MMF Six Zone Interface Module

Similar documents
IDP-Zone-6 Six Zone Interface Module

CZ-6A Six Zone Interface Module

SC-6 Six Supervised Control Module

Multiple Input and Output Modules

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Addressable NAC Output Module D327A

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Booster Power Supply Manual

4100U City and Relay Cards Installation Instructions

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

The ACM-8R Annunciator Control Module

RMS/RPX Reader. User Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

MS-2410BC. Conventional Fire Alarm Control Panel. Programming, Installation, Maintenance and Operating Instruction Manual

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

F220-B6PS/M. Installation Guide. Addressable Detector Bases

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

180 Degree Ceiling Mounted Occupancy Sensors

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Independent Zone Control (I.Z.C.)

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Multiplex Eight Input Remote Modules

Installation Instructions Model HZM

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Installer Guide smart connect

SIGA-CC1 Single Input Signal Module Installation Sheet

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

The RPT-485W/RPT-485WF

Model 17A00 Expansion Enclosure

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

ANNUNCIATOR FIXED MODULE

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

1125 PIR Motion Detector

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

MANUAL RESET ALARM RELEASE

Wireless ShatterPro Acoustic Sensor Installation Instructions

PRODUCT DIAGRAM PACKAGE CONTENTS

SILENT KNIGHT. Model SK-2/E & SK-4/E. Installation and Operations Manual. Fire Alarm Control Panel. Part Number Rev. A ECN /08/05

Conventional Fire Alarm Control Panel

PRODUCT DIAGRAM PACKAGE CONTENTS

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

Fire Alarm Control Panels MS-2 & MS-4 MS-2E & MS-4E. Instruction Manual. Document /6/2014 Rev: G3 P/N 51512:G3 ECN

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Annunciator Modules. for Fire Lite Fire Alarm Control Panels. Document # /30/95 Revision:

Long Range Radio Alarm Transmitter

These instructions detail procedures to follow in order to avoid damage to equipment.

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

Remote NAC Power Supply D7038

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

PSN-1000 & PSN 1000(E) Installation Manual

Installation and ZONES: Operation Manual. Model: ON STI-34108

AFP-100 Intelligent Fire Panel

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

RELEASE DEVICE CONTROLS

Table of Contents. What to Expect with. Mounting Options. Tools Needed

General Routing Interface

Fire alarm system specification for multiple tenant retail buildings

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

NetworX NX-548E Receiver Installation Instructions

The MS-4424 FIRE ALARM CONTROL PANEL

Addressable Detectors & Bases

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

INSTALLATION GUIDE XTLN-WIFI PANEL

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Fire Alarm Control Panel MS-2410B & MS-2410BE

/5121/5122 TrueAlert Power Supply Installation Instructions

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Public Safety DAS Annunciator Panel

1126 Series Ceiling Mount PIR Motion Detector

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Print Specification. Publication. Instructions. Specific requirements. General requirements

Duct smoke housing, 2-wire D340/D340P

Installer Guide smart connect

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

ITEM # SAIL STREAM CEILING FAN MODEL #41695

Operation and Installation Guide. Fire Alarm Control Panel

WatchDog Wireless Crop Monitor Operation Manual

40 Built-in Electric Fireplace Operating and Installation Instructions

FTP-1000 Touchpad/Display Installation Manual

/9308 External Battery Chargers Installation Instructions

REMOTE CONTROL MANUAL

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

HP101U Conventional Fire Alarm Control Panel Installation And Operation Manual

Lamp Driver Module LDM-32F

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

FCPS-24/FCPS-24E. Field Charger/Power Supply. Installation, Operation and Application Manual.

