Cl. I, Div. 2, Groups A, B, C, D (All mounting except stanchion) Wet Locations NEMA 3, 3R L Applications: Vaporgard series incandescent luminaires are used: Indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required In tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem For flush or surface mounting on ceiling or wall; pendant or in conduit systems; with or without a cast outlet box Features: Designed to exclude dirt, moisture and corrosive vapors from the interior of the luminaires and the conduit system There are no screws to remove as the shock-absorbing socket strap is keyhole slotted and removes quickly for ease of wiring The glass globe-guard assembly is installed and/or removed as a unit, making it necessary to handle only one piece in relamping There are no crevices to accumulate a dirt or dust build-up and fixture has an attractive finish with a smooth, dust and dirt shedding design Configurated glass globe has vertical fluting and stippled bottom which provides for more even light distribution and glare elimination For non-hazardous locations, shatterproof plastic polycarbonate globes are available for use with the 200 watt series Reversible offset socket mounting strap permits use of various size lamps while holding light center in same position for maximum light output and efficiency Shock absorbing medium base lamp socket Krydon fiberglass-reinforced polyester reflectors: Reflectance is equivalent to the finest porcelain enamel Cannot corrode no enamel to chip and rust Ultraviolet inhibitors are incorporated in the material to prevent discoloration and brittleness Certifications and Compliances: Wet locations NEC/CEC: Class I, Division 2 UL Standard: 598 CSA Standard: C22.2 No. 9 UL/CSA Fixture Fitting Standard Materials: Bodies and guards copper-free aluminum Globes -Heat and impact resistant tempered glass -Colored glass non-tempered (G55, G56, G57, G58) -Plastic polycarbonate (G63, G65, G67) Reflectors Krydon fiberglassreinforced polyester Standard Finishes: Bodies and guards epoxy powder coat Krydon material high reflectance white Options: The following options are available from the factory by adding suffix to fixture Cat. No.: Description Suffix Teflon coating on globe for increased shatter protection (G24 globe series only)... S808 250V nameplate for export applications... /250 Plastic polycarbonate see globe... page 894 Ratings (Electrical/): Up to, PS-30 medium base lamp /2" to /4" hubs 20V nameplate is standard for NEC compliance 250V nameplate is optional. Supplied when ordered with suffix: /250 Class I, Division 2 Temperature Performance Data: (Based on 40 C ambient) Lamp Watts T-Number Supply Wire C 50 T2A 50 C 200 T2B 200 C 300 T2B 50 C L www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business 89
L VAPORGARD Incandescent Enclosed and Gasketed Cl. I, Div. 2, Groups A, B, C, D Wet Locations NEMA 3, 3R Pendant Mount VDA /2" 50 Pendant Body Globe Guard VDA5GP VDA5 G54 P50 3 50 watt /4" 50 VDA25GP VDA25 G54 P50 " 50 A-2 VDA35GP VDA35 G54 P50 /2" 200 VDA2GP VDA2 G24 P2 3 /4" 200 VDA22GP VDA22 G24 P2 " 200 VDA32GP VDA32 G24 P2 /2" 300 VDA3GP VDA3 G34/G25 P22 3 /4" 300 VDA23GP VDA23 G34/G25 P22 " 300 VDA33GP VDA33 G34/G25 P22 Thru-Feed VDC /2 or 3 /4" 50 /2 or 3 /4" 200 /2 or 3 /4" 300 50 watt A-2 Thru-Feed Body Globe Guard VDC25GP VDC25 G54 P50 VDC22GP VDC22 G24 P2 VDC23GP VDC23 G34/G25 P22 L Ceiling Mount for Recessed 4" Round Box VXH 50 200 300 50 watt A-2 Lamp Socket Body Globe Guard VXH5GP VXH5 G54 P50 VXH2GP VXH2 G24 P2 VXH3GP VXH3 G34/G25 P22 Ceiling Mount with Junction Box VXHF Lamp Socket Body Globe Guard Junction Box /2 or 3 /4" 50 50 watt A-2 VXHF25GP VXH5 G54 P50 VXF20 /2 or 3 /4" 200 VXHF22GP VXH2 G24 P2 VXF20 /2 or 3 /4" 300 VXHF23GP VXH3 G34/G25 P22 VXF20 Note: All fixtures supplied with /2" reducers, except for pendant mount. 