Nightfall. led emergency egress lighting

Similar documents
Architectural / led luminaires

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

The New Lux-Ray LED Emergency Lighting

NEMA-4X Series. Certified for Harsh Environment Applications

Project. Comments. Prepared by

IOTA Exit Signs. IOTA Emergency Fixtures

NYC Approved Product Series

PRODUCT OFFERING QUALITY VALUE VERSATILITY

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

THE UNITED LIGHTING GROUP

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Emergency Lighting. Product Guide LED. The right source for the. right light

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Catalog Number. Notes

CHINESE NEW YEAR DEADLINE SOLUTIONS

Distributor Select LED Families

Bdl60u Fluorescent Emergency Ballast

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

Exit/Emergency Lighting Guide

TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25

SECTION EXTERIOR LIGHTING

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

P Archie. Incandescent NAME: PROJECT: Diameter: 5-3/4 Height: 8-3/4 Overall ht. w/stem: 75

Surface Mount Series Luminaires

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Welcome. Page 2. Iconic LED, LLC 1806 W Pinhook Rd. Lafayette, LA Main (337)

MALIBU FM /2" N-Brushed Nickel. Nickel **ESTIMATED FROM LED SOURCE

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

LED Lighting Product Catalog ver. 1

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

BAS SDL8' LED Strip Diffused Lens

LED RETROFIT SOLUTIONS

ENVISAGE V LED CEILING & ADA WALL THIRD EDITION JESCO LIGHTING

SHAPING THE EXPERIENCE OF LIGHT CYNDER INTERIOR & EXTERIOR DOWNLIGHT & UPLIGHT. 1

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Pictogram Exit Signs Catalogue

SOLID STATE ILLUMINATED RAIL

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

Arlington. Full Cutoff. Utility Series

SDL4 LED Strip Diffused Lens

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT

Applications. Standard Materials

Lighting Solutions. from a Leader in Light Source Technology

LED Lighting Product Guide. Winter A portfolio of industry-leading solutions that are changing the way we look at light.

Lighting. Showroom Lighting Requirements. Introduction. Technology. Fixture and Performance

Dublin airport - Dublin, Ireland

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Sunrise Lighting Systems, Inc

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

LED FIXTURE CATALOG. Shining light into the future

OPERATIONS AND STORAGE BUILDING

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

New LED Product Offerings

Dimensions (111mm) (111mm) 3 (76mm)

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Outdoor Emergency Lighting Application Guide

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

Who is Iconic LED? Page 2. Phone:(337)

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

3.75 Gyro Shift Multiples Single Head

SECTION LIGHTING

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

The Future is here & It s Bright!

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

CHAPTER 7 DEVELOPMENT STANDARDS

MANUFACTURED IN THE UK

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

A UTO D EALERSHIP L IGHTING

Product Specifications MaxLumen MRI LED Diffused Lighting

Related Sections: TBD. Effective Date: January 1, 2016

Hornet HP. Square Glass Downlight

Product Specifications MaxLumen MRI LED Diffused Lighting

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

Ivalo Lumaris LED Linear Lighting

Spectron LSN (Life Safety Network) Suggested Specifications

Ivalo Lumaris LED Linear Lighting

Power (max) Current (max)

Ivalo Lumaris LED Linear Lighting

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

Max 4 Flush Lens RECESSED

Product Specifications MaxLumen MRI LED Diffused Lighting

A complete range of Specification Grade Emergency Lighting Products and Accessories ON THE PROJECT, ON THE SHELF, ON THE JOB

SECTION INTERIOR LIGHTING

Notes. Custom powder coat finished are available.consult factory. To ensure the natural appearance of stainless steel,

Transcription:

Nightfall led emergency egress lighting

Nightfall led emergency egress lighting Combining a sleek, architectural, low profile design with high performance makes the Nightfall Series an attractive LED solution for both indoor and outdoor emergency lighting. These fixtures boast an average of 40 to 55 center-to-center spacing, optimizing light output and minimizing the number of fixtures needed for typical applications. As an added benefit, the entire Nightfall Series meets the ARRA requirements and Buy America Recovery Act provisions for Made in America products. As a spec grade offering, the Nightfall series has been designed to truly deliver you more. p4 p6 p8 p10 p12 p14 Guardian self-test/self-diagnostics option The Guardian offers an added safety feature that reports issues or malfunctions and allows service personnel the option to take proper steps to correct any problems. The Guardian monitors the fixture and reports any malfunctions. The AC power, battery supply and charging circuit are all monitored continuously and should a failure be detected, visual status will occur immediately via the multicolored LEDs. Pathsafe security/night lighting option The Pathsafe option allows the fixture to be used as an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell or other automatic means. 2