Transcription:

Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid on) Temperature Range: F to 0 F (0 C to 49 C) Humidity: 0 to 9% Non-condensing Dimensions: 6.8 H x 5.8 W x.5 D Accessories: CH-6 Chassis; BB-6 Cabinet; BB- Cabinet Wire Gauge: -8 AWG Maximum IDC Wiring Resistance: 5 Ohms External Power Supply Voltage: Regulated 4VDC Ripple Voltage: 0. volts RMS maximum IDC (supervised and power limited) DC Voltage: 8-8 volts power limited Frequency: DC Current: 90mA per circuit One FireLite Place Northford, CT 0647 Phone: 0.484.76 BEFORE INSTALLING This information is included as a quick reference installation guide. Refer to the appropriate Fire Lite control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect the power to the control panel before installing the modules. This system contains static sensitive components. Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. The module housing should also be grounded. NOTICE: This manual should be left with the owner/user of the equipment. GENERAL DESCRIPTION The MMF-0-6 Six Zone Interface Module is intended for use in an intelligent alarm system. Each module provides an interface between the intelligent alarm system and a conventional alarm system loop. A common input is used for all modules, and the initiating device loops share a common supervisory supply and ground. Otherwise, each monitor operates independently from the others. Each module has its own unique address. A pair of rotary code switches is used to set the address of the first module from 0 to 54. The remaining modules are automatically assigned to the next five higher addresses. Provisions are included for disabling a maximum of two unused modules to release the addresses to be used elsewhere. Each module also has panel controlled bicolor LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. Compatible Two-wire System Sensor Smoke Detectors for use with MMF-0-6 with Zone A Identifier DET. DETECTOR MODEL COMP. ID MANUFACTURER BASE MODEL MAX DET. 5 A SYSTEM SENSOR B0LP,B40 45 A SYSTEM SENSOR B40, B40B 0 45DH A SYSTEM SENSOR DH400 0 5 A SYSTEM SENSOR B0LP, B40 45 A SYSTEM SENSOR DH400, B40B,B40 45TH A SYSTEM SENSOR B40, B40B 0 545 A SYSTEM SENSOR B40 00 A SYSTEM SENSOR N/A 0 400 A SYSTEM SENSOR N/A 0 ** 00AT A SYSTEM SENSOR N/A 0 00B A SYSTEM SENSOR N/A 0 00D A SYSTEM SENSOR N/A 0 00S A SYSTEM SENSOR N/A 0 00TB A SYSTEM SENSOR N/A 0 00TD A SYSTEM SENSOR N/A 0 00TS A SYSTEM SENSOR N/A 0 00B A SYSTEM SENSOR N/A 0 00TB A SYSTEM SENSOR N/A 0 400 A SYSTEM SENSOR N/A 0 400TH A SYSTEM SENSOR N/A 0 * W-B A SYSTEM SENSOR N/A 0 * W-TB A SYSTEM SENSOR N/A 0 DH00LP A SYSTEM SENSOR N/A 0 * Class B, Style B Only ** No Accessory will be supported by 00AT F00--00 I56-900-005

