Wall fans. High air performance and low energy consumption

Similar documents
Axial fans The right fan for every house

CombiTunnel-Ventilation

Heating Systems. An ideal temperature in every pig house

Milling ing and Mixing Systems

MagixX & StuffNix. Exhaust air treatment systems for efficient reduction of emissions from poultry houses

307pro. The computer for optimal climate control in every pig house

ViperTouch. The flexible climate and production computer for your poultry house

Fresh air supply systems

HydroMix. The computer-controlled liquid feeding system for profitable pig production

CombiTunnel ventilation

Fresh air supply systems

HydroMix. The computer-controlled liquid feeding system for profitable pig production

MagixX & StuffNix. Exhaust air treatment for pig and poultry houses

The computer for optimum climate in every pig house

Solutions for. HVAC/Refrigeration. Axial Fans and Clutches

Axial flow fan AXICO ANTI-STALL

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

SAX. Window & Wall Fans

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS


Fa n s. Fans AF/LA Series AFT Series MAP/AVP/MF/XF Series AFH Series Centrifugal fan units OR/COR/ORV Series CNX/MXF Series ATEX Fans

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

and SHUTTERS Made to Work. Built to Last.

POWERPLUS SPP Product Brochure

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

HEAT RECOVERY AIR HANDLING UNIT

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Broiler Feeding System

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

Mini fans MiniVent M1/100

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Double Skin Air Handling Units

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

TUNNEL FANS STANDARD AND HOT SMOKE

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Ventilation. The idea behind our climate systems is efficiency and advanced simplicity.

Evaluation Report 509

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Double Skin Air Handling Units

Colt CoolStream Adiabatic Cooling & Ventilation System

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Company History Locations Product range References

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

Product catalogue. Solutions for the Dairy segment

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

Heat Exchanger Earny Type

Chore-Time Fan Guide For Tunnel and Other Applications

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

BERNSTEIN Safety Rope Pull Switches SR and SRM

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

Centeral Station Air Handling Unit

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

AIR HANDLING UNITS MANDÍK

Tunnel Axial Flow Fan

COOLflow 4E PRODUCT RANGE

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Product catalogue. Solutions for the Poultry segment

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

E-Wheel Backward Curved Centrifugal Fans

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Wind. Service instruction

We optimize performance.

Centrifugal Fans, Non-Overloading, Backward Inclined

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

English CNA-CNB. Centrifugal fans Installation and maintenance

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

Evaporators 60HZ version

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

COTES ALL-ROUND THE C30 RANGE

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Technical data Chimney fans, controllers and accessories in systems for gas fireplaces, stoves and single non-modulating gas boilers

Technology for life. Unit heater LH

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Colt CoolStream Evaporative Cooling & Ventilation System

products 22 º C Ventilation Air Conditioning Refrigeration Unit heaters Inside PROVIDED BY HEINEN & HOPMAN

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

COTES ALL-ROUND THE C65 RANGE

The Straight Way K Sileo Series

Packaged Air Conditioning Custom Build Solutions

Vacuum cleaner Instruction manual

HasconWing. Fixed or variable airfoil profile axial impellers

KOMFORT EC DB Suspended heat recovery air handling units

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

Transcription:

Wall fans High air performance and low energy consumption

Wall fans efficient and durable The Big Dutchman wall fans are very versatile with a high performance, low energy consumption and low maintenance costs. They are also corrosion-proof and made for a long service life. Thanks to the large variety they can be ideally adapted to any type of barn. In addition to steelframe axial fans, we also offer V-belt driven fans. Let our experts advise you which solution best fits your requirements. Axial fans with frame Excellent adjustability Our axial fans with frame are ideally suited for incorporation into walls. The frame has an aerodynamic shape and is made of high-quality sheet steel. The blades are made of moulded aluminium diecasting and therefore have an exceptionally high degree of efficiency. Our product range includes standard fans (FC) as well as sickle-shaped fans (FE), the latter being more pressure-resistant and quieter. Standard fan (FC) Sickle-shaped fan (FE) Advantages 4 excellent adjustability; 4 high air capacity at a low energy consumption; 4 low noise level; 4 quick and easy assembly; 4 high corrosion resistance; 4 long service life. Wire mesh guard A wire mesh guard is required if the fan is installed in an accessible location. Shutters This shutter is a self-actuated closing flap made of PVC. If the fan is at a standstill, the shutter is closed. Dimensions and installation details Ø Impeller A B C D E F (in cm) (in mm) 35 435 485 375 86 75 89 40 490 540 420 91 88 102 45 535 575 480 75 96 123 50 615 655 528 77 104 141 56 675 725 589 60 119 138 63 750 805 664 64 130 154 71 810 850 763 44 150 202 80 910 970 869 34 193 252 91 1010 1070 977 48 190 197

