M12 Class 2 Laser Emitter

Similar documents
M12 Class 1 Laser Emitter

MINI-BEAM Expert Series

R-GAGE QT50R-AFS Sensor

R-GAGE QT50R-AF2W Sensor

Indication & Pick-to-Light Solutions

Eurys Series. User Guide. Broadband Faraday Rotators & Optical Isolators Small Aperture (5mm)

OWNERS MANUAL OPERATION GUIDE

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

CATALOGUE LASER POINTERS

Retroreflective sensor with polarization filter

R-GAGE QT50R-AF2 Sensor

3 963/963E Benchtop Air Ionizer Instructions

Class 1 laser beam sensor safe for your eyes

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Ultrasonic Reflective Sensor

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

TrueClean ToteCleaner

USER S GUIDE. Please ONLY use manufacture provided transformer

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

TrueClean ToteCleaner

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

onlinecomponents.com

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Quadrature Speed and Direction Sensors

Design Criteria. Installation

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

CD6102 / CD6102 OC / CD6102-2

100 Ft. LASER DISTANCE METER

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

XT Series Thermostats

9780 SW Freeman Dr. Wilsonville, OR USA Tel: Fax: crimsontrace.com Rev002 12/15

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Installation Instructions for the

Duct Mount. Installation Instructions

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

CO2 Sensor User and Installation Guide

Cemar Electro Inc. MAXX-606/607 Patient Positioning Laser. Installation and Set-up Manual

NLC C61 Air-Cooled Argon-ion Laser

PM-200 Power Module Operating Instructions

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

The Series LFII (TY3596) Residential

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

R-GAGE QT50R-AF2W Sensor

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

USER MANUAL SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS

Ultrasonic Reflective Sensor

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Optical laser distance sensors. Dimensioned drawing

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

UNIVERSAL COMPACT SENSORS

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

No Touch Door Release Exit Sensor ACA-NTEB

Model 400 Series Lights Installation Instructions

Corrosion Resistant Fluid and Air Handling Systems.

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Solar Powered Wireless Photobeam Sensors

MaxLite LED MICRO-T PANEL

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Original instructions Sense7-series Non-contact coded safety switch

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

MaxLite LED Vapor Tight Linear Fixture

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

SolarPRO CURVE HEATER OWNER S MANUAL

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

3M Benchtop Air Ionizer 963E. User s Guide

OPERATION MANUAL MODEL & ACCELEROMETER

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

NLC 210 Air-Cooled Argon-ion Laser

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Instruction Manual. Self-Leveling Laser Level Model No

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Neon LED Rope Light Installation Instructions

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Sound Cover [ , , , ]

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

OKB, OKD, & OKH Series

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Transcription:

Datasheet IEC Class 2 Laser for Use with Banner Modulated Receivers Uses a self-contained Class 2 modulated laser emitters with visible red beam Beam is bore-sighted to within 2 milliradians and 0.25 mm of the housing centerline Useful for long-range sensing, or for sensing very small objects or profiles; excellent mechanical repeatability in position-sensing applications Features 12.7 mm diameter smooth aluminum barrel 10 V dc to 30 V dc supply voltage Compatible with a variety of photoelectric receivers Features collimated, apertured beam 2 mm in diameter, divergence of less than 1 milliradian Delivers excellent mechanical repeatability in position-sensing applications Available with unterminated, 2 m (6.5 ft) cable or 150 mm (6 in) quick-disconnect cable Modulated beam (33 khz, 25% duty cycle) WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. CAUTION: Never stare directly into the sensor lens. Laser light can damage your eyes. Avoid placing any mirrorlike object in the beam. Never use a mirror as a retroreflective target. CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit must be returned to the manufacturer. Models Model Range Connector 1 Supply Voltage Effective Beam at Receiver at 25 C M126E2LD M126E2LDQ Range varies, depending on which receiver is used (see Excess Gain on page 4) 2 m (6.5 ft) unterminated 15 mm (6 in) PVC cable with 3-wire Pico-style quick disconnect 10 V dc to 30 V dc Opposed Distance Beam Width 1.5 m (5 ft) 5 mm (0.20 in) 3 m (10 ft) 6.5 mm (0.26 ft) 6 m (20 ft) 9.5 mm (0.37 ft) 15 m (50 ft) 19 mm (0.75 ft) 30 m (100 ft) 34 mm (1.34 in) Installation Mounting Mounting suggestions: To take advantage of the bore-sight beam placement offered by the M12 laser emitter, use a two-part clamp mount or a mounting block with a precision-drilled hole. Allow minimum clearance for the 12.7 mm (0.50 in) diameter housing, maximum diameter 12.83 mm (0.505 in). 1 To order the 9 m (30 ft) PVC cable model, replace the suffix "Q" with "W/30" in the model number. For example, M126E2LD W/30. Models with a quick disconnect require a mating cordset. Original Document 52989 Rev. D 25 October 2017 52989

