Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Similar documents
Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

Users Manual. Visit us at

Understanding Hazardous Locations Concepts

UL HAZARDOUS LOCATIONS SERVICES

Beamex. Calibration White Paper. Calibration in hazardous areas

Overview of Hazardous Locations as They Relate to Solenoid Valves

Beamex Calibration White Paper. Calibration in hazardous areas

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Guide to Hazardous Location Approvals:

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

[ TECHNOLOGY ] and does this definition affect a burner.

562/563. Infrared Thermometers

Electrical Installations Design, Selection, Erection and Inspection

Dräger X-am 7000 Multi-Gas Detection

Precision Infrared Thermometer. Users Manual

Infrared Thermometer

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Guide for hazardous areas

MicroRay IR-100 NEW. Inspection MicroRay IR-100

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX, NOMENCLATURE AND CODING

Users Manual. Infrared Thermometer

Guide to Intrinsically Safe Portable Radios

Infrared Thermometer. Getting Started

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Explosion-protected network cameras Safety first

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Precision Infrared Thermometer. Users Manual

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Dräger Polytron 8310 IR Detection of flammable gases and vapour

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

G-TECTA TM. Portable Gas Detection Instruments

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Intrinsically Safe Solutions

62 MAX/62 MAX + Infrared Thermometer. Users Manual

S T R I T T & P R I E B E I N C.

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INSTRUCTION & SERVICE MANUAL

Safe Operation Manual. Honeywell IQ Force Gas Detector

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

ATEX, NOMENCLATURE AND CODING

IRT2 Dual Laser IR Thermometer - User Guide

62 MAX/62 MAX + Infrared Thermometer

MT4 MAX/MT4 MAX + Infrared Thermometer

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 8700 IR Detection of flammable gases and vapors

62 MAX/62 MAX + Infrared Thermometer

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

ALTAIR 5X Multigas Detector Product Specification

Dräger Flame 2500 Flame Detection

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

62 MAX/62 MAX + Infrared Thermometer. Users Manual

MICROpeL 75 Combustible Gas Sensor Part Number: PM

INTRINSICALLY SAFE LIGHTING RANGE

CO warning instruments and gas spillage detectors

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

ATEX Safety Switches. More than safety.

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

EtherCAT Box Modules (EPxxxx-xxxx)

62 MAX/62 MAX + Infrared Thermometer

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

ULTIMA X5000. MSAX5000.com

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

ATEX Explained A brief Introduction

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

4) Intrinsic Safety Certification

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger X-am 7000 Multi-Gas Detection

S5000 Gas Monitor. GMS5000.com

INSTRUCTION MANUAL (ATEX / IECEx)

Dual certification! Air handling units for potentially explosive atmospheres

Manual PCE-889 pyrometer

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

64 Max IR Thermometer

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

Continuous level measurement Ultrasonic transmitters

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Dräger PIR 3000 Detection of flammable gases and vapours

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

manual addendum DELPHI Ex

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

GAS ANALYSIS / DETECTION Gas Detector

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Transcription:

Fluke 568 Ex Intrinsically Safe Infrared Intrinsically safe temperature measurements. Anywhere in the world. Product Announcement

Product Overview Value Proposition Meets intrinsically safe certifications from all major safety agencies for Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments. One tool suitable for use anywhere in the world. Ideal for petroleum, chemical, oil & gas, or pharmaceutical environments. Product Highlights Measure -40 C to 800 C (-40 F to 1472 F) with ± 1 % measurement accuracy Conductive case for carrying into hazardous areas Access advanced features easily with soft-keys and graphical display Accurate measurements from further away, with 50:1 distance-to-spot ratio Compatible with standard K-type miniconnector thermocouple (KTC) probe Adjustable emissivity, built-in material table Capture up to 99 points of data Versatile interface with multiple languages (user select) Two-year warranty

Who will buy Application Segments Temp Range Accuracy D:S Opportunity Repair and maintenance: Measure motor, pump to verify balanced phase-tophase power distribution and proper operating temperature Repair and maintenance: Measure panels, fuses, circuit brake, compressors, duct, vents in hard to reach areas Maintenance: Taking measurement of transformers, wires and components located high above ground. Maintenance & Quality control: Monitor the temperature during chemical processing Manufacturing Site 120 C Low Low - Medium Installer, Contractor of Electrical/HVAC 200 C Low Medium - High Utilities 120 C Low High Chemical 800 C Mediumhigh Medium- High Traditional applications of IR s on equipment maintenance (electrical motor for balanced phase-to phase power distribution, motor bearings, motor winding insulation), electrical maintenance (transformers, ballasts, utilities, uninterruptible power supplies), and process/product monitoring temperature on production line such as rubber to plastics can be applied using 568Ex but the operating environment is considered hazardous where inflammable gases and vapor exists which can cause explosion. Maintenance: Exterior of the kiln temperature, Monitor the surface temperature of the reformer tubes Petrochemical 800 C Medium Medium- High Such environment usually exists in oil & gas, petrochemical, refinery, and pharmaceutical industry 568 Ex will serve the needs of customers who must comply with EH&S regulations to ensure safety while operating in a hazardous environment where hazardous gases and vapor are present 3

Safety Certifications AGENCY ATEX/IECEx SAFETY RATING Zone 1 and 2 IECEx EPS 13.0006X Ex ia IIC T4 Gb 0 C Ta 50 C EPS 13 ATEX 1.525 X II 2G Ex ia IIC T4 Gb

