WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Similar documents
Warranty Registration

Warranty Registration

Warranty Registration

VA301C CONTROLLER WITH BACnet OPTION

Two-Channel Gas Controller

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SIL 2. Ultima X Series Gas Monitors CERTIFIED

EXAMPLES OF HOW TO ORDER

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

EXAMPLES OF HOW TO ORDER

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Oxygen (O2) Single-Point Gas Detection System

Toxic Gas Detection. Model F12. Toxic Gas Detection

Carbon Monoxide Transmitter

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Macurco DVP-120 Detection and Ventilation Control Panel

INSTALLATION AND OPERATING INSTRUCTIONS

Inc Series Digital Gas Detector/Controller. Operation Manual

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Combustible Gas Detection and Control System

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

Sieger Apex. Flexibility that meets your requirements

Universal Gas Detector

Model D12-IR. Digital Gas Transmitter...

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

GLD-30 Gas Leak Detector

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Controllers. Instruction Manual WARNING

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

Model D12. Digital Gas Transmitter

OLC(T) 100 FIXED GAS DETECTOR

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

Mark 25 Ultrapure Water Conductivity Analyzer

Gas Detection System TOX ALARM DG2000-Garage

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

incontrol Systems Inc. Flame and Gas Detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Instruction Manual WARNING

Universal Transmitter. Operations & Maintenance Manual

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

ALTAIR 5X Multigas Detector Product Specification

3M Oldham OLCT 100. Description. Fixed Gas Detector

IGD.CO.UK

IMR IX176 Portable Gas Detector User Manual

GL-CO-RFG Channel Gas Leak Alarm System

Stand Alone DYNAGARD SP Operation Manual

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

PureAire Combo O 2 / CO 2 Monitor

SEC 2000 Millenium Infrared Gas Detector

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

PointGard II. Operating Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Frequently Asked Questions

GAS MONITOR Model Model

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

User and Installation manual

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

Air Check O 2 Deficiency Monitor 0-25%

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

! "! # Please read these installation and operating instructions completely and carefully before starting.

RAM3 Remote Alarm Module

Danfoss gas detection units

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

CMF, CMX & CMA series

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Macurco HD-11 Hydrogen Gas Detector

Analog Room Pressure Monitor RPC Series

21-light Remote Annunciator. Owner s Manual

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

GAS PLUS ALARM SYSTEM

Dependable Solutions for Gas Detection

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Pioneer-R16 Gas Monitor Operator s Manual

QD6310. Fixed Gas Detector Operation Manual

Air Check O 2 Sample Draw Monitor

M3050 Detector Operator s Manual

Danfoss gas detection unit Type GD Heavy Duty

Transcription:

A d e v i h c r D c o n e m u

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from the date of purchase. Vulcain will, without any charge and at its option, repair or replace defective products or components upon their delivery to its Repair and Service Department. This warranty does not apply in the event of misuse or abuse of the product, or as a result of unauthorized alterations or repairs. Vulcain shall not be liable for any consequential damages, including, without limitation, damages resulting from loss of use. Every precaution for accuracy has been taken in the preparation of this manual. However, Vulcain neither assumes responsibility for any omissions or errors that may appear, nor liability for any damages that may result from the use of the products in accordance with the information contained in this manual. To obtain warranty service, return the product, along with a complete description of the defect, transportation prepaid. Vulcain assumes no risk for damage in transit. Following warranty repair, the product will be returned to the buyer, transportation prepaid. Warranty Registration Technical Support Line: 1-800-563-2967 Before returning a product for warranty service, please contact Vulcain s Technical Support Department. To validate the warranty, this registration form must be completed in full and sent to Vulcain within 90 days of the date of purchase. Fax it to Vulcain at (450) 619-2525. Customer s name: Address: City: State/Province: Location of the installation: Serial No.: BEFORE RETURNING ANY INSTRUMENTS, PLEASE CONTACT US TO OBTAIN A RETURN OF MATERIAL AUTHORIZATION NUMBER. Vulcain Alarm Inc. All rights reserved 1 DR0009 February 2004

