i m a g e s t a n d a r d s 1

Similar documents
Sunoco Retail Image Guideline Document

Phillips 66 Shield. Image Guidelines Canopy. Version 1.0 DRAFT DRAFT CANOPY. Phillips 66 Shield Image Guidelines TABLE OF CONTENTS

CO. RD. 28 Yankee Doodle Road SITE. This map is for reference use only. This is not a survey and is not indtended to be used as one.

Canopy Signage and Graphics Section B

PARKLET PROPOSAL PACKAGE & PROCESS

Brand, Promotions and Visual Identity Guidelines for Channel Partners

LOGO & TRADEMARK USAGE GUIDE

3.10 ROW Overlay District

Certified Professional LOGO, TRADEMARK, AND USAGE GUIDELINES

CHAPTER BEAUTIFICATION AND LANDSCAPE MANAGEMENT

Society of Petroleum Engineers Graphic Standards Guide

Narcoossee Roadway Corridor

DOWNTOWN TRANSCONA URBAN DESIGN GUIDELINES

DEPARTMENT OF PLANNING JEFFERSON PARISH, LOUISIANA

Promoting your certification. Client instructions for use of the Bureau Veritas Certification certification marks

Promoting your certification

Village of Glenview Appearance Commission

Public Hearing, July 12, 2018

MIDTOWN MIXED-USE VILLAGE. TECHNICAL DATA SHEET COMPONENT C-1 FOR PUBLIC HEARING - PETITION NUMBER Project No RZ1.1. Issued.

Facilities Identification Signage

Zoning Ordinance Section 1.100

ABOUT SignResource Manufacturing Project Management

TOWNSHIP OF LOGAN SOIL & FILL IMPORTATION AND PLACEMENT APPLICATION SUBMITTAL CHECKLIST

M E M O R A N D U M July 27, 2018

Nassau University Medical Center Exterior Sign System Campus Wayfinding & Emergency Bid Document Set

Request Modification of Conditions (Automobile Service Station) Staff Recommendation Approval. Staff Planner Jimmy McNamara

REVISED THE CORPORATION OF THE CITY OF FERNIE DESIGN REVIEW PANEL MEETING

City of San Juan Capistrano Agenda Report

The Logo 2 The Colors 3 Typography 4 Corporate Statements 5 Targeted Corporate Statements 6 Promotional Guidelines 7 Promotional Materials 8

SUBCHAPTER 4-B GUIDELINES FOR THE B-3 COMMERCIAL CHARACTER AREA

D1 September 11, 2013 Public Hearing APPLICANT:

The Highway Overlay District applies to an area within the City of Papillion's zoning jurisdiction described as:

4.500 Preston Road Overlay District

COMMUNITY DESIGN. GOAL: Create livable and attractive communities. Intent

Section 511: 11 th Street Overlay District 1. Intent: 11 th Street is the primary entrance route into the city from the south, providing direct

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

DEPARTMENT OF PLANNING JEFFERSON PARISH, LOUISIANA

maurices STOREFRONT SIGNAGE STANDARDS Strip Center, Outlets, Malls, and Downtowns

Nationwide Signage & Graphics

Signage Design Concept Proposal

PLANNING APPROVAL & SIDEWALK WAIVER STAFF REPORT Date: December 1, 2016

11 May 9, 2012 Public Hearing APPLICANT: KROGER LIMITED PARTNERSHIP I

Earth Hour Brand Guidelines September 2008

City of Moline Sidewalk Café Guidelines

Department of Planning & Development Planning Unit

NATIONAL CREDIT UNION BRAND SIGNATURE

8 February 9, 2011 Public Hearing APPLICANT: 7-ELEVEN, INC.

Product Brand Standards

CHAPTER ADDITIONAL REQUIREMENTS IN THE NC, NEIGHBORHOOD COMMERCIAL ZONE

CHRISTMAS TREE LOT INFORMATION & REQUIREMENTS

Department of Planning & Development Planning Unit

Note: Staff reports can be accessed at Special Permit Application No.

