Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design)

Similar documents
Conductivity Electrode LRG Original Installation Instructions English

GESTRA. Product Overview. The optimum components for every application

TDS Conductivity Probe In-Line conductivity measurement

Product overview. the optimum components for every application

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

GESTRA. Product Overview. The optimum components for every application

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

Electronic steam boiler controls

Alpha Engineering Company

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Concise catalogue Water-Industry

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG Original Installation Instructions English

Analytical Testing for Growers. Test crucial parameters in hydroponics and greenhouse applications. hannainst.com/groline

Condensate Monitoring OM0232

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Figure 1 DirectLine DL423 Sensor. Description, continued

Intermittent blowdown valve MPA / PA up to PN250

Installation & Operating Instructions

Figure 1 DirectLine DL423 Sensor. Description, continued

Temperature Sensor TRG Original Installation Instructions English

SECTION Boiler Controls & Waste Heat Recovery

MAIN MENU/HOME SCREEN OVERVIEW

Mobrey electronic probes

MEAS CAL ALARM WASH CONF APT4000 TC

NRG NRG NRG NRG

Green Energy Engineering, Inc.

Signet V(D) to V(D) PVDF Conductivity Electrodes

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

LC2200 Level Controller Installation and Maintenance Instructions

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

CATALOGUE.PDF BLUELAB DOSETRONIC ATC PH PROBE. Code Product Unit RRP

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Toroidal Conductivity Transmitters Series APT4000 Specifications

SECTION Free/Available Chlorine Analysis System

Hydrazine Analyzer Series 2171 Specifications

CATALOGUE.PDF EUTECH PH TESTER W/PROOF ATC 3P CAL. Code Product Unit RRP

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Personal ph, ph/orp, Conductivity Meters

ph COOLING TOWER CONTROLLER

Instruments. for hydroponics & horticulture 2016

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

Quality Endorsed Company ISO 9001 Lic. No. 5403

Personal ph, ph/orp, Conductivity Meters

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

ENDURANCE Conductivity Sensors

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Condensate Recovery and Return System SDR A

Inductive Conductivity

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Aparajit Instruments.

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

LC3000 Level Controller Installation and Maintenance Instructions

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

MULTIPLEX SELF RECUPERATIVE gas burner

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

LC2610 Level Controller Installation and Maintenance Instructions

icountms Range Fluid Condition Monitoring Moisture Sensors

BC3250. Blowdown Controller

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Retractable ph/orp Sensor

Thermostats. Innovative solutions for the toughest requirements

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Using the Model 1500 Portable Chilled Mirror Hygrometer

Steam and Water Analysers

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Excellence through Versatility

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50

Enraf Servo Gauge 854 ATG

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Model Q45P/R. ph/orp Monitor...

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Yarway Narvik Steam Desuperheater Series 4300 TempLow

BOILER HOUSE PRODUCTS GMS

Durafet Non-Glass ph Electrodes Specifications

HIGH CAPACITY PRODUCT LINE

Our. Heaters. for your Projects

PRODUCT CONFORMITY CERTIFICATE

Alfa Laval Potentiometric Level Transmitter

Thermostats. Innovative solutions for the toughest requirements

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel

The A-series Eletta Flow Monitor with local indication and analog output

Relative Humidity Transmitters

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

Transcription:

Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design) Manual Temp. Compensation LRG 16-4 / LRG 12-2 Purpose and Application The conductivity electrodes LRG 16-4 and LRG 12-2 are used in conjunction with conductivity switch LRS 1-5/6 b or conductivity controller LRR 1-5/6 b to sense continuously the conductivity of process or boiler water. LRG 17, LRG 19 I Conductivity monitoring In combination with GESTRA conductivity switch LRS for continuous TDS monitoring of boiler water. Particularly suitable for steam boiler operation without constant supervision (TRD 604). II Continuous blowdown control In combination with GESTRA blowdown controller LRR 1-5 and blowdown valve.reaktomat for fully automatic.continuous and intermittent blowdown control. Accurate TDS control reduces water.consumption and increases the operational safety of the installation. An alarm is raised when the desired boiler water condition cannot be obtained by the control system..automatic isolation of blowdown line during boiler shut-down. LRR 1-5 b/lrr 1-6 b Purpose and Application For automatically controlled blowdown to reduce blowdown wastage and increase safety in operation. Use in conjunction with GESTRA conductivity electrode LRG 16-4 or LRG 17/19 as sensing unit, and GESTRA continuous blowdown valve as control valve. Automatic closing of blowdown line during boiler shut-down. Current output for remote indication or recording of conductivity. Application in steam boilers, evaporators or similar plant, in particular plants operated automatically, e. g. in accordance with the regulations for operation without constant supervision (TRD 604). Design Plug-in unit in plastic case for installation in control cabinets. The terminals in the case are accessible after undoing two screws and unplugging the unit from its base. To avoid confusion with other plug-in units of the GESTRA range, inserts are fitted in the bases so that only the correct unit may be plugged into each base. The plug-in units may be snapped onto a 35 mm supporting rail or screwed into position on a mounting panel. Field enclosures for several plug-in units are available on request.

B Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design) Automatic Continuous Blowdown Control Manual Temp. Compensation < 275 C Equipment PN LRG 16-4 G 3 /8" BSP 40 3772245 LRR 1-5b 3801441 LRG 1x LRR 1-5 URS 2 4-20 ma MAX MIN 46-3 DN 15 3891203 46-3 DN 20 3891403 46-3 DN 25 3891503 LRG 17-1 60 bar 275 C 63 3771443 LRR 1-5 3801441 210 47 25/63 3901500 GAV LRG 19-1 60 bar 275 C 160 3771743 LRR 1-5 3801441 LRG 17-1 LRG 19-1 0525 210 SE 33.7 x 3.6 250 3931500 DN 25 Fl. 393150001 GAV see pages 71. Flanges see Price List. Tee piece connector for LRG 16-4 see Price List. Level pots LRG 17-1/19-1 see page 117. (optional)

Conductivity Monitoring with Manual or Automatic Temperature Compensation LRG... / LRR 1-5/6 Manual Temp. Compensation LRS 1-5 b, LRS 1-6 b Continuous monitoring of the conductivity of liquids with GESTRA conductivity electrodes LRG 16-4, LRG 17 or LRG 19. Signalling of preset conductivity limits. Application in steam boiler plants for condensate and feedwater monitoring; for condensate monitoring in district heating plants, in the paper and pulp industry and in catering.kitchens; for conductivity monitoring in water.treatment plants; for monitoring of cooling towers, for dyebath monitoring in dye works. Automatic Temp. Compensation LRG 12-1 Purpose and Application. In conjunction with GESTRA conductivity transmitter LRT 1 for continuous monitoring of the conductivity of liquids, signalling of limit values, remote indication or recording. Application in steam boiler plants for feedwater and condensate monitoring, as well as in district heating plants, paper and pulp.industries, catering kitchens, for dyebath monitoring in dye works, and for conductivity monitoring in water treatment plants. Design. The conductivity electrode is provided with two electrode tips completely insulated by a PTFE tubing except for the free ends. The non-insulated ends form together with a PTFE sleeve a measuring cell. The screwed body incorporates a temperature feeler.. A system of compression springs ensures pressure-tight sealing between electrode tips and body even at varying temperatures. URS 2-b Purpose and Application Universal signalling of two limit values as MAX and MIN alarm. Connection to a measuring transducer with current output 0/4 20 ma. Application for instance with GESTRA level transmitter NRT 2-1b, continuous blowdown controller LRR 1-5 b and conductivity transmitter LRT 1-5b/LRT 1-6b. Design. Plug-in unit in plastic case for installation in control cabinets. The terminals in the case are accessible after undoing two screws and unplugging the unit from its base. To avoid confusion with other plug-in units of the GESTRA range, inserts are fitted in the bases so that only the correct unit may be plugged into each base. The plug-in units may be snapped onto a 35 mm supporting rail or screwed into position on a mounting panel. Field enclosures for several plug-in units are available on request. LRT 1-5 b, LRT 1-6 b Measuring transducer with analogue current output used in conjunction with conductivity electrode LRG 12-1 for continuous monitoring of liquids, signalling of limits, remote indication or recording. Application mainly in condensate systems to detect any ingress of foreign matter, e. g. in steam boiler plants for monitoring the boiler water or the condensate returned to the.boiler.