3

Nightfall Nf1 Cylinder LED Emergency Lighting led emergency egress lighting Features Outstanding 50-55 foot center-to-center spacing Complete fixture series meets American Recovery & Reinvestment Act of 2009 (ARRA) requirements and Buy American Recovery Act provisions. Architectural, cylinder style design Attractive aluminum extrusion design for both cylinder and canopy plate Available in a variety of lamping options ranging from 8-15 watts Pathsafe security or night light option (SEC) available offering incredibly low wattage consumption when compared to traditional fluorescent or incandescent systems during night operation Mounts with standard back plate to wall or ceiling. Optional mounting direct to J-box or pendant mounting ETL listed 90 minute emergency run time, 24 hour recharge time Optional Guardian self-testing/self-diagnostics (G2) available Designed to blend with any environment, this Nightfall emergency unit offers exceptional light output to minimize fixtures required in typical applications. 120/277V dual primary, 60Hz input for standard operation Standard finish: White Optional damp rating (DR) available ORDERING INFORMATION Example: NF1-WB-15L-WH-G2 Series Power Source LED Wattage Finish Mounting Options (Factory Installed) NF1 LB = AC Only LB Units WH = White JB = J-Box Mount G21 = Self Test / Self Diagnostics WB = With Battery 8L = 8 Watts WM = Wall Mount SEC = Security Lighting / Night Lighting 12L = 12 Watts SM = Surface Mount (Top) DR = Damp Rated WB Units P6 = 6" Pendant Mounting Assembly 10L = 10 Watts P12 = 12" Pendant Mounting Assembly 15L = 15 Watts 1 Available on WB units only SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ARRA 4

specifications Construction HOUSING: Rugged, extruded aluminum housing and canopy plate. LENS: Heat and impact resistant polycarbonate lens resists discoloration. FINISH: Available in white satin enamel finish. illumination Units come with a variety of lamp choices: With battery and remote units can be supplied with LEDs offering 10 watts or 15 watts of light output. Less battery units are offered with LEDs in wattages of 8 or 12 watts. The high-performance LEDs have an expected life of up to 50,000 hours with normal use. Electronics Dual voltage, 120 volt or 277 volt input for standard battery or AC units. Lamps are connected in parallel if one lamp fails, the balance of the lamps will continue to operate. The power supply delivers a regulated current and voltage to LED lamps to optimize lamp life. A momentary test switch and LED charge indicator are included. nickel metal hydride battery (With Battery Units Only) Exitronix sealed nickel metal hydride batteries are maintenance-free with a life expectancy of 15 years. Nickel metal hydride batteries offer several advantages over nickel cadmium; NiMH use positive electrodes of nickel oxyhydroxide (NiOOH), like the NiCd, but the negative electrodes use a hydrogen-absorbing alloy instead of cadmium therefore increasing capacity and energy density. NiMH batteries perform optimally in temperatures ranging from 0-40 C. NiMH batteries are more environmentally-friendly than traditional NiCd or lead acid alternatives as they contain no cadmium or lead. brownout circuit The brownout circuit monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. low voltage disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. guardian self-testing/self-diagnostics (Option: G2) The circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. If a failure is detected, visual status will occur immediately via the multi-colored LEDs. LED indicator(s) will illuminate until fault has been corrected. The Guardian also monitors the transfer circuit as well as performing automatic code compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 12 months. Pathsafe SECURITY/NIGHT LIGHTING (Option: SEC) The Pathsafe option allows the fixture to be used as both an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output when in security lighting mode and when connected to the active building AC supply and wired according to the installation instructions. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell (supplied by others) or other automatic means. damp location rated (Option: DR) Damp location rating ensures the fixture is designed to operate safely in outdoor locations that are protected from the direct elements. Damp location rated fixtures may be installed indoors. Products with damp location ratings are not designed to withstand constant or significant moisture or direct contact with water or steam. installation This Nightfall emergency unit mounts with a standard back plate to the wall or ceiling for traditional installations. Optional pendant mounting or mounting direct to J-box for exposed conduit applications, such as unfinished ceilings are also available. CONFORMANCE TO CODES & STANDARDS The Nightfall Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. Warranty Any component that fails due to manufacturer s defect is guaranteed for 5 years with a separate 5 year pro-rated warranty on the battery. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. spacing guidelines LED Mtg. Ht. Spacing Path of Egress Width 3 Ft. 6 Ft. 10 Ft. 10L 9' 50' 40' 25' 15L 9' 55' 50' 40' Spacing guidelines are designed to achieve a 1 foot-candle average and a 0.1 foot-candle minimum with a 40:1 or less max/min ratio. Guidelines are intended to be used as a design aid and are not a guarantee of code compliance. Manufacturer assumes no responsibility for local requirements or specific project variables. dimensions 5