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

CITY OF VAUGHAN EXTRACT FROM COUNCIL MEETING MINUTES OF SEPTEMBER 26, 2017

COUNCIL POLICY. 1. Removals. a) Dead or Hazardous Trees

PLANNED UNIT DEVELOPMENT APPLICATION

EXTERIOR SIGN PROGRAM FINAL DESIGN FEBRUARY 4, 2013

DEPARTMENT OF PLANNING JEFFERSON PARISH, LOUISIANA

12 January 12, 2011 Public Hearing APPLICANT: TAILWIND DEVELOPMENT GROUP,LLC PROPERTY OWNER: CITY OF VIRGINIA BEACH

PLANNING & REVIEW. Pittsburgh, PA. Ashley HomeStore Outlet

D3 January 14, 2015 Public Hearing

I Street, Sacramento, CA

MASH Implementation for Guardrail

general corridor design guidelines gen-0.0

6 November 13, 2013 Public Hearing APPLICANT: CAH HOLDINGS, LLC

Streetscape Patterns. Design Guidelines, Ridgewood Village Center Historic District, Ridgewood, N.J. page 20

Effective date of most recently amended section of Article III Chapter 7: 07/24/13. Copyrighted by the City of New York

Thanksgiving Point Office Site Plan Approval Planning Commission Report

PLANNED UNIT DEVELOPMENT STAFF REPORT Date: June 2, 2016

Memorials, Plaques & Interpretive Signs Policy

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Request Conditional Use Permit (Automobile Repair Garage) Staff Planner Kevin Kemp

Temporary Use Permit Application Check List

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Landscape and fencing requirements of this Chapter shall apply to all new landscaped areas.

Village of Glenview Appearance Commission

City of San Juan Capistrano Agenda Report

Page PRODUCT DESCRIPTION

VILLAGE OF SKOKIE Design Guidelines for Mixed-Use Districts NX Neighborhood Mixed-Use TX Transit Mixed-Use CX Core Mixed-Use

City of Surrey PLANNING & DEVELOPMENT REPORT File:

Permitting and Licensing for Hazardous Material Use and Storage

ARTICLE XVI LIGHTING, NOISE AND ODOR/ODOROUS MATTER Shelby County Zoning Regulations 2013

Business License Handbook. How to Open and Operate a Business in Blue Island

2 January 13, 2010 Public Hearing APPLICANT: AUTOBELL CAR WASH, INC

Town of Cedarburg Design Guidelines & Standards Commercial / Multi Family / Senior Care /Institutional/ Government Facilities Adopted August 6, 2014

STAFF REPORT. To: Planning Commission Meeting date: January 11, 2017 Item: UN Prepared by: Robert Eastman. RREF II-KI Promenade, LLC

Section General Tree Preservation Requirements for New Nonresidential and Residential Development

FREEWAY/TOURIST DISTRICT

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: May 18, 2017

a) That prior to the execution of the amending site plan agreement:

THE CITY OF MOBILE, ALABAMA

Design and brand guidelines

Request Change in Nonconformity. Staff Recommendation Approval. Staff Planner Jonathan Sanders

Canterbury City Council Military Road Canterbury Kent CT1 1YW. Title: CA/16/02745/ADV. Author: Planning and Regeneration.

CENTERS AND CORRIDORS

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

MISSION PARK AT HEARTHSTONE

EN RaychemRIM2StandardInstallationManual IM H /16 1

Request Conditional Use Permit (Automobile Service Station) Staff Recommendation Approval. Staff Planner Bill Landfair

OCEANFRONT RESORT DISTRICT FORM-BASED CODE. Sign Regulations (as amended Dec. 5, 2018)

Transcription:

image standards 1

Spirit Petroleum P.O. Box 1419 Soap Lake, WA 98851 Phone: (509) 203-7357 info@spiritpetroleum.com www.spiritpetroleum.com Revision: 12/16

