RA2000 Thermostatic Radiator Valves

Similar documents
Thermostatic Radiator Valves (Caleffi)

RA 2000 Series RA 15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve

Data sheet Thermostatic sensors type RA 2000

Radiator Valve Program

caleffi hydronic valves page 1 of 12

RA2000 Commercial TRVs

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

Radiator Trap Radiator Valve

13-1. Temperature Regulator

Thermostatic Actuators

CATALOG HD.CAT Danfoss Hydronic Comfort Controls MAKING MODERN LIVING POSSIBLE

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Thermostatic mixing valves with replaceable cartridge for centralized systems

TRV 300 RADIATOR VALVES

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Installation Instructions

Temperature controller for steam (PN 25) AVT / VGS - external thread

Thermostat RT. Data sheet

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

EXTROL EXPANSION TANKS

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Thermostatic mixing valves with interchangeable cartridges

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

Basic Radiant Panel Model RHP-2-4

Automatic balancing valves ASV-PV (new generation) DN 32-50

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Mercury Mixing Kit (Code: ME1053)

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

Mikrotherm. Manual Radiator Valves With presetting

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

CRYOGENIC PRODUCTS SEB Series Trim Heater

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Installation. S Series Navigator Thermostatic Mixing Valve

Radiator valve inserts

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

NIBCO Radiant Panel Model RHP-2-4

Hoffman Specialty General Catalog

Basic Radiant Panel Models RHP, RHP-1 & RHP-2

Thermostatic valves with radiator connection systems

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

TECHNICAL. Series 18. Pump Packages

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Automatic Temperature Controller (ATC)

ECO1ZN3P, ECO2ZN4P ECO

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

Flush individual room control for floor heating systems

Multilux 4-Eclipse-Set

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

SECTION METERS AND GAGES FOR PLUMBING PIPING

Basic Radiant Panel Model RHP-3

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

DEVIATING VALVES ART K063

Installation S

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Astro Express 2 - Hot Water Delivery System

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Thermostat KPU. Data sheet

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Series 1140 and 1141 Temperature Regulators

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

SERVICE REQUIREMENTS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Installation and operating instructions

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

TEMPERATURE CONTROLLERS

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Cabinet Unit Heaters Steam / Hot Water

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Transcription:

Data Sheet RA2000 Thermostatic Radiator Valves Application regulate the flow of hot water or steam through free-standing radiators, baseboards or convectors in hot water and two-pipe low pressure steam systems. RA2000 Operators Operator Features Valve mounted operators provide fast acting modulating control of the space temperature through a patented vapor charge, ensuring the highest level of comfort control. Standard Valve ed Dial and Sensor Standard Valve ed Dial with Remote Sensor Standard valve mounted operators are equipped with a theft protection device and a snap-action mechanism that allows for easy installation and removal without the use of tools. Tamper Resist. Valve Mtd. Dial and Sensor Tamper Resist. Valve Mtd. Dial w/ Remote Sensor Tamper resistant versions of the valve mounted operators are available to discourage unauthorized adjustment, vandalism and theft. Combined Remote Mtd. Dial and Sensor Separate Remote Mtd. Dial and Sensor Conforms to ASHRAE / ANSI Standard 102-1983. Valve Features RA-2000 valves are fitted with a packing gland assembly that is replaceable while the system is in operation. The packing gland is fitted with a grease cup to ensure the o-ring packing is lubricated for life. RA2000 Valve Bodies Sturdy EPDM rubber valve disc provides a positive seal against the valve seat at differential pressures of up to 20 PSI in Hydronic hot water heating systems. Straight FPT x MPT Tailpiece Angle FPT x MPT Tailpiece Plastic cap supplied to protect the valve pushpin can provide manual control of the valve during installation. If manual operation is required, a separate hand knob is available as an accessory. Conforms to ASHRAE / ANSI Standard 102-1983. Side Angle FPTxMPT Tailpiece Straight VD.UP.A1.22 Danfoss 03/04