Nightfall led emergency egress lighting Nf2 ultra mini LED Emergency Lighting Unit Features Outstanding 40-45 foot center-to-center spacing Complete fixture series meets American Recovery & Reinvestment Act of 2009 (ARRA) requirements and Buy American Recovery Act provisions. Ultra compact, low-profile, architectural design Easy to install, snap together design Available in a variety of lamping options ranging from 8-15 watts Pathsafe security or night light option (SEC) available offering incredibly low wattage consumption when compared to traditional fluorescent or incandescent systems during night operation Impact-resistant, polycarbonate shield offers extreme protection External LED status indicator and test button ETL listed 90 minute emergency run time, 24 hour recharge time Universal deep J-Box mounting system This sleek architectural fixture combines a compact design with outstanding performance. At only 5 x 5 in width and height and a 2 profile depth, this unit is the smallest emergency wall pack available. The contoured lens provides an elongated lighting pattern to minimize fixtures required in typical applications. Optional Guardian self-testing/self-diagnostics (G2) available 120/277V dual primary, 60Hz input for standard operation Standard finishes: White Optional damp rating (DR) available ORDERING INFORMATION Example: NF2-WB-15L-WH-G2 Series Power Source LED Wattage Finish NF2 LB = AC Only LB Units WH = White Options (Factory Installed) WB = With Battery 8L = 8 Watts DR = Damp Rated 12L = 12 Watts SEC = Security Lighting / Night Lighting G21 = Self Testing / Self Diagnostics WB Units 10L = 10 Watts 15L = 15 Watts 1 Available on WB units only SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ARRA 6