892 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business
Enclosed and Gasketed Cl. I, Div. 2, Groups A, B, C, D Wet Locations NEMA 3, 3R L Wall Mount VXHT /2 or 3 /4" 50 /2 or 3 /4" 200 /2 or 3 /4" 300 50 watt A-2 Wall Bracket Mounting Module Body Globe Guard VXHT25GP VXT20 VXH5 G54 P50 VXHT22GP VXT20 VXH2 G24 P2 VXHT23GP VXT20 VXH3 G34/G25 P22 Wall Mount Adapter Kit Description Mounts wall mount VXHT to a 4" Round Box VXT K Wall Mount with Junction Box VXHBF /2 or 3 /4" 50 /2 or 3 /4" 200 /2 or 3 /4" 300 50 watt A-2 Wall Bracket Mounting Module Body Globe Guard Junction Box VXHBF25GP VXT20 VXH5 G54 P50 VXF20 VXHBF22GP VXT20 VXH2 G24 P2 VXF20 VXHBF23GP VXT20 VXH3 G34/G25 P22 VXF20 L Stanchion Mount VXHA /4" /4" /4" 50 watt A-2 Stanchion Mounting Module Body Globe Guard VXHA45GP VXA4 VXH5 G54 P50 VXHA42GP VXA4 VXH2 G24 P2 VXHA43GP VXA4 VXH3 G34/G25 P22 Note: All fixtures supplied with /2" reducers, except for pendant mount. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business 893
L VAPORGARD Incandescent Parts and Accessories Medium Base Lamp Receptacle with Strap Shock Absorbing Globes and Guards Plastic Globes L Description Shock Absorbing Medium Base Lamp Receptacle with Strap V84 Reflectors Dome 30 Angle Dome 30 Angle 50 watt, A-2 RD64 RA64,, A-25, PS-25 and, PS-30 RD7 RA7 VXFT 5 s, 4 Plugs (In.) /2 VXFT0 3 /4 VXFT20 50 and globe 50 Watt, A-2 globe Guards for Glass Globes (Not for use with plastic globes) Guard P50 and P2 200 Watt,, A-25, PS-25 300 Watt, PS-25, PS-30 Color Clear (heatresisting) G54 G24 G34G25 Green G55* G25 Blue G56* G26 Red G57* G27 Amber G58* G28 Guard P22 50 watt, A-2 P50,, A-25, PS-25 P2, PS-30 (with G25 only) P22 Shatterproof polycarbonate plastic globe Applications: For use in: Food processing plants and canneries, dairies, breweries and bakeries Emergency lighting Features: Shatterproof, which precludes contamination of food products with broken particles of glass Designed to comply with U.S. Dept. of Agriculture specification for food processing plants Provides protection against vandalism, with resultant lower replacement and maintenance costs Particularly adaptable for use on emergency police or fire alarm boxes Same size as G24 series glass globes. Existing installations can be changed to plastic globes simply by replacing globe For use with series luminaires such as VDA22, etc. For use without guard Color Wattage, Natural, G63 Green, G65 Red, G67 Note: Polycarbonate globes for non-hazardous locations only. Mounting Adapter Kit For use when rear wiring entry is required. Use in lieu of VXF0 or VXF20. VXT-K Prior to wash-down, globes must be cool. Lamp must be mounted in vertical position base up to 45 C (stanchion) only. *With G55, G56, G57, G58 color globes, maximum lamp size is 60 watt for outdoor applications. G24 is available with a TEFLON coating for increased shatter protection by adding suffix S808 (stanchion) only. Globe G25 required when guard P22 is used. Use globe G34 when guard is not used. All glass globes are configured type, having fluted side and stippled bottom. Description Allows for the mounting of non- Eaton's Crouse-Hinds outlet boxes to the VXT20 wall mount VXT K bracket and VXH ceiling mount bracket 894 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business