Clamp on both sides of the label. Do not clamp only on the labeled area. Use only plastic-tipped screws or set screws not metal to avoid compression of the housing. Mounting bracket assembly model SMB46X3 is recommended for use with the M12. The assembly includes: A black-anodized aluminum block with holes drilled for mounting in any of 3 directions with plastic set screws An adjustable stainless steel bracket with 3 spring-loaded screws (2 of the screws are used for precise alignment) The mounting block, model SMB127, can be ordered separately. Figure 1. Three Possible M12 Orientations 1. Insert the laser emitter into the SMB127 mounting block, through any of the three holes. 2. Make sure that the label area of the emitter is not aligned with a set screw. 3. Tighten the set screws, using the supplied 3/64-in Allen wrench, so that the emitter is held snugly in place. 4. Mount the block to the adjustable baseplate (or to your own bracket). 5. Mount the bracket base using your own M5 or #10 screws or bolts. 6. Check for alignment (see Alignment). 7. Tighten or loosen one or two of the precision alignment screws, using the supplied 2 mm Allen wrench, until the laser is accurately aligned. Wiring Quick disconnect (QD) wiring diagrams are functionally identical. 3 1 4 Beam Enable 10-30V dc + Key 1 = Brown 3 = Blue 4 = Black Alignment M12 laser emitters have a beam divergence of only 0.03 (0.5 milliradians) at 25 C (77 F) ambient temperature (see Figure 2 on page 3). This translates, for example, to a beam diameter of only 9.5 mm (0.37 in) at a distance of 6.1 m ( 20 ft). Consequently, there is very little forgiveness for angular misalignment. 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 52989 Rev. D

Laser Emitter Approx. 2 mm Approx. 0.5mrad = 0.029º Sensing Distance = X W W = 2 mm + 2X(tan.0029º) = 2 mm + X(0.001) Opposed Distance (X) Beam Width (W) 1.5 m (5 ft) 5.0 mm (0.20 in) 3 m (10 ft) 6.5 mm (0.26 in) 6 m (20 ft) 9.5 mm (0.37 in) 15 m (50 ft) 19 mm (0.75 in) 30 m (100 ft) 34 mm (1.34 in) Figure 2. M12 laser emitter beam divergence at 25 C (beam size vs. distance) The beam size listed in Figure 2 on page 3 is also the effective beam size at the receiver. The effective beam is equal to the minimum opaque object profile required to block the light beam. The beam size at the emitter is 3.5 mm (0.14 in) diameter. The effect of angular misalignment is dramatic. Laser emitters require their beam center to directly strike the receiver lens. Figure 3 on page 3 shows how far the laser beam will miss the center of the receiver lens for each degree of angular misalignment (in any plane). Note that even at only a 5 ft range, one degree of misalignment causes the laser beam to miss the lens of most receivers. Ø = Misalignment Angle Y Laser Emitter Sensing Distance = X Y = X(tan Ø) Opposed Distance (X) Beam Displacement (Y) for 1 of Misalignment 1.5 m (5 ft) 25 mm (1 in) 3 m (10 ft) 50 mm (2 in) 6 m (20 ft) 100 mm (4 in) 15 m (50 ft) 250 mm (10 in) 30 m (100 ft) 500 mm (20 in) Figure 3. Beam displacement per degree of misalignment Alignment Tip: The visible red beam of the laser emitter is easily seen in subdued lighting. Alignment: 1. At opposed distances of up to 3 m (10 ft), attach a sheet of white paper directly in front of the receiver lens. 2. Mark the location of the lens center on the paper. Use this mark as an aiming target. 3. Sight along the beam from directly behind the laser emitter. 4. Adjust the emitter mounting until the red image (the dot of red light) is centered exactly on the mark. 5. Remove the paper and check the response of the receiver. For longer distances (up to 7.6 m or 25 ft), replace the white paper with a 102 mm 102 mm (4 in 4 in) square of high-grade retroreflective tape (Banner model BRT-THG-4X4-5 or equivalent). For greater distances, use a larger sheet of retroreflective material. Never use a mirror as an alignment target. P/N 52989 Rev. D www.bannerengineering.com - Tel: +1-763-544-3164 3

