklers Sprinklers exposed to public view shall be chrome plated semi-recessed type - Star Sprinkler Corp. or approved equal. Flexible sprinkler assemblies shall consist of wire braded hose only and shall be UL listed and FM approved. The flexible metal units are not authorized. All sprinkler heads shall be installed in the center of ceiling tiles. Spare Sprinkler Heads Six spare sprinkler heads for each temperature and style used and a sprinkler wrench for each type head shall be provided inside a metal box installed adjacent to the main sprinkler valve in accessible location not more than 5 1/2 feet above floor level. A list of sprinklers installed shall be posted in the sprinkler cabinet; list shall include manufacturer, model, orifice, deflector type thermal sensitivity, pressure rating, and identify what area of the building that each different sprinkler head was installed in. Valve Cabinets Valve cabinets shall be Potter Roemer Series 1800, or approved equal, steel with white prime coat finish, full recessed type, with wire glass door. Hose Valves Hose valves shall be Potter - Roemer, Elkhart Brass, or approved equal, single 2-1/2" polished chrome plated hose valve with 2-1/2" to 1-1/2" adapter with 1-1/2" cap and chain. The 2-1/2" Valve and adapter shall be provided with National Standard Hose Threads. Turn outlet to corridor and cover any exposed pipe with chrome sleeve. A 1" minimum clearance between hand wheel and cabinet is required. Flow Switches The Flow switches shall be Potter Electric Signal Co. Model VSR series. NO SUBSTITUTES. All flow switches shall be set with a time delay between 45 and 60 seconds. Label all test valves with a sign that says "Test Valve - Keep Closed" in white letters on a red background. All test valves shall drain to the outside of the building unless otherwise approved by the AHJ. 3

Exterior Fire Department Connection (FDC) The FDC shall be a sidewall or flush mount wall type, installed 3' - 0" to 4'- 0" above exterior grade, and polished chrome plated, escutcheon plate with "Automatic Sprinklers" cast in plate, individual clappers on each inlet connection. Each inlet shall have female switch with pin lugs, National Standard Hose threads, gasket, and KNOX-type cap. Piping shall be pitched to automatic ball drop inside building or to approved exterior concrete valve pit with access cover. There shall be a fire hydrant located within 150 feet of the FDC and shall be on the same side of the road as the FDC. Locking Fire Department Connection Caps A KNOX locking cap shall be required on all fire department connections for water-based fire protection systems. All KNOX caps shall be a bright stainless steel or polished chrome-like stainless steel finish. All KNOX locking caps shall be keyed to the current Knox key wrenches for the local fire department having jurisdiction. Control valves All control valves shall be Stockholm, Traverse City, or approved equal, 175 lbs. test, crank type with butterfly valves, indicator, with tamper switch and lockable in the open position with a padlock. Exterior Post Indicator Valve (PIV) The PIV shall be Demco, Incorporated, or approved equal, painted with two coats of Rust- Oleum No. 1565, International Red, Quick Dry Gloss. NO SUBSTITUTES. PIV shall be installed so the top of the post is 32 in. to 40 in. above final grade. The PIV Electrical Supervisory Switch The PIV electrical supervisory switch shall be a Potter Electric Signal Co., Model PIVS- U. NO SUBSTITUTES, and switch shall be installed on post indicator and control valves so that a supervisory signal will be registered on designated circuit of fire alarm system if valve is closed more than 1-1/2 turns from full open position. The switch shall be wired so when switch is in trouble position, it will not prevent sounding of fire alarm on circuit. If the main sprinkler riser can be DIRECTLY accessed from the exterior of the building, the PIV may be eliminated with the AHJ s approval. Water Flow Alarm An electronic horn/strobe shall be installed on the exterior of the building above the FDC in a location approved by the AHJ. Auxiliary / Inspectors Test Drains All auxiliary and inspectors test drains shall be piped to the exterior of the building. Hose bibs are not allowed. 4

Installation and Acceptance System shall be zoned into a minimum of two zones per floor with sectional valves, water flow switches, and tamper switches. Valves shall be capable of locking in open position. Exceptions shall be approved by the AHJ. ALL CONTROL VALVES AND FLOW SWITCHES SHALL BE INSTALLED IN AN EASILY ACCESSIBLE LOCATION BETWEEN 4 AND 6 FEET ABOVE FINISHED FLOOR. No sprinkler heads or sprinkler piping shall be installed in or routed through designated IT spaces. Underground piping shall be inspected for compliance by representatives of Long Range Facilities Planning, Facilities Management and Environmental Health and Safety being covered. Underground piping shall be thoroughly flushed in accordance with NFPA 13 section 10.10.2.1, before piping is connected to building sprinkler system. Flushing shall be witnessed by representatives of Long Range Facilities Planning, Facilities Management and Environmental Health and Safety. Provide 48 hours prior notice. Prior to placing piping in service, flush entire system as required; removing foreign substances. Continue flushing until water is clear, and check to ensure that debris has not clogged sprinklers. This flushing shall be witnessed by representatives of Long Range Facilities Planning, Facilities Management and Environmental Health and Safety. Provide 48 hours prior notice. Test entire system hydrostatically at 200 psi or 50 psi over operating pressure for a period of two hours. (Prior partial tests will not be recognized for acceptance purposes.) Test shall be scheduled 48 hours in advance and shall be completed prior to pre-final inspection. Test shall be witnessed by representatives of Long Range Facilities Planning, Facilities Management and Environmental Health and Safety. Leaks shall be corrected and re-tests made until system is deemed acceptable. Record results on standard NFPA #13 test form. Three signed copies shall be furnished at time of testing. Prior to pre-final inspection of system, contractor shall furnish two copies (one print and one PDF) of complete set of permanent plans showing entire system as installed. Plans shall show all pipe sizes, runs, valves, head temperatures, head counts, etc. and shall be made in neat and legible manner suitable for use as permanent record for future maintenance of system. No acceptance or inspection will be made without plans. Pre-final test shall include testing of all water flow and tamper switches. The installing contractor shall identify a hydraulically designed sprinkler system with an engraved or stamped metal sign secured with corrosion resistant wire, chain, or other approved means. Such signs shall be placed at the alarm valve, dry pipe valve, pre-action valve, or deluge valve supplying the corresponding hydraulically designed area; in accordance with NFPA 13. 5

NFPA 13 Fire Sprinkler Riser Detail RISER KEY NOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 5-0 DUCTILE IRON STUB-OUT FEED THRUST BLOCK SLEEVE THRU FLOOR 2 MAIN DRAIN WITH ANGLE VALVE 4 WAY SWAY BRACE EXTERIOR HORN/STROBE FLOW SWITCH GROOVED ELBOW HYDRAULIC DESIGN DATA PLATE SPARE SPRINKLER BOX DOUBLE CHECK VALVE ASSY 300 PSI PRESSURE GAUGES LISTED SYSTEM CONTROL VALVE WITH TAMPER TAMPER SWITCH 6