Technical Specifications Hydronic Hot Water Systems Maximum Temperature: 250ºF Maximum Static Pressure: 145 psi Maximum Test Pressure: 232 psi Max. Diff. Pressure (water): 20 psi Max. Sensor Temperature: 140ºF Adjustable Temp. Range: 45-86ºF (7-30ºC) Two-Pipe Low-Pressure Steam Systems Maximum Temperature: 250ºF Maximum Test Pressure: 232psig Maximum Steam Pressure: 15psig Max. Sensor Temperature: 140ºF Adjustable Temp. Range: 45-86ºF (7-30ºC) Comfort Control Control of the space temperature at a comfortable level is easily accomplished by adjusting the dial clockwise or counter-clockwise. The dial has a numbered scale of 1 to 5 corresponding to temperatures of approximately 57ºF to 79ºF (14ºC to 26ºC). Should the space be vacant for an extended period or if the room is to be aired, the dial can be set to the symbol for freeze protection (50ºF or 9ºC) to save energy. Design and Function No. Description The RA 2000 thermostatic operator 1 Operator setting dial (ABS) consists of a saturated vapor charged 2 Vapor charged bellows 1 18 bellows and a setting dial. The dial is 3 Safety spring (steel) 4 Adjustment spring (steel) set to the position equal to the 2 17 5 Locking/limiting pin (steel) desired temperature. When the 6 Pressure spindle (plastic) 3 16 ambient temperature lowers, the 7 Snap-on mounting ring pressure from the bellows will reduce, 8 Valve body (nickel plated brass) 4 15 allowing the valve to open. A rise of 9 nut (nickel plated brass) temperature increases the pressure 10 Tailpiece (nickel plated brass) 5 14 in the bellows closing the valve. 11 Valve disc (EPDM) The balanced pressures between the 12 Valve spindle (brass) 6 13 13 Valve spring (stainless steel) adjustment spring and the bellows 14 Back seat washer (EPDM) 7 12 ensure a smooth and modulating 15 Valve bonnet (brass) operation of the valve. 16 Pressure pin (stainless steel) 8 11 Danfoss RA 2000 are manufactured 17 Packing o-ring (EPDM) to the highest quality standards in an 18 Packing gland (DRZ brass) 9 10 ISO 9001 factory. Danfoss Inc. 2 VD.33.G2.R1

Application Typical Installation Configuration Operator Type Valve Type Free-Standing Radiators The freestanding hot water or low-pressure steam radiator is located where air circulation is unobstructed and passes freely over the operator. Free-Standing Radiators Freestanding hot water or lowpressure steam radiator. Air circulation does not pass freely over the operator due to furniture, drapes, coverings, etc. Valve -mounted dial and sensor, standard or tamperresistant models. Always install these operators in a horizontal position. Valve -mounted dial with remote sensor, standard or tamperresistant models. The sensor can be mounted on a wall up to 6 feet away in a location free of drafts. Angle, Baseboards/Convectors The hot water or low-pressure steam fin-tube baseboard or convector is located where air circulation is unobstructed and passes freely over the operator. Valve -mounted dial and sensor, standard or tamperresistant models. Always install these operators in a horizontal position. Baseboards/Convectors Hot water or low-pressure steam fin-tube baseboard or convector. Air circulation does not pass freely over the operator due to furniture, drapes, coverings, etc. Combined remote mounted dial and sensor. The dial operators are wall mounted and are available with 6, 16 or 26 long capillary tubes. Angle, Baseboards/Convectors The hot water or low-pressure steam fin-tube baseboard or convector arrangement requires the dial and sensor to be mounted separately, away from the valve. Separate remote mounted dial and sensor. The remote dial mounts on the wall or enclosure (max. 6 away). The sensor is mounted beneath the radiation or on a draft free wall 6 away from the dial. Angle, IMPORTANT: Install operators with valve mounted sensors horizontally. If mounted vertically, the operators will sense heat radiating upwards from the termination unit and make an inaccurate determination as to space temperature. Danfoss Inc. 3 VD.33.G2.R1