Table Of Contents... Approved vendors. 1 Paint standards, colors and codes. 2 Replacement signs. 3 ID sign faces. 4 Price sign faces. 5 C-store sign faces 6 Service message and readerboard sign faces. 6 New signs. 7 Twin pole signs. 7 Single pole signs. 8 Single pole ID signs. 9 High rise ID signs. 10 Monument signs. 11 Illuminated channel letter and trim cap signs 12 Highway and flag signs. 13 Canopies. 14 Canopy basics and image segments. 14 Canopy graphic image segment application basics. 15 Canopy graphic installation specifications for canopies over 40 long. 16 Canopy graphic installation specifications for canopies under 40 long. 17 Optional graphic installation for wide canopies. 18 Standard T canopy graphic (short front) installation specifications. 19 Standard T canopy graphic (long front) installation specifications. 20 Curved corner canopy graphic installation specifications. 21 Pump imaging basics. 22 Pump skirt graphic installation specifications 22-23 Valances. 24 Valance graphic installation specifications. 25 Marketing logos, print and vinyl colors. 26

A TYPICAL SPIRIT STATION SELF SERVE GASOLINE APPROVED VENDORS Per the Spirit brand license agreement, licensees are required to use the approved vendors listed below. PAINT Jones-Blair Paint Company Order placement, shipping, field application, instruction guides, credit applications and technical data sheets Jones-Blair Customer Service (Attn: Elida) (800) 492-9400 Kristal Bluemer National Sales Manager - Imaging (800) 492-9400 Office: (214) 353-1645 Mobile: (214) 676-8542 kbluemer@jones-blair.com HIGHWAY SIGNS Lyle Signs Rhonda Ferguson - Acct Mgr. (701) 252-9494, ext. 2 rhondaferguson@lylesigns.com SIGNS Federal Heath Sign Company Mike St. Onge (813) 855-4415, ext.14 mstonge@federalheath.com CANOPY & PUMP GRAPHICS Mountain Commercial Graphics Stacy Hart (713) 996-6618 stacyh@mountain-cg.com 1

PAINT STANDARDS BUILDINGS: Buildings on Spirit Brand sites shall be painted Spirit Brand White. Exceptions may be made for proprietary-brand convenience stores. All building trim and fascia shall be painted Spirit Brand Blue. SIGN POLES: Sign poles shall be painted Spirit Brand Blue or Spirit Brand White. Spirit signs are available exclusively from Federal Heath Sign Company (p.1). Existing signs may be retrofitted with Spirit sign faces made by Federal Heath, provided the Spirit registered logo is not altered. PMOCO must approve retrofit signs. CURBS & PUMP ISLAND: Shall be painted Black, Medium Gray, or Spirit Brand Blue. BUMPER (CRASH) POLES: Shall be painted Spirit Brand White or Spirit Brand Blue. CANOPY POLES: Shall be painted Spirit Brand White or Spirit Brand Blue. APPLICATION: The Spirit Repainting Field Application Guide (available from Jones-Blair Paint Company) provides guidelines for applying Spirit Brand-specified paint products as well as correct power washing procedures. Please note that paint must cure for seven days post-application before decals may be affixed to pumps, poles, canopies, or other painted surfaces. NOTE: Driveways and parking areas should be smoothly paved and kept clean and free of debris. EXCEPTIONS: Exceptions to any of the above image standards may be granted only by PMOCO. Please submit variance requests in writing to: Spirit Petroleum, P.O. Box 1419, Soap Lake, WA 98851 or by e-mail to gramm@spiritpetroleum.com. Paint Colors and Codes JONES-BLAIR PAINT COMPANY SPIRIT BRAND BLUE - #4550-001/99951 ACRYLITHANE HS3 FADE/CHALK RESISTANT URETHANE SPIRIT BRAND WHITE - #45011-CA/99951 ACRYLITHANE HS3 FADE RESISTANT URETHANE SPIRIT BRAND RED - #45191/99951 ACRYLITHANE HS3 FADE RESISTANT URETHANE BLACK - #45572/99951 MEDIUM GRAY - #45597/99951 Official Spirit Brand paint colors (Spirit Brand Blue, Red, and White) and other specified colors (Black and Medium Gray) are produced exclusively by Jones-Blair Paint Company. Paints are available ready-mixed and must be applied as specified for maximum color and gloss retention. NOTE: The Spirit Minimum Image Standards Guide is intended as a comprehensive guide for any approved use, application, or installation of the Spirit and SpiritMart names, logos, and colors. Licensees are directed to contact PMOCO for approval for any use, application, or installation other than those specified in the manual. Any use, reproduction, or manufacture of the Spirit or SpiritMart names, logos, or colors by unauthorized vendors is illegal and will be prosecuted to the fullest extent of the law. It is the licensee s responsibility to identify and comply with all state and local laws and mandates pertaining to signs and commercial graphics at Spirit and SpiritMart locations. 2

