Thermostatic Control Valves

Similar documents
High Capacity Instantaneous Steam Fired Water Heater

TEMPERATURE CONTROLLERS

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

The Expertise for Components

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Exhaust Gas Heat Exchangers

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Packaged Semi-Instantaneous Steam Fired Water Heater

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

CD-33/CD-33S Controlled Disc Steam Traps

Applications. Features & Benefits ULTRASONIC WATER METER

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

BRINGING WARMTH TO YOUR WORLD

Taco 00 Series Cartridge Circulators

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

RA15/6T & TB Conversion Valve

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

THERMOSTATIC VALVES HUEGLI TECH

Packaged Steam Fired Water Heater

Refrigerated Air Dryer

MFP14 Automatic pumps. for condensate and other industrial fluids

The A-series Eletta Flow Monitor with local indication and analog output

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

All All kin kin ds of Co t n r t ol V ol V v al es v Self-Actu Act a u ti a ng ng e Pr ss e ur ss e R egu e R

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

The Replacement Motor & Fan Specialists

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Thermostatic mixing valves with replaceable cartridge for centralized systems

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

ASME Packaged Indirect Fired Water Heater

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

M7100 Pressure Transducer

Technical Specification VFD

Semi-Instantaneous Indirect Fired Water Heater

Balancing & Control. Frese SIGMA Compact. Dynamic Balancing Valve

MFP14 Automatic pumps for condensate and other industrial fluids

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Air Cooled Oil Coolers

TECHNICAL DATA. Wet 26a. February 22, 2009

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

FLAME SAFETY DEVICES THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT ARRESTERS DEFLAGRATION // ATEX CERTIFIED

YALE Site Specifications AIR VENT SCHEDULE

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Refrigerated Air Dryer

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Dual Pressure Controls

Hydronic Product & Application Catalog

THERMODYNAMIC STEAM TRAP

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

features Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Refrigerated Air Dryers

Cooler Range. For use with AESSEAL Seal Support Systems.

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

CLOSED COUPLED CENTRIFUGAL PUMPS

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

13-1. Temperature Regulator

Compressors, Chillers & Condensers

The CAST-X 2500 is our most compact dual-tube model, a powerful and versatile mid-sized heater.

Liquid Drainers LIQUID DRAINERS

Tepid Water Delivery System

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Flow Control for Fire Protection

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

TECHNICAL DATA OBSOLETE

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Honeywell Control Valve. HFP Asia Pacific

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Boiler System Expansion Tanks

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

UNIVERSAL SOLVENT HEATER

Transcription:

Thermostatic ontrol Valves Model Typical applications Lubricating oil temperature control Jacket temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications oiler inlet temperature control o-generation, cooling towers Temperature mixing or diverting Engine and compressor cooling system Valve Range Key benefits No external power source required - simple, low cost installation No user setting needed - fit and forget solution Small number of parts - simple maintenance and low cost of ownership Robust design capable of high vibration and shock applications Easy installation, operates in any mounting position utomatic self-sensing control with positive proportional valve action Key features Flow rates of.4-2m /hr (6-54 US gpm) ombinations available: Housings in cast iron, aluminum, bronze, carbon steel, stainless steel DN5 - D40 ( /2 to /2 ) pipe sizes Threaded and flanged connections Tamper-proof temperature settings from 8 to (65 F to 25 F) Pressure ratings up to 72 bar (050 psi) ccreditations available PED Suitable for Group & 2 liquids (Ensure materials are compatible) TEX 2 G X omplies with all relevant EU directives Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 www.amot.com

Thermostatic ontrol Valves - Model ontents Overview... pplications... 4 Valve haracteristics... 4 Pressure drop... 4 Flow coefficient... 5 Temperature & element characteristics... 7 type and seal material... 7 How to order... 6 Service kits... 8 Specification...0 Weights... 0 Dimensions... Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 2

