Intercom Systems Video Intercoms

Similar documents
Pure Glass. saturn.clipsal.com

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

PERTH. Smart Living. C-Bus Control and Management System Case Study 13. clipsal.com

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

StarServe IR/RF Controller Installation Instructions. 2031RFT Series

Dimmer / Fan Controller Installation Instructions

Clipsal Integrated Systems International Representatives China Head Office Greece Hong Kong South Africa Offices in all States Taiwan NSW VIC

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

C-Bus Four Channel Analogue Output Unit Installation Instructions

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Energy cost saving made easy!

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

C - B u s C - T o u c h U s e r s G u i d e C T Series

C-Bus Reflection Range Installation Instructions

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

DIC-221 Intercom Series Instruction Manual

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Universal Clamp Meter

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

TruVision Bullet IR Camera Pocket Guide

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

TruVision Bullet IR Camera Pocket Guide

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

medilec The Tools of a Specialist medical electrical equipment clipsal.com/cis

C-Bus Four Channel General Input Unit Installation Instructions

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Installation and Operation Manual. Model Q916

Operating Instruction Manual

Operating Instruction Manual

Mains Power Filter 970MF10 970MF20. Installation Instructions

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Universal Dimmer E450UD Series. Installation Instructions

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Colour Observation System

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Return loss measurement of fiber optic components

Accuracy counts! Sensors with analog output

IS-4500 TCP/IP Video Door Phone System

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Installation plan Heat pump dryer PT 8203 SL WP

Open-area Smoke Imaging Detector. Engineering Specification

Sunbeam Tower Fan with Night Mode

Dräger Polytron 5720 IR Toxic Gas Detection

Installation Instructions

SECTION VIDEO SECURITY COMMUNICATION SYSTEM. Logo. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

QSW8209. LCD Baby Monitor Wireless Camera

D200S. Operating Instructions. Intercom System. Your D200S System has been installed by: Your D200S System has been manufactured by:

Get connected with Xantrex Grid-Tie Inverters

TRAVELMATE. Instruction Manual

AJ3225. Clock Radio. User manual DUALALARM LARM CLOCK RADIO ALARM 2 SET TIME SET ALARM2 SET ALARM1 CLOCK ALARM 1 ALARM RESET SLEEP

D45. High performance door entry system CATALOGUE. A Group Brand

6.5L SLOW COOKER INSTRUCTION MANUAL

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

IS-6500 TCP/IP Video Door Phone System

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.

USER MANUAL. Adventure Kings 50L Refrigerator

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

DESCRIPTION FEATURES WARNINGS APPLICATIONS

LED Sensor Floodlight AZPOSE XL-S

Installation and Operation Guide

Waterpik Water Flosser Model WF-02

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Ceiling Microwave presence/absence detector 12-24V AC/DC

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

FF-SG Series. Safety light curtain Compact and low-cost unit

Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

OPERATION, INSTALLATION AND MAINTENANCE MANUAL. THX Flush Mount Enclosure. Take heating to the Max!

Dräger Polytron 5720 IR Detection of carbon dioxide

Motion sensors for every application

MILLI CUBE HEATED TOWEL RAIL 825 X 600

TRAVELMATE FRIDGE FREEZER Instruction Manual

USER MANUAL. Adventure Kings WiFi Refrigerator

SKYLINE panel with fingerprint

Sunbeam Remote Controlled Tower Fan

14 B&W OBSERVATION SYSTEM MODEL: HD14S1042-A

Dräger PIR 3000 Detection of flammable gases and vapours

Product & Assembly Manual

Classic Heater Spa Pool Controller

CMT MANUAL 6. NMC SENSORS

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Sunbeam Remote Controlled Tower Fan

Transcription:

8.0 International Offices CHINA Clipsal China Ltd Tel: +86 755 8237 5577 Fax: +86 755 8237 5576 sales@c-bus.com.cn GEORGIA Clipsal Contact Tel: +995 32 65 5599 Fax: +995 32 65 6699 clipsalcontact@gol.ge GREECE Clipsal Hellas S. A. Tel: +30 1 993 9165 Fax: +30 1 993 9730 sales@clipsal.gr HONG KONG Clipsal Integrated Systems (HK) Ltd Tel: +852 2487 0261 Fax: +852 2487 0993 clipsal_asia@clipsal.com.hk INDIA Clipsal Industries India Pvt Ltd Tel: +91 22 5695 2666 Fax: +91 22 5693 4988 mumbai@clipsalindia.com INDONESIA PT Clipsal Graha Nusantara Tel: +62 21 630 6430 Fax: +62 21 630 7729 hiro@rad.net.id KENYA Clipsal East Africa Ltd. Tel: +254 2 551931/2, 555744 Fax: +254 2 551934 cea@wananchi.com MALAYSIA Clipsal Integrated Systems (M) Sdn Bhd Tel: +603 7665 3555 Fax: +603 7665 3155 sales@cisasia.com.my NEW ZEALAND Clipsal Industries (NZ) Limited Tel: +64 9 576 3403 Fax: +64 9 576 1015 headoffice@clipsal.co.nz PAKISTAN Clipsal Pakistan (PVT) Ltd Tel: +92 21 506 7278 Fax: +92 21 506 3369 clipsal@cyber.net.pk PHILIPPINES Clipsal Representative Office Tel: +632 716 2225/2229 Fax: +632 716 2251 clipsal_ph@skyinet.net SINGAPORE Clipsal Integrated Systems Pte Ltd Tel: +65 6266 1998 Fax: +65 6266 3922 sales@cisasia.com.sg SOUTH AFRICA Clipsal South Africa (Pty) Ltd Tel : +27 11 314 5200 Fax: +27 11 314 5294 clipsal@iafrica.com SRI LANKA Clipsal Sri Lanka (Private) Ltd. Tel: +94 74 792 123 Fax: +94 74 792 126 switchon@clipsal.lk TAIWAN Clipsal (Taiwan) Co., Ltd Tel: +886 2 255 83456 Fax: +886 2 255 83000 clipsal@clipsal.com.tw THAILAND Clipsal (Thailand) Co., Ltd Tel: +662 952 5338 Fax: +662 952 5337 clipsal@clipsal.th.com UNITED ARAB EMIRATES Clipsal Middle East Tel: +971 6 5570 777 Fax: +971 6 5570 333 clipsal@emirates.net.ae UNITED KINGDOM Clipsal Integrated Systems Tel: +44 (0) 1494 521111 Fax: +44 (0) 1494 523333 cis@clipsal.co.uk UNITED STATES OF AMERICA Clipsal USA Incorporated Tel : +1 858 674 2555 Fax : +1 858 451 9777 rosalind@clipsalusa.com VIETNAM Clipsal - VTEC Tel: +848 856 3002 Fax: +848 856 3006 clipsal.vn@clipsalvn.com ZIMBABWE Clipsal Zimbabwe (PVT) Ltd Tel: +263 73 2483/2484 Fax: +263 73 2517 grickards@ruwa.clipsal.co.zw Intercom Systems Video Intercoms 5480 SERIES Products of Clipsal Integrated Systems Pty Ltd ABN 15 089 444 931 Head Office 12 Park Terrace, Bowden South Australia 5007 International Phone +61 8 8269 0560 International Fax +61 8 8346 0845 Internet clipsal.com/cis Email cis@clipsal.com.au M00036/00 www.clipsalsecurity.com I N S T A L L A T I O N M A N U A L

Table of Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Equipment Description... 4 3.1 Things to Note... 5 3.2 Intercom System Installation... 6 3.3 Additional Information... 12 4.0 Product Specifications... 13 5.0 Caution... 14 6.0 Warranty... 15 7.0 Technical Support and Troubleshooting... 15 8.0 International Offices... 16 1.0 Product Range 5480VPC Video Intercom Station, Colour, 18VDC Operation (power supply not included) 5480DSCA Door Station, Colour Camera, Metal Enclosure, Weatherproof 5480VPB Video Intercom Station, Black and White, 18VDC Operation (power supply not included) 5480DSBA Door Station, Black and White Camera, Metal Enclosure, Weatherproof 2.0 Description The 5480 series intercom systems are designed for stand-alone applications, single private network installations and are ideal for residential and commercial premises. The video intercom stations are designed to provide a user interface between the visitor and homeowner, and the units feature a door release mechanism for remote door opening. Multiple intercom stations may be connected to a single door station, or connected together for a handy room-to-room intercom system. Copyright Notice 2003 Clipsal Integrated Systems. All rights reserved. Trademarks Clipsal is a registered trademark of Gerard Industries Pty Ltd. All other logos and trademarks are the property of their respective owners. Disclaimer Clipsal Integrated Systems reserves the right to change specifications or designs described in this manual without notice and without obligation. - 2 - - 3 -

