Sound Light & Entry Sensor (RMA-SLE-SEN) Installation Note

Similar documents
Flood Sensor - Cable. Power Port. Front

Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

AVTECH. Digital Active Power Sensor. Installation Note

Room Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Room Alert. Room Alert 32E, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Ion Gateway Cellular Gateway and Wireless Sensors

Protect Your Facility...

Protect Your Facility...

Skipper's Mate. Sensor Testing. Version December Table of Contents

Syringe Pump. User Manual

Protect Your Facility...

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

GETTING STARTED WITH SMART THERMOSTAT

Introduction. OM-THA2

THX-DL Data Logger USER & INSTALLATION MANUAL V

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Advisor Advanced Mobile Application User Manual

CompleteView SightLogix Sensor Setup Manual. CompleteView Version 4.7.1

User s Manual for ZKIR3 Series IR Day & Night

Installing ProSeries 2005

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Alarm Manager Plug-in

Advantium 16 System Monitor

USER S GUIDE. AXIS Cross Line Detection

FortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B

INSTALLATION AND OPERATION MANUAL

Water Hero P-100. P-100 Components:

Getting started with

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Q3200 Smart Home Alarm. Kit Content and Installation Guide

MILAN VORTEX WIRELESS MOTION SENSOR USER MANUAL

Avigilon Control Center 5 System Integration Guide

Getting Started Guide

Patriot Systems Limited

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Tachometer/Hourmeter/Trip. Installation and Operation Manual

Glass Break Sensor. Set-Up Guide

DIGITAL TEMPERATURE RELAY TR-100

TV2 Clean Room Monitor

TV2 Room Pressure Monitor Quick Start Guide

Installing ProSeries 2004

Salusfin Smart heating control: Installation Guide

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

WeatherLink for Alarm Output Addendum

Simplex Panel Interface Guide

Installation and Operation Manual

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

MultiSite Manager. Setup Guide

Proliphix. Remote Management. User Guide

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

the Comprehensive Control Solution

Digijock Home Security

Installation manual Anna. In combination with the Smile T. Manual PW version 2.0

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

Door/Window Sensor. Set-Up Guide

Dry Contact Probe DCP (#30008)

Watchguard WGAP864 User Manual

WiFi GSM APP Smart Home Security System

GLOBAL. InstallatIon & operation manual

Daikin ENVi Thermostat installation overview

Patriot Systems Limited

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0

DAP III Zone Master User s Guide

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Follett Performance Plus

EXC-450 User s Manual

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

Passionate People. Proven Solutions. Messaging and Alarm Monitoring Software

General Routing Interface

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

C - B u s C - T o u c h U s e r s G u i d e C T Series

Tutorial: How to Download and Install Lumberyard v or greater

Alarm System SECURE AS 302

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Manage Alarms. Before You Begin CHAPTER

it500 Internet Thermostat INSTALLER MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER

Square D Clipsal Outdoor Light-Level Sensor

Paxton Access Ltd is a leading manufacturer of electronic access control systems.

HOBO U14 Data Logger User Manual

Wireless D.I.Y. Alarm Kit

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

HEGA Ethernet Gateway Browser Interface Guide

M800, M800iD Plus, M1000 and M3000. User's Guide

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

NO. YG03 INSTALLATION/OPERATION INSTRUCTIONS

Section 8 System Operation

Sensor Control Panel

Manage Alarms. Before You Begin CHAPTER

Get Stoked. Stoker Users Manual Ver 2.0 Software. Get Stoked 1 Rock s Bar-B-Que

Integration Test Plan

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Whats in the box. NS1002-E Installation Guide Rev 1.0

Avigilon Control Center System Integration Guide

Transcription:

Installation Note AVTECH s Sound Light & Entry Sensor (SLE) effectively monitors unstaffed or low-traffic areas: while its built-in sensors detect the occurrence of sound and light in a room, its attached magnet/proximity switch detects the open/closed status of entry points like doors and windows. A convenient general alarm feature allows you to choose whether to configure just one alert if any of those conditions occur, or to alert separately for each. SLE Package Contents One (1) Sound Light & Entry Sensor One (1) magnet & proximity switch pair One (1) 25' speaker wire cable Two (2) mounting screws One (1) Installation Note (You re reading it now.) SLE Features Switch Sensor Output Ports (Front) Each switch port on the front of the SLE corresponds to a different feature of the sensor. The features and normal/alarm states are shown below. 1 General Alarm Front 2 3 4 Sound Light Entry # Feature The normal state, OPEN, means The alarm state, CLOSED, means 1 General Alarm All other ports are open At least one other port is closed 2 Sound No sound is detected Sound is detected 3 Light No light is detected Light is detected 4 Entry No entry is detected (magnet & proximity switch are together) Entry is detected (magnet & proximity switch are apart) If you wish to configure individual alerts for each condition, you may connect output ports 2 through 4 to Room Alert separately; if you d like just 1 alert for any condition, you may simply connect the General Alarm output port. Please see the installation section later in this note for instructions. AVTECH Software, Inc. Temperature & Environment Monitoring Made Easy! AVTECH.com

Sound & Light Sensors (Back) The sound and light sensors, located at the back of the SLE, have corresponding calibration screws located above them at the top of the unit. You may adjust how much sound and light it takes to trigger the sensors by turning the screws: Sound Sensor Back Light Sensor Tighten the screw clockwise to decrease the sensitivity. Loosen the screw counter-clockwise to increase the sensitivity. Calibration Screw Calibration Screw Once you have finished installing and configuring your SLE in Room Alert, test the sound and light sensors to ensure they trigger at the exposure you expect. Room Entry Sensor (Right) Proximity Switch 1 2 Magnet AVTECH s Room Entry Sensor, comprised of a magnet and proximity switch, comes with its leads pre-attached to the SLE s Room Entry Input Port. The Room Entry Sensor is available as a separate product (RMA-RE1-SEN) and can also connect directly to a switch port on any Room Alert model. Right Room Entry Sensor Input Port Leads Please see the Room Entry Sensor Installation Note for mounting instructions. Install Your SLE Do not use this sensor in hazardous (classified) locations or life/safety applications. Step 1: Connect your SLE ID box to Room Alert. Your Sound Light & Entry Sensor comes with one 25' speaker cable pre-attached to the General Alarm (#1) output port. Please contact your Product Specialist if you need more speaker cable for the other switch ports. 1. Separate and strip the free ends of the speaker cable. Expose about ¼" of wire. AVTECH Software, Inc. Page 2 of 5 AVTECH.com

2. Connect the free end of the speaker wire to an open switch sensor port on your Room Alert. The SLE s output ports are non-polarized, so you may insert either side of the wire into either contact. 3. If you would like to configure individual alarms for each condition, repeat the steps above for the Sound (#2), Light (#3) and Entry (#4) output ports. Do not connect the dry contacts on AVTECH products or other electrical appliances to live circuits. Use only low-voltage 2-wire cable to connect dry contacts. Step 2: Mount the components. SLE ID Box Position the SLE so that the sound and light sensors are not blocked; you may wish to face the back of the SLE upwards for this reason. You may mount the SLE on a vertical surface with the included screws through the flange holes. Room Entry Sensor Please see the Room Entry Sensor Installation Note for instructions on mounting the magnet and proximity sensor. Step 3: Connect your SLE ID box to a power source. Your SLE comes with AVTECH s International Power Adapter. Left 1. First connect AVTECH s International Power Adapter to the power port on the SLE. 2. Then plug it into a power source. Note that the LED illuminates when power is on. Power LED Power Port Use only AVTECH s International Power Adapter with AVTECH monitors and sensors; others could damage your product and will void the warranty. AVTECH Software, Inc. Page 3 of 5 AVTECH.com

Configure Your SLE With Room Alert s Built-In Web Interface Navigate to Settings Sensors in your Room Alert web interface. The options you see below will vary depending on the model. 1. Scroll down to Switch Sensor Settings. 2. Find the label that matches the Room Alert port you connected your SLE output port to. For example, if you used the first switch sensor port on your Room Alert, look for Sensor 1 Label ; if you used the second, look for Sensor 2 Label, and so on. 3. In Sensor X Label, you may leave the default name or enter something more descriptive, such as SLE Gen Rm 10 or Server 3 Light 4. In Alarm On, choose Closed. The normal state of the General Alarm, Sound, Light and Entry switch sensors on the SLE is Open. 5. For models with the Use Alarm Profile feature: if you have configured Alarm Profiles in the Alarm Options screen, you may choose a profile from the drop-down menu. The default is Profile 1. 6. Click Accept Changes at the bottom of your screen to temporarily save your settings. You may now navigate to another screen; however, if you close the web interface before the final step, you will lose your changes. 7. Click Save Settings in the navigation bar to the left of your screen. Your Room Alert will automatically reboot and commit your changes. AVTECH Software, Inc. Page 4 of 5 AVTECH.com

With AVTECH s Device ManageR Software For Advanced Functionality For advanced functionality and easy management of multiple units, configure your sensor with AVTECH s Device ManageR, the software that comes FREE with the purchase of any Room Alert monitor. You may download the current version from your customer account at AVTECH.com/Downloads while your Maintenance, Support & Update Service (MSUS) is current. If your service and access has lapsed, please contact your Product Specialist about reactivating them. Sound Light Entry Sensor Features & Specifications Environment Condition Monitored... Sound, light and entry Type Of Sensor... Switch Normal State... Open (No sound, light, entry detected) Power Supply... AVTECH s 1A 5VDC International Power Adapter Included... Yes Sensor Cable Type... Low-voltage, 2-wire speaker cable Included... Yes Length... 25' Maximum Extendible Length... 900' Compatible Products... Any Room Alert or Wireless Sensor Hub model AVT-140502.02 AVTECH Software, Inc. Page 5 of 5 AVTECH.com