67 8 5 4 0 5 4 67 8 5 4 0 ADDRESS DISABLE 5 4 4 56 7 8 9 4 56 7 8 9 ADDRESS DISABLE Included: (5) x 4 Terminal Blocks () /4 Stand offs () Shunts (4) Machine Screws () Nuts () Long Power Supply Jumper (6).9k Ohm End of Line Resistors INSTALLATION STEPS. Cabinet Mounting In a clean, dry area, mount the backbox using the four holes provided in the back surface of the cabinet (Figure ).. Chassis Installation The CH-6 chassis is mounted in the BB-6 cabinet. It is attached to the two PEM studs on the back wall of the cabinet with two 8- hex nuts. The hex nuts are included with the chassis (Figure 4). Figure. Typical mounting hole locations: BACKBOX MOUNTING HOLES Shipped on Board: () Shunts in Class A/B position (Shipped in Class B position, remove shunts for Class A) COMPATIBILITY REQUIREMENTS To ensure proper operation, this module shall be connected to a compatible Fire Lite system control panel (list available from Fire Lite). Contact System Sensor for a current list of compatible detectors. COMPONENTS Following are descriptions of the MMF-0-6 mounting frameworks. There are two mounting options for MMF-0-6 modules: Up to six MMF-0-6 modules can be installed on a CH-6 in a BB-6 cabinet One or two MMF-0-6 modules can be installed in a BB- cabinet Chassis The CH-6 chassis is used to mount MMF-0-6 modules in a BB-6 cabinet. It accommodates up to six MMF-0-6 modules in a single cabinet row three modules wide and two modules deep. Figure. CH-6 Chassis: C006-00 The BB- cabinet has a built-in chassis that will accommodate one or two MMF-0-6 modules. Figure. BB- Cabinet: Figure 4. Mounting the CH-6 chassis: Mount with hex nuts to PEM studs on back of cabinet The BB- cabinet comes with the chassis already installed, so no mounting is necessary.. Module Installation There are two methods for installing a module in the rear position of a chassis. Method one is for installation of a rear module only, when no module will be installed in front of it. Refer to Figure 5 for instructions. Method two is for installation of a rear module when another module will be installed in the chassis position in front of it. Refer to Figures 6a and 6b for method two. All necessary screws and standoffs are supplied with the modules. Figure 5. Installation of rear module only, method one: C05-00 C09-00 9 0 9 0 C07-00 C05-00 The front MMF-0-6 module positions of each chassis are offset below the rear MMF-0-6 module positions so that all of the status indicators are visible. Cabinets A BB-6 will house the CH-6 chassis with up to six MMF-0-6 modules installed on it. Refer to cabinet installation documents for dimensions. The BB- cabinet houses one or two MMF-0-6 modules on the internal chassis that is part of the cabinet. Refer to cabinet installation documents for dimensions. Step : Step : Step : Step 4: Insert the bottom of the MMF-0-6 module down into a rear slot on the chassis. Carefully swing the upper edge of the board back towards the back of the chassis until it touches the two standoffs. Align two 4-40 screws with the two standoffs and tighten. Address and wire the modules according to the instructions in this manual. F00--00 I56-900-005

The steps in Figures 6a and 6b describe and illustrate module installation when the rear chassis position and the position in front of it will be filled. Front position installation is possible only if the rear position is filled with another module. Figure 6a: Installation of MMF-0-6 module in a rear chassis position, method two Step : Insert the bottom edge of the MMF-0-6 module down into a rear slot of the chassis. Step : Carefully swing the upper edge of the board towards the back of the chassis until it touches the short standoff attached to the chassis. Step : Align the long standoff with the short standoff and tighten. Figure 6b: Installation of MMF-0-6 module in front chassis position Step : Insert the bottom edge of the MMF-0-6 module down into a front slot of the chassis. Step : Carefully swing the upper edge of the board towards the back of the chassis until it touches the /4 (.75mm) standoffs installed on the rear module. Step : Align two 4-40 screws with the two standoffs and tighten. Step 4: Address and wire the modules according to the instructions in this manual. WIRING NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.. Install module wiring in accordance with the job drawings and appropriate wiring diagrams.. All wiring to the MMF-0-6 is done via terminal blocks. In order to properly make electrical connections strip approximately /4 of insulation from the end of wire, sliding the bare end of the wire under the clamping plate screw.. Set the address on the modules per the job drawing. Use the rotary code switches to set the address of the first module (between 0 and 54). C05-00 C06-00 In Class B operation, the remaining modules are automatically assigned to the next five higher addresses. For example, if the base address switch is set to 8, the next five modules will be addressed to 9, 0,, and. The module is shipped in Class B position, remove shunts for Class A. When operating in Class A, alternate modules are paired together (0/, /, 4/5), resulting in a total of three modules. For example, if the base address switch is set to 8, then 0 and will be automatically assigned to the modules while 9, and are available to be used for other modules on the. For Class A and B operation, DO NOT set the lowest address above 54, as the other modules will be assigned to nonexistent addresses. NOTE: Some panels support extended addressing. In order to set the module above address 99 on compatible systems, carefully remove the stop on the upper rotary switch (see Figure 7). If the panel does not support extended addressing, do not set the lowest address above 94. 4. A shunt is provided to disable a maximum of two unused modules in Class B operation and Figure 7. 67 8 9 5 0 4 5 4 C07-00 TENS 0 Class A operation. Modules are disabled from the highest address and work downward. If two modules are disabled, the lowest four addresses will be functional, while the highest two will be disabled. For example, in Class B operation, if the shunt for Address Disable is placed on two and the base switch is set to 8, the modules will be assigned to 8, 9, 0 and while disabling the highest two positions. NOTE: Place unused shunts on single pin to store on board for future use. NOTE: Power must not be applied to the unit when changing functionality of the shunts. WIRING NOTES Power-limited circuits must employ type FPL, FPLR, or FPLP cable as required by Article 760 of the NEC. All wiring must be in accordance with the NEC, NFPA 7 and all other applicable codes and standards. All external power supplies must be power limited with battery back-up. All external power supplies and detectors must be UL listed for fire protection signaling applications. PROGRAMMING The MMF-0-6 module operates with the following Fire Alarm Control Panels: MS-900; MS-9600 The modules are programmed as devices in each system according to the programming instructions in the appropriate FACP manual. F00--00 I56-900-005