AirMaster High air performance Advantages 4 optimised aerodynamics at the air admission and air exit sides for a high air flow rate; 4 specially-formed blades ensure optimum operation thus reducing energy costs; 4 the shutters open by the air flow pressure and stay open thanks to balancing weights > minimal air resistance; 4 low noise level; 4 stable, robust and simple design; 4 easy to assemble and easy to install in the building. Important components Casing The fan casing consists of galvanized sheet steel, the inside construction is made of high-quality polypropylene for a high corrosion resistance. Blade and blade hub The vane has 3 or 5 specially shaped blades made of glass-fibre reinforced plastic. Air guide-rails on every blade ensure a large air capacity combined with a low resistance and thus low energy consumption. The blade hub is made of aluminium. The 5-blade AirMaster is often installed in barns with a high back pressure (cage houses with tunnel ventilation, use of exhaust air treatment systems). Shutters The shutters are opened by the air flow and then kept open by means of a balancing weight. When the fan stops, the shutters close. V-belt gearing The V-belt pulley is made of aluminium and is manufactured as one piece together with the blade hub by diecasting. The V-belt is pretensioned, further tensioning is therefore not necessary. Electric motors We use high-quality motors with a large voltage range (motor protection IP 55, approved for UL/CSA). The motor is completely closed; a separate cooling fan is not necessary. This means there is no danger of dust entering the motor or overheating of the motor. electric motor without cooling fan with protective cover > well-protected against dust specially-formed blades made of glass-fibre reinforced plastic with air guide-rails for optimum air performance all 4 corners are equipped with plastic covers > no dirt corners > good hygiene central V-belt pulley made of aluminium with pretensioned V-belt > retensioning not necessary shutters are opened by the air flow > a centrifugal system is not necessary diagonal braces for better stability extremely stable connection between hub and blade > copes well with high loads fan with 3 or 5 blades

Dimensions: V130 VC130 95 522 275 152 85 85 133 275 1275 782 Ø1600 If used in the EU, the fans must carry the CE mark of conformity. As opposed to fans without CE mark these fans possess a protective grating (in front of the shutters at an installation height below 2.70 m). AirMaster with cone Cone fans (VC130) are mainly used in barns with especially large air-flow performance requirements. They are also characterized by a low power consumption. Light trap Big Dutchman offers two light traps. The previous model reduces the amount of light passing through the fan to a minimum and is thus especially suited for rearing and breeding houses. The air performance is reduced by approx. 12 %. The new light trap PerforMacs is ideally suited for broiler and laying houses. It has been optimised aerodynamically, reducing the air performance by only approx. 10 %. The segments of both light traps are made of plastic which makes them extremely durable and easy to clean. Technical specifications of the series AirMaster V130/VC130 Type Code No. Speed Air capacity in m 3 /h Consumption Spec. output Noise level control 0 Pa 20 Pa 30 Pa 40 Pa 60 Pa 80 Pa Ampere Watt/1000m 3 /h db(a)* V130-3 1.0 PS E13 60-25-4509 NC 40400 36100 33100 29900 2.2 27.5 72 V130-3 1.5 PS E13 60-25-4501 NC 44700 40500 38400 36000 29300 3.0 33.6 74 V130-3 1.5 PS E13 60-25-4503 FC 44700 40500 38400 36000 29300 3.0 33.6 74 V130-5 1.5 PS E13 60-25-4505 NC 39600 36500 35000 33400 29800 25600 3.0 34.3 74 V130-5 1.5 PS E13 60-25-4507 FC 39600 36500 35000 33400 29800 25600 3.0 34.3 74 V130-3 1.5 PS-R 60-25-4141 FC 43700 39700 37500 34800 28600 19200 3.1 36.7 74 V130-5 1.5 PS-R 60-25-4140 FC 38700 35600 34100 32500 28800 24500 3.0 36.8 74 VC130-3 1.0 PS E13 60-25-4565 NC 44500 40400 37800 35400 2.3 24.6 72 VC130-3 1.5 PS E13 60-25-4561 NC 49000 45200 43100 40700 35900 3.0 29.9 74 VC130-5 1.5 PS E13 60-25-4563 NC 43100 40000 38700 37000 33900 28300 3.0 29.8 74 VC130-3 1.5 PS-R 60-25-4020 FC 47700 43800 41600 39200 34300 21800 3.2 34.3 74 VC130-5 1.5 PS-R 60-25-4060 FC 41800 38800 37200 35600 32300 27100 3.1 33.4 74 V = fan without cone; VC = fan with cone; 130 = diameter of impeller; 3 = 3-blade; 5 = 5-blade; R = standard motor (only for use outside of the EU) E13 = complies with the directive 2009/125/EC (ErP Directive) starting 2013 NC = non-controllable FC = frequency-controllable Connection values: 400 V, 50 Hz; on request available with other voltages and frequencies Weight: AirMaster without cone: 80 kg; AirMaster with cone: 99 kg * Noise level measured at the outlet side 45 lateral, at a distance of approx. 2 m; all types also available unassembled