REPLACEMENT SIGNS Existing cabinets may be retrofitted with sign faces made by Federal Heath. Existing sign faces are removed and replaced with new Spirit sign faces. Spirit ID Sign Face Existing cabinets and poles should be painted Spirit Brand White or Blue. Price Sign Face Note: Spirit ID sign and SpiritMart logo sign must be separated by another sign when used together on a sign cluster. C-Store Sign Face Service Message and Readerboard Sign Faces 3

ID SIGN FACES Existing or new cabinets may be fitted with Spirit logo ID sign faces made by Federal Heath. If the standard sign proportions do not fit an existing cabinet configuration, then Federal Heath will select an appropriate sign from the Spirit sign progression shown on the right. The white space around the logo may vary to accommodate slight differences in proportion. standard Note: The Spirit Standard ID Sign Face should be used for all new sign construction and as the first option for retrofit signs. Note: Two or more different ID sign configurations cannot be used at the same location without permission from PMOCO. Spirit sign progression Spirit Standard ID Sign Face horizontal 4

PRICE SIGN FACES Existing or new cabinets may be fitted with Spirit price sign faces made by Federal Heath. Note: Certain states mandate the inclusion of the text Self Serve Gasoline on price sign faces. Individual states may have additional requirements. It is the licensee s responsibility to be aware of and adhere to state requirements when placing sign orders. The examples below show a few of the many price sign face configurations available to fit existing or new cabinets. REGULAR REGULAR PLUS PREMIUM SELF SERVE GASOLINE REGULAR REGULAR PLUS PREMIUM DIESEL SELF SERVE GASOLINE SELF SERVE GASOLINE REGULAR DIESEL CANOPY-MOUNTED LED PRICE SIGNS RETRO-FITTING LED PRICE UNITS Canopy-mounted LED price signs are allowed. Canopy-mounted cabinets must match the color of the canopy fascia where mounted. Replacement faces, retainers, and LED units are typically shipped as a complete assembly. Existing cabinets are required to accept recessed retainers. If the customer intends to reuse existing LED units, a detailed field survey is required to determine the size and position of the clear window opening for the price unit. Licensees are responsible for costs associated with remounting, moving, or adjusting existing LED units as necessary to fit replacement faces. 5

C-STORE SIGN FACES Existing or new cabinets may be fitted with SpiritMart logo sign faces made by Federal Heath. The logo style that best fits the existing cabinet proportions should be used. SpiritMART horizontal style SpiritMART vertical style Note: Spirit ID sign and SpiritMart logo sign must be separated by another sign when used together on a sign cluster (see p. 3). SERVICE MESSAGE AND READERBOARD SIGN FACES Existing or new cabinets may be retrofitted with Spirit service message and readerboard sign faces made by Federal Heath. CAR WASH Service message sign faces will be imaged with the Frutiger Bold font. THREE LINES OF COPY Readerboards can be made in single or multiple lines of copy depending on the size of the cabinet. 6