specifications Construction HOUSING: Precision, low-profile design with all-aluminum housing. LENS: Heat and impact resistant polycarbonate lens resists discoloration. FINISH: Available in white satin enamel finish. illumination Units come with a variety of lamp choices: With battery and remote units can be supplied with LEDs offering 10 watts or 15 watts of light output. Less battery units are offered with LEDs in wattages of 8 or 12 watts. The high-performance LEDs have an expected life of up to 50,000 hours with normal use. Electronics Dual voltage, 120 volt or 277 volt input for standard battery or AC units. Lamps are connected in parallel if one lamp fails, the balance of the lamps will continue to operate. The power supply delivers a regulated current and voltage to LED lamps to optimize lamp life. A momentary test switch and LED charge indicator are included. nickel cadmium battery (With Battery Units Only) Exitronix sealed nickel cadmium batteries are maintenance-free with a life expectancy of 15 years. Nickel cadmium batteries offer high discharge rates and continue to perform in a vast temperature range from 0-40 C. NiCd technology provides long lasting, safe and reliable performance by utilizing the jelly-roll design and allows a Ni Cd cell to deliver a much higher maximum current than an equivalent size alternative battery. As a relatively larger area of the electrode is in contact with the, the internal resistance for an equivalent sized NiCd cell is lower which increases the maximum current that can be delivered. brownout circuit The brownout circuit monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. low voltage disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. guardian self-testing/self-diagnostics (Option: G2) The circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. If a failure is detected, visual status will occur immediately via the multi-colored LEDs. LED indicator(s) will illuminate until fault has been corrected. The Guardian also monitors the transfer circuit as well as performing automatic code compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 12 months. Note: The Guardian option includes a Nickel Metal Hydride battery (NiMH) standard. Nickel metal hydride batteries offer several advantages over nickel cadmium; NiMH use positive electrodes of nickel oxyhydroxide (NiOOH), like the NiCd, but the negative electrodes use a hydrogen-absorbing alloy instead of cadmium therefore increasing capacity and energy density. NiMH batteries perform optimally in temperatures ranging from 0-40 C. NiMH batteries are more environmentally-friendly than traditional NiCd or lead acid alternatives as they contain no cadmium or lead. Pathsafe SECURITY/NIGHT LIGHTing (Option: SEC) The Pathsafe option allows the fixture to be used as both an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output when in security lighting mode and when connected to the active building AC supply and wired according to the installation instructions. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell (supplied by others) or other automatic means. damp location rated (Option: DR) Damp location rating ensures the fixture is designed to operate safely in outdoor locations that are protected from the direct elements. Damp location rated fixtures may be installed indoors. Products with damp location ratings are not designed to withstand constant or significant moisture or direct contact with water or steam. installation This Nightfall emergency unit is traditionally wall mounted, and requires the rough in of a standard deep J-box with a 1 ½ extension ring, supplied by others. CONFORMANCE TO CODES & STANDARDS The Nightfall Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. Warranty Any component that fails due to manufacturer s defect is guaranteed for 5 years with a separate 5 year pro-rated warranty on the battery. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. spacing guidelines LED Mtg. Ht. Spacing Path of Egress Width 3 Ft. 6 Ft. 10 Ft. 10L 8½ 40' 35' 25' 15L 8½ 45' 40' 35' Spacing guidelines are designed to achieve a 1 foot-candle average and a 0.1 foot-candle minimum with a 40:1 or less max/min ratio. Guidelines are intended to be used as a design aid and are not a guarantee of code compliance. Manufacturer assumes no responsibility for local requirements or specific project variables. dimensions 7

Nightfall Nf3 outdoor compact LED Emergency Lighting led emergency egress lighting Features Outstanding 40 foot center-to-center spacing Complete fixture series meets American Recovery & Reinvestment Act of 2009 (ARRA) requirements and Buy American Recovery Act provisions. Attractive, low-profile, streamlined design Easy to install, snap together design Available in a variety of lamping options ranging from 8-15 watts Pathsafe security or night light option (SEC) available offering incredibly low wattage consumption when compared to traditional fluorescent or incandescent systems during night operation Contoured prismatic polycarbonate lens for optimal light output and protection Suitable for wet or damp location External LED status indicator and test button ETL listed 90 minute emergency run time, 24 hour recharge time Universal J-Box mounting system Optional Guardian self-testing/self-diagnostics (G2) available Extremely compact, die-cast emergency fixture designed to optimize light output for outdoor locations. This Nightfall fixture can also be installed in interior, hard-use applications such as gymnasiums or hallways in multifamily complexes. Optional cold weather package (-40 C to 30 C) 120/277V dual primary, 60Hz input for standard operation Standard finishes: White and bronze ORDERING INFORMATION Example: NF3-WB-15L-WH-G2 Series Power Source LED Wattage Finish NF3 LB = AC Only LB Units WH = White Options (Factory Installed) G21 = Self Test / Self Diagnostics WB = With Battery 8L = 8 Watts BR = Bronze SEC2 = Security Lighting / Night Lighting 12L = 12 Watts PC/G21 = Photocontrol / Self Diagnostics WB Units CL = Cold Location Package 10L = 10 Watts PM20 = 20" Pole Mounting Assembly 15L = 15 Watts PM36 = 36" Pole Mounting Assembly PM96 = 96" Pole Mounting Assembly 1 2 Available on WB units only Required with CL option when operating at -40 C SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ARRA 8

