Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Similar documents
OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Transmitters/Sensors. OLCT Series

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

3M Oldham OLCT 100. Description. Fixed Gas Detector

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Detection, Protection, Innovation

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Sieger Apex. Flexibility that meets your requirements

GAS DETECTOR ST400EC PART.NO

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

incontrol Systems Inc. Flame and Gas Detection

3M Oldham MX 43 Controller

Danfoss gas detection unit Type GD Heavy Duty

Global Gas Detection and Monitoring Solutions

SenSmart Universal Gas Detector Series

ALTAIR 5X Multigas Detector Product Specification

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Industrial Grade Gas Detection Detecting The Difference

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Dräger Polytron 8000 Stationary gas detector (EC)

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Dräger Polytron 7000 Fixed gas detector

User manual CTX 300. Analogic Gas Detector. The Fixed Gas Detection Experts. Part Number: NP300GB Revision: K.1

Model D12. Digital Gas Transmitter

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

User manual CTX 300 Analogic Gas Detector

MODEL 9010/9020 LCD CONTROL UNIT

Two-Channel Gas Controller

Danfoss gas detection units

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Products and performance

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Danfoss gas detection units

Stand Alone DYNAGARD SP Operation Manual

Zareba Sensepoint Pro

Dräger Polytron 5100 EC Detection of toxic gases and vapors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Industrial Grade Gas Detection

S5000 Gas Monitor. GMS5000.com

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger Polytron 5720 IR Toxic Gas Detection

SUPREMATouch Modular Fire & Gas Detection System

Toxic Gas Detection. Model F12. Toxic Gas Detection

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Recalibrate the way you look at gas detection

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger REGARD -1 Control System

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

APPLICATION DATA SHEET

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

XNX Universal Transmitter

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Warranty Registration

Dräger PointGard 2100 Detection of toxic gases and vapours

Installation and Operating Manual MX 32 2 CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Reference: NPM32GB Revision: B.1

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Dräger Polytron 8000 Stationary gas detector (EC)

YOUR PARTNER IN FIRE & GAS DETECTION

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ULTIMA X5000. MSAX5000.com

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Touchpoint Pro Flexible Gas Control System

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

Dräger Polytron 5720 IR Detection of carbon dioxide

Dependable Solutions for Gas Detection

APPLICATION DATA SHEET

Transcription:

Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI Integrated relays Direct link, 4-20 ma, loop and isolated sensor mode Certifications The Fixed Gas Detection People www.oldhamgas.com an company

Configuration Options Alarms 1 & 2 4-20 ma Power Supply 1 Power Supply 2 4-20 ma input RS 1 RS 2 Alternate input Sensor Standard Version Stand Alone Version Controller Power Supply 3 optional relays (fault, Al 1, Al 2) 3 optional relays (fault, Al 1, Al 2) 2 4-20 ma input Sensor Sensor Digital Version Centrale Relays ( Fault, Al1 an dal2) 2 4-20 ma input www.oldhamgas.com

