ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR

Similar documents
SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

ROP-63 & ROP-63H MANUAL CALL POINTS

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

DUR-4047 WIRELESS RADIO UNIVERSAL SMOKE OPTICAL DETECTOR

IGNIS 1520M AUTOMATIC FIRE EXTINGUISHING SYSTEM CONTROLLER

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Operating instructions for the radio heat detector GS412

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Datasheet CALYPSO II R. Interlinkable smoke alarm device

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

User guide. for smoke detector

5000 INSTALLATION GUIDE

Operating Instructions Version 1.2

Patio Heater Model No. GM and GM

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

SMOKE User Manual. NE v2.0

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

ATM Lighting sp. z o.o

Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

OH110, OP110, HI110 Automatic fire detectors

Series 65 Product Guide MAN 3036

Battery Powered Smoke & Heat Alarms Ei600 Series Instructions

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Operating instructions for the wireless smoke alarm detector type: GS558

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

USER MANUAL. Galil 8-C Closed-back Ceiling Speakers MODEL: P/N: Rev 2

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

RMS-I-DE-01 Smoke Detector

Instructions for the fan motor control system with integrated wiring terminals SILVER C

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Installation and Operating Instruction

LASER ASPIRATED SMOKE DETECTOR

DICTATOR Hold-Open Systems for Hazardous Areas

Installation Manual Local Ventilation System with Heat Recovery Type e² and e² short

PHOTOELECTRIC REFLECTIVE BEAM DETECTOR MODEL SRA-ET. Mounting Guidelines

mumbi Heat Detector m-hm100 User manual

CENTRAL AIR CONDITIONER SPLIT SYSTEM

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

FIRE DETECTION AND ALARM SYSTEMS

Intelligent Detection Devices

FIRE DETECTION AND ALARM SYSTEMS

Battery Powered Smoke & Heat Alarms EIB600 Series

The new detector from Rafiki

2-ZONE EASYFIT INTRUDER ALARM

Analogue addressable devices

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Mounting Instructions for Genius Hx

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

First Alert Detector Error In Basement Please See Manual

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

OH720, OP720, HI720, HI722

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

KM300 Carbon Monoxide Detection System Installation Manual

Reflective Beam Smoke Detector

1 Introducing Eve Smoke

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR DÉTECTEUR DE FUMÉE PHOTOÉLECTRIQUE SUPERVISÉ SANS FILS. Model: EL-2703

Smoke Detector and Siren. Manual

JUNEAU JUN. 08/51193/0 Issue 0

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE


SMOKE & HEAT DETECTOR

HART XL High Sensitivity Smoke Detection

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Smoke Vent Control Panel PCB4 V4 Installation Manual

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Hotte de cuisine Cooker hood KuchyÚsk digesto Emhætte til køkken Dunstabzugshaube

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Installation Instruction Venturi-Air Duct Kit. (Part No. S )

LASER ASPIRATED SMOKE DETECTOR

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

Protecting you and your home

OPTICAL SMOKE DETECTOR Model: SPD-KADET

EWS3 WIRELESS INDOOR SIREN

Hotte de cuisine Cooker hood Emhætte til køkken Dunstabzugshaube

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

RE-PR3-E-27 3-Phase Panel Mount 27kW

Photoelectric Smoke Alarm

Instruction Manual. Electronic gas and smoke detector GRM

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Transcription:

ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR Installation and Maintenance Manual IK E289 003GB Issue 1A