NEW SIGNS TWIN POLE SIGNS The standard configurations for new Spirit twin pole signs shown below are a few of the many configurations and sizes available. Check local zoning laws for height or clearance limitations before ordering. See pages 4-6 for sign face information. Consult with Federal Heath Sign Company if you require a setup different from the examples shown. All new signs that include a logo ID sign must use the standard Spirit ID sign face as shown below. TP - 7 TP - 8 TP - 5 TP - 6 REGULAR REGULAR PLUS REGULAR PLUS PREMIUM REGULAR PREMIUM DIESEL 30 SELF SERVE GASOLINE 23 ATM THREE LINES OF COPY CAR WASH THREE LINES OF COPY 5-1 6-1 Minimum Clearance? 7-0 8-1 Minimum Clearance? 7

SINGLE POLE SIGNS The standard configurations for new Spirit single pole signs shown below are a few of the many configurations and sizes available. Check local zoning laws for height or clearance limitations before ordering. See pages 4-6 for sign face information. Consult with Federal Heath Sign Company if you require a setup different from the examples shown. All new signs that include a logo ID sign must use the standard Spirit ID sign face as shown below. 10-4 10-4 REG REGULAR PLUS PREM 7-6 6-1 SELF SERVE GASOLINE SELF SERVE GASOLINE CAR WASH ATM 20 CP - 7x10 CP - 6x10 8-1 8-1 6-1 REG PLUS PREM DIESEL 5-10 REG PLUS PREM SELF SERVE GASOLINE 4-7 REGULAR CAR WASH ATM 20 3-6 CP - 5x8 CP - 4x8 CP - 3x6 8

SINGLE POLE ID SIGNS The standard configurations for new Spirit single pole ID signs shown below are a few of the many configurations and sizes available. Check local zoning laws for height or clearance limitations before ordering. See pages 4-6 for sign face information. Consult with Federal Heath Sign Company if you require a setup different from the examples shown. All new signs that include a logo ID sign must use the standard Spirit ID sign as shown below. 7-0 8-6 5-0 6-2 3-7 15-0 25-0 20-0 4-7 SPLO - 60 SPLO - 30 SPLO - 15 9

HIGH RISE ID SIGNS The standard configurations for new Spirit high rise ID signs shown below are a few of the many configurations and sizes available. Check local zoning laws for height or clearance limitations before ordering. See pages 4-6 for sign face information. Consult with Federal Heath Sign Company if you require a setup different from the examples shown. All new signs that include a logo ID sign must use the standard Spirit ID sign as shown below. 13-1 16-0 11-6 60-0 90-0 14-0 HR-160 HR-209 10

MONUMENT SIGNS The standard configurations for new Spirit monument signs shown below are a few of the many configurations and sizes available. Check local zoning laws for height or clearance limitations before ordering. See pages 4-6 for sign face information. Consult with Federal Heath Sign Company if you require a setup different from the examples shown. All new signs that include a logo ID sign must use the standard Spirit ID sign as shown below. 10-4 REG 10-4 PLUS REGULAR PREM SELF SERVE GASOLINE 7-6 6-1 CAR WASH ATM SELF SERVE GASOLINE M - 7x10 M - 6x10 8-1 8-1 CAR WASH REG PLUS PREM DIESEL ATM 5-10 REG PLUS PREM SELF SERVE GASOLINE 4-7 6-1 REGULAR 3-6 M - 5x8 CP - 4x8 CP - 3x6 11

ILLUMINATED CHANNEL LETTER AND TRIM CAP SIGNS Spirit logo signs are available for canopies and other applications. SpiritMart logo signs are available for fascia and other applications. Channel letter signs have LED backlighting; trim cap signs do not. See page 14 for Spirit logo placement on canopies. The sizes shown are approximate. Other sizes are available. Consult with Federal Heath Sign Company if you require a setup different from the examples shown. Note: Illuminated Spirit channel letters must be used in conjunction with canopy-mounted LED price signs unless the site has a pole-mounted sign. Note: White channel letter and trim cap signs should not be used on canopies. Attached to wall or fascia 27 20 5-10 5 1 Side View LED Channel Letters Side View Trim Cap Letters 27 20 10-9 2-11 5-10 Signs also available with white letters for colored backgrounds as shown above. 12