Target Receiver M12 Figure 4. At long distances, use retroreflective tape to locate the beam at the receiver location. Specifications Supply Voltage and Current 10 V dc to 30 V dc (10% max. ripple) at less than 30 ma Supply Protection Circuitry Protected against reverse polarity, transient voltages, and electrostatic discharge Delay at Power-Up Less than 30 milliseconds Sensing Beam Visible red Class 2 laser, 650 nm (temperature coefficient 0.2 nm/ C) Pulse Width: 7 µs Rep Rate: 30 µs Peak Output Power: 2.8 milliwatts Beam Diameter at Aperture Approximately 3.5 mm (0.14 in) diameter Beam Placement Within 0.25 mm (0.01 in) and ±2 milliradians of mechanical centerline axis of housing Beam Divergence ± 0.5 milliradians typical at 25 C; ±1.0 milliradians at operating temperature extremes Laser Classification Class 2 laser product; complies to 21 CFR 1040.10, EN 60825-1:2001 except for deviations pursuant to laser notice 50, dated 7-26-01 Laser Control Beam enable: Apply + 10 V dc to 30 V dc to black wire Beam inhibit: Apply 0 V or by opening circuit Enable delay: Less than 30 milliseconds Inhibit delay: Less than 1 milliseconds Indicators Indicators are visible through the rear cover Green indicates power applied Amber indicates laser enabled Connections 2 m (6.5 ft) unterminated 3-wire PVC-jacketed high-flex cable, 9 m (30 ft) unterminated 3-wire PVC-jacketed high-flex cable, or 150 mm (6 in) PVC cable with a 3-pin M8/Pico-style male quick disconnect (QD) Construction 12.7 mm (0.50 in) dimeter smooth aluminum barrel; black hard-coat anodized finish MIL-A-8625 Type 2, Class 2 Operating Temperature 0 C to +40 C (+32 F to +104 F) 90% at +50 C maximum relative humidity (non-condensing) Environmental Rating NEMA 6; IEC IP67 Certifications Product Label M126E2LD bu - 10-30 VDC bn + bk LASER (+ON, -OFF) Pulse Power< 2.8 mw, 650-670 nm, 33 khz, 7 S Pulse. Complies with 21 CFR 1040.10 and EN60825-1:2001 except for deviations pursuant to laser notice No. 50, dated 7-26-01 LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. Aperture/Caution Label (Do not clamp only in this area) See "Connections" in Specifications Green LED Indicates power applied LASER RADIA DO NOT ST INTO BEA Peak Power: 2.2mW, 0.36 33kHz 25% duty cycle Amber LED Indicates laser enabled ø12.7 mm (0.50") 57 mm (2.25") Excess Gain The Excess Gain of the M12 emitter is dependent on the particular receiver used. The following is a comparison of the excess gain for various recommended receivers at 15 m (50 ft). 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 52989 Rev. D

Receiver Excess Gain at 15 m (50 ft) MULTI-BEAM SBRX1 19,000 SBR1 19,000 SBRXD1 19,000 SBRD1 19,000 MAXI-BEAM RSBR 14,000 RSBRSR 1,500 VALUE-BEAM SMW95R 34,000 SMI91RQD 18,000 EZ-BEAM T18SN6R 7,500 T30SN6R 7,500 S12SN6R 7,500 Receiver Excess Gain at 15 m (50 ft) MINI-BEAM SM31R 2,500 SM31RL 17,000 SM31RMHS 1,800 SM31RLMHS 11,000 ECONO-BEAM SE61R 600 SE61RMHS 500 Others SM51RB 1,200 Q23SN6R 400 Q10AN6R 250 Q45BB6R 9,000 For information on compatibility of the M12 emitter with other Banner photoelectric receivers contact Banner Engineering. Accessories Mounting Brackets SMB46X3 Assembly with mounting block and adjustable bracket Includes: 2 mm Shortarm hex key 3/64-in Shortarm hex key 4 Set screws 65 36 SMB127 Mounting block only Includes: 3/64-in Shortarm hex key Ø6.6 4 Set screws 45 61 21 36 36 3 X Ø12.9 Quick-Disconnect Cables 3-Pin Threaded M8/Pico-Style Cordsets Model Length Style Dimensions Pinout (Female) PKG3M-2 PKG3M-5 PKG3M-7 2 m (6.56 ft) 5 m (16.40 ft) 7 m (22.97 ft) 35 Typ. Straight ø 9.5 4 3 1 PKG3M-9 PKG3M-10 9 m (29.53 ft) 10 m (32.81 ft) M8 x 1 1 = Brown 3 = Blue 4 = Black P/N 52989 Rev. D www.bannerengineering.com - Tel: +1-763-544-3164 5

Retroreflective Tape Model Reflectivity Factor Maximum Temperature Size BRT-THG-4X4-5 0.7 +60 C (+140 F) 100 100 mm (package of 5) Model Reflectivity Factor Maximum Temperature Size BRT-THG-8.5X11-2 0.7 +60 C (+140 F) 216 280 mm (package of 2) Model Reflectivity Factor Maximum Temperature Size BRT-THG-18X36 0.7 +60 C (+140 F) 457 914 mm (single sheet) Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. Banner Engineering Corp. All rights reserved