Thermostatic ontrol Valves - Model Overview MOT model thermostatic valves are available in a wide selection of sizes and settings to fill a multitude of fluid temperature control requirements. These valves may be mounted in any position and use the proven expanding wax principle to actuate the -way temperature element assemblies. The model valves may be used for diverting or mixing service. They make vailable housing materials ast iron luminum ronze Steel Stainless steel very economical temperature limiting valves to prevent scalding in home, motel or hotel hot water supply systems. Radiant heating systems can use these valves in limiting water temperature to prevent surface cracking and over-heating of plastic piping. Other applications include electronic and battery cooling circuits, pump temperature relief valves etc. Seal materials una-n/nitrile Viton Neoprene materials ronze, brass and stainless steel Nickel plated/stainless steel Stainless steel Leak holes In some applications, it is necessary to have leak holes drilled in the element to ensure a small flow between ports and. Leak holes are available in sizes ranging from 0.8mm to 6.mm ( /2 to /4 ). Please contact MOT to determine the hole size required for specific applications. Temperature settings wide selection of element materials, seals and temperatures are available. Follow the equipment manufacturers guidelines for heating/cooling systems. Temperature settings are available from 8 to (65 F to 25 F). Refer to the Temperature & haracteristics table on page 6 for specific temperature settings. In general the temperature quoted is the nominal operating temperature in diverting mode on water systems. For long life, MOT valves should not be operated continuously at temperatures in excess of 4 (25 F) of their maximum continuous rating. If this condition is anticipated then consult MOT for suitable alternatives. For mixing and oil circuits the temperature may be one to two degrees higher due to flow, viscosity and other system parameters. s and seals are available in a variety of materials. These materials are suitable for most applications. Please contact MOT for material compatibility information. Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page

pplications Thermostatic ontrol Valves - Model Diverting pplications When valves are used for diverting service, the inlet is Port (temperature sensing port), with Port being connected to the cooler, and Port connected to the cooler by-pass line. Mixing pplications When valves are used for mixing service, Port is the cold fluid inlet port from the cooler, Port is the hot by-pass fluid inlet, and Port the common outlet. Port is the temperature sensing port and will mix the hot and cold fluids in the correct proportion so as to produce the desired outlet temperature leaving Port. 2-way Water Saving pplications Valve as shown maintains minimum flow through cooler to conserve water. Requires internal leak hole to permit small flow for sensing. Heat load MOT thermostat Heat removal ooler Heat load MOT thermostat Heat removal ooler Heat load Pump Port blocked Pump Valve characteristics Pump Pressurre Drop (ar) Pressure drop (Metric units) 0.65 0.60 0.55 0.50 0.45 0.40 0.5 0.0 0.25 0.20 0.5 0.0 0.05 MOT thermostatic valves are designed to produce minimal pressure drop. The normal recommendation in sizing the valves is to select a pressure drop between 0.4 to 0.5 ar (2 and 7 PSI). SE 40 oil at 0 F SE 20 oil at 0 F Water - Size s s s s s s s s s /2 L 0. 0.6 0.9..4.7 2.0 2. 2.6 /4 L 0. 0.6.0..6.9 2.2 2.6 2.9 L 0. 0.6.0..6.9 2.2 2.6 2.9 /2 L 0.4 0.7..4.8 2. 2.5 2.8.2 /2 M 0.5.0.5 2.0 2.5.0.5 4.0 4.5 /4 M 0.7. 2.0 2.7.4 4.0 4.7 5.4 6.0 M 0.7.5 2.2.0.7 4.4 5.2 5.9 6.6 /4 M 0.8.6 2.5..9 4.7 5.5 6.2 7.0 /2 M/F 0.8.6 2.5..9 4.7 5.5 6.2 7.0 /4 M.5 2.9 4.4 5.8 7. 8.7 0.2.6. Flowrate m³/hr Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 4