Figure 8. Interface two-wire conventional detectors Class B, Style B:.9K EOL RESISTOR (INCLUDED) ELR-47K FROM PANEL OR PREVIOUS DEVICE TO NEXT DEVICE CONNECT MODULES TO LISTED COMPATIBLE FIRE LITE CONTROL PANELS ONLY CLASS B IDC (TYPICAL) TO PANEL CONTROLLED RESETTABLE POWER SUPPLY () () POWER-LIMITED AND SUPERVISED IN OUT 0 4 5 DISABLE DISABLE 0 5 4 STATUS INDICATORS SIGNAL LINE CIRCUIT VDC MAX. TWISTED PAIR IS RECOMMENDED. DETECTORS MUST BE UL LISTED COMPATIBLE WITH THE MODULE. INSTALL DETECTORS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. C0779-0. To use a common power supply between multiple MMF-0-6 modules, connect a long power supply jumper from T5 or T6 to T5 or T6 on the adjacent MMF-0-6 module. Figure 9. Interface two-wire conventional detectors Class A, Style D: CONNECT MODULES TO LISTED COMPATIBLE FIRE LITE CONTROL PANELS ONLY FROM PANEL OR PREVIOUS DEVICE TO NEXT DEVICE CLASS A IDC (TYPICAL) TO PANEL CONTROLLED RESETTABLE POWER SUPPLY () () IDC IDC POWER-LIMITED AND SUPERVISED SIGNAL LINE CIRCUIT VDC MAX. TWISTED PAIR IS RECOMMENDED. IN OUT 0 4 5 DISABLE DISABLE 0 5 4 Detectors must be UL listed compatible with the module. Install detectors per manufacturers installation instructions. STATUS INDICATORS C0780-0. To select Class A, remove the two shunts from the A/B select positions.. To use a common power supply between multiple MMF-0-6 modules, connect a long power supply jumper from T5 or T6 to T5 or T6 on the adjacent MMF-0-6 module. F00--00 4 I56-900-005

Figure 0. Example of multiple boards sharing same external supply. Refer to figures 8 and 9 for typical wiring. Make certain lip on long power supply jumper engages retaining tab on T5 or T6 as shown in View A-A: 0 5 4 DISABLE DISABLE 0 5 4 DISABLE DISABLE IN OUT 0 4 5 IN OUT 0 4 5 PCB PCB EXTERNAL POWER SUPPLY C078-00 VIEW A-A This device complies with part 5 of the FCC Rules. Operation is subject to the following two conditions: () This device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interfer- FCC Statement ence will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. F00--00 5 I56-900-005 008 Fire Lite