TABLE OF CONTENTS WARRANT Y...1 UNPACKING...3 DESCRIPTION...3 INSTALLATION GUIDELINES...3 DETERMINATION OF THE NUMBER OF TRANSMITTERS...4 VA201C CONTROLLER...5 USER INTERFACE...5 SPECIFICATIONS...6 PERIODIC INSPECTIONS AND CALIBRATION...6 ELECTRICAL WIRING...7 VA301IRF...9 USER INTERFACE...9 SPECIFICATIONS...9 ELECTRICAL WIRING - VA301IRF...10 VA201TQ1/Q2...11 USER INTERFACE...11 SPECIFICATIONS...12 ELECTRICAL WIRING - VA201TQ1/Q2...13 VA301D 2...14 USER INTERFACE...14 SPECIFICATIONS...15 ELECTRICAL WIRING - VA301D 2...16 90DM 3 R...17 USER INTERFACE...17 SPECIFICATIONS...17 ELECTRICAL WIRING - 90DM 3 R...18 VASQNA...19 USER INTERFACE...19 SPECIFICATIONS...19 ELECTRICAL WIRING - VASQNA...20 VA420I...21 SPECIFICATIONS...21 ELECTRICAL WIRING - VA420I...22 VA201R...23 SPECIFICATIONS...23 ELECTRICAL WIRING - VA201R...24 VASQN8X...25 USER INTERFACE...25 SPECIFICATIONS...26 ELECTRICAL WIRING...27 SURFACE-MOUNT INSTALLATION...28 RANGE AND ALARM LEVELS...30 PCT-1T X SINGLE-POINT SAMPLE-DRAW ALL-WEATHER HOUSING...31 DETECTION PARAMETERS...32 DR0009 February 2004 2 Vulcain Alarm Inc. All rights reserved

UNPACKING After opening the package and removing the equipment and components, make sure that you have all the items described on the order form or packing slip. DESCRIPTION The VA201 System sets new standards in gas detection and in the measurement of environmental parameters. The VA201C System is a complete control system composed of a VA201C network controller and any of the following units: a VA201T, VA301D 2, 90DM 3 R gas analyser/transmitter, VA201R relay module(s), VASQNA annunciator panel, VA420I converter, and/or the VASQN8X multi-point sample draw gas monitor. INSTALLATION GUIDELINES Make sure to locate the monitor and sensing assemblies in an area easily accessible to a technician. Avoid any location where the monitor could be subject to vibrations. Avoid any location close to equipment emitting electromagnetic interference. Avoid any location where temperature changes occur rapidly. Verify all the requirements and existing regulations which may affect the choice of location. Select a location at the perimeter of the chiller, boiler, cooler or any other equipment that may leak. Airflow patterns must also be considered. Conduit installation must conform to local fire, building and electrical codes. For the DT Duct-Type housing, installation is recommended on a straight duct at least 3 feet (1 m) away from any curve. A cable with more than 1 pair of wires is unacceptable for communication use. Vulcain Alarm Inc. All rights reserved 3 DR0009 February 2004

DETERMINATION OF THE NUMBER OF TRANSMITTERS The number of transmitters is determined by a unit s radius of surveillance. Using Table 1 below, the number of units can be easily evaluated. CO NO 2 TABLE 1 Radius of surveillance Gas Detected Radius of Surveillance Area Covered Carbon Monoxide Nitrogen Dioxide 50 feet (15 metres) 7,854 square feet (707 m 2 ) Others 23 feet (7 metres) 1,662 square feet (154 m 2 ) DR0009 February 2004 4 Vulcain Alarm Inc. All rights reserved

VA201C CONTROLLER USER INTERFACE Green LED: Power ON Red LED A and B: Indicate that one or more transmitters have reached their first (Level A) or second (Level B) alarm level. Yellow LED: Fault Display: On the first line, the first three letters indicate the status of the operation. Nor: normal or Alr: high gas concentration alarm or fault. On the same line is the transmitter address and the last 8 characters indicating the gas detected or transmitter location. Second Line Concentration read and unit of measurement Audible Alarm Silence Key KeyPad: Numbers 0-9 are used to enter the Programming Menu password. The left and right arrow keys are used to move to any of the two lines on the display. The up and down arrow keys are used to browse through the programming fields and to modify any values in a specific field. The magnifying glass is to enter or exit the Programming Menu. Each transmitter is scanned at intervals of 10 seconds. Priority of the display is given to the Alarm and Fault conditions. Up and down arrow keys allow for manual scanning of each zone. Vulcain Alarm Inc. All rights reserved 5 DR0009 February 2004

