ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

Similar documents
Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

mechanical. OPERATION Rapidrop Global

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

TECHNICAL DATA. Wet 26a. February 22, 2009

Instructions for Installation, Operation, Care and Maintenance

Discontinued Product

Series 759 FireLock Alarm Check Valve

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

OPEN SPRINKLER SYSTEM

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TECHNICAL DATA OBSOLETE

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. 319a. January 27, 2012

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

BERMAD Fire Protection

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

SECTION AUTOMATIC SPRINKLER PIPING

TotalPac 3 Wet pipe system c/w retard chamber

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

TECHNICAL DATA OBSOLETE

Model DDX Deluge Valve

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

TECHNICAL DATA. model c-2

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

INSTALLATION, OPERATION

Instructions for Installation, Operation, Care and Maintenance

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

SECTION SPRINKLER SYSTEMS

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

FIGURE 1: MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

SECTION FIRE-SUPPRESSION STANDPIPES

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

INSTALLATION, OPERATION

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

SPRINKLERS TABLE OF CONTENTS

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

13-1. Temperature Regulator

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

SECTION DRY-PIPE SPRINKLER SYSTEMS

TotalPac 3 Firecyle III Deluge Remote controlled system

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Technical Data. Installation

B. Related Sections: The following Sections contain requirements that relate to this Section.

LC Series - Light Commercial Pump Station Installation and Operation Manual

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

SMF PUMP OWNER S MANUAL

Series 1140 and 1141 Temperature Regulators

ADDENDUM NO. 3 March 19, 2018

INSTALLATION INSTRUCTIONS

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

568X, 587X, 588X Series

SECTION DRY-PIPE SPRINKLER SYSTEMS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

3/4 HP Model Trimmer Operating Instructions

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

Series 300 VTB. Installation Instructions

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

esfr dry pendent sprinkler Vk501 (k14.0)

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

SECTION SPRINKLER SYSTEMS

Gas Station & C Store SECTION CWM Job No

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

TITAN FLOW CONTROL, INC.

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Transcription:

ALARM VALVE MODEL: SDH-AVA TECHNICAL DA : MINAL SIZE END CONNECTION 200, 50, 00, & 80 Flange X Flange Flange X roove roove X roove MAXIMUM WORKIN PRESSURE THREADED OPENIN MOUNTIN DESCRIPTION 7.5 Bar (250 I) BSPT Vertical FLANE CONNECTION ANSI B6.42 50 (Flange drilling mtaching to ANSI B 6.5 50) TRIM FTORY HYDROSTIC TEST PRESSURE alvanlsed fitting with Brass Valves 35 Kg./ Sq.cm. (500I) FRICTIONAL LOSS IN 200 7.5 Mtrs. TERMS OF EQUIVALENT 50 7 Mtrs. LENTH OF PIPE (C-20) 00 6. Mtrs. 80 4.7 Mtrs. FINISH Red RAL 3000 ORDERIN INFORMION Specify Size of valve, Flange Connection, Trim Details and Pipe OD REFERENCE NFPA 3 and NFPA 25 For 200 FM Approval is rated upto 200I (4 Bar) Alarm Valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. External bypass prevents false alarm under all supply pressure condition. In the event of variable pressure condition, false alarm is prevented with the provision of retard chamber, thus the design allows for installation under both variable and constant supply pressure condition. Operation of one or more automatic fire sprinklers causes the water to flow into the sprinkler system causing the alarm valve to open, allowing continuous flow of water into the system and transmittal of alarm, both electrical and mechanical. OPERION The fire protection system initially when being pressurized, will allow water to flow into the system until the water supply and system pressure is equalized and the clapper closes the waterway. Once the pressure is stabilized, the fire protection system is ready to be placed in service and then the alarm control valve must be opened. Under normal condition, the water pressure gauge connected to the system side of the alarm valve would show a higher or equal pressure reading than the water pressure gauge connected to the supply side of the valve. This occurs because of the bypass line connecting downstream and upstream side of the alarm valve, which allows water pressure surge to pass without lifting the valve clapper off its seat, thereby causing excessive high pressure surge entrapped in the system side due to presence of a check valve, which generally prevents false alarm. Sudden high pressure surge, as might be encountered by the start-up of a large fire pump may lead the valve clapper to lift momentarily, allowing water to flow through grooves in the valve seat to the retard chamber. The water in the alarm line is automatically drained out, which helps to prevent false alarm due to successive transient surge in supply pressure. Restriction assembly located beneath the retard chamber consists of inlet and drain restriction orifices, which are established by considering the volume of the retard chamber to meet the listing and approval requirement with regard to time-to alarm. These requirements represent a balancing of the need to reduce the possible false alarm due to a transient surge in supply pressure and to achieve desired minimum time- to- alarm following a sprinkler operation. www.shieldglobal.com 49

In constant pressure installation, the retard chamber is not required and the water passing through the groove in the alarm valve seat flows directly through restriction nozzle assembly to activate the mechanical and electrical alarm. INSTALLION. SHIELD Sprinkler alarm valve, Model-SDH-AVA must be installed vertically. 2. The alarm valve must be installed in a readily visible and accessible location and provision to be made in such a way that alarm line drain is visible and accessible. 3. Where water pressure fluctuates, the variable pressure trim with retard chamber must be used. Under nonfluctuating water pressure condition, the constant pressure trim, which does not include retard chamber, may be used. 4. The valve must be installed with trim in accordance with the trim data. Failure to follow the appropriate trim connection guidelines may prevent the device from functioning properly as well as void listing, approval and the manufacturer s warranty. 5. Care must be exercised while installing the check valve in the trim to ascertain that they are located with the arrow mark on the check valve body and pointed in proper direction. 6. The contraction and expansion associated with an excessive volume of trapped air could cause the waterway clapper to cycle open and shut. This may result in false alarm or an intermittent alarm. To avoid these, it is recommended to have breather valve in the system piping network and a vent valve at the extreme end of the system to bleed-off the air. 7. The ball valve provided on the alarm line must be kept open and strapped in set position. 8. Pipe connecting the retard chamber and sprinkler alarm bell must be supported properly to avoid loading on the retard chamber. 9. All the newly installed system pipes must be flushed properly before alarm valve is put into service. INSPECTION AND MAINTENANCE A qualified and trained person must commission the system. After few initial successful tests an authorised person must be trained to perform inspection and testing of the system. It is recommended to carry out physical inspection of the system at least twice a week. The inspection should verify that all the control valves are in proper position as per the requirement of the system and no damage has taken place to any component. It is recommended that the alarm valve and its accessories should be examined and performed for following at least quarterly or as demanded by local authorities to ensure reliable and trouble free operation and service.. Inspection and testing is to be carried out only by an authorized person. DO T TURN OFF the water supply valve to undertake repair work or to test the valve, without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back into service. Also do inform the local security personnel and alarm control station, so that a false alarm is not signaled. 2. Open the alarm test valve. Verify that the sprinkler alarm bell and/or the pressure alarm switch/ electric alarm properly actuate. Close the alarm test valve and verify that water has ceased to flow from the alarm line drain. 3. Clean the 20 (3/4 ) strainer provided on the sprinkler alarm bell line. 4. Clean the strainer of restriction assembly. 5. Inspect the check valve clapper located on the bypass line. FALSE ALARM. Inspect the valve rubber clapper face. If worn or damaged, replace it. Be certain that dirt, stone or any other foreign object have not accumulated under the clapper face and lodged in the groove or holes. Clean the clapper face thoroughly. If the seat ring surface is nicked or scoured, it might be possible to repair the same using lapping compound. If not, replace the complete valve or return it to the manufacturer s works for repair. 2. If sprinkler alarm bell is not functioning or the impeller is jammed, please follow the maintenance guideline provided in the catalogue for sprinkler alarm bell. 3. If pressure alarm switch gives a steady signal, but sprinkler alarm generates an intermittent alarm, check sprinkler alarm bell shaft. If both the sprinkler alarm bell and pressure alarm switch are generating intermittent alarm then check for the possible air which is trapped within the sprinkler system. Trapped air is to be bled off. Also the intermittent alarm may occur due to sudden pressure drop and increase in the system. These problems can be corrected by maintaining a steady supply. CAUTION. The UL Listing, FM Approval and manufacturer s warranty are valid only when the alarm valve is installed with trim set and installed as per installation guidelines. 2. Pressure relief valve is required with wet pipe system, when a rise in ambient temperature can cause system pressure to exceed 7.5 Bar (250 I). A 7.7 Bar relief valve setting should be used. 3. For proper operation of the wet system and to minimize unwanted false alarm, it is important to remove trapped air from the system. The air trapped in the system may also cause intermittent operation of the Water Motor Alarm during sustained flow of water. 50 www.shieldglobal.com

Valve Size WEIHT IN K Flange x Flange Flange x roove roove x roove 200 65 54 44 50 42 35.8 28 00 27 22. 7.3 80 8 5 2. ROOVE PIPE SIZE Normal Size Pipe OD in MM 80 89 00 4.3 50 65. 50 68.3 200 29. Note: For 50 standard supply is 68.3 mm OD pipe roove. For 65.mm specify in order. MINAL PRESSURE LOSS VS FLOW www.shieldglobal.com 5

ALARM VALVE, MODEL SDH-AVA FLANE X ROOVE 2 7 3 3 ROOVE X ROOVE 6 9 5 9 8 FLANE X FLANE 4 2 3 0 PART LIST ITEM 200 PART. 50 00 80 NA NA NA NA AV204 AV54 AV04 AV804 DESCRIPTION 200 Housing (Flange x Flange) Housing (Flange x roove) 50 QTY. 00 80 MERIAL SPECIFICION Ductile Iron Ductile Iron AV204 AV55 AV05 AV805 Housing (roove x roove) Ductile Iron 2 NA NA NA NA Seat Bronze 3 AV2003 AV503 AV003 AV8003 Clapper Bush 2 2 2 2 Brass 4 AV2004 AV504 AV004 AV8004 Hex. Head Bolt 4 Stainless Steel 5 AV2005 AV505 AV005 AV8005 Rubber Clamp Stainless Steel 6 AV2006 AV506 AV006 AV8006 Rubber Seat Neoprene Rubber 7 AV2007 AV507 AV007 AV8007 Clapper Ductile Iron 8 AV2008 AV508 AV008 AV8008 Hinge Pin Stainless Steel 9 AV2009 AV509 AV009 AV8009 Body Bush 2 2 2 2 Brass 0 AV200 AV50 AV00 AV800 Hex. Head Bolt 6 6 4 4 Steel AV20 AV5 AV0 AV80 Sq. Head Plug 2 2 2 2 Forged Steel 2 AV202 AV52 AV02 AV802 Cover asket Neoprene Rubber 3 AV203 AV53 AV03 AV803 Cover Ductile Iron NA: Parts replacement not available 52 www.shieldglobal.com

CONSTANT PRESSURE TRIM FOR ALARM VALVE ROOVE X ROOVE FLANE X ROOVE 7 7 4 5 8 6 5 4 24 D 25 6 3 FLANE X FLANE 29 28 23 27 2 30 22 9 2 NC 0 28 2 2 28 0 26 29 8,28 5 3 4 6 9 2,29 9 7,28 3 26 20 Notes D D Optional Trim Drain To suit at site by installer Normally Open Normally Closed When pressure switch is supplied then Sl.No. 22 plug not required. www.shieldglobal.com 53

ITEM. CODE. CONSTANT PRESSURE TRIM FOR ALARM VALVE DESCRIPTION AV0 Hex Nipple ¾ 4 4 5 2 2 AV02 Tee ¾ 3 3 3 2 3 AV03/ Elbow ¾ 2 2 2 --- 3 AV03/2 Elbow ½ --- --- --- 2 4 AV04/ Pipe Nipple ¾ X 50 mm Long --- --- --- 4 AV04/2 Pipe Nipple ¾ X 30 mm Long --- --- --- 4 AV04/3 Pipe Nipple ¾ X 00 mm Long --- --- --- 4 AV04/4 Pipe Nipple ½ X 00 mm Long --- --- --- 5 AV05/ Pipe Nipple ¾ X 00 mm Long --- --- --- 5 AV05/2 Pipe Nipple ¾ X 80 mm Long --- --- --- 6 AV06/ Pipe Nipple ½ X 00 mm Long --- --- 6 AV06/2 Pipe Nipple ½ X 80 mm Long --- --- 7 AV07/ Union ¾ --- 7 AV07/2 Union ½ --- --- --- 8 AV08/ Swing Check Valve ¾ --- 8 AV08/2 Swing Check Valve ½ --- --- --- 9 AV09/ Pipe Nipple ¾ X 70 mm Long --- --- 9 AV09/2 Pipe Nipple ¾ X 60 mm Long --- --- --- 9 AV09/3 Pipe Nipple ½ X 70 mm Long --- --- --- 0 AV0 Ball Valve ½ 2 2 2 2 AV Reducing Hex Nipple ¾ X ½ --- --- --- 2 AV2 Reducing Hex Nipple ¾ X ¼ 3 AV3 Reducing Hex Nipple ½ X ¼ 4 AV4 Ball Valve ¼ 2 2 2 2 5 AV5 Hex Nipple ¼ 2 2 2 2 6 AV6 Elbow ¼ 2 2 2 2 7 AV7 Pressure auge ¼ 2 2 2 2 8 AV8/ Alarm Test Line Assembly ½ --- --- --- 8 AV8/2 Alarm Test Line Assembly ½ --- --- --- 8 AV8/3 Alarm Test Line Assembly ½ --- --- --- 8 AV8/4 Alarm Test Line Assembly ½ --- --- --- 9 AV9 Reducing Bush ¾ X ½ 2 2 2 20 AV20 Restriction Nozzle Assembly --- 2 AV2 Y Type Strