Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Similar documents
Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Installation Instructions Model SSD-C-REM

Fire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

AND ARCHITECT SPECIFICATIONS

MXL/MXLV 19 Rack Mount Equipment

MXL/MXLV Enclosuress & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4

Fire Safety. Installation Instructions Model PSR-1 Remote Power Supply INTRODUCTION. Figure 1 PSR-1 Remote Power Supply

Operating Instructions MXL Multi-Line Keyboard/Display Panel

Advanced Protection System

Installation Instructions Model HZM

Installation Instructions Model DLC

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Fire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

Installation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator

ANNUNCIATOR FIXED MODULE

MMF Six Zone Interface Module

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Installation Instructions Model CDC-4

IDP-Zone-6 Six Zone Interface Module

Booster Power Supply Manual

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

SC-6 Six Supervised Control Module

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

'08 Series Notification A liances

Addressable NAC Output Module D327A

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

Air Duct Housings. Description

* These Remote Mics must be SPRM-GP

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

30.45 Electric Release PDRP-2001

General Routing Interface

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

4100U City and Relay Cards Installation Instructions

TruPortal Wireless Locks Quick Reference

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

CZ-6A Six Zone Interface Module

Public Safety DAS Annunciator Panel

Multiplex Eight Input Remote Modules

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

These instructions detail procedures to follow in order to avoid damage to equipment.

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

FireNET Plus Wiring Instructions

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Installation Instructions Model ABHW-4S

Marine Fire Detection System Manual MXL Control Panel

RMS/RPX Reader. User Manual

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Desigo TM Fire Safety System A comprehensive fire-protection system

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Multiple Input and Output Modules

MOUNTING DETAILS. Mounting Matrix / Details ENGINEER AND ARCHITECT SPECIFICATIONS CATALOG SHEET. 2-1/8 Deep

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

s Notification Appliances

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

Remote NAC Power Supply D7038

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

HARDwired Installation/ Owner s Manual

The ACM-8R Annunciator Control Module

Fire Safety. Installation Instructions Model CSM-4 Controllable Signal Module OPERATION INSTALLATION

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

MGD-32 and AGD-048. Remote Multiplex Graphic Driver Annunciators and Adder Boards. Wiring and Installation Manual

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

June 10, 2002 DF C S2424

20 Light Remote Annunciator

MANUAL RESET ALARM RELEASE

Lamp Driver Module LDM-32F

Cerberus PRO A comprehensive fire-protection system

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

Installation Instructions Model CAB-BATT/R

I NSTALLATION M ANUAL

SIGA-CC1 Single Input Signal Module Installation Sheet

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

E340 BOILER CONTROL INSTALLATION MANUAL

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

MPC-6000 / MPC-7000 / RND-2

Installation Guide for models:

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

FireNET Fire Alarm Control Panel Installation Manual

AND ARCHITECT SPECIFICATIONS

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

PSN-1000 & PSN 1000(E) Installation Manual

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations

Operation and Installation Guide. Zone Expansion Module D8125

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

PFC-4064 Conventional Fire Alarm Panel

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

PN: 53049:A1 ECN Agent Release Control System MRP-2002 MRP-2002E. Document # /01/08 Revision: A1

Desigo TM Fire Safety System A comprehensive fire-protection system

Transcription:

Fire Safety Installation Instructions Model RCC-/R and RSE- Remote Control Centers INTRODUCTI The SIEMENS Model RCC-/R Remote Command Center (See Figure ) provides the option to remotely annunciate and control MXL and MXL-IQ system status. The RCC-/R and RSE- provide for mounting and control of the PIM- printer interface module. The following modules come already installed in an RCC-/R: Keypad LCD Display ANN- Driver Board PS-5N7 Power Supply The following modules come already installed in an RSE-: ANN- Driver Board PS-5N7 Power Supply The RCC-/R has a mounting location for an optional PIM-. The RSE- has the same mounting and requires the PIM-. The RCC-/R comes with a clear lens on a secure door. This limits access to the control of the system or the display. The door is secured with a T-5 lock set. OPERATI The keypad on the RCC-/R operates the same as the MKB in the MXL enclosure. See Section of the MXL Installation, Operation and Maintenance Manual, P/N 5-0906, for the complete operating instructions for the control panel. INSTALLATI Always remove all power before installation, first the battery and then the AC. Setting the Network Address Before installing the RCC/RSE, set the network address on S-SW and S-SW of the ANN- board. Refer to Table for switch settings. (See also Setting the Network Address in Section, INSTALLATI of the MXL/MXLV Manual, P/N 5-0906.) SWITCH S-SW TABLE SWITCH SETTINGS THE ANN- ADDRESS SETTINGS FOR: 8 9 50 5 On S-SW S-SW S-SW S-SW5 Figure RCC-/R Remote Command Center Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 079 NOTE: Switches S-SW and S-SW are for future use. Switch S-SW5 is used to select supervision. Siemens Building Technologies, Ltd. Kenview Boulevard Brampton, Ontario L6T 5E CN P/N 5-09960-6