SPECIFICATIONS VA201C Power Requirements: 17-27 Vac, 24-38 Vdc, 250 ma Operating Temperature Range: Operating Humidity Range: Network Capacity: User Interface: 32 F to 100 F (0 to 40 C) 0 to 95% RH, (non-condensing) Up to 32 transmitters, 16 per channel Optional alphanumeric display and keypad Visual Indicators: Power On Green LED Alarm Level 1 Red LED Alarm Level 2 Red LED Failure Yellow LED Audible Alarm: Outputs: Time Delays: 65dBA at 3 feet (1 metre) 3 DPDT relays 5A, 30 Vdc or 250 Vac (resistive load) Maximum Distance Between the Controller and the Last Transmitter: 2,000 feet (600 m) Dimensions: Weight: 0 to 99 minutes before and after an alarm 8.5 in(h) x 11.0 in( W)x 2.0 in(d) (22.2 cm x 26.1 cm x 5 cm) 3.5 lbs (1.58 Kg) PERIODIC INSPECTIONS AND CALIBRATION This unit requires calibration. The calibration frequency will be a function of the operating conditions, including operating under extreme temperatures, exposure to contaminants or gas concentrations greater than the lower explosive limits. A calibration inspection must be included as part of a routine maintenance to ensure proper operation of the gas detection unit. If unit span or zero cannot be adjusted, the sensor may be approaching its end-of-life or has been contaminated and must be replaced. DR0009 February 2004 6 Vulcain Alarm Inc. All rights reserved

ELECTRICAL WIRING Output RS-232c: J5 (option) to serial printer. Power: J1 17 to 27 Vac, 24 to 38 Vdc, 250 ma. Audible Alarm Output: J2 30 ma, 12 Vdc. Power Source (Vac), Communication (A-B): J3 channel 1 et J4 channel 2. See details in tables 2, 3 and 4. Relay Output: Relay 1: J6, Relay 2: J7, Relay 3: J8, 5 A, 30 Vdc or 250 Vac (resistive load) The electrical wire gauge is defined with respect to the network length and type of units involved. VA201TQ1 except Q1 Combustibles (Comb.) and Refrigerants (Ref.) TABLE 2 Electrical Wire Gauge Length of Network Total Number of Units per Channel per Channel 4 8 12 16 1,000 feet (300 m) 18 AWG 18 AWG 16 AWG 16 AWG 1,500 feet (450 m) 18 AWG 16 AWG 16 AWG 14 AWG 2,000 feet (600 m) 18 AWG 16 AWG 14 AWG 14 AWG Vulcain Alarm Inc. All rights reserved 7 DR0009 February 2004

VA301D 2, VA201TQ2, VASQNA, 90DM 3 R, VA301IRF and VA201TQ1-Exp. TABLE 3 Electrical Wire Gauge Length of Network Total Number of Units per Channel per Channel 4 8 12 16 750 feet (225 m) 18 AWG 18 AWG 16 AWG 14 AWG 1,000 feet (300 m) 18 AWG 16 AWG 14 AWG 14 AWG 1,500 feet (450 m) 16 AWG 16 AWG 14 AWG ** 2,000 feet (600 m) 14 AWG 14 AWG ** ** ** Local power source must be used for these applications. WARNING A VA201R Relay Module will increase the total number of units per channel by 1 unit for every 2 relays. Consequently, a VA201R-8 Relay Module will increase the total number of units per channel by 4. A VA420I Module will increase the total number of units per channel by 2. The network communication wire gauge depends on the distance between the controller and the last transmitter on each communication channel. For each channel, one distinct shielded twisted pair is needed with 6 twists per foot. Network Length per Channel TABLE 4 Communication Wire Gauge Communication Wire Gauge Less than 2,000 feet (600 m) 24 AWG (Belden 9841) WARNING The communication cable must be independent from the electrical cable. A multi conductor cable is not acceptable. DR0009 February 2004 8 Vulcain Alarm Inc. All rights reserved