Ordering Information RA 2000 Operators Symbol Code No. Description Sensor Capillary 013G8250 Valve mounted dial & sensor Built-in - 013G8252 Valve mounted dial with remote sensor Remote 6 013G8240 013G2922 Valve mounted dial and sensor, tamper-resistant Valve mounted dial with remote sensor, tamper-resistant Built-in - Remote 6 013G8562 Combined remote mounted dial & sensor* - 6 013G8565 Combined remote mounted dial & sensor* - 16 013G5068 Combined remote mounted dial & sensor - 26 013G8564 Separate remote mounted dial and sensor* Remote 6 6 * Includes socket for use on RAV, KOVM, and VMT valve bodies. RA 2000 Valves Symbol Code No. Size Pattern C v 013G8015 1 2 1.6 013G8020 3 4 2.7 Straight 013G8025 1 2.8 013G8032 11 4 2.8 013G8014 1 2 1.6 013G8019 3 4 Angle 2.7 013G8024 1 2.8 013G8031 11 4 2.8 013G8013 1 2 1.6 013G8018 3 4 Side 2.1 013G8023 1 Angle 2.8 013G8030 11 4 2.8 013G8042 1 2 1.6 013G8044 3 4 Straight 2.7 Connections (inlet x outlet) FPT X MPT Tailpiece FPT X MPT Tailpiece FPT X MPT Tailpiece C v is the water flow rate through the fully open valve at a pressure drop of 1psi. To determine the pressure drop through the valve at other flow rates use the formula:?p (Q/C v ) 2, where Q water flow in GPM. Danfoss Inc. 4 VD.33.G2.R1

Dimensions Valve Type Connection Type L1 L2 L3 L4 L5 H1 H2 Straight Angle Side Angle 1 2 NPT 2 5 / 8 33 4 1 57 / 64 33 4 3 4 NPT 2 29 / 32 4 3 / 16 2 1 / 16 3 15 / 16 1 NPT 3 17 / 32 4 31 / 32 2 1 / 16 3 15 / 16 11 4 NPT 41 4 5 29 / 32 2 9 / 64 4 1 / 64 1 2 NPT 1 3 / 16 2 9 / 32 1 1 / 64 1 57 / 64 33 4 3 4 NPT 1 11 / 32 2 5 / 8 1 9 / 64 2 1 / 16 3 15 / 16 1 NPT 1 9 / 16 3 1 11 / 32 2 1 / 16 3 15 / 16 11 4 NPT 13 4 3 3 / 8 1 9 / 16 2 1 / 16 3 15 / 16 1 2 NPT 1 1 / 8 21 4 1 1 / 64 2 3 / 8 41 4 3 4 NPT 1 11 / 32 2 5 / 8 1 9 / 64 2 7 / 16 4 5 / 16 1 NPT 1 9 / 16 3 1 11 / 32 2 3 / 8 41 4 11 4 NPT 13 4 3 3 / 8 1 9 / 16 2 3 / 8 41 4 1 2 2 5 / 8 3 15 / 16 1 57 / 64 33 4 3 4 2 15 / 16 4 5 / 8 2 1 / 16 3 15 / 16 Danfoss Inc. 5 VD.33.G2.R1