Technical specifications of axial fans with frame Description details FC035-4EQ FC = standard fan 4 = 4-pole; 6 = 6-pole E = 1-phase (1~ 230 V) FE091-6DQ FE = sickle-shaped fan 35 = dia impeller (cm) D = 3-phase (3~ 400 V) Q = wall installation Technical specifications: 1 ~ 230 V, 50 Hz FC035-4EQ FC040-4EQ FC045-4EQ FC050-4EQ FC056-6EQ FC063-6EQ FC071-6EQ FC080-6EQ FE091-6EQ Code No. 60-47-9135 60-47-9140 60-47-9145 60-47-9150 60-47-9156 60-47-9163 60-47-9171 60-47-9180 60-47-9191 Power consumption (Watt) 157 243 341 450 388 545 785 1.160 895 Nominal current (Ampere) 0.75 1.3 1.9 2.3 1.95 2.7 4.1 6.3 4.6 Motor protection switch (Ampere) 1.0 1.4 2.3 2.7 2.2 3.0 4.6 6.7 5.2 Noise level (db(a)) 46 51 53 54 48 53 55 55 57 The noise level was measured free-blowing at a 45 angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase). Technical specifications: 3 ~ 400 V, 50 Hz FC045-4DQ FC050-4DQ FC056-6DQ FC063-6DQ FC071-6DQ FC080-6DQ FE091-6DQ Code No. 60-47-9645 60-47-9650 60-47-9656 60-47-9663 60-47-9671 60-47-9680 60-47-9691 Power consumption (Watt) 295 432 323 484 780 1120 939 Nominal current (Ampere) 0.8 1.1 0.74 1.4 1.8 2.7 1.95 Motor protection switch (Ampere) 0.9 1.3 0.8 1.5 1.9 3.1 2.4 Noise level (db(a)) 53 54 48 53 55 55 57 The noise level was measured free-blowing at a 45 angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase). Air capacity Single-phase power supply 230 V, 50 Hz: capacity (m 3 /h) / spec. output (W/1000 m 3 /h) Type / Negative pressure 0 Pa 10 Pa 20 Pa 30 Pa 40 Pa 50 Pa FC035-4EQ 3460 / 45.4 3320 / 47.9 3180 / 50.9 3050 / 53.8 2910 / 57.0 2810 / 59.4 FC040-4EQ 4790 / 48.2 4510 / 52.1 4240 / 56.6 3950 / 61.5 3640 / 67.3 3260 / 75.2 FC045-4EQ 6350 / 53.7 6260 / 55.9 6120 / 58.0 5950 / 61.2 5780 / 64.9 5560 / 68.3 FC050-4EQ 8000 / 55.4 7800 / 58.1 7660 / 61.0 7400 / 64.6 7250 / 67.7 6900 / 73.0 FC056-6EQ 8870 / 43.7 8560 / 46.0 8210 / 49.0 7860 / 51.7 7430 / 55.3 6910 / 60.3 FC063-6EQ 12300 / 42.3 11750 / 45.3 11400 / 47.6 11000 / 50.0 10550 / 53.0 10000 / 56.8 FC071-6EQ 16450 / 47.6 15950 / 50.4 15550 / 52.7 15000 / 55.6 14600 / 58.2 14000 / 61.2 FC080-6EQ 23000 / 50.4 22300 / 53.4 21700 / 56.0 21050 / 58.7 20450 / 61.4 19850 / 64.3 FE091-6EQ 23130 / 38.7 22200 / 41.3 21200 / 44.1 20100 / 46.9 18600 / 50.8 17600 / 54.0 The capacity was measured without wire mesh guard and at an air density of 1.2 kg/m 3. Three-phase power supply 400 V, 50 Hz: capacity (m 3 /h) / spec. output (W/1000 m 3 /h) Type / Negative pressure 0 Pa 10 Pa 20 Pa 30 Pa 40 Pa 50 Pa FC045-4DQ 6470 / 45.6 6290 / 48.0 6130 / 50.4 5950 / 52.9 5820 / 55.3 5650 / 58.1 FC050-4DQ 8330 / 51.1 8120 / 53.8 7970 / 56.3 7800 / 59.6 7630 / 62.1 7470 / 64.3 FC056-6DQ 8850 / 36.5 8530 / 38.7 8200 / 41.3 7850 / 44.5 7480 / 47.3 7060 / 50.7 FC063-6DQ 12750 / 38.0 12380 / 40.4 12000 / 43.0 11650 / 45.5 11190 / 48.7 10760 / 51.3 FC071-6DQ 17000 / 45.9 16600 / 48.2 16150 / 50.5 15600 / 53.1 15300 / 54.8 14800 / 57.6 FC080-6DQ 22900 / 48.9 22440 / 51.3 21920 / 53.6 21400 / 56.4 20900 / 58.9 20340 / 61.5 FE091-6DQ 23370 / 36.5 22400 / 34.4 21410 / 41.4 20450 / 44.0 19450 / 46.7 18410 / 49.7 The capacity was measured without wire mesh guard and at an air density of 1.2 kg/m 3. The motors are fabricated according to the IP 54 (dust-proof and water-proof) protection system. All mentioned fans 1 ~ 230 V and 3 ~ 400 V can be controlled electronically or by a transformer. On request the fans are also available frequency-controlled and/or with different supply voltage and/or 60 Hz.