VA301IRF USER INTERFACE SPECIFICATIONS Gases detected : Sensing technology: Measurement range: Resolution: Response time: Cold to start: Optional outputs: Optional audible alarm: Display : Visual indicators: Relay Output Rating: Power requirement: Operating Temperature Range: Operating Humidity Range: Enclosure: Size: Weight: R-11, R-12, R-22, R-123, R-125 and R-134a (other mixes also available) Vulcain dual infrared sensor 0-1000 ppm 1 ppm 60 seconds 10 minutes 4-20 ma 3 DPDT relays RS-485 65 dba @ 3 ft. Backlit LCD Green LED: Normal operation Red LEDs: Alarms A, B and C Yellow LED: Fault Yellow LED: Tx (activated in network mode) 5A, 30Vdc or 250Vac (resistive load) 17-27 Vac, 24-38Vdc, 600mA@24Vdc 32 F to 100 F (0 to 40 C) 0 to 95% RH (non-condensing) ABS - Polycarbonate Transmitter 7.99 (H) x 11.02 ( W) x 2.76 (D) Sensor 4.02 (H) x 11.02 ( W) x 2.48 (D) Transmitter 2.26 lbs (1.02 kg) Sensor 2.33 lbs (0.603 kg) Vulcain Alarm Inc. All rights reserved 9 DR0009 February 2004

ELECTRICAL WIRING - VA301IRF Power: 4-20 ma End of line: JP3 Relay Output: Input J1 Output: J5 To determine a transmitter J6, J7, J8 and output J2 See details in section to be the last in the network, 5 A, 30 Vdc 17 to 27 Vac, 4-20 ma LOOP place the jumper in an upright or 250 Vac 24 to 38 Vdc, CONFIGURATION position aligned at the top. (resistive load) 600 ma Transmitter Twisted and shielded cable #24AWG max. 100 feet (30 m). Sensor Communication: Input J10 and output J11. Vulbus protocol: Up to 16 transmitters per bus. The maximum distance between the controller and the furthest transmitter is 2 000 feet. Modbus protocol: Up to 128 transmitters per bus. The maximum distance between the controller and the furthest transmitter is 4 000 feet. DR0009 February 2004 10 Vulcain Alarm Inc. All rights reserved

VA201TQ1/Q2 USER INTERFACE The 10 red LEDs indicate the gas concentration detected. Each red LED represents 10% of the reading scale. For example, an oxygen depletion transmitter with a 21% reading will have 8 red LEDs lit. When Powering ON, the green LED lights to indicate power ON. Vulcain Alarm Inc. All rights reserved 11 DR0009 February 2004

SPECIFICATIONS Power Requirements: 17-27 Vac, 24-38 Vdc, 250 ma Operating Temperature Range: Operating Humidity Range: Outputs: 32 F to 100 F (0 to 40 C) 0 to 95% RH, (non-condensing) 1 DPDT optional relay 5A, 30 Vdc or 250 Vac (resistive load) 4-20 ma (optional) Maximum Distance Between the Controller and the Transmitter: 2,000 feet (600 m) Dimensions: 8.4 in(h) x 5.3 in( W) x 2.25 in(d) (21.3 cm x 13.4 cm x 5.7 cm ) DR0009 February 2004 12 Vulcain Alarm Inc. All rights reserved

ELECTRICAL WIRING - VA201TQ1/Q2 Relay Output: J1 (optional) 5 A, 30 Vdc or 250 Vac (resistive load) 4-20 ma Output: J2 (optional) Power and Communication: J3 Fed by the VA201C controller. If the 4-20mA output is present and configurated in active mode, a local power supply is required: 17-27 Vac, 24-38 Vdc, 250 ma Vulcain Alarm Inc. All rights reserved 13 DR0009 February 2004

