Universal Dimmer E450UD Series. Installation Instructions

Similar documents
Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Dimmer / Fan Controller Installation Instructions

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Mains Power Filter 970MF10 970MF20. Installation Instructions

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

Light Level Detector, Surface Mount 5754PE. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Passive Infrared Motion Detector 5420/90P. Installation Instructions

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Installation Instructions

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

Airflow. Add a little Sunshine to your bathroom

Motion sensors for every application

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Universal Clamp Meter

SMART HOME LIGHTING CONTROL C LIPSAL

Pushing Boundaries in dimming technology

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

Lighting and Energy Control

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

Lighting & Energy Efficiency

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

Mira Vision Wireless Controller

Lighting and Energy Efficiency

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

6.5L SLOW COOKER INSTRUCTION MANUAL

Model pictured: RPA3CI6SS/WH

60cm Built-In Ceramic Cooktop

C-Bus Neo Range Installation Instructions. 5050NL Series

TT302 (200W) Wireless receiver Pull cord Dimmer

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

FANAWAY LED EVO1 RETRACTING BLADE CEILING FAN

Intercom Systems Video Intercoms

Ceiling Mounted Ducted Exhaust Fan Kit

FUTURA ECO SERIES CEILING FAN

Abella Digital Fade Dimmer

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B

all-rounder Mini Compact Bagless Vacuum Cleaner Cyclonic Bagless Technology Washable HEPA Filtration Compact, Lightweight & Stylish Design all-rounder

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

LUCCI FUTURA MOOD LED CEILING FAN

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

INTENSA MRM0115 MRM0220 MRM0620 INTERIOR & EXTERIOR LED LIGHT. Operating Instructions

SHUTTLE BELL-PRESS DIMMER DATA SHEET

Flexibility from floor to ceiling

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

52 BERKSHIRE CEILING FAN

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

Consumer Switchboards 4CS & 4FCS. Installation Instructions

FUTURA SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

LUCCI AIRFUSION FRASER DC CEILING FAN

48 TAYLOR CEILING FAN

MILLI CUBE HEATED TOWEL RAIL 825 X 600

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

VERSA INDOOR OLED LIGHT. Operating Instructions

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

C-Bus Application Note. Function Rooms and Ballrooms. Overview

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

52 STRATHMERE CEILING FAN

Sunbeam Tower Fan with Night Mode

LUCCI NORDIC DC CEILING FAN

MK Dimmers. Compatibility Guide

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

C-Bus Reflection Range Installation Instructions

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

Selection Guide. Tastic Eco Tastic Easy Duct Tastic Easy Duct Smart Switch Tastic. 5 Year in home warranty.

"Options" Sensor Module

Dome Kettle. polished stainless steel body BTDK120

USER MANUAL. Adventure Kings 50L Refrigerator

Universal Fan and Light Remote Control

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

AERO SERIES CEILING FAN

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Dimmer Switch (3 Gang)

Reflector T2 and GU10 6,000 hours

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

52 CEILING FAN. Owner s Manual Models #50336, 50337

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

Transcription:

Universal Dimmer E450UD Series Installation Instructions

Table of Contents... 3... 3... 3... 4... 4... 5... 5 6.1 Wiring Details... 5 6.2 Soft-Start Feature... 5 6.3 Minimum Brightness Settings... 5 6.4 Multi-Gang Derating... 6 6.5 Thermal Overload Protection Circuitry... 6 6.6 Short Circuit Protection... 6... 6 7.1 One-Way Operation... 6 7.2 Two-Way Operation... 6... 7... 8 2 of 8 2014 Schneider Electric. All Rights Reserved.

1.0 Product Range Dimmer, Universal, 220-240V AC, 50Hz, 450W 32E450UDM 32E450UD 2032E450UD 80E450UDM M8082E450UD S8082E450UD 4062E450UDM 4062E450UD 4062E450UDN Z4062E450UDN 30 Series Mechanism Standard Range 2000 Series Classic C2000 Series Slimline Series Prestige Mechanism Prestige Series 80 Series Mechanism Modena 8000 Series Strato 8000 Series Saturn Series Mechanism Saturn Series Saturn Series with LED indicator Saturn ZEN Series with LED indicator * Please note that these products are also available in other configurations and in a wide range of colours. For further information, please contact your nearest Clipsal and Schneider Electric Partner Business Representative. 2.0 Description This product must only be installed by a licensed electrical contractor or other persons authorised by legislation to work on the fixed wiring of any electrical installation. The Clipsal E450UD Series Universal Dimmer is a separately switched, compact, modular dimming mechanism rated at 450W, and designed for universal load compatibility. The unit utilises powerful and sophisticated dimming technology to provide full control of almost any type of load, whether it be incandescent lighting, 240V halogen or dichroic lamps, iron-core or electronic low voltage lighting transformers as used in downlight applications. Even small motor loads, such as ceiling sweep and exhaust fans can be controlled. The Universal Dimmer also incorporates over-current and over-temperature protection devices and is capable of withstanding persistent short circuit conditions, making it the most rugged, robust and reliable dimmer mechanism ever produced. c-thru The Clear Choice helping you select the right dimmer, first time every time! 2014 Schneider Electric. All Rights Reserved. 3 of 8