Thermostatic ontrol Valves - Model Valve characteristics Pressure drop (English units) Pressure drop PSI MOT thermostatic valves are designed to produce minimal pressure drop. The normal recommendation in sizing the valves is to select a pressure drop between 2 and 7 PSI (0.4 to 0.5 bar). SE 40 oil at 0 F SE 20 oil at 0 F Water Size s s s s s s s /2 L.7.4 5. 6.9 8.6 0. 2.0 /4 L.9.9 5.8 7.7 9.6.6.5 L.9.9 5.8 7.7 9.6.6.5 /2 L 2. 4. 6.4 8.6 0.7 2.9 5.0 /2 M.0 6.0 9.0 2.0 5.0 8.0 2.0 /4 M 4. 8. 2.2 6. 20.4 24.4 28.5 M 4.5 8.9.4 7.8 22. 26.7.2 /4 M 4.7 9.4 4. 8.9 2.6 28..0 /2 M/F 4.7 9.4 4. 8.9 2.6 28..0 /4 M 8.8 7.6 26.4 5. 4.9 52.7 6.5 Flowrate US gpm Flow coefficient Flow coefficients (calculated) Size Kv v /2 L.5 4.0 /4 L.9 4.5 /2 L 4. 5.0 /2 M 6. 7.0 /4 M 8.2 9.5 M 9.0 0.4 /4 M 9.5 /2 M/F 9.5 /4 M 7.7 20.5 Kv is the flow coefficient in metric units. It is defined as the flow rate in cubic meters per hour (m³/h) of water at a temperature of 6 elsius with a pressure drop across the valve of bar. The basic formula to find a valve s Kv is shown below: DP = Q Kv 2 SG Q = Kv DP SG Q = Flow in m /hr DP = Pressure drop (ar) SG = Specific gravity of fluid (Water =.0) Kv = Valve flow coefficient v is the flow coefficient in English units. It is defined as the flow rate in US Gallons per minute (gpm) of water at a temperature of 60 Fahrenheit with a pressure drop across the valve of psi. The basic formula to find a valve s v is shown below: DP = Q v 2 SG Q = v DP SG Q = Flow in US gallons DP = Pressure drop (Psi) SG = Specific gravity of fluid (Water =.0) v = Valve flow coefficient Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 5

Thermostatic ontrol Valves - Model Valve characteristics continued vailable versions ast iron ronze luminum Steel Stainless Steel Threaded Threaded Threaded Threaded Threaded /2 M/L /2 M/L /4 M/L /4 M/L /4 M/L /4 M/L /4 M/L M/L M/L M/L M/L M/L Flanged Flanged Flanged /4 M /2M/L None /2 F /2 F /4 M Flanged Welded Welded /2 M/L None /4 & M /4 & M Flanged /2F How to Order Valve Use the tables below to select the unique specification of your G valve. Example: D E F - G H - J Model /4 M U 20 0 - F - Valve Size Nominal ore Size /2 /2 inch (DN5) /4 /4 inch (DN20) inch (DN25) /4 /4 inch (DN2) /2 /2 inch (DN40) Valve Model onnections No. of s M Threaded valve M High flow valve ( /4 valve only) 2 L Low flow valve F Flanged connection ( /2 valve only) S R D F H J K M ody Material ronze (M and L) ast iron (M, M, F and L) luminum (M, /4 and only) Steel (/4 and M, /2 F only Stainless steel (/4 and M, /2 F only) Port onnection Flanged EN 092, PN0, PN6 Flanged NSI 25 lb Flanged NSI 00 lb (steel and stainless steel only Flanged 50 lb (steel and stainless steel only) Flanged NSI 600 lb ( steel and stainless steel only) Socket weld (/4 & steel & stainless steel M valves T Threaded NPT to USS 2. U Threaded SP (PL) to S 2 V W R Threaded SP (TR) Japanese (JIS) Threaded to SE J5 4H (straight thread, o-ring seal) Threaded SP (PL), boss faced, DIN 852 Form X (ronze, cast iron and ductile iron only) Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 6