INTERSTATE HIGHWAY SIGN Highway signs are available from Lyle Signs (see p.1) and should be used for interstate highway signage. FLAG SIGNS Flag signs are available from Federal Heath Sign Company (p.1). Decals are available from Mountain Commercial Graphics (see p.1). Install 9-0 above finished grade 13

CANOPIES Fuel island canopies are required for Spirit licensed locations. Exceptions may be granted if there are zoning or permitting issues. Variance requests must be submitted to Spirit in writing. Note: Backlit LED channel letter signs are required on canopies for sites that do not have a backlit ID sign (see p.12). STANDARD CANOPY IMAGE SEGMENTS CANOPY SPECIFICATIONS Canopy poles shall be blue or white. Canopy fascia shall be imaged with approved Spirit graphic materials available from Mountain Commercial Graphics. Spirit logo vinyl letters are available from Mountain Commercial Graphics; Spirit logo channel letters are available from Federal Heath Sign Company. The standard image segments below can be configured to fit almost any size or type of canopy. Questions concerning canopy imaging should be addressed to Gerry Ramm at (509) 203-7357 or gramm@spiritpetroleum.com. 10 or 20 10 varies 10 varies 10 or 20 Red (R) Fixed 10 length Appears on 50 or longer canopies or smaller canopies when the side and end panels add up to 50 or more Two pieces (20 ) are used on canopies 100 long Eagle Logo (EL) over White Blockout (W) Fixed 10 length Must be used over a White Blockout segment or over panels that are painted Spirit White Intense Blue (B) Variable length (Min10 ) May be used to cover additional length of canopy fascia Flag Transition (FT) 10 section Must be used over a White Blockout segment or over panels that are painted Spirit White Spirit Logo (SL) over White Blockout (W) Use 10 of White Blockout (W) for canopies < 100 long. Use 20 for canopies 100. Spirit logo must be placed on White Blockout (W) as shown below. 14

CANOPY GRAPHIC IMAGE SEGMENT APPLICATION BASICS If the eagle logo (EL) and flag transition (FT) image segments are taller than the canopy fascia, center the segments vertically and trim the top and bottom. The Spirit logo (SL), eagle logo ( EL), and flag transition (FT) must be applied over White Blockout or Spirit White paint. VINYL APPLICATION TEMPERATURE (AIR AND SUBSTRATE) Flat without rivets: 40-100 F (4-38 C) Curves or corrugations: 50-100 F (10-38 C) Compound curves: 60-90 F (16-32 C) Center the eagle logo and flag transition equal (EL) equal (FT) Placement of the Spirit logo or LED channel letter sign and flag transition at canopy corner 20 for canopies < 100 long and 30 for canopies 100 long equal Distance from corner width of pi equal Spirit logo should not touch bottom or top edge of canopy. Note: Secure all loose flashing or trim angles on the canopy before applying fascia vinyl. Canopy fascia vinyl must completely cover the canopy fascia. Secure all existing flashing / trim Vinyl must completely cover canopy fascia 15

GRAPHIC INSTALLATION SPECIFICATIONS FOR CANOPIES 40 OR LONGER The layout below shows how to image a canopy 40 long or longer using the standard canopy image segments shown on page 14. Note that the Spirit eagle must be placed on the long sides of a rectangular canopy.* If the canopy is square, then the Spirit eagle should face the major traffic area. A panel of the canopy may be imaged plain white if it is too close to an adjacent structure to be visible. * The Spirit eagle image may not be placed on contiguous sides of any rectangular canopy. Note: Illuminated Spirit channel letters must be used in conjuction with canopy-mounted LED price signs unless the site has a pole-mounted ID sign (see pages 5 and 12). W(10 ), EL B (length varies) FT(10 ) W (10 ), SL W (length varies), SL 40-50 canopies R(10 ) W(10 ), EL B (length varies) FT(10 ) W (10 ), SL W (length varies), SL 50-100 canopies R(10 ) R(10 ) W(10 ), EL B (length varies) FT(10 ) W (20 ), SL W (length varies), SL 100 or longer canopies 16