3.0 Features Separately switched compact modular dimming mechanism. 450W power rating. Soft-start operation. Preset minimum brightness. Wall or architrave mounting options. Wide range of plate styles and colour variants available. Suitable for one-way or two-way operation. Suitable for new installations or retro-fit applications. Inbuilt over-current and over-temperature protection. Short circuit protection. 4.0 Load Compatibility The Clipsal E450UD Series Dimmer is a part of the c-thru dimmer range and offers true universal load compatibility. Suitable for a wide range of load types. - Incandescent lamps (tungsten filament). - 240V halogen/dichroic lamps. - Low voltage downlights using iron-core or electronic transformers. - Dimmable LED lamps. - Small motor loads (such as ceiling sweep and exhaust fans). Fitted with suppressors to minimise radio frequency interference. Complies with Australian and International EMC Standards. Incandescent Lighting MV Halogen/Dichroic Lamps 450W Low Voltage Halogen/Dichroic Lighting with Iron-Core Transformers 450W Low Voltage Halogen/Dichroic Lighting with Electronic Transformers Dimmable Compact Fluorescent Lamps (Selected makes/models only. Please contact CFL supplier for compatibility advice.) Dimmable LED Lighting (Please visit clipsal.com/load for recommended loads. For other loads, contact the LED supplier for compatibility advice.) Small Motor Loads - Exhaust fans (shaded pole induction motors). - Ceiling fans (split-phase induction motors). 450W 200W 300W 450W 1. Dimming performance may vary between lamp manufacturers. 2. Use only dimmable CFL/PL/LED lamp types, compatible with phase angle control dimming techniques. 3. Due to the nature of dimmable CFL loads, lamp strike cannot be guaranteed upon start-up. To maximise the probability of successful lamp strike, turn on with the knob in an advanced setting. 4. Minimum load: visit clipsal.com/load for recommended minimum load of Clipsal Lamps. For other loads, install a 31LCDA Load Correction Device for loads less then 10W. 5. Some lamps may exhibit unexpected performance characteristics when cold. Dimming performance should improve once the lamp warms up. 4 of 8 2014 Schneider Electric. All Rights Reserved.

6. It is recommended that when using electronic transformers, each be loaded to at least 75% of its maximum rated load. This reduces the possibility of lamp flicker when dimming which is common with some transformers. Refer to the manufacturer s specifications for the transformer being used. 7. Use only iron-core transformers compatible with electronic switches/phase controlled dimmers as recommended by the manufacturer. 8. Any number of low voltage lighting transformers can be used, providing the total lamp wattage does not exceed the maximum load rating of the dimmer. 9. Mixed load types are permitted, though not recommended. Test thoroughly to ensure normal operation throughout the dimming range. Use at own risk. 10. When controlling small motor loads, occasionally audible noise (hum) may be heard as a characteristic of normal operation. This is largely a function of the motor construction, and is consequently excluded from the warranty conditions provided with this product. 11. This product is rated for indoor use only. It is not suitable for outdoor use or installation in a roof space. 12. Operation from elevated voltages or temperatures may cause the thermal protection circuitry to operate. In the case of significant overload, the thermal fuse may be blown, rendering the dimmer inoperable. This may occur if abnormal operating conditions are detected by the dimmer, even in the case where the lamp wattage does not exceed the dimmer rating. Reduce the size of the connected load or use a different brand of lamp to prevent reoccurrence. 5.0 Incompatible Loads This dimmer is not compatible for use with non-dimmable linear/compact fluorescent lamps. Exercise care when using dimmable CFL/PL/LED load types. Use only lamps/ballasts that are compatible with phase angle control. Refer to the manufacturer s specifications for recommendations. Dimmer warranty is void when controlling incompatible load types as determined by Clipsal by Schneider Electric Australia. Visit clipsal.com/load for recommended LED loads. Some loads may require a 31LCDA Load Correction Device in order to ensure correct operation. 6.0 Installation Instructions 6.1 Wiring Details 1. Disconnect power to the relevant circuit at the main switchboard. 2. Remove existing switch from wall. 3. Connect the dimmer in accordance with the wiring diagrams shown over the page. 4. Refit switch plate to wall and fit fascia. 5. Reconnect power. 6. Fit dimmer knob to shaft (ensure correctly aligned with shaft). 7. Turn switch on and check dimmer operation by turning control knob through full range. The Universal Dimmer does not incorporate a kick-start feature as is standard for other c-thru Fan Controller models. The control knob must be sufficiently advanced when turned on, in order to achieve reliable motor starting. 6.2 Soft-Start Feature The Universal Dimmer incorporates a soft-start feature providing a noticeably smooth lamp illumination at turn on. This feature also minimises lamp filament start up stress, which may increase lamp life. 6.3 Minimum Brightness Settings The minimum brightness level has been factory preset to suit most applications. 2014 Schneider Electric. All Rights Reserved. 5 of 8