specifications Construction HOUSING: Precision, low-profile design with die-cast aluminum housing. LENS: Heat and impact resistant polycarbonate lens resists discoloration. FINISH: Available in bronze or white satin enamel finish. illumination Units come with a variety of lamp choices: With battery and remote units can be supplied with LEDs offering 10 watts or 15 watts of light output. Less battery units are offered with LEDs in wattages of 8 or 12 watts. The high-performance LEDs have an expected life of up to 50,000 hours with normal use. Electronics Dual voltage, 120 volt or 277 volt input for standard battery or AC units. Lamps are connected in parallel if one lamp fails, the balance of the lamps will continue to operate. The power supply delivers a regulated current and voltage to LED lamps to optimize lamp life. A momentary test switch and LED charge indicator are included. nickel cadmium battery (With Battery Units Only) Exitronix sealed nickel cadmium batteries are maintenance-free with a life expectancy of 15 years. Nickel cadmium batteries offer high discharge rates and continue to perform in a vast temperature range from 0-40 C. NiCd technology provides long lasting, safe and reliable performance by utilizing the jelly-roll design and allows a Ni Cd cell to deliver a much higher maximum current than an equivalent size alternative battery. As a relatively larger area of the electrode is in contact with the, the internal resistance for an equivalent sized NiCd cell is lower which increases the maximum current that can be delivered. brownout circuit The brownout circuit monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. low voltage disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. Wet Location Rated Wet location rated fixtures can be used in applications where moderate contact with water can be expected. Wet location rated products are designed to be reasonably watertight; they require a seal around the base, canopy, or bracket to protect the electrical service from moisture. guardian self-testing/self-diagnostics (Option: G2) The circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. If a failure is detected, visual status will occur immediately via the multi-colored LEDs. LED indicator(s) will illuminate until fault has been corrected. The Guardian also monitors the transfer circuit as well as performing automatic code compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 12 months. Pathsafe SECURITY/NIGHT LIGHTing (Option: SEC) The Pathsafe option allows the fixture to be used as both an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output when in security lighting mode and when connected to the active building AC supply and wired according to the installation instructions. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell (supplied by others) or other automatic means. Cold Location Package (Option: CL) This Nightfall emergency fixture with battery has an operating temperature range of -20 C (-4 F) to 40 C (104 F). By adding the Cold Location Package, the overall operating temperature is altered to -40 C (-40 F) to 30 C (86 F). NOTE: Pathsafe SECURITY LIGHTING OPTION (SEC) IS REQUIRED FOR OPERATION AT -40 C. installation This Nightfall emergency unit can be surface mounted utilizing a universal j-box mounting pattern and gasket, or by using the conduit entry point at the top of the fixture. CONFORMANCE TO CODES & STANDARDS The Nightfall Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. Warranty Any component that fails due to manufacturer s defect is guaranteed for 5 years with a separate 5 year pro-rated warranty on the battery. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. spacing guidelines LED Mtg. Ht. Spacing Path of Egress Width 3 Ft. 6 Ft. 10 Ft. 10L 8½ 40' 30' 20' 15L* 8½ 40' 35' 30' * Projection from building: 30 Feet Spacing guidelines are designed to achieve a 1 foot-candle average and a 0.1 foot-candle minimum with a 40:1 or less max/min ratio. Guidelines are intended to be used as a design aid and are not a guarantee of code compliance. Manufacturer assumes no responsibility for local requirements or specific project variables. dimensions 9

Nightfall led emergency egress lighting Nf5 outdoor linear LED Emergency Lighting Features Illuminates a uniform 12 x 25 area providing safe and effective outdoor emergency egress lighting Complete fixture series meets American Recovery & Reinvestment Act of 2009 (ARRA) requirements and Buy American Recovery Act provisions. Attractive, low-profile, linear design Available in lamping options 10 or 20 watts Pathsafe security or night light option (SEC) available offering incredibly low wattage consumption when compared to traditional fluorescent or incandescent systems during night operation Rugged steel diffuser lens for optimal light output and protection Suitable for wet or damp location - IP66 rated External LED status indicator and test button This dramatically compact and architecturally pleasing Nightfall Linear Outdoor fixture provides amazing emergency and normal lighting for over-door or other outdoor applications. Manufactured in extruded aluminum, the lamp housing and canopy are available in brushed aluminum or white finishes for universal wall or ceiling installations. ETL listed 90 minute emergency run time, 24 hour recharge time Universal deep J-Box mounting system Optional Guardian self-testing/self-diagnostics (G2) available 120/277V dual primary, 60Hz input for standard operation Standard finishes: White and brushed aluminum ORDERING INFORMATION Example: NF5-WB-10L-WH-G2 Series Power Source LED Wattage Finish Options (Factory Installed) NF5 LB = AC Only LB Units WH = White G22 = Self Testing / Self Diagnostics WB = With Battery 10L = 10 Watts BA = Brushed Aluminum SEC = Security Lighting / Night Lighting 20L1 = 20 Watts MTM3 = Mullion Top Mount Canopy WB Units MWM3 = Mullion Wall Mount Canopy 10L = 10 Watts On 20 watt units, width extends to 21" Available on WB units only 3 Mullion mounting includes 2.5" x 5" mounting canopy with remote power supply 1 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ARRA 10