Setting Supervision Use switch S-SW5 on the ANN- to select or deselect supervision. If your ANN- has a switch with position indicated on the left-hand side, ignore the printing on the switch. SW on S is at the extreme right-hand side of S, regardless of any other marking. To set for supervision S-SW5 = Closed () To set for non-supervision S-SW5 = Open () NOTE: When you select non-supervision for an annunciator, there must also be one and only one supervised annunciator at the same address. Mounting Before mounting the RCC/RSE, follow these steps:. Remove the cover assembly from the backbox.. Disconnect at P the cable from the PS-5N7.. Remove the PS-5N7 from the backbox (See Figures and ).. Set the panel to one side. Consider the following when mounting the backbox: Mounting height for visual and manual access to the keypad Weight and size of the enclosure Local mounting codes To mount the RCC/RSE, follow these steps:. Fasten the RCC/RSE backbox securely to a clean, dry, shock-free, and vibration-free surface using the four mounting holes provided. (Refer to Figure for the dimensions of the backbox and the location of the mounting holes.) Position the RCC/ RSE backbox clear of obstructions so that the door opens freely and the indicators and controls are easily accessible.. Pull all field wiring into the backbox and dress the wiring to the approximate location to which it will go. Install field wiring to the PS-5N7 (Refer to PS-5N7 Installation Instructions, P/N 5-0979).. If a PIM- is required, mount it to the set of four standoffs to the right of the PS-5N7 (See Figures and ). Connect P on the PIM- to P on the ANN-, using the inch cable, P/N 555-9. Connect P on the PIM- to P on the PS-5N7, using the inch cable, P/N 555-9 (Refer to PS-5N7 Installation Instructions, P/N 5-0979, PIM- Installation Instructions, P/N 5-096 and Figure 6).. If a PIM- is not installed, reconnect P on the ANN- to P on the PS-5N7. 5. Reattach the cover assembly to the backbox. 6. Refer to the MXL/MXLV Manual, P/N 5-0906, for additional information on the operation of the keypad. ELECTRICAL RATINGS RCC/RSE: 8- VDC, 80mA max Battery current: 75mA RCC/RSE with PIM-: 8- VDC, 00mA max Battery current: 95mA WIRING Refer to the following Installation Instructions as needed: MMB- P/N 5-09075 MMB- P/N 5-095097 PSR- P/N 5-0909 PS-5 P/N 5-08506 PLM-5 P/N 5-0995 PAD- P/N 5-09908 SMB- P/N 5-0959 MXL/MXLV Manual P/N 5-0906

PS-5N7 COVER LCD DISPLAY ANN- RCC-/RSE- BACKBOX PIM- (OPTIAL) ANNUNCIATOR PANEL RCC-/RSE- OUTER DOOR Figure RCC-/R Exploded View PS-5N7 ANN- RSE- BACKBOX PIM- (REQUIRED) RSE- OUTER DOOR Figure RSE- Exploded View

NOTE: The RCC/RSE MUST have an earth ground connected to the chassis. Wire shield or conduit is not an acceptable ground. Use any available unused, unpainted stud for chassis grounding. Figure RCC-/R, RSE- Dimensions PSR- TB DO NOT USE DO NOT USE NO EOLR 6 5 TB CHASSIS EOLR 0 OHMS /W, 5% P/N 0-8050 PS-5N7 (INSTALLED IN AN RCC-/RSE- ENCLOSURE) PSR- TB SHIELD MMB- / SMB- NO EOLR EOLR 0 OHMS /W, 5% P/N 0-8050 Notes:. Use a minimum wire gauge of 8 AWG.. Use a maximum of 80 ohms per pair of wires for the network connections.. Use shielded twisted pair for network connections.. Terminate the shield LY at the MMB/SMB enclosure. 5. PSR- only allowed in systems with MMB-. 6. DO NOT place the PS-5N7 at the end of the network (Style 7 only). 7. This configuration is power limited to NFPA 70 according to NEC 760. 8. All wiring supervised. 9. Refer to Wiring Specification for MXL, MXL-IQ and MXLV Systems, P/N 5-0977 revision 6 or higher, for additional wiring information. Figure 5 PS-5N7 Power Supply and Network Wiring Diagram in RCC/RSE Enclosure (Style )

CABLE P/N 600-90505 P POWER TO MOM- TB MMB- / SMB- 5 N PSR- P7 FOR NET-7 N ET 7 M E T W O R K TB SHIELD SHIELD CHASSIS P6 TB P6 5 6 7 8 9 0 5 6 TB P5 TB6 P7 CABLE P/N 555-90967 EOLR 0 OHM, /W, 5% P/N 0-8050 P NET-7 MOM- MAKE THIS CNECTI TO ANY OF THE FOLLOWING TERMINATIS: MMB SMB PSR- PLM-5 (Used with PS-5) ALARMSAF (Model AS/PS5-BFS--UL) PAD- TB5, 9- TB5, 9- TB, -6 TB, - TB, and TB, Aux P.S. + VDC - VDC RETURN SUPERVISED POWER LIMITED NETWORK A (PRIMARY) SUPERVISED POWER LIMITED NETWORK B (SECDARY) SUPERVISED POWER LIMITED 5 6 TB PS-5N7 (INSTALLED IN AN RCC-/RSE- ENCLOSURE) RCC- / RSE- Notes:. Use a minimum wire gauge of 8 AWG.. Use a maximum of 80 ohms per pair of wires for the network connections.. Use shielded twisted pair for network connections.. Terminate the shield LY at the MMB/SMB enclosure. 5. PSR- only allowed in systems with MMB-. 6. DO NOT place the PS-5N7 at the end of the network (Style 7 only). 7. This configuration is power limited to NFPA 70 according to NEC 760. 8. Refer to Wiring Specification for MXL, MXL-IQ and MXLV Systems, P/N 5-0977 revision 6 or higher, for additional wiring information. Figure 6 PS-5N7 Power Supply and Network Wiring Diagram in RCC/RSE Enclosure (Style 7) 5

Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 079 Siemens Building Technologies, Ltd. Kenview Boulevard Brampton, Ontario L6T 5E CN P/N 5-09960-6