Thermostatic ontrol Valves - Model How to Order Valve - continued E ontrol Temperature ontrol temp. F rack open Rated range Full open F F Max temp cont. F 065 8 65 5 59 25 77 47 6 075 2 75 20 68 29 85 60 40 085 0 85 24 75 4 9 6 45 095 5 95 0 86 40 04 7 6 00 8 0 0 9 42 08 6 4 0 4 0 8 00 47 7 82 80 20 49 20 4 0 55 86 87 0 54 0 49 20 60 40 95 20 40 60 40 54 0 65 50 95 20 50 65 50 60 40 7 60 00 22 60 7 60 65 50 76 70 00 22 70 76 7 0 72 6 82 80 00 22 75 80 75 76 70 85 85 05 22 80 82 80 79 75 88 90 0 20 90 87 90 85 85 9 200 0 20 200 9 200 90 9 4 00 22 0 20 205 96 205 9 200 0 28 0 20 25 0 25 96 205 07 225 5 29 225 07 225 0 2 4 4 27 20 248 25 25 07 225 25 24 257 G Leakhole Sizes inches (mm) /2 (0.8) /6 (.6) D /2 (2.4) F /8 (.2) G /4 (6.) H /6 (5) 0 None H* Leakhole Quantity (Number of elements w/leak hole, max. one per element 0 None (Specified on M only) (Specified on M only) 2 2 (Specified on M only) J - *Note: Leakhole quantity (this field is not used for M, L, F valves. M only). ustomer Special ode ssigned Standard products -*** ustomer special code assigned F Type and Seal Material Valve model type construction Seals 0 06 M/M/F L 25X 0765X Standard element M/M/F 25X Standard L 0765X element unan/ Nitrile Viton 99 09 02 82 M/M/F 62U Standard L 0765U M/M/F L M/M/F L M/M/F L 25P 0765P 25P 0765P 9778 0765K 86 M/M/F 44844X Nickel plated Nickel plated Nickel plated Salt water - SS Neoprene unan/ Nitrile Viton Neoprene Viton Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 7

Service kits Thermostatic ontrol Valves - Model Service Kit for Models M/L luminum, steel or stainless steel housing Replacement parts include: 5 4 O-ring seal Housing O-ring seal O-ring seal Service Kit for Models M/L ast iron or bronze housing Replacement parts include: 5 2 O-ring seal Housing O-ring seal When properly applied and installed, MOT thermostatic valves should operate for years with minimal maintenance. n inspection at two or three year intervals is adequate to detect and make provision for normal wear. The frequency of element replacement will depend on the operating conditions and the type of fluid being controlled. ecause of the diaphragm and plug construction of the wax actuated element, calibration will be maintained over thousands of cycles. Whenever elements are replaced, the O-ring seals should also be replaced. For convenience, elements and O-ring seals may be ordered together in the service kits listed here. Service Kit for Models M ast iron housing Requires two sets of parts Replacement parts include: 5 2 2 x s 2 x O-ring seals 2 x Housing O-ring seals Service Kit for Models F ast iron, steel or stainless steel housing 5 Replacement parts include: 2 5 2 O-ring seal Housing O-ring seal Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 8

Thermostatic ontrol Valves - Model Service kits continued Service kits are available with elements and seals required to service the valve. Order kits by part number and nominal temperature setting. If these are not known, refer to the model number structure that is printed on the valve nameplate and on page 7. The element part number and temperature are also stamped onto the element flange. Service kit model number structure Sample codes /2 M KIT 60 0-0 - /4 M KIT 80 06-2- Spec ode Table G - Leak hole quantity Table F - Leak hole size Table E - type and seal material Table D - temperature Table - Housing material Table - Valve type Table - Valve size Table Table Table Table D Table E Table F Table G (for M only) Valve Size Valve Type Housing Material ode Temp. ode ode no. Type Seal Material Leak Hole ode Leak Hole Size /2 M - aluminum 000* 0 Standard una N 0 None 0 /4 M - bronze 065 06 Standard Viton /2 L - cast iron 075 99 Standard Neoprene /6 2 /4 F S - steel 085 09 Plated una N D /2 /2 R - stainless steel 095 02 Plated Viton F /8 Note *Kit provides seals only. No element is included. 00 82 Plated Neoprene G /4 0 86 Salt water Viton H /6 20 0 40 50 60 70 80 90 200 25 225 25 No. of elements with leak hole Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 9