3.0 Equipment Description Intercom Station 1. Receiver 2. Phone volume control 3. Colour tone adjustment (for colour unit), Contrast adjustment (for B/W unit) 4. Screen 5. Monitor button 6. Call button 7. Door release button 8. Connection socket for electronic door lock 9. Connection socket for audio/video control wiring 10. Power connection (18VDC) 11. Brightness adjustment Door Station 3.1 Things to Note 1. When the call button or monitor button is pushed to call up the picture, it takes about five seconds before the camera s auto sensitivity control engages. While the auto sensitivity is working, the picture may not be stable, but will quickly stabilise. 2. This product is designed to be used as an intercom and cannot be continuously used as a monitoring camera. 3. Fluctuations in atmospheric temperature can cause condensation at the door station s lens, resulting in a poor picture at the intercom station. Performance improves after condensation dissipates. 4. If the call is initiated from the door station, both audio and video will timeout after 3 minutes. If the call is initiated from the intercom station, both audio and video will timeout after 50 seconds. Pressing the Call button will reset the video image. 5. When two or more intercom stations are installed, the second or subsequent intercom stations can join in a conversation when the receiver is picked up whilst another intercom station is in use. 6. When a call is received from the door station while calling or talking with another intercom station, a second intercom station can join in the conversation and be heard at the door station. 7. When the ambient light falls below 10Lux, the built-in infrared LEDs automatically turns on to maintain the video picture quality. Because the irradiation range of the infrared LEDs are narrower than the camera s viewing range, the effective range for night operation will be reduced. 1. Infrared compensation LEDs 2. Microphone 3. CCD camera 4. Speaker 5. Door bell button 6. Connection socket for audio/video control wiring - 4 - - 5 -

3.2 Intercom System Installation 3.2.1 Mounting Position, Intercom Station The standard height for the intercom station installation is 1450mm (note: this depends on the individual s height), so the centre of the monitor coincides with the line of vision. The distance between the ground level and the bottom of the intercom station is approximately 1300mm. 1300mm 1450mm 3.2.3 Adjusting Camera Angles The camera lens angle on the door station may be adjusted in the vertical and horizontal planes. The vertical angle may be adjusted by approximately +/-12 degrees, by adjusting the screw marked (1) below. The horizontal angle may be adjusted by approximately +/-12 degrees, by adjusting the screw marked (2) below. Adjust the camera angle to suit the installation. CLIPSAL CLIPSAL 3.2.2 Mounting Position, Door Station The standard height for the door station installation is 1400mm. (note: this depends on the individual s height), so the centre of the lens coincides with the line of vision. The distance between the ground level and the bottom of the door station is approximately 1300mm. The total field of view of the door station lens is 90 degrees about the horizontal axis. The maximum distance between the caller and door station for a clear image should be less than 800mm. 800mm 1400mm 90 1300mm 1. VERTICAL ANGLE ADJUSTMENT 2. HORIZONTAL ANGLE ADJUSTMENT - 6 - - 7 -

3.2.4 Cable Types and Maximum Distance 1. Use only parallel dual-core cable for optimum picture quality. Connecting with or branching to other types of cable or dividing the parallel dual-core may result in noise on the picture or poor picture quality. 2. The table below illustrates the cable types and maximum distances permitted between the intercom station and door station. Application Wire Conductor Cross Maximum Section Area Distance Door Lock Release 2 x 0.5 0.5mm 2 50m Interconnection between Door Station 4 x 0.5 0.5mm 2 50m to Intercom Stations Interconnection between Intercom Stations 4 x 0.5 0.5mm 2 50m 3.2.5 Wiring Details The figure below illustrates the wiring connection between a single door station and single intercom station. The figure below illustrates the wiring connection between a single door station and multiple intercom stations (up to 4 intercom stations are allowed). - 8 - - 9 -

3.2.6 Installing the Intercom Station Select a location for the intercom station, with reference to section 3.2.1. Install a British Standard (60.3mm) or Australian/US Standard (84mm) wall box. 3.2.7 Installing the Door Station Select a location for the door station, with reference to section 3.2.2. Make a hole in the wall measuring 190mm (H) x 120mm (W) x 38mm (D). Attach the mounting plate to the wall box, with the screws provided. Insert the wall box provided. Attach cables and plug-pack to the intercom station, and secure to the bracket. Attach cables to the door station, and secure to the wall box using the screws provided. Insert the top and bottom covers over the fixing screws. - 10 - - 11 -