Areas of application Our wall fans are very versatile. Depen ding on the climate zone, different ventilation concepts are possible. Side and cross ventilation are often established by means of axial fans. They pull the air across the barn. Longitudinal ventilation is normally accomplished by means of AirMaster fans as these have a higher air capacity. In case of tunnel ventilation they pull the air through the barn in longitudinal direction at a high air speed. This is a so-called displacement ventilation at minimum energy consumption. CombiTunnel ventilation is best installed in climate zones with large temperature fluctuations summer/winter or day/night temperatures. In the case of decentralized exhaust air extraction via chimneys in the roof, AirMaster fans in the gable can be switched on for additional ventilation on hot summer days. Cross ventilation Side ventilation Longitudinal ventilation Tunnel ventilation CombiTunnel ventilation Decentralized exhaust air extraction with additional gable ventilation Germany: Big Dutchman International GmbH Big Dutchman Pig Equipment GmbH Postfach 1163 49360 Vechta Tel. +49(0)4447 801-0 Fax -237 big@bigdutchman.de www.bigdutchman.de USA: Big Dutchman, Inc. Tel. +1 616 392 5981 bigd@bigdutchmanusa.com www.bigdutchmanusa.com Brazil: Big Dutchman (Brasil) Ltda. Tel. +55 16 2108 5300 bigdutchmanbrasil@bigdutchman.com.br www.bigdutchman.com.br Russia: OOO Big Dutchman Tel. +7 495 2295 171 ikotov@bigdutchman.ru www.bigdutchman.ru Asia/Pacific: BD Agriculture (Malaysia) Sdn. Bhd. Tel. +60 3 33 61 5555 bdasia@bigdutchman.com www.bigdutchman.com BD Agriculture (Thailand) Ltd. Tel. +66 2 349 6531 bdt@bigdutchman.com www.bigdutchman.co.th Abb. 762 China: Big Dutchman (Tianjin) Livestock Equipment Co., Ltd. Tel. +86 10 6476 1888 bdcnsales@bigdutchman.com www.bigdutchman.cn Technical details subject to change. en 6/2013