Family Tree L 50W VDA5 VDA25 VDA35 VDA2 VDA22 VDA32 VDA3 VDA23 VDA33 PENDANT VDA/VFA PLATE GASKET 0305729 030507 VXT-K ADAPTER KIT FOR MOUNTING VXT20 AND VXH5, VXH2, VXH3, VFH22 TO 4" OULET BOX (BY OTHERS) VXF20 VXFT20 (ORDER SEPARATELY) VFA22 VFA222 VFA322 50W VDC25 VDC22 VDC23 VFC222 50W VXH5 VXH2 VXH3 VFH22 VXH5 VXH2 VXH3 VFH22 50W VXHF25 VXHF22 VXHF23 VFHF222 THRU FEED VDC/VFC BOX MOUNTING VXH/VFH BOX MOUNTING VXHF/VFHF G54 CLEAR HEAT RESISTING G55 GREEN G56 BLUE G57 RED G58 AMBER 50W GLOBE & GUARD G54 G24 CLEAR HEAT RESISTING G25 GREEN G26 BLUE G27 RED G28 AMBER G63 CLEAR PLASTIC POLYCARBONATE G65 GREEN PLASTIC POLYCARBONATE G67 RED PLASTIC POLYCARBONATE (NO GUARD AVAILABLE WHEN ORDERED WITH PLASTIC GLOBE) & GLOBE & GUARD G24 GLOBE WITHOUT GUARD G34 CLEAR HEAT RESISTING P50 P2 RD64 RA64 RD7 L 50W VXHBF25 VXHBF22 VXHBF23 WALL & JUNCTION BOX VXHBF/VFHBF GLOBE WITH GUARD G25 GLOBE & P22 GUARD CLEAR HEAT RESISTING RA7 VXT20 VXH5 VXH2 VXH3 VFH22 VFHBF222 GASKET 030506 VXF20 VXFT20 50W VXHT25 VXHT22 VXHT23 WALL MOUNT VXHT/VFHT VFHT222 VXA4 VXH5 VXH2 VXH3 VFH22 50W VXHA45 VXHA42 VXHA43 VFHA422 ANGLE ADAPTER STANCHION MOUNT VXHA4/VFHA4 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business 895
L VAPORGARD Incandescent Photometric Data Luminaire VXHA45GPRA Lamp: 50W/A-2 Bare Lamp Lumens: 2850 With Guard 490 52.3 Without Guard 88 66.0 Luminaire With Globe, 30 Angle Reflector and With or Without Guard Lamp: 00W/A-2 through / Bare Lamp Lumens: 4000 All data provided is for / incandescent lamp. Use following candlepower/lumen multipliers for other lamp sizes: 00W 0.42; 50 W0.7 Measurements taken from A-A' plane. Measurements taken from A-A' plane. L Luminaire VXHA42GPRA Lamp: /PS-30 Bare Lamp Lumens: 6300 Measurements taken from A-A' plane. With Guard 3630 57.6 Without Guard 427 67.8 Lamp Without Guard With Guard 00W 4 949 50W 890 582 / 2700 67.5 2260 56.5 /PS-25 274 89 Luminaire With Globe, 30 Angle Reflector and With or Without Guard Lamp: /PS-30 Bare Lamp Lumens: 6000 With Guard 3360 56.0 Without Guard 3954 65.9 Measurements taken from A-A' plane. 896 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business
Photometric Data L Lamp: 00W/A-2 through /PS-25 Bare Lamp Lumens: 4000 All data provided is for / incandescent lamp. Use following candela/lumen multipliers for other lamp sizes: 00W 0.42; 50W 0.7; /PS-25 0.82 Luminaire With Globe and With or Without Guard Example: Zonal Lumens for / lamp with guard for 0 40 is 272 Zonal Lumens for 50W lamp with guard for 0 40 is 272 x 0.7 = 90. Luminaire With Globe, Dome Reflector and With or Without Guard Example: Zonal Lumens for / lamp with guard for 0 40 is 948 Zonal Lumens for 50W lamp with guard for 0 40 is 948 x 0.7 = 664. Coefficient of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. Wall 2 3 4 5 80 70 50 30 50.654.549.47.407.353 30.608.486.400.333.282 0.567.432.345.277.228 50.603.506.434.375.326 30.563.449.370.309.260 0.523.40.320.257.2 50.509.424.363.32.273 30.477.380.33.260.220 0.449.34.27.28.79 50.422.349.297.255.223 30.399.35.259.24.80 