VA301D 2 USER INTERFACE Menu key Scroll key Visual Indicators I/O (green LED) : Normal ALA (red LED) : Alarm ALB (red LED) : Alarm or fault (option) Tx : Communication F1 (yellow LED) : Sensor fault LCD Display Scroll key DR0009 February 2004 14 Vulcain Alarm Inc. All rights reserved

SPECIFICATIONS Power Requirements: 15-27 Vac, 18-38 Vdc, 380 ma @ 24 Vdc Operating Temperature Range: -40 F to 100 F (-40 C to 40 C) Toxic gases -40 F to 112 F (-40 C to 50 C) Combustible gases Operating Humidity Range: 0% to 95% RH Non-condensed Sensing Technologies: Q1: electrochemical (toxic) catalytic combustion (combustibles) diffusion fuel cell (oxygen) Display: Alpha numeric LCD display with backlit Visual Indicators: Green LED: Normal operation Red LED: Alarm A Red LED: Alarm B Green LED: Communication Yellow LED: Fault Outputs: 4-20 ma, 2 optional SPDT fail safe relays Maximum Length of Lines: 2,000 feet (600 m) for Vulbus 4,000 feet (1,200 m) for Modbus Minimum size Conductors: See wiring requirements section Relay Output Rating: N.O.: 2a 250 Vac, 5A 125 Vca, 3A 30 Vdc N.C.: 1A 250 Vac, 2A 125 Vac, 1A 30Vdc Storage Temperature: -40 F to 112 F (-40 C to 50 C) Pressure Limits: 800 to 1200 millibars Communication: RS-485 two wires Communication Protocol: Autodetect Vulbus or Modbus Transmission Speed: 9.6 kbauds (also available: 0.3, 2.4, 19,2) Eight-bit Frame: 1 start bit, 7 bits of data, 2 stop bits, no parity 8 status bits available Enclosure: Class 1, Division 1, Groups B, C, D Dimensions: 7.5 in. (H) X 6.25 in. ( W) X 4.5 in. (D) (19 cm x 16 cm x 11.5 cm) Weight: 4.6 lbs. (2.1 Kgs) Vulcain Alarm Inc. All rights reserved 15 DR0009 February 2004

ELECTRICAL WIRING - VA301D 2 BACK Power: Input J4 and Output J8 15 to 27 Vac, 18 to 38 Vdc, 380 ma @ 24 Vdc. See details in table 2. Relay outputs: Relay 2, J11 5 A, 30Vdc or 250Vac (resistive load). End of line resistor: JP1 On the last transmitter of the communication network, a jumper must be installed. 4-20 ma loop: Output at J7 See details in table 4. Relay outputs: Relay 1, J1 5 A, 30Vdc or 250Vac (resistive load). Communication: Input J6 and Output J3 Vulbus protocol: Up to 16 transmitters per bus. The maximum distance between the controller and the furthest transmitter is 2000 feet. Modbus protocol: Up to 128 transmitters per bus. The maximum distance between the controller and the furthest transmitter is 4000 feet. See details in table 3. DR0009 February 2004 16 Vulcain Alarm Inc. All rights reserved

90DM 3 R USER INTERFACE SPECIFICATIONS Power Requirements: Operating Temperature Range: Operating Humidity Range: Outputs: During normal operation, the display will show a + and an x alternately to indicate the processor is functioning. Also shown is the transmitter address and the gas type. The gas concentration read is shown on the second line. 17-27 Vac, 24-38 Vdc, 200 ma 32 F to 100 F (0 to 40 C) 0 to 95% RH (non-condensing) 1 SPDT optional relay 5A, 30 Vdc or 250 Vac (resistive load) Maximum Distance Between the Controller and the Transmitter: 2,000 feet (600 m) Dimensions: 5.25 in(h) x 3.5 in( W) x 2.0 in(d) (11.5 cm x 7.5 cm x 4.4 cm ) Vulcain Alarm Inc. All rights reserved 17 DR0009 February 2004