3.3 Additional Information Please confirm the following before requesting service. When neither calling out nor conversation are possible: Is the main plug of the monitor unit properly connected? Are the wires of the monitor units and the camera unit connected to their terminals? Has the unit timed out after 3 minutes? When the picture is not clear: Are brightness, colour, tone and hue for the monitor unit properly adjusted? Is the camera front and monitor surface clean? Condensation at the camera unit s lens causes a poor picture at the monitor unit. Performance improves after condensation dissipates. Cleaning the Equipment Clean the main unit with a soft dry cloth. For cases where dirt is hard to remove, use mild detergent and wipe away. Do not use strong abrasive chemicals as this will dull the transparent resin on the monitor screen. 4.0 Product Specification Catalogue No. 5480VPC 5480VPB LCD Screen Size 100mm (4 ) Colour TFT LCD 100mm (4 ) B/W Flat Tube Picture Distortion < 5% Signal to Noise Ratio More than 70dB Number of Pixels 105,600 Power Consumption Standby 0.2W, Maximum 9W Power Requirement DC 18V @ 800mA Call Signal Electronic chime Installation Location For indoor use only (hanging type) Materials ABS Plastic, White Electric Horizontal Resolution 420 Lines External Dimensions 225 x 200 x68mm Maximum Number 4 of Intercom Stations Time Out Period 3 minutes or 50 seconds (refer to item 4 in section 3.1) Operating Temperature -10 to +40 C Operating Humidity 45-85% RH Catalogue No. 5480DSCA 5480DSBA Horizontal Resolution 450 Lines Imaging Device 1/3 CCD Minimum Illumination 0.2 Lux Materials Extruded aluminum metal enclosure, silver External Dimensions 193 x 130 x 54mm Operating Temperature -10 to +40 C Operating Humidity 45-85% RH Installation Location For indoor and outdoor use (rain resistant), it is recommended that the equipment is installed in a weather protected environment for long service life. - 12 - - 13 -

5.0 Caution 1. Do not install the door station unit at a location where it will be exposed to direct sunlight. If the camera is exposed to direct sunlight, a white picture will be displayed at the monitor. 2. To prevent damage to the equipment, malfunction, noise interruption, or poor picture quality due to induced voltage from lightning, or the electrical lines of other equipment, avoid outside overhead wiring as well as parallel wiring with electrical power lines or other electrical lines for telephones and other devices. 3. Do not attempt to modify this equipment. It is possible for high voltage to remain inside the electrical circuits even when power is turned off. 4. Be sure to connect the power to an appropriate outlet for home use. Connecting to an inappropriate outlet or an inverter type outlet may cause damage to the equipment, noise interruption, or noise in the picture. 5. Do not install the monitor unit at the following: Directly above or near a heater, such as an electric, gas or oil heater. Any location where it might be exposed to direct sunlight. A location which is high in humidity, such as a bathroom. A location where harmful gas or excessive dust is present. A location where the unit may be exposed to moisture or chemical. 6. Although the door station is rain resistant, do not expose it directly to water. For example, water from a garden hose, etc. 7. This product is not compatible with intercom units and door station units from other manufacturers. Connecting this equipment to other manufacturers equipment may cause damage to both units. 6.0 Warranty 1. This product is guaranteed against faulty workmanship and materials for a period of one (1) year from date of installation. 2. Clipsal reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. 3. This warranty is expressly subject to the device being installed, wired, tested, operated and used in accordance with the manufacturer s instructions. 4. All costs of the claim shall be met by Clipsal, however should the product that is subject to the claim be found to be in good working order all such costs shall be met by the claimant. 5. When making a claim the consumer shall forward the product to the place of purchase, together with adequate particulars of the defect within twenty eight (28) days of the fault. 7.0 Technical Support and Troubleshooting For further technical assistance in using Clipsal Security products, please consult your nearest Clipsal Sales Representative or Technical Support Officer. Technical Support Hotline 1300 722 247 (Australia only) Technical Support Email techsupport.cis@clipsal.com.au - 14 - - 15 -