Specification Thermostatic ontrol Valves - Model Flow rate.4-2m /hr (6-54 gpm) ody materials & ast iron 0 bar (50 psi) pressure ratings ronze ` 0 bar (50 psi) luminum 24 bar (50 psi) S / SS Threaded 48 bar (700 psi) S / SS 50# Flanged 6 bar (20 psi) S / SS 00# Flanged 45 bar (655 psi) S / SS 600# Flanged 72 bar (050 psi) Seal materials Mounting position Ports Nitrile/una N, Viton, Neoprene ny orientation elow nominal temperature Ports and connected bove nominal temperature Ports and connected Port connections Threaded 5, 20, 25, 2 & 40 mm (/2, /4,, /4 & /2 ) Flanged 40 mm ( /2 ) Valve sizes 5, 20, 25, 2 & 40 mm (/2, /4,, /4 (nominal bore) & /2 ) Recommended pressure drop 0.4 to 0.5 bar (2 to 7 psi) ontrol temperatures 8 - (65 F to 25 F) Weight Weights in kg (lbs) Material /2M, L /4M, L, M, L /4M, L M, L /4MS, L MS, L /4 M /2 M, /2 L /4 M /2 FF /2 FSJ /2 FRJ /2 FSH /2 FRH ronze 2 (4) (6.6) - ast iron 2 (4) (6.6) 4. (9.5) (24) Stainless steel /2 FSK /2 FSRK.6 (8) 9 (20).5 (0) 6. (6) Steel.6 (8) 9 (20).5 (0) 6. (6) luminum.2 () Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page 0

Valve Dimensions Thermostatic ontrol Valves - Model Model M Model /4 M U U H H W F J = Inlet port = ypass port = ooler port J F PORT THREDS PLES (SEE TLE) W SQURE Dimension mm (inches) /2M, M, L, L /4M, M, L, L M, M, L, L Valve Size and Type /4M, L M, L Threaded /4MR, MS, LR, LS MR, MS, LR, LS /4 M /2 M, L /4 M H 50.8 (2) 54 (2.) 54 (2.) 7 (2.9) (4.4) J 44.5 (.78) 54 (2.) 54 (2.) 8. (.5) 9.7 (.6) F 52.4 (6.0) 60. (6.4) 60. (6.4) 58.8 (6.) 55.6 (6.2) U 90.5 (.62) 95. (.8) 95. (.8) 5.9 (4.6) 90.5 (7.6) W 79.4 (.8) 82.6 (.) 85.7 (.4) 85.7 (.4) 98.4 (.9) Model /2 F W D 40mm ( /2 ) Flange Sizing mm (inches) Flange D K NSI 25 lb 6 ( /2) 98.4 (4) NSI 50 lb 6 ( /2) 98.4 (4) NSI 00 lb 22 ( /4) 4. (4 /2) NSI 600 lb 22.2 ( 7 /8) 4. (4 /2) H Valve Size and Type (Flanged) J 4 HOLES DI D on K PD F Dimension mm (inches) /2 FF /2 FSJ /2 FRJ /2 FSH /2 FRH /2 FSK /2 FSRK H - 7 (2.9) 7 (2.9) 7 (2.9) J 50 (6) 27 (5) 56 (6.2) 56 (6.2) F 00.8 (4) 00.8 (4) 20.6 (4.8) 0 (5.) W 78 (7) 78 (7) 20.2 (8) 22 (8.75) Datasheet Thermostatic_ontrol_Valve_SEP6_Rev4 page

mericas MOT US 8824 Fallbrook Dr Houston, TX 77064 US Tel + (28) 940 800 Fax + (7) 559 949 Email general: sales@amotusa.com orders: orders@amotusa.com customer service: cs@amotusa.com Europe, Middle East and frica MOT Western Way ury St Edmunds Suffolk, IP SZ United Kingdom Tel +44 (0) 284 762222 Fax +44 (0) 284 760256 Email info@amot.com MOT ontrols GmbH Rondenbarg 25 22525 Hamburg Germany sia Pacific Tel +49 (0) 40 857 298 Fax +49 (0) 40 857 Email germany@amot.com MOT Shanghai d. 7, No. 568, Longpan Rd., Malu Jiading Shanghai 2080 hina Tel +86 (0) 2 590 4052 Fax +86 (0) 2 527 8560 Email shanghai@amot.com Follow us on Twitter: @MOT_Global www.amot.com