ELECTRICAL WIRING - 90DM 3 R Communication: Input J11 From the VA201C controller Relay Output: J9 (option) 5 A, 30 Vdc or 250 Vac (resistive load) Enter Key: Validation Key Power: Input J4 From VA201C controller If the 4-20mA output is present and configurated in active mode, a local power supply is required: 17 to 27 Vac, 24 to 38 Vdc, 200 ma End of line resistor: JP1 On the last transmitter of the communication network, a jumper must be installed. Scroll Key: Browsing key in menu mode DR0009 February 2004 18 Vulcain Alarm Inc. All rights reserved

VASQNA USER INTERFACE Green LED: Power ON Red LED A and B: Indicate that one or more transmitters have reached their first (Level A) or second (Level B) alarm level. Yellow LED: Fault Display: On the first line, the first three letters indicate the status of the operation. Nor: normal or Alr: high gas concentration alarm or fault. On the same line is the transmitter address and the last 8 characters indicating the gas detected and its unit. Second Line Concentration read and unit of measurement Keypad: The MENU key provides access to the Programming Menu and validates a choice or value. ESC key is used to quit the Programming Menu. The UP and DOWN arrow keys are used to modify a parameter or value. SPECIFICATIONS Power Requirements: Operating Temperature Range: Operating Humidity Range: Outputs: 17-27 Vac, 24-38 Vdc, 200 ma 32 F to 100 F (0 to 40 C) 0 to 95% RH (non-condensing) 3 DPDT relays 5A, 30 Vdc or 250 Vac (resistive load) Maximum Distance Between the Controller and the Transmitter: 2,000 feet (600 m) Dimensions: 8.5 in (H) x 8.6 in ( W ) x 2.5 in (D) (21.3 cm x 13.4 cm x 5.7 cm ) Vulcain Alarm Inc. All rights reserved 19 DR0009 February 2004

ELECTRICAL WIRING - VASQNA Power Source (vac), Communication (A-B) Channel A: J9 Input in the lower terminals and output in the upper terminals (When fed by the VA201C controller) 17-27 Vac, 24-38 Vdc, 250 ma Power Source (vac), Communication (A-B) Channel B: J10 Input in the lower terminals and output in the upper terminals (When fed by the VA201C controller) Relay Outputs: Relay 1: J50, Relay 2: J11 and Relay 3: J12. 5 A, 30 Vdc or 250 Vac (resistive load) DR0009 February 2004 20 Vulcain Alarm Inc. All rights reserved

VA420I SPECIFICATIONS Power Requirements: Operating Temperature Range: Operating Humidity Range: Number of Outputs: 17-27 Vac, 24-38 Vdc, 500 ma 32 F to 100 F (0 to 40 C) 0 to 95% RH (non-condensing) Maximum Distance Between the Controller and the Transmitter: 2,000 feet (600 m) Dimensions: 8 dedicated 4-20 ma outputs 1 min/max and average for 16 different transmitter 8.5 in (H) x 8.6 in ( W) x 2.5 in (D) (21.3 cm x 13.4 cm x 5.7 cm ) Vulcain Alarm Inc. All rights reserved 21 DR0009 February 2004

ELECTRICAL WIRING - VA420I Power and Communication: J15 Input: Lower Terminal Output: Upper Terminal J8: Pull down resistor J7: 1-2, end of line resistor 2-3, end of line RC filter resistor J12: Pull up resistor 4-20 ma Outputs: S2 to S9 4-20 ma outputs may be set to be Current sourcing or Loop-powered Current Sourcing: S2 to S9 jumpers at 1-2, 3-4 and 5-6 Loop-Powered: S2 to S9 jumpers at 2-3, 4-5 and 6-7 When the output reads 3.33mA, the VA420I doesn t see the corresponding transmitter. DR0009 February 2004 22 Vulcain Alarm Inc. All rights reserved