0.376.285.225.80.47 50.343.280.237.202.76 0 30.324.253.206.70.42 0.307.230.80.43.5 Eff. Ceil. Wall 6 7 8 9 0 80 70 50 30 0 50.35.279.249.226.20 30.244.20.83.62.40 0.93.64.37.8.00 50.289.257.230.208.85 30.225.94.70.50.30 0.77.50.27.0.093 50.242.25.92.75.56 30.89.63.43.26.09 0.50.26.06.092.077 50.98.75.58.43.28 30.55.34.6.03.088 0.23.02.086.075.06 50.57.40.24.4.0 30.22.06.09.080.068 0.096.080.066.057.045 Coefficient of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. Wall 2 3 4 5 50.604.522.454.395.347 80 30.576.480.404.340.290 0.552.444.364.298.248 50.59.52.445.387.339 70 30.565.472.398.336.286 0.543.440.36.296.246 50.564.490.428.372.327 50 30.544.457.387.327.280 0.526.428.354.292.245 50.54.470.4.358.35 30 30.525.444.377.39.273 0.509.49.348.288.24 50.52.452.396.345.304 0 30.507.429.367.3.268 0.494.409.342.283.238 Eff. Ceil. Wall 6 7 8 9 0 50.309.274.244.222.93 80 30.253.220.92.70.42 0.24.84.55.35.0 50.303.270.24.29.89 70 30.250.27.9.68.42 0.2.8.54.35.0 50.29.260.232.2.84 50 30.245.22.86.66.39 0.209.79.53.34.09 50.28.250.225.204.78 30 30.239.209.82.62.36 0.207.77.52.33.07 50.272.243.27.98.73 0 30.234.205.79.59.34 0.205.75.50.3.06 L www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business 897
L VAPORGARD Incandescent Photometric Data Lamp: /PS-30 Bare Lamp Lumens: 6000 Luminaire With Globe Only Luminaire With Globe and Dome Reflector L Coefficient of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. Wall 2 3 4 5 50.692.582.499.43.373 80 30.644.55.425.354.300 0.602.459.367.295.243 50.636.534.458.396.345 70 30.594.475.392.327.276 0.552.425.339.273.223 50.532.444.380.327.286 50 30.500.398.328.272.230 0.470.358.285.229.88 50.437.362.308.264.230 30 30.42.326.268.222.86 0.389.295.234.86.52 50.350.285.24.205.79 0 30.33.258.20.72.44 0.33.235.83.45.6 Eff. Ceil. Wall 6 7 8 9 0 50.333.295.263.238.22 80 30.258.223.94.70.47 0.205.73.45.25.05 50.305.27.24.29.94 70 30.238.204.78.57.36 0.88.58.33.5.097 50.253.224.200.8.62 50 30.98.70.48.3.3 0.57.32.0.095.079 50.204.80.62.46.30 30 30.60.38.9.05.090 0.27.05.088.075.06 50.58.4.24.4.0 0 30.23.06.09.080.067 0.096.079.066.055.044 Coefficient of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. Wall 2 3 4 5 50.766.67.587.54.454 80 30.734.62.528.448.385 0.706.579.482.398.334 50.750.657.577.505.443 70 30.720.60.52.444.380 0.694.573.477.395.332 50.77.630.555.485.429 50 30.693.592.507.432.372 0.672.558.468.390.329 50.688.606.535.468.44 30 30.670.575.494.422.364 0.65.546.460.385.325 50.663.584.56.452.400 0 30.647.557.482.42.357 0.632.534.452.379.32 Eff. Ceil. Wall 6 7 8 9 0 50.404.360.322.293.254 80 30.337.294.258.229.9 0.289.250.22.85.5 50.397.354.37.288.249 70 30.333.290.256.227.9 0.285.246.2.85.5 50.383.342.306.279.243 50 30.326.284.250.223.87 0.283.244.209.84.50 50.37.330.297.270.235 30 30.320.280.245.28.84 0.28.24.208.82.48 50.359.322.288.262.229 0 30.33.275.24.25.8 0.277.239.206.80.46 898 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business
Dimensions L Dimensions in Inches 50 watt,, A-2 PS-25, PS-30 a 2 7 /8 6 7 /8 6 7 /8 b /8 4 5 /8 4 5 /8 c 5 3 /8 6 6 d 3 3 /6 4 4 e 8 7 /6 9 /8 9 /8 f 2 4 4 g 8 3 /6 0 /2 2 h 9 0 3 /6 3 /8 j 4 /2 6 /6 6 /6 VDA VDC VXH and VXHF (Omit box for VXF ) L VXHT and VXHBF (Omit box for VXHB series) Dimensions in Inches a 50 watt, A-2 5 3 /8,, A-25, PS-25 and, PS-30 6 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 203 Eaton s Crouse-Hinds Business 899