IK-E322-001GB 2 The ADR 20N residential self contained optical smoke detector covered by this manual, complies with the requirements of the following European Union directives: CPD 89/106/EWG on construction materials; EMC 2004/108/WE on electromagnetic compatibility. The ADR 20N optical smoke detector has been approved with the EC Certificate of Conformity No. 1438/CPD/0145, issued by the Scientific and Research Centre for Fire Protection (CNBOP) Józefów, Poland, a EU notified authority No. 1438, confirming its compliance with the requirements of PN EN 14604: 2006 standard. The certificate can be download form www.polon alfa.pl web site. 1438 Polon Alfa Spółka z ograniczoną odpowiedzialnością Sp. k. 155, Glinki Street, PL 85 861 Bydgoszcz, POLAND 08 1438/CPD/0145 EN 14604 ADR 20N Self contained Smoke Detector Application fire security Technical data IK E289 003GB manual Read the manual carefully before assembling and operation of the detector. Any nonconformity with the instructions contained in the manual may be harmful or may cause violation of the law in force POLON ALFA shall not bear responsibility for any harms resulted from the unit application discordantly to the requirements of this instruction. According to the European Union regulations it is forbidden to dispose the waste equipment marked with the sign of a crossed container (as shown beside) to industrial scrap heap. Any waste product, unsuitable for further use, shall be passed to a waste electric and electronic equipment collection point. Delivering the waste equipment to special collection points for utilization and recycling reduces an adverse impact of harmful components used in the device production upon environment and human health. The ADR 20N detector mass (without a battery): 0.125 kg NOTE: The manufacturer reserves the right to change specifications of products at any time without prior notice

IK-E322-001GB 3 1 PURPOSE The ADR 20N optical smoke detector is designed for detection of a visible smoke that is concurrent with most fire combustion. It is dedicated to monitor residential facilities, cellars, garages, attics, etc. The detector is battery operated using a replaceable 9V 6F22 battery mounted inside its casing. It is possible to inter connect detectors with a two core cable creating a detecting network detection of a fire by one detector activates an alarm signal in other detectors in the supervised premises. 2 TECHNICAL SPECIFICATIONS Power supply 9 V 6F22 battery (not included) Quiescent current < 10 µa Operation temperature range from 10 o C to +55 o C Relative humidity 95 % at 40 o C Detector mass (without battery) 0.13 kg Dimensions (with base) Ø112 x 57 mm Sensitivity to test aerosol acc. to PN EN 14604:2006 standard m = 0.20 0.38 Audio alarm volume > 85 db at 3 m distance Battery operation life 1 3 years (depending on type) 3 SAFETY CONDITIONS 3.1 Repairs and maintenance Any repair must be carried out by the manufacturer. POLON ALFA bears no responsibility for the operation of any apparatus being serviced and repaired by unauthorised personnel. 3.2 Works at height Any detector installation works carried out at height must be executed with particular care utilising tools and machinery in good working condition. Special attention shall be given to the stability of ladders, platforms, etc. Any electric tool shall be used strictly obeying the safety rules specified in the manufacturer instruction manuals. 3.3 Anti dusting eye protection It is obligatory to use protective anti dusting glasses and masks during detector installation works that produce high amount of dust, such as hole drilling for detector base mounting on ceilings. 4 GENERAL DESCRIPTIONS The ADR 20N smoke detector consists of the following main parts: base (1), bottom (9) with an electronic circuit and a labyrinth and a casing (6). An optical assembly and an acoustic signalling device

IK-E322-001GB 4 are installed inside the bottom. The casing encloses a wire grid that prevents irruption of small insects or pieces of dirt. Fig. 1 The bottom is fixed to the casing with two screws (10). Two small devices protrude from the casing: a test button (4) and an illuminating LED (8) that indicates the detector mode. Fragments of a printed