Specifications Type Transmitter-sensor Detected gases Detection principles Sensor block Housing Sensor Enclosure Visualisation Power supply to sensor terminals Maximum power with digital link with I output at 25 ma with I output at 25 ma and relays activated Inputs Signal outputs Logic (relay contacts): Relay Analog: Digital: Signal faults: Alarms Explosive, toxic and oxygen Catalytic, Electrochemical, IR, Semiconductor Pre-calibrated Stainless steel 316L Aluminium 4-digit LCD display for measurement and one alphanumeric line for texts, Pictograms - backlighting 4 indicator lamps : one green : "Operation OK", one yellow : "Fault", red : "Alarm 1" and "Alarm 2" Two independent inputs : 16 to 28 VDC (catalytic / IR / SM cells) 12 to 28 VDC ( cell) 0.2 W ( cell) - 1.3 W ( catalytic / SM ) - 4.5 W (IR) 0.9 W ( cell) - 2 W ( catalytic / SM ) - 5.2 W (IR) 2.4 W ( cell) - 3.5 W ( catalytic / SM ) - 6.7 W (IR) Two analog inputs 4-20 ma (load resistance 120 Ω, can be used as binary) Standardised 4-20 ma output Two independent opto-isolated RS 485 ports I < 0.5 ma 2 programmable thresholds per channel Relays Type SPDT Number 3 Contact RCT changer-over Breaking capacity 2A / 250 VAC / 30 VDC Wiring / connection: Load resistance on the 4-20 ma Basic version, 6 inputs : 4 M20 and 2 M25 On request : 3 additional, 2 M20 and 1 M25 500 Ω Under central unit 21 VDC: 128 ohms ( Loop resistance cell ) - 32 Ω ( catalytic / SM ) - 16 Ω (IR) Fastening system See drawings Protection number IP 66 Operating temperatures Dimensions - 25 C to +55 C ( electronics, see table for detection cells ) See drawings Weight OLCT 80 : 3,5 kg OLCT80 version IR : 5,3 kg OLCT 80 d OLCT 80 id (with intrinsic safety sensor block) II 2GD II 2GD Certification Atex Electromagnetic compatibility EEx d IIC T5 (T C) or T6 (T85 C) INERIS 03ATEX0240X Complies with EN 50270 EEx d [ia] ia IIC T4 (T135 C) INERIS 03ATEX0240X

SPECIFICATIONS Type of Gases Type of sensor Range (ppm) Operatingttemperature* ( C) Relative humidity uncondensed Pressure Accuracy at full scale (at atmospheric pressure) Life span (in months) T (50) IP IS AD O 2 30,00% -20 C to +50 C from 5 to 30% = 0,4%vol 28 6 66 YES YES CO 300 0-20 C to +50 C +/- 2 ppm (range 0-) 40 10 66 YES YES H 2S S 30 0 +/- 1,5 ppm (between 0-30 ppm) 36 15 66 YES YES NO 300 0-20 C to +50 C +/- 2 ppm (range 0-) 36 15 66 YES YES NO 2 10-20 C to +50 C +/- 0,8 ppm 24 20 66 YES NO 10.0-10 C to +50 C +/- 0,7 ppm range 0-10 36 15 66 YES NO Cl 2 10.0-20 C to +50 C +/- 0,5 ppm 24 50 66 YES NO H 2 2000-20 C to +50 C +/-5 ppm range 0-24 50 66 YES YES HCl -20 C to +40 C +/- 0,5 ppm range 0-10 24 50 66 YES NO HCN 1.0-20 C to +40 C +/- 0,3 ppm range 0-10 18 40 66 YES NO NH 3 0-20 C to +40 C -20 C to +40 C +/- 5 ppm +/- 10 ppm range 0-0 24 50 66 YES YES O 3 1,00-10 C to +40 C +/-0,05 ppm 20 50 66 YES NO PH 3 1,00-20 C to +40 C +/- 0,05 ppm 18 40 66 YES NO ClO 2 3,00-20 C to +50 C +/- 0,3 ppm 24 50 66 YES NO SiH 4 50-20 C to +40 C +/- 1 ppm 18 40 66 YES NO AsH 3 1,00-10 C to +40 C 20% to 95% RH +/- 0,05 ppm 18 40 66 YES NO CH 4 catharometre 0-%vol -20 C to +50 C 1% vol 60 5 66 H 2 catharometre 0-%vol -20 C to +50 C 1% vol 60 5 66 YES YES NH 3 catalytic 0-5000 -20 C to +50 C ppm 36 8 66 YES YES Flammable gas catalytic 0-% LIE -20 C to +70 C -20 C to 200 C 1% lie between 0-60%LIE 1% lie between 0-60%LIE 60 60 5 5 66 66 VOC semi-conductor 500 ppm -20 C to +50 C +/- 4 ppm if measure < 200 ppm 36 25 66 NO YES CO/H 2 null 0 ppm -20 C to +50 C +/- 4 ppm if measure < 200 ppm 36 25 66 YES YES CO sensor +/-20 ppm if measure>200 ppm YES YES * Temperature at 20 C and at Atmospheric Pressure