B Conductivity Monitoring with Manual Temperature Compensation LRG... / LRR 1-5/6 Manual temperature compensation Temperature > 275 C 210 Sample valve unit > 275 LRG 12-2 3773030 PK-250 PE2A GAV LRR 1-5 URS 2 MAX LRR 1-5 3801441 210 DN 25 Fl. 393150001 MIN GAV see page 71 PK Sample valve unit followed by conductivity electrode LRG 12-2 LRG 12-2 PK Signalling of MAX and MIN conductivity values automatic temperature compensation LRT 1-.. Conductivity transmitter URS 2 MIN-Alarm MAX-Alarm Automatic temperature compensation Equipment PN LRG 12-1 10 3771040 LRT 1-5 < 10000 µs/cm 3811441 LRT 1-6 < 100 µs/cm 3811541 Signalling of MAX. conductivity value Manual temperature compensation Equipment PN LRG 16-4 40 3772244 LRG 17-1 63 3771443 Conductivity electrode LRG 12-1 Remote level indicator URA 2 Three-way control valve LRG 19-1 160 3771743 LRS 1-5 < 10000 µs/cm 3781441 LRS 1-6 < 100 µs/cm 3781541

Ancillaries: Level Pots and Portable Measuring Instruments VRM VRM 2 The service case VRM 2 contains the conductivity meter GMH 3410. The GMH 3410 is equipped with a built-in measuring cell which.measures the conductivity of water. Function The GMH 3410 is suitable for conductivities within a range from 0 to 200 ms/cm. Design VRM 2 Plastic case with foamed plastics insert. Conductivity measuring instrument GMH 3410 with built-in measuring cell. VRM 3 The service case VRM 3 contains the conductivity meter GMH 3410 and the ph measuring device GMH 3510. The GMH 3410 is equipped with a built-in measuring cell which measures the conductivity of water. The GMH 3510 is equipped with ph electrode type GE 100 BNC and Pt 100 temperature probe type GTF 401. The electrode and the probe are plugged into the equipment. The service case contains also the handling and calibration set GAK 100, consisting of: 5 orange capsules for the calibration.solution ph 4.01 and a plastic bottle 5 green capsules for the calibration. solution ph 7.01 and a plastic bottle 5 blue capsules for the calibration. solution ph 10.01 and a plastic bottle 1 bottle 3mol KCL-solution 1 bottle pepsin cleaning agent Function The GMH is suitable for conductivities within a range from 0 to 200 ms/cm. The GMH 3510 together with the ph electrode GE 100 BNC can measure ph values from 0.00 to 14.00. The temperature probe measures temperatures between 50 C and +250 C. For ph measuring the temperature range is limited to 10 C to 50 C. Design VRM 3 Plastic case with foamed plastics insert. Conductivity measuring instrument GMH 3410 with built-in measuring cell. ph meas. device GMH 3510 with ph electrode GE 100 BNC and temperature probe GTF 401. Calibration set GAK 1400.

B Ancillaries: Tee Pieces, Level Pots and Portable Measuring Instruments VRM Tee Pieces for Conductivity Electrodes Connections DN 2 ) DN 50 mm 1 ) 3 /8" 1 ) To suit electrode LRG 16-4 Material: C 22.8 / St 35.8 To suit conductivity electrodes LRGT 16-1 / LRG 16-40 Material: C 22.8 / St 35.8 15 141873 20 141874 25 141875 40 1) 141876 15 147093 20 147094 25 147095 40 147096 Level Pots Instruments for Conductivity Electrodes DN 15-40 mm. DN 15-40 mm. DN 25 mm.connection DN 25 mm 3 ) MF 1161 STT For installing level electrodes outside the boiler LRGT 16-1 / LRG 16-40 Material: C 22.8 / St 35.8 / 88.9 MF 1162 STT For installing level electrodes outside the boiler LRGT 16-2 / LRG 16-41 Material: C 22.8 / St 35.8 / 139.7 MF 1171 STT To suit electrode type LRGT 17-1, LRG 17-40. Material: C 22.8 / St 35.8 / 88.9. Pressure rating: PN 63 Connections DN 2 ) 15 1500632 20 1500633 25 1500634 40 1 ) 1500635 15 20 25 40 25 1500989 DN 25 mm.connection DN 25 mm DN 50 mm Electrode. connection 3 ) 3MF 88.9 To suit electrode type LRG 17-1/LRG 19-1 For continuous blowdown valve (automatic continuous blowdown control) PN 63 25 PN 160 25 1500987 1500988 1 ) Approval acc. to PED 97/23/EC Module A1 60, 2 ) Please state nominal size (DN) when ordering. 3 ) Approved in acc. with PED 97/23/EC 299, Portable Measuring Instruments for Conductivity + ph Value Type VRM 2 Conductivity 3821040 VRM 3 Conductivity, temperature and ph value 3821141