What does it mean? Meaning of Marking: Zone 1 IIC T4 0 C Ta 50 C Marking: Class 1 Division 1 Groups ABCD T4 0 C Ta 50 C Type of Flammable Substance Class 1 - approved for strictest class * Class 1 - Flammable gas, vapors, and liquids * Class 2 - Combustible dusts * Class 3 - Ignitable fibers and flyings Area Classification Division 1 - approved to the strictest division for both: * Division 1 - flammable substances are continuously present or likely to exist under normal operating condition * Division 2 - flammable substances are not likely to exist under normal operating condition Gas Group Group B - approved fro Group B, also approved for Groups C and D, but not A. If no Groups are listed, approved for all. The gases are grouped according to certain physical characteristics on their explosive behavior Temperature Code If no temperature code is listed, meets strictest temperature code (T6) This is the maximum temperature that the equipment is allowed to emit without causing an explosion/fire. T4 in Zone 0, 1, 2 is equal to T4 and T4A in Division 1 and 2 Maximum Temperature T4 135 0 C (275 0 F) and T4A 120 0 C (248 0 F) Ambient Temperature range ( 0 C Ta 50 C) is also marked.

Understanding Zone vs Division Zone 0 Zone 1 Zone 2 Where ignitable Where ignitable concentrations Where ignitable concentrations of flammable concentrations of of flammable gases, vapors, or gases, vapors, or liquids: flammable gases, liquids: Are not likely to exist under normal operating vapors, or liquids are Are likely to exist under conditions present continuously normal operating Occur for only a short period of time or for long periods of conditions Become hazardous only in case of an accident time under normal May exist frequently or some unusual operating condition operating because of repair, conditions. maintenance operations, or leakage Division 1 Division 2 Where ignitable concentrations of flammable gases, Where ignitable concentrations of flammable vapors, or liquids: gases, vapors, or liquids: Are likely to exist under normal operating Are not likely to exist under normal operating conditions conditions Exist frequently because of maintenance/repair Are normally in closed containers where the work or frequent equipment failure hazard can only escape through accidental rupture or breakdown of such containers or in case of abnormal operation of equipment Table 2: Class 1 Group Comparison Zone IIC - Acetylene and Hydrogen IIB Ethylene IIA Propane Class/Division A Acetylene B Hydrogen C Ethylene D Propane

Fit in product line 568 Ex offers performance similar to 566, 568, PLUS Ex certification Range, D:S slightly under the premium 572-2 High-Temperature Infrared Fluke s only intrinsically safe infrared thermometer Temperature Range Distance to Spot Ratio Laser Sighting Emissivity Display Resolution Backlight Display Fluke 561 Infrared/Contact -40 C to 550 C -40 F to 1022 F Fluke 566 Infrared/Contact 40 C to 650 C -40 F to 1202 F Fluke 568 Infrared/Contact -40 C to 800 C -40 F to 1472 F Fluke 568 Ex Intrinsically Safe Infrared -40 C to 800 C -40 F to 1472 F 12:1 30:1 50:1 50:1 60:1 Single point laser Adjustable with three settings: Low (0.3), Medium (0.7). High (0.95) Single point laser By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 Single point laser By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 Single point laser By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 Fluke 572-2 High- Temperature Infrared/Contact -30 C to 900 C -22 F to 1652 F Dual laser Digitally adjustable from 0.10 to 1.00 by 0.01 or via builtin table of common materials Yes Two levels Two levels Two levels Two levels, normal and extra bright for darker environments

Items Included Fluke 568 EX Intrinsically Safe Infrared with red holster and leather grip Conductive hard carrying case K-type thermocouple bead probe User s manual with safety instruction sheet Recommended accessories 80PK-1 General Purpose Bead Probe Additional Features Following K-type probes are not Ex rated 80PK-8 Pipe Clamp Temperature Probe 80PK-9 Insulation-Piercing Probe 80PK-11 Type-K Flexible Cuff Thermocouple Temperature Probe 80PK-25 Piercing Probe 80PK-26 Tapered Probe 80PK-27 SureGrip Industrial Surface Temperature Probe Service Plan Fluke 568 Ex is backed by a two year warranty.

Order Details 568 Ex Open for Orders August 14 ATP Three weeks Sales Discounts Same as TEMP discount Fluke Model # 568 EX Fluke Oracle # 4321662 UPC Code 0 95969 66613 8 Description FLUKE-568 EX,INTRINSIC SAFE IR THERMOMETER, ATEX APPROVAL Country of Origin Germany ECCN EAR99 Harmonize 9025198080 WEEE Category 9 Dangerous Goods Category No Product Dimensions (H, W, D) 17.69 cm H x 16.36 cm L x 5.18 cm W (6.965 in H x 6.441 in L x 2.039 in W) Packaging Dimensions (H, W, D) 25.2 cm L x 19.2 cm W x 6.9 cm H (9.921 in L x 7.559 in W x 2.717 H ) Product Net Weight 0.340 kg (0.7496 lb) Package Net Weight 0.968 kg (2.134 lb) Battery Type AAA IEC Designator LR03 Cell Mass (g) 12 Rechargeable? No Dimensions (H, W, D) 45 mm x 10.5 mm x 10.5 mm (1.77in x.41 in x.41 in) Safety and Compliance IEC 60825-1; FDA Laser Class II; EMC 61326-1; CE Complaint Authorised Distributor: 46, Jalan SS 22/21, Damansara Jaya, 47400 Petaling Jaya, Selangor Darul Ehsan, Malaysia. Email: info@ampmech.com Web access: http://www.ampmech.com