specifications Construction HOUSING: Precision, low-profile design with die-cast aluminum housing. LENS: Heat and impact resistant polycarbonate lens resists discoloration. FINISH: Available in white enamel or brushed aluminum finish. illumination With battery and remote units can be supplied with LEDs offering 10 watts of light output. Less battery units are offered with LEDs in wattages of 10 or 20 watts. The high-performance LEDs have an expected life of up to 50,000 hours with normal use. Electronics Dual voltage, 120 volt or 277 volt input for standard battery or AC units. Lamps are connected in parallel - if one lamp fails, the balance of the lamps will continue to operate. The power supply delivers a regulated current and voltage to LED lamps to optimize lamp life. A momentary test switch and LED charge indicator are included. nickel metal hydride battery (With Battery Units Only) Exitronix sealed nickel metal hydride batteries are maintenance-free with a life expectancy of 15 years. Nickel metal hydride batteries offer several advantages over nickel cadmium; NiMH use positive electrodes of nickel oxyhydroxide (NiOOH), like the NiCd, but the negative electrodes use a hydrogen-absorbing alloy instead of cadmium therefore increasing capacity and energy density. NiMH batteries perform optimally in temperatures ranging from 0-40 C. NiMH batteries are more environmentally-friendly than traditional NiCd or lead acid alternatives as they contain no cadmium or lead. brownout circuit The brownout circuit monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. low voltage disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. IP66 Rated IP66 rating ensures that the product can be installed in outdoor applications where significant water or dust may come in contact with the fixture. IP66 rated fixtures are designed to perform in hose down applications. guardian self-testing/self-diagnostics (Option: G2) The circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. If a failure is detected, visual status will occur immediately via the multi-colored LEDs. LED indicator(s) will illuminate until fault has been corrected. The Guardian also monitors the transfer circuit as well as performing automatic code compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 12 months. Pathsafe SECURITY/NIGHT LIGHTing (Option: SEC) The Pathsafe option allows the fixture to be used as both an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output when in security lighting mode and when connected to the active building AC supply and wired according to the installation instructions. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell (supplied by others) or other automatic means. installation For wall or ceiling mount applications, the standard Linear Nightfall emergency unit requires the rough in of a standard deep J-box with a 1 ½ extension ring, supplied by others. For mullion top or wall mount installations of the Linear Nightfall unit, a remote power supply is included to house the electronic components and power the remotely installed fixture. The mullion-mounted Linear unit should be installed within 100 ft of remote power supply for typical applications. CONFORMANCE TO CODES & STANDARDS The Nightfall Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. Warranty Any component that fails due to manufacturer s defect is guaranteed for 5 years with a separate 5 year pro-rated warranty on the battery. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. spacing guidelines Spacing guidelines are designed to achieve a 1 foot-candle average and a 0.1 foot-candle minimum with a 40:1 or less max/min ratio. Guidelines are intended to be used as a design aid and are not a guarantee of code compliance. Manufacturer assumes no responsibility for local requirements or specific project variables. dimensions 11

Nightfall NfDL1 led emergency egress lighting RECESSED DOWNLIGHT LED Emergency Lighting Features Outstanding 50-55 foot center-to-center spacing Complete fixture series meets American Recovery & Reinvestment Act of 2009 (ARRA) requirements and Buy American Recovery Act provisions. Compact, flush-mount, 4 recessed down light Available in a variety of lamping options ranging from 8-15 watts Pathsafe security or night light option (SEC) available offering incredibly low wattage consumption when compared to traditional fluorescent or incandescent systems during night operation ETL listed 90 minute emergency run time, 24 hour recharge time Optional Guardian self-testing/self-diagnostics (G2) available With spacing up to 55 ft in 9 ft ceilings, this 4 Nightfall recessed downlight is our most efficient recessed emergency fixture for new construction, it blends in perfectly with general lighting without affecting the appearance of ceiling layouts. 120/277V dual primary, 60Hz input for standard operation Standard finishes: White Optional damp rating (DR) available ORDERING INFORMATION Example: NFDL1-WB-15L-WH-G2 Series Power Source LED Wattage Finish NFDL1 LB = AC Only LB Units WH = White Options (Factory Installed) WB = With Battery 8L = 8 Watts SEC = Security Lighting / Night Lighting 12L = 12 Watts DR = Damp Rated G21 = Self Diagnostics WB Units 10L = 10 Watts 15L = 15 Watts 1 Available on WB units only SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ARRA 12