IK-E322-001GB 5 circuit board (PCB) with contact pins are visible from the bottom side. These contact pins hold a connector (11) to interconnect several detectors in a network. 5 INSTALLATION The detectors are recommended to be installed in all rooms exposed to a high fire hazard level. They may be mounted in hallways, staircases as well as in passages between rooms endangered by a fire occurrence. It is recommended to install the detector on ceilings, leaving at least 20 cm of unobstructed space from walls or other elements that may hamper free smoke access to the detector. Two holes (with 72 mm spacing) should be drilled in order to install extension anchor bolts fixing the detector to the ceiling. In case the detectors are intended to work in a network, they should be linked all detector GND clamps must be interconnected; the same concerns the I/O clamps. When cables are led under the wall plaster (semi flush mounting), the base should be drilled in its centre; in case of on plaster cable leading (surface mounting), the hole should be drilled in the base side wall (suggested hole locations are shown on Fig. 1) leaving the minimum distance from the bottom. The cables should be placed into the holes and then the base should be fixed in the place intended for installation. The detectors may be interconnected using a typical telecommunication PVC insulated cable of 0.12 0.5 mm 2 cross section (0.4 0.9 mm diameter). Two wires may be connected to one contact (wire and resistor endings). It is allowed to use different size wires (within 0.4 0.9 mm range) in one contact. The minimum length of the wire protruding from the base is 5 cm. Bare (un insulated) ends of wires (at least 8 mm long) should be pushed in the connector taken out from the base as it is shown on Fig. 2. The clamps of the connector will clench the wires automatically. Fig. 2 A removal of a wire from the connector is possible after pressing down an orange blocking push button with a finger nail. The connector with the wires should be pushed on the contact pins protruding from the detector. The battery should be connected and inserted so that the red blocking plate pulls back according to the Figure 3. The detector operation should be checked by pressing down the test push button for few seconds. The test result is positive when a LED flashes several times and subsequently an acoustic signal is heard. The inspected detector can be installed in the base turning it clockwise until the catches snap.

IK-E322-001GB 6 Fig. 3 6 PRINCIPLES OF OPERATION The detector monitoring activity begins when a battery power supply is connected. An information about the detector mode is communicated by acoustic and optical signals as per the following table: Supervision, smoke detection Detector mode Modulated audio signal LED flashing Alarm after smoke detection x x Short audio signal 40 s interval LED flashing 40 s interval Low power supply voltage x x Detector testing with the TEST button x x x Fault x In case a factor that causes a particular mode decays, the detector automatically returns to its supervision mode. Depending on the type of a battery used, the detector operation period may vary: ordinary batteries min. 1 year; the detector will work normally for at least 30 days since the first low battery signal has been transmitted alkaline batteries min. 2 years; low battery signal for min. 30 days lithium batteries min. 3 years; low battery signal for min. 60 days. Frequent detector tests and its activation inspections will result in the operation period shortening.

IK-E322-001GB 7 7 MAINTENANCE INSTRUCTIONS In case of dust accumulation inside the measuring chamber, which may be a result of a long term device, the detector sensitivity level will increase up to evoking false alarms. It is recommended to clean the optical module (i.e. the labyrinth and lenses of both transmitting diode and receiving photodiode which are placed within the labyrinth) every year. In order to carry the cleaning process out, it is necessary: remove the detector from its base turning it counter clockwise and taking it off; disconnect the connector (11); remove two screws (10) fastening the bottom (9) to the casing (6) of the detector; take the casing off; bend softly the catches that hold the labyrinth (5) and take it out; using soft brush clean carefully the labyrinth, the hollows where the diodes are placed as well as the metal cover from the side of the labyrinth; in case such cleaning is not effective, it is allowed to wash the labyrinth with warm water with an addition of washing up liquid; after cleaning and drying no water stain may be left on the labyrinth internal surfaces. After cleaning reassemble the detector in the following order: check whether the metal cover does not conceal the acoustic signalling device opening; press the labyrinth down until its catches snap; in this position the printed circuit board should closely adhere the bottom edges, the labyrinth should be tightly fastened in upright position (with no bending); place the module into the casing so that the LED and the testing button poke out above the casing surface; fasten the module to the casing with two screws; connect a battery and check the detector operation; install the detector inside the base. 8 NOTES A supplying battery is not included in a standard detector package it should be ordered separately. The ADR 20N detectors do not contain any radioactive material. It should be avoided to install the detectors in draughty places. They should not be mounted above stoves, kettles and similar places where smoke or water vapour may occur. IK E289 003GB/10.2008/12.2011