GRAPHIC INSTALLATION SPECIFICATIONS FOR CANOPIES UNDER 40 The layouts below show how to image a canopy less than 40 long using the standard canopy image segments shown on page 14. If the length + width of the canopy is less than 40, use the all-white procedure below. If the length + width of the canopy is 40 or greater, use the corner-wrap procedure as shown below. The eagle logo (EL) segment should appear on the long sides of a rectangular canopy. Note: Illuminated Spirit channel letters must be used in conjunction with canopy-mounted LED price signs unless the site has a pole-mounted ID sign. (See pages 5 and 12) W (length varies), SL total < 40 W (length varies), SL Canopy (1)length + (1)width < 40 (all white) W(10 ), EL B (length varies) total = 40-50 FT(10 ) W (10 ), SL minimum width = 20 Canopy (1)length + (1)width = 40-50 (corner wrap) G(10 ) W (10 ), SL minimum width = 20 R(10 ) W(10 ), EL B (length varies) total > 50 Canopy (1)length + (1)width > 50 (corner wrap) 17

OPTIONAL GRAPHIC INSTALLATION FOR WIDE CANOPIES The layout below shows an optional image treatment for canopies with wide ends. This treatment uses the standard canopy image segments shown on page 14. Canopy ends must be a mininmum of 30 wide to use this option. The eagle logo (EL) segment should appear on the long sides of a rectangular canopy. Note: Illuminated Spirit channel letters must be used in conjunction with canopy-mounted LED price signs unless the site has a pole-mounted ID sign (see pages 5 and 12). (center flag transition on end) (center flag transition on end) Standard Canopy Side B (length varies) FT W (length varies), SL Optional end for wide (30 or >) canopies 18

STANDARD T-CANOPY GRAPHIC (SHORT FRONT) INSTALLATION SPECIFICATIONS The layouts below show how to image a Short Front (< 50 ) T-canopy using the standard canopy image segments shown on page 14. Questions concerning T-canopy imaging can be addressed to Gerry Ramm at (509) 203-7357 or gramm@spiritpetroleum.com. Note: Illuminated Spirit channel letters must be used in conjunction with canopy-mounted LED price signs unless the site has a pole-mounted ID sign (see pages 5 and 12). Front < 50 W, SL centered Front R(10 ) if x >25 W(10 ), EL B (length varies) FT(10 ) W (10 ), SL W (length varies) center EL in section Right Side W (length varies) R (length varies) W(10 ), EL B (length varies) Left Side center EL in section FT(10 ) W (10 ), SL 19

STANDARD T-CANOPY GRAPHIC (LONG FRONT) INSTALLATION SPECIFICATIONS The layouts below show how to image a Long Front ( 50 ) T-canopy using the standard canopy image segments shown on page 14. Questions concerning T-canopy imaging can be addressed to Gerry Ramm at (509) 203-7357 or gramm@spiritpetroleum.com. Note: Illuminated Spirit channel letters must be used in conjunction with canopy-mounted LED price signs unless the site has a pole-mounted ID sign (see pages 5 and 12). Front 50 Use Standard Side Configurations Front W (10 ), SL W (length varies) R (length varies) W(10 ), EL center EL in section B (length varies) W (length varies) Right Side W (length varies) R (length varies) W(10 ), EL B (length varies) Left Side center EL in section W (length varies) W (10 ), SL 20

STANDARD CURVED-CORNER CANOPY GRAPHIC INSTALLATION SPECIFICATIONS Use the curved corner segment where the eagle logo transitions into a curved corner. The segment should be centered vertically on the center of the fascia and horizontally on the center of the curve. Use the curved corner transition (CC) where the Eagle logo meets a curved corner center of curve 1 overlap equal center of fascia equal trim trim Curved corner (CC) and eagle logo (EL) segments 1 overlap equal (CC) (EL) equal 21

