WATER MAZE POOL HEATER

Similar documents
VARIABLE RATE INFUSION PUMP

SINGLE SPEED SYRINGE PUMP

PULSE OXIMETER PACKAGE

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Installation Instructions

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

Smart Temp. Model

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

TC-NHP01-A, TC-NAC01-A Comfort Series Non- Programmable Thermostat. Owner s Manual

Model: Touch-RS. 1 Touch-RS

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

Ozonated Water System

Refrigerated air dryers

Installation and user manual

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

Wireless Thermostat (WTS10) Keypad Operation Guide

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

5+2 Day. up to HEAT COOL

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Disclaimer. Trademarks. Copyright. Warranty

Installation Settings Guide

7-Day. Digital Thermostat. residential. & 2-cool

1 For All Programmable Digital Thermostat

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

Owner s Manual. Part Number 33CSCPACHP-01

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

GETTING STARTED WITH SMART THERMOSTAT

Legacy Non-Programmable Owner s Manual

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

AE500 Instruction Manual

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

CommStat 4 Controller

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Product Manual SZ1145

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Owner s Manual MODELS 8535, 8536 & 8537

TEMPERATURE CONTROLLER (STANDARD MODEL)

XFlat Blade. Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL. CoolingOnly,Heat Cool,and Heat Pump MULTI-STAGE SEVEN DAY PROGRAMMABLE

Emerson Blue Easy Set 1H/1C

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

SAS803WHL-7 Thermostat for floor heating

OPERATING INSTRUCTIONS

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

TC515 and TC600 Installation Manual. a Winters company

Product Manual SZ1144

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

HPLC Column Ovens and Temperature Controllers

Series Temperature Controller Instruction Sheet

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

ECS 3M USER S MANUAL. Page 1

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

- Data Brochure Universal Reset Module 422

User s Manual

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

USER S INFORMATION MANUAL

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

ELECTRONIC THERMOSTAT

XWA11V. Walk-In Temp / Door /Alarm / Light Module

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

ECS-2M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

C2 Compact Range Installation & Programming Manual

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

Safety & Installation Instructions

Model: Edge-HC. 1 edge-hc

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Homeowner s Guide / 1

CHV-TSTAT-FCU Heating and Cooling Fan-Coil Thermostat. Supplemental Guide Crestron Electronics, Inc.

Operator: Save these instructions for future use!

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Model: Available in: Sapphire Black and Glacier White. 1 Series

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

ETO 2 - Controller for ice and snow melting

Installation, Start-Up, and Operating Instructions

Model: Slimline-B. Battery Series

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Settings and Maintenance of the CombinAir

Eswa DC-1. Thermostat for Floor Heating

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

- Data Brochure Universal Reset Module 423

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes

Installation, Start-Up, and Operating Instructions

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

Instruction manual APU Hard alarm output contacts

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Installation Guide. Twin Kit 086L1370

Transcription:

instrumentation and software for research WATER MAZE POOL HEATER ENV-597 USER S MANUAL DOC-213 Rev. 1.2 Copyright 2013 All Rights Reserved Med Associates Inc. P.O. Box 319 St. Albans, Vermont 05478 Phone: 802.527.2343 Fax: 802.527.5095 www.med-associates.com

notes - i -

Table of Contents Chapter 1 Introduction... 1 Warnings... 1 Chapter 2 thermostat settings... 2 Setting the Temperature... 2 Changing to F... 2 Changing to C... 3 Appendix A Factory Settings... 4 Appendix B Contact Information... 4 - ii -

CHAPTER 1 INTRODUCTION The ENV-597 Water Maze Pool Heater is intended to be used to maintain a constant temperature in either the mouse- or rat-sized pools. The heater will arrive installed in the water maze pool configured for C display. The user will set their desired pool temperature. This manual should be carefully read prior to operating the heater. Figure 1.1 Water Maze Pool Heater Warnings Note: Failure to comply with the following actions will result in heater failure and possible equipment damage, injury or fire. 1. Place the heater controller in a dry location. Moisture in the controller will cause failure. 2. Do not operate the heater when it is out of the water or in low water. An exposed heater is a potential fire hazard. 3. Allow the heater to cool for 20 minutes before removing it from the pool. 4. Protect the heater from power surges by having the properly sized circuit breaker or inline fuse. See label on heater controller. 5. Be sure the thermostat sensor is immersed in water and positioned away from the heater element. - 1 -

CHAPTER 2 THERMOSTAT SETTINGS Setting the Temperature In order to set the temperature, or make other settings changes, remove the four Phillips screws from the corners of the clear protective cover to gain access to the keypad. Be sure your work area is clean and dry before removing the cover. The upper red display labeled PV (present value) is the current temperature of the water. The lower green display labeled SV (set value) is your desired temperature. To adjust the SV (set value): 1.) Press and release the SET button once, the display will now illuminate all four digits of the green SV display. The ones digit will be highlighted and active. 2.) Press the ^ or keys to increase or decrease the temperature in increments of 1 C. 3.) Press the <r/s key and use the ^ or keys to increase or decrease the temperature in increments of 10 C. 4.) Repeat step 3 if you need to adjust the hundreds digit value. 5.) Press and release the SET key to exit 6.) Replace the clear protective cover Changing to F In order to change the temperature display to F: 1.) Press and hold the SET button until the top red display reads Aru. 2.) Press and release the SET button three times until the top red display reads LCK. The bottom green display should read 0011 indicating the settings menu is locked. 3.) Use the <r/s and ^ and keys to change the LCK value to 1000 and then press the SET key. The settings menu is now unlocked and changes can be made. 4.) Press and hold the SET key to exit this menu. 5.) Press and hold the SET and <r/s keys simultaneously until the top red display reads Cod. 6.) Press the SET key two times until the top red display reads SL2 7.) Use the <r/s and ^ and keys to adjust the value of SL2 to 0001 8.) Press the SET key 9.) Press and hold SET and <r/s simultaneously to exit the Cod menu 10.) Repeat steps 1-4 to change the LCK value back to 0011 to prevent unwanted settings changes 11.) Replace the clear protective cover - 2 -

Changing to C In order to change the temperature display to C: 1.) Press and hold the SET button until the top red display reads Aru. 2.) Press and release the SET button three times until the top red display reads LCK. The bottom green display should read 0011 indicating the settings menu is locked. 3.) Use the <r/s and ^ and keys to change the LCK value to 1000 and then press the SET key. The settings menu is now unlocked and changes can be made. 4.) Press and hold the SET key to exit this menu. 5.) Press and hold the SET and <r/s keys simultaneously until the top red display reads Cod. 6.) Press the SET key two times until the top red display reads SL2 7.) Use the <r/s and ^ and keys to adjust the value of SL2 to 0010 8.) Press the SET key 9.) Press and hold SET and <r/s simultaneously to exit the Cod menu 10.) Repeat steps 1-4 to change the LCK value back to 0011 to prevent unwanted settings changes 11.) Replace the clear protective cover - 3 -

APPENDIX A FACTORY SETTINGS The menu settings should be as follows: SL1 = 0001 - Thermocouple type J (indicated on power up, default) SL2 = 0010 - Degrees Celsius (indicated on power up, default). 0001 = Fahrenheit SL3 = 0000 Not used SL4 = 0000 Not used SL5 = 0000 Not used SL6 = 0001 Heat on (default). 0000 = Heat off. SL7 = 0000 Not used SL8 = 0000 Not used SL9 = 0000 Not used Aru = 0 P = 0 Pb = 0 LCK = 0011 Settings locked (default). 1000 = Unlocked APPENDIX B CONTACT INFORMATION Please contact for information regarding any of our products. Visit our website at www.med-associates.com for contact information. For technical questions, email support@med-associates.com. - 4 -