specifications Construction HOUSING: 4 trim ring with standard galvanized steel can and back plate. LENS: Heat and impact resistant polycarbonate lens resists discoloration. FINISH: Available with white enamel finish. illumination Units come with a variety of lamp choices: With battery and remote units can be supplied with LEDs offering 10 watts or 15 watts of light output. Less battery units are offered with LEDs in wattages of 8 or 12 watts. The high-performance LEDs have an expected life of up to 50,000 hours with normal use. Electronics Dual voltage, 120 volt or 277 volt input for standard battery or AC units. Lamps are connected in parallel if one lamp fails, the balance of the lamps will continue to operate. The power supply delivers a regulated current and voltage to LED lamps optimizing lamp life. A momentary test switch and LED charge indicator are included. nickel cadmium battery (With Battery Units Only) Exitronix sealed nickel cadmium batteries are maintenance-free with a life expectancy of 15 years. Nickel cadmium batteries offer high discharge rates and continue to perform in a vast temperature range from 0-40 C. NiCd technology provides long lasting, safe and reliable performance by utilizing the jelly-roll design and allows a Ni Cd cell to deliver a much higher maximum current than an equivalent size alternative battery. As a relatively larger area of the electrode is in contact with the, the internal resistance for an equivalent sized NiCd cell is lower which increases the maximum current that can be delivered. brownout circuit The brownout circuit monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. low voltage disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. guardian self-testing/self-diagnostics (Option: G2) The circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. If a failure is detected, visual status will occur immediately via the multi-colored LEDs. LED indicator(s) will illuminate until fault has been corrected. The Guardian also monitors the transfer circuit as well as performing automatic code compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 12 months. Pathsafe SECURITY/NIGHT LIGHTing (Option: SEC) The Pathsafe option allows the fixture to be used as both an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output when in security lighting mode and when connected to the active building AC supply and wired according to the installation instructions. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell (supplied by others) or other automatic means. damp location rated (Option: DR) Damp location rating ensures the fixture is designed to operate safely in outdoor locations that are protected from the direct elements. Damp location rated fixtures may be installed indoors. Products with damp location ratings are not designed to withstand constant or significant moisture or direct contact with water or steam. installation This Nightfall emergency unit is installed as a recessed housing with trim for new construction applications. This new construction emergency down light unit is supplied with integral bar hangers, standard recessed can, back plate and lensed trim. CONFORMANCE TO CODES & STANDARDS The Nightfall Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. Warranty Any component that fails due to manufacturer s defect is guaranteed for 5 years with a separate 5 year pro-rated warranty on the battery. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. spacing guidelines LED Mtg. Ht. Spacing Path of Egress Width 3 Ft. 6 Ft. 10 Ft. 10L 9 50' 40' 25' 15L* 9 55' 50' 40' Spacing guidelines are designed to achieve a 1 foot-candle average and a 0.1 foot-candle minimum with a 40:1 or less max/min ratio. Guidelines are intended to be used as a design aid and are not a guarantee of code compliance. Manufacturer assumes no responsibility for local requirements or specific project variables. dimensions 13