VA201R SPECIFICATIONS Power Requirements: Operating Temperature Range: Operating Humidity Range: Outputs: 17-27 Vac, 24-38 Vdc, 250 ma 32 F to 100 F (0 to 40 C) 0 to 95% RH (non-condensing) 2, 4 or 8 DPDT relays 5A, 30 Vdc or 250 Vac (resistive load) Maximum Distance Between the Controller and the Transmitter: 2,000 feet (600 m) Dimensions: 8.5 in (H) x 8.6 in ( W) x 2.5 in (D) (21.3 cm x 13.4 cm x 5.7 cm ) Vulcain Alarm Inc. All rights reserved 23 DR0009 February 2004

ELECTRICAL WIRING - VA201R Power and Communication: J10 When fed by the VA201C controller If a dedicated power supply is needed: 17-27 Vac, 24-38 Vdc, 250 ma Relay Outputs: Relay 1: J1, Relay 2: J2, Relay 8: J8. 5 A, 30 Vdc or 250 Vac (resistive load) DR0009 February 2004 24 Vulcain Alarm Inc. All rights reserved

VASQN8X USER INTERFACE Audible Alarm Activates intermittently if flow loss is detected, activates for one of the alarm levels reached. (Typically set to Alarm Level C) Gas Outlet Port Visual Indicators I/0 Normal Operation: Green LED Alarm Level 1: First Red LED Alarm Level 2: Second Red LED Alarm Level 3: Both Red LEDs blink Failure: Yellow LED Gas Inlet Port LCD Display The LCD display scans the concentration of the gas read in each sampling zone at an interval of 2 seconds. Sample Points LED Audible Alarm Reset Key Programming Keys ESC: Exit a Menu Menu: Access the programming or acknowledge a programming field or value Up and Down Arrow Keys: Select a programming field or value Scan the reading at a specific sampling zone Vulcain Alarm Inc. All rights reserved 25 DR0009 February 2004

SPECIFICATIONS Sensing Technology: Visual Indicators: Refrigerant (infrared) Electrochemical (toxic) Catalytic Combustion (combustibles) Diffusion Fuel Cell (oxygen) Normal operation: Green LED Alarm Level 1: Red LED Alarm Level 2: Red LED Failure: Yellow LED Sample Points: Green LED 120 VAC, 2A 110 dba at 3 feet (1 meter) Power Requirement: Audible Alarm: Number of Sample Points: Up to 8 Outputs: 3DPDT relays (3 alarm levels or 2 alarm levels and fault) RS-485 Relay Output Rating: 5A, 30 Vdc or 250 Vac (resistive load) Alarm Levels: 3 Maximum Sampling Distance: 1,100 feet (335 meters) Operating Humidity Range: 0% - 95% RH, Non-Condensing Operating Temperature Range: 32 F to 100 F (0 C to 40 C) Low temperature range available Dimensions: 19.0 in (H) x 11.75 in ( W ) x 4.50 in (D) (48.26 cm x 29.85 cm x 11.43 cm) Weight: 22.4 lbs (10.17 kg) DR0009 February 2004 26 Vulcain Alarm Inc. All rights reserved

ELECTRICAL WIRING A dedicated circuit must be used for the VASQN8X. Communication: Output J9 (A-B) Used only with network configuration. (See details in the VA201C and VA420I User s Manual) Connector J10: Used to power and communicate with the transmitter(s). Relay Output: Relay 1: J50 Relay 2: J11 Relay 3: J12 5 A, 30 Vdc or 250 Vac (resistive load) Power: 120 Vac, 2 A Vulcain Alarm Inc. All rights reserved 27 DR0009 February 2004

SURFACE-MOUNT INSTALLATION Installation of the monitor (stand-alone) or transmitter (network) simply requires the physical mounting of the enclosure and connection of the power and output lines. TABLE 5 Recommended Height Detected Gas Relative Density Height (air = 1) CO Carbon Monoxide 0.968 1-1.5 m (3-5 feet) from floor NO 2 * Nitrogen Dioxide 1.58 (cold) 30 cm to 1 m (1-3 feet) from ceiling H 2 Hydrogen 0.07 30 cm (1 foot) from ceiling CL 2 Chlorine 2.50 30 cm (1 foot) from floor NH 3 Ammonia 0.59 30 cm (1 foot) from ceiling H 2 S Hydrogen Sulfide 1.19 30 cm (1 foot) from floor HCL Hydrogen Chloride 1.30 30 cm (1 foot) from floor HCN Hydrogen Cyanide 0.932 30 cm (1 foot) from floor ETO Ethylene Oxide 1.50 30 cm (1 foot) from floor O 2 Oxygen 1.43 1-1.5 m (3-5 feet) from floor SO 2 Sulfur Dioxide 2.25 30 cm (1 foot) from floor R11 5.04 R12 4.20 R22 Refrigerants 3.11 30 cm (1 foot) from floor R123 5.27 R125 4.14 R134A 3.52 COMB Most combustibles are heavier than air, with the exception of methane, hydrogen, ethylene and acetylene. For gases that are heavier than air, sensors should be installed approximately 30 cm (1 foot) from the floor. For combustibles that are lighter than air, sensors should be installed 30 cm (1 foot) from the ceiling, close to the potential leak source. * May differ in certain applications. Hot NO 2 from the exhaust system is lighter than 1.58. DR0009 February 2004 28 Vulcain Alarm Inc. All rights reserved

DETERMINATION OF NUMBER OF SYSTEMS The number of transmitters required is determined by a unit s operational radius of surveillance. Using Table 6 below, the number of units required can be easily evaluated. Table 6 Gas Detected Radius of Surveillance Area Covered CO Carbon Monoxide 50 feet 7,854 square feet NO 2 Nitrogen Dioxide (15 metres) (707 square metres) Others 23 feet 1,662 square feet (7 metres) (154 square metres) Vulcain Alarm Inc. All rights reserved 29 DR0009 February 2004

RANGE AND ALARM LEVELS TABLE 7 Range and Alarm Levels Gas Detected Range Alarm Level A Alarm Level B CO Carbon Monoxide 0-250 PPM 35 PPM 200 PPM NO 2 Nitrogen Dioxide 0-10 PPM 0.72 PPM 2 PPM CL 2 Chlorine 0-15 PPM 0.5 PPM 1 PPM H 2 Hydrogen 0-2,000 PPM 1,500 PPM 1,800 PPM NH 3 Ammonia 0-100 PPM 25 PPM 35 PPM H 2 S Hydrogen Sulfide 0-50 PPM 10 PPM 15 PPM HCL Hydrogen Chloride 0-25 PPM 3 PPM 4 PPM HCN Hydrogen Cyanide 0-50 PPM 5 PPM 9 PPM ETO Ethylene Oxide 0-10 PPM 1 PPM 5 PPM O 2 Oxygen 0-25% Vol. 19.5% Vol. 22% Vol. SO 2 Sulfur Dioxide 0-10 PPM 2 PPM 5 PPM R-123 Refrigerant Q1 0-1,000 PPM 50 PPM 500 PPM R-11 Refrigerants Q1 0-1,000 PPM 250 PPM 500 PPM R-12 Refrigerants Q2 0-2,000 PPM 1,000 PPM 1,800 PPM R-22 R-125 R134A Combustibles 0-100% LEL 25% LEL 50% LEL When the level of alarm has been reached, the corresponding relay will remain activated for a minimum of 59 seconds. A different alarm level may have been programmed in order to satisfy the constraint of a particular application. DR0009 February 2004 30 Vulcain Alarm Inc. All rights reserved

PCT-1TX SINGLE-POINT SAMPLE-DRAW ALL-WEATHER HOUSING The PCT-1TX is designed to enhance the transmitter s use in environments needing Nema 4 protection or in extreme climatic conditions. The aspiration system offers the possibility of mainteance accessibility for a transmitter while air aspiration is made in out of reach areas. If a lower range of temperature operation is needed, a heating option is available in order to stabilize the temperature inside the unit. To assure steady aspiration flow on the pump, an optional flow surveillance system with strobe light is also offered. Vulcain Alarm Inc. All rights reserved 31 DR0009 February 2004

DETECTION PARAMETERS Time Delay Before Alarm: Time Delay After Alarm: Table 8 Transmitter Level A Outputs Level B Outputs DR0009 February 2004 32 Vulcain Alarm Inc. All rights reserved