Capacity Hydronic Hot Water Applications Example: Flow Required: 0.65 USgpm Pipe Size: 1 2 Solution: Draw a line from 0.65 USgpm until it intersects with the dashed line for the 1 2 valve. Draw a vertical line down to find the additional system pressure drop due to the valve will be 0.6psi. Note: For best control, select valve based on 4ºF P-deviation and maximum 5psi pressure drop. P- deviation is the difference between the thermostat setting and the actual space temperature. For best comfort control and long life, valves should be selected to provide design flow at a 4ºF P- deviation. The shaded area represents differential pressure above those recommended for quiet operation. The maximum differential pressure ratings indicate the maximum pressure at which valves regulate satisfactorily. In order to prevent noise, pumps that provide only the required pressure should be recommended. Experience shows that in most systems a differential pressure of 0.5 2.5psi across the valve is sufficient to provide the required flow. Low Pressure Steam Applications Step-by-step selection technique 1. Before selecting valves, consider P-deviation. 2. Check that system pressure is below 15psig. 3. Determine load requirements for each valve. Example: Design load: 28MBH Pipe Size: 3 4 P-deviation 4ºF Solution: From the table below a 3 4 valve will provide 28MBH at a 4ºF P-deviation at a pressure drop of 3psi. If the system pressure is 3psi or greater a 3 4 valve can be used. Pressure Drop 1 psig 2 psig 3 psig 4 psig 5 psig P-Deviation ºF 4 Fully open 4 Fully open 4 Fully open 4 Fully open 4 Fully open Valve Size Rating Code 1 2 MBH 10 16 14 22 16 28 20 32 35 62 3 4 MBH 15 30 20 40 28 50 32 58 60 108 1 & 11 4 MBH 18 40 25 52 30 60 36 72 66 140 Conversion Factors: Sq. ft. EDR to Btu/hr Sq. ft. EDR x 240 (steam) Btu/hr to Sq. ft. EDR Btu/hr 240 1 MBH 1,000 Btu/hr Rating Abbreviations: MBH Thousands of Btu/hr. EDR Equivalent Direct Radiation Important P-deviation refers to the difference between the thermostat setting and the actual space temperature. For best comfort and long life, valves should be selected which provide the design heating load at approximately a 4ºF P-deviation. Danfoss Inc. 6 VD.33.G2.R1

Spare Parts and Accessories RA-2000 Valve Operators Code No. 013G1236 013G1215 013G1237 Screwdriver tool set Description Limitation pins for RA 8250/52 (30 pcs) Limitation pins for tamper resistant operators RA 8240 / 2922 (30 pcs) 013G5245 Anti-theft protection clips for RA 8250/52 (20 pcs) 013G8250 013G8252 013G1232 Locking screw plugs for tamper resistant operators RA 8240 / 2922 (50 pcs). 013G8240 013G1672 Cover plate for scale window of tamper-resistant operators (20 pcs) 013G2922 013L1239 Staple gun for securing of capillary tube RA Socket for RA-2000 Wall Operators 013G8562 013G8565 Position No. Description Code No. 013G5068 1 Socket Body for RA-2000 013G5191 013G8564 2 Bellows Holder (set of 2 pcs) 013G5503 RAV Socket for RA-2000 Wall Operators 013G8562 013G8565 Position No. Description Code No. 013G5068 1 Socket Body for RAV, VMT, and KOVM 013G5193 013G8564 2 Bellows Holder (set of 2 pcs) 013G5503 RA-2000 Valve Bodies Code No. 013G0290 013G5002 Packing gland Description Manual adjustment handle (Water applications only) 013-7045 Gasket for RA valves 013G8070 RA to RA 2000 adapter 013G8072 RAV to RA 2000 adapter WARNING: Brass products such as Danfoss thermostatic radiator valves should not be installed in hydronic or steam heating systems that are being treated with medias that contain, or that during the process of treatment could develop, agents aggressive to brass. In concentrations larger than shown, agents such as Ammonia (0.2mg/l), Mercury (0.01mg/l), Oxygen (0.01mg/l), Carbon Dioxide (0.05mg/l), or Chloride (20mg/l) must be avoided. Further the ph-value of the medium in contact with the brass products should not exceed 9.5. Neglecting the above restrictions may in some circumstances cause damage to the brass in the valve allowing the heating fluid to escape, possibly scalding any bystanders. Note: To avoid internal damage and void the warranty, mineral oils must not come in contact with EPDM valve components. Danfoss Inc. 7 VD.33.G2.R1

Danfoss can accept no responsibility for possible errors in printed materials and reserves the right to alter its products without notice. All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss Comfort Controls 7941 Corporate Drive Baltimore, MD 21236 USA Tel.: 443 512 0266 Fax: 443 512 0270 www.danfossheating.com Danfoss Inc. 7880 Tranmere Drive Mississauga, ON L5S 1L9 Canada Tel.: 905 676 6000 Fax: 905 676 0279 www.danfoss.ca VD.33.G2.R1 Danfoss 11/04 FEDGRA