Nightfall NfDL2 Remodel led emergency egress lighting RECESSED DOWNLIGHT LED Emergency Lighting Features Outstanding 50-55 foot center-to-center spacing Complete fixture series meets American Recovery & Reinvestment Act of 2009 (ARRA) requirements and Buy American Recovery Act provisions. Compact, flush-mount, 4 recessed down light trim for remodel housing Available in a variety of lamping options ranging from 8-15 watts Pathsafe security or night light option (SEC) available offering incredibly low wattage consumption when compared to traditional fluorescent or incandescent systems during night operation ETL listed 90 minute emergency run time, 24 hour recharge time With spacing up to 55 ft in 9 ft ceilings, this 4 Nightfall recessed downlight is our most efficient recessed emergency fixture for remodel applications, it blends in perfectly with general lighting without affecting the appearance of ceiling layouts and is ideal for remodel applications. Optional Guardian self-testing/self-diagnostics (G2) available 120/277V dual primary, 60Hz input for standard operation Standard finishes: White Optional damp rating available ORDERING INFORMATION Example: NFDL2-WB-15L-WH-DR Series Power Source LED Wattage Finish NFDL2 LB = AC Only LB Units WH = White Options (Factory Installed) WB = With Battery 8L = 8 Watts SEC = Security Lighting / Night Lighting 12L = 12 Watts DR = Damp Rated G21 = Self Test / Self Diagnostics WB Units 10L = 10 Watts 15L = 15 Watts 1 Available on WB units only SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ARRA 14

specifications Construction HOUSING: 4 trim ring with standard galvanized steel can and back plate. LENS: Heat and impact resistant polycarbonate lens resists discoloration. FINISH: Available with white enamel finish. illumination Units come with a variety of lamp choices: With battery and remote units can be supplied with LEDs offering 10 watts or 15 watts of light output. Less battery units are offered with LEDs in wattages of 8 or 12 watts. The high-performance LEDs have an expected life of up to 50,000 hours with normal use. Electronics Dual voltage, 120 volt or 277 volt input for standard battery or AC units. Lamps are connected in parallel if one lamp fails, the balance of the lamps will continue to operate. The power supply delivers a regulated current and voltage to LED lamps to optimize lamp life. A momentary test switch and LED charge indicator are included. nickel metal hydride battery (With Battery Units Only) Exitronix sealed nickel metal hydride batteries are maintenance-free with a life expectancy of 15 years. Nickel metal hydride batteries offer several advantages over nickel cadmium; NiMH use positive electrodes of nickel oxyhydroxide (NiOOH), like the NiCd, but the negative electrodes use a hydrogen-absorbing alloy instead of cadmium therefore increasing capacity and energy density. NiMH batteries perform optimally in temperatures ranging from 0-40 C. NiMH batteries are more environmentally-friendly than traditional NiCd or lead acid alternatives as they contain no cadmium or lead. brownout circuit The brownout circuit monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. low voltage disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. guardian self-testing/self-diagnostics (Option: G2) The circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. If a failure is detected, visual status will occur immediately via the multi-colored LEDs. LED indicator(s) will illuminate until fault has been corrected. The Guardian also monitors the transfer circuit as well as performing automatic code compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 12 months. Pathsafe SECURITY/NIGHT LIGHTing (Option: SEC) The Pathsafe option allows the fixture to be used as both an emergency lighting fixture and security/night lighting fixture. Models with battery back-up and the Pathsafe option will operate at 50-70% output when in security lighting mode and when connected to the active building AC supply and wired according to the installation instructions. The security lighting circuit is independent of emergency lighting and may be switched manually by exterior photocell (supplied by others) or other automatic means. damp location rated (Option: DR) Damp location rating ensures the fixture is designed to operate safely in outdoor locations that are protected from the direct elements. Damp location rated fixtures may be installed indoors. Products with damp location ratings are not designed to withstand constant or significant moisture or direct contact with water or steam. installation This Nightfall emergency unit is installed as a recessed housing with trim for remodel applications. This retrofit emergency down light unit is supplied with standard remodel recessed can and lensed trim. CONFORMANCE TO CODES & STANDARDS The Nightfall Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. Warranty Any component that fails due to manufacturer s defect is guaranteed for 5 years with a separate 5 year pro-rated warranty on the battery. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. spacing guidelines LED Mtg. Ht. Spacing Path of Egress Width 3 Ft. 6 Ft. 10 Ft. 10L 9 50' 40' 25' 15L* 9 55' 50' 40' Spacing guidelines are designed to achieve a 1 foot-candle average and a 0.1 foot-candle minimum with a 40:1 or less max/min ratio. Guidelines are intended to be used as a design aid and are not a guarantee of code compliance. Manufacturer assumes no responsibility for local requirements or specific project variables. dimensions 15

1911 West Parkside Lane Phoenix, Arizona 85027 800.533.3948 Fax: 623.580.8948 www.barronltg.com 16