6.4 Multi-Gang Derating For applications where E450UD Series Dimmers are multi-ganged, derate the maximum load rating of the unit according to the derating table shown on the right. 6.5 Thermal Overload Protection Circuitry The E450UD Series Dimmers incorporates two levels of thermal overload protection. Thermal Overload Compensation Automatically reduces lamp brightness should the dimmer be inadvertently overloaded. Primary defence against overload or short circuit. Resets automatically once overload conditions are corrected. Thermal Cut-Out The unit contains a non-resettable thermal fuse device designed to blow in case of catastrophic circuit failure. This is a secondary protection measure intended to operate as a backup in case of persistent or prolonged overload conditions. If the thermal cut-out fuse blows, then the dimmer will be rendered permanently inoperable and must be replaced. Any significant overload should be avoided in order to prevent damage to the load, fixed wiring of the installation or other hardware connected to the affected circuit. 6.6 Short Circuit Protection The E450UD Series Dimmers feature short circuit protection, designed to ensure the dimmer can survive in case of wiring fault or catastrophic failure of the load. The short circuit protection feature also allows the dimmer to be used in conjunction with lamps oriented in the vertical direction as commonly found in chandeliers (something not previously recommended with any other dimmer available). 7.0 Wiring Diagrams 7.1 One-Way Operation A De-rate the maximum load of the unit for multi-gang applications as per the table shown below. Do not operate the unit at elevated temperatures. Decrease the size of the load to prevent re-occurence. 7.2 Two-Way Operation 1 450W 300W 2 350W 250W 3 250W 200W C 1 Loop 2 A C 1 Loop 2 C 1 Loop 2 Switch Mech Switch Mech LOAD LOAD Dimmer Mechanism Dimmer Mechanism N N If the unit is wired for two-way operation it can be switched ON or OFF from either location but the lamp brightness can only be adjusted from one location. Two or more dimmers cannot be connected in parallel or series to control the same load from two different locations. Dimmer mechanism wiring is NOT polarity sensitive. 6 of 8 2014 Schneider Electric. All Rights Reserved.

8.0 Electrical Specifications 220 240V 50Hz 450W @ 240V 400W @ 220V Derate for multi-gang applications (refer to table on page 6) 10W Leading Edge/Trailing Edge Phase Control (dynamically auto-selected) Incandescent Lighting Halogen 240V lamps Low Voltage Lighting with Iron-Core Transformers Low Voltage Lighting with Electronic Transformers Dimmable Compact Fluorescent Lamps (selected makes/models only, 200W max.) Dimmable LED Lighting (selected makes/models only, 300W max.) Small Motor Loads Non-Dimmable Fluorescent/Compact Fluorescent Lighting 84mm Australian Pattern Plate 25g Dimmer Mechanism Only AS/NZS3100, AS/NZS3133, IEC60669 Series AS/NZS CISPR15, IEC60669-2-1 (26.1,26.2), IEC61000-3-2 (except when used in conjunction with electronic loads, e.g. dimmable CFL loads) Specifications Typical @ 240V 25 o C Suitable for Indoor Use Only No User Serviceable Parts Inside 2014 Schneider Electric. All Rights Reserved. 7 of 8

9.0 Warranty Statement 1. The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Clipsal product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2. The warrantor is Schneider Electric. 3. This Clipsal product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. 4. Schneider Electric reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. 5. This warranty is expressly subject to the Clipsal product being installed, wired, tested, operated and used in accordance with the manufacturer s instructions. 6. All costs of a claim shall be met by Schneider Electric, however should the product that is the subject of the claim be found to be in good working order all such costs shall be met by the claimant. 7. When making a claim the consumer shall forward the Clipsal product to the nearest office of Schneider Electric with adequate particulars of the defect within 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. Tel 1300 2025 25 Fax 1300 2025 56 Tel 0800 652 999 Fax 0800 100 152 Schneider Electric (Australia) Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. 2014 Schneider Electric. All Rights Reserved. Trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. F2010/07 SEAU122703 November 2014