PUMPS Pumps shall be fully imaged (pump skirt and valance) with decals provided by Mountain Commercial Graphics. Exception: Pumps may be pre-imaged by pump manufacturers who contact PMOCO for the appropriate electronic artwork. Currently, Wayne and Gilbarco Veeder-Root offer pre-imaged equipment. PUMP SKIRT The image below shows the minimum and maximum areas available for the eagle graphic. Use the pump skirt installation instructions on page 21 to install the graphics properly. Minimum Exposed Area 18.75" 51.125" 17.00" 24.00" eagle decal overlay 22

PUMP SKIRT GRAPHIC INSTALLATION SPECIFICATIONS Apply red pump skirt overlay. Align the left side of the eagle logo a distance equal to 10% of the total door width from the left edge of the door. If red pump skirt overlay is visible on the top or bottom of the eagle logo s right edge, then align the eagle logo with the top of the door (examples A & B). When red pump skirt overlay is applied on nozzle area, follow above instructions for eagle logo, and field-cut the nozzle panel and nozzle openings (example D). If state law requires an ID logo on a dispenser without a valance, a 3 white Spirit logo can be applied exactly as shown (example E). If red pump skirt overlay is not visible on the top or bottom of the eagle logo s right edge, then align the eagle logo vertically in the door (example C). 19.75" 10% of overall door width 24.00" 10% of overall door width 42.00" 10% of overall door width top aligned 24.00" 20.00" 31.75" B red pump skirt overlay visible C top and bottom aligned A 24.00" 10% of overall door width nozzle openings 24.00" 6 min. D E 3 Spirit logo (white) 2.5 2.5 23

VALANCES Valances are required on all dispensers. Layouts shown are the approved standard image. Any deviation must be approved by Spirit. Side View Opposite Side View Blue End Risers are Spirit Brand Blue or stainless. Risers are Spirit Brand Blue or stainless. VALANCE PRODUCTS Field-fit valance filmover and logo according to the valance graphic installation specifications on the following page. 10.625 x 78, 82 or 94 Valance Filmover 5 Spirit Valance Logo 24

VALANCE GRAPHIC INSTALLATION SPECIFICATIONS MINIMUM IMAGE STANDARDS Field-fit valance filmover and logo according to the dimensions below. Use same layout for opposite side. Note: Valances taller than 10.625 must be painted Spirit Brand White or a custom filmover must be ordered from Mountain Commercial Graphics. EQ. 5 EQ. 10.625 max. valance filmover (10.625 max) or Spirit Brand White painted valance locate Spirit valance logo 6 from right end on both sides of valance 6" EQ. 5 EQ. 2" side end locate Spirit valance logo 2 from curved end to straight side transition on both sides of valance VALANCE PLANS 6" 2" 6" 2" 25

MARKETING LOGOS Spirit and SpiritMart logos are used for signage and marketing. The following logos are the established standards. They are not to be changed or modified in any way. Contact PMOCO with any questions. Spirit and SpiritMart logos are available for marketing use. Contact PMOCO to obtain the proper digital files. Contact PMOCO for information about specific marketing materials. STANDARD This logo should be used for all marketing and printing purposes. SPIRITMART STANDARD This logo should be used as the first option for SpiritMart advertising. SPIRITMART VERTICAL This logo should be used as the second option for SpiritMart advertising. COLORS The specified Pantone ink mixtures should be used only on printed materials for marketing purposes. 3M180C-13 Tomato Red PANTONE RED 032 or PANTONE RED 032 Process 3M180C-47 Intense Blue PANTONE 2935 or PANTONE 2935 process 3M180C-10 White 26

Spirit Petroleum P.O. Box 1419 Soap Lake, WA 98851 Phone: (509) 203-7357 info@spiritpetroleum.com www.spiritpetroleum.com Revision: 12/16