Configuration Options Unique advantages providing the solution you need Design advantages Pre-calibrated sensors for detection of: combustible gases: LEL catalytic and IR toxic gases oxygen Series 80 detectors are compatible with all Industrial Scientific sensors. Series 20, Smart Sensors are precalibrated. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Inputs Series 80 sensors have up to 9 glands dedicated to cable wiring Design advantages: The minimum configuration includes: 1 electrical input dedicated to a sensor. two 4-20 ma or binary inputs. This configuration allows any other sensor from the network to be recognized (e.g temperature sensor, emergency stop, flame detector, smoke detector). Outputs 4/20 ma with smart signal processing analog signal 4-20 ma data signals between 0 and 4-20 and 25mA The transmitted signal, between 0 and 3.2 ma and above 20 ma, can be processed to interpret and identify a wide range of trouble parameters such as: line faults, sensor faults, emb edded electronics faults, ambiguity resolution, inhibition of calibration, maintenance call (initial drift or drift over time). RS485 (1200 bauds, 38kb Modbus ASCII for MX 62). The RS485 link gives access to : - sensor measurement - status and default - internal relay management Relays The relays are 2A / 250 VAC type with potential free SPDT contacts. Two types of relays: 2 gas alarm relays or supplementary inputs 1 fault relay The relays are actuated either directly by the sensor electronics or supplementary inputs, or from the MX62 central unit or the control system to which the sensor is connected. The relays can be in safety mode or not, triggered on increasing or decreasing alarms, manually* or automatically acknowledged. * By remote control, by pressing an external pushbutton connected to the dedicated binary input, by acknowledging on the MX 62 unit or the control system to which the sensor is connected. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Technical advantages Stand-alone central unit For relay control, the OLCT 80 can operate as a standaloneunit: an indisputable advantage in a classified explosion risk zone. Flexibility of connection modes OLCT 80 sensors can be connected either: in loop (opto-isolated - up to 16 sensors), 4-20 ma, under direct power and operate as a central unit. Operation traceability The operator can check records locally for the most recent time-date stamped events. Communication Remote dialogue with the sensor using IR remote control. Measurement power supply redundancy Independent ports allow a redundant connection to the measurement unit. Low power requirements The leading edge technology used in the OLCT80 transmitter makes it very energy efficient. This major advantage means that more sensors can be connected, with smaller wire cross-sections and over greater distances. Logistic advantages Loop arrangement The transmitter is perfectly adapted to mounting and connection to the digital fieldbus loop of the MX 62 unit. Supporting 1 to 3 digital addresses: the sensor block (detection element), the two 4-20 ma auxiliary inputs.

Certification The OLCT80 Series is certified to the specifications required by standards EN 50054, 45544 and 50104 (environmental standards, explosive and toxic gases and oxygen) and to the specifications of standards EN 50270, EN 60529 (electromagnetic compatibility, ingress protection). OLCT 80 uses digital logic and software technologies. The sensors are protected and in compliance with the specifications of standard EN 51271: analog and digital values track each other homogeneity of digital resolution and response time with the specifications required internal self-diagnostics ACCESSOIRES A Infrared remote control B Tool kit C Bypass adapter D Cover key E Calibraion cup F Splash guard G Remote gas introduction device H Gas collector OLC(T)80_Lit_EN_17Oct2013 www.oldhamgas.com AMERICAS Tel.: +1-713-559-9280 Fax: +1-281-292-2860 americas@oldhamgas.com EUROPE Tel.: +33-3-21-60-80-80 Fax: +33-3-21-60-80-00 info@oldhamgas.com ASIA PACIFIC Tel.: +86 21 5899 3279 Fax: +86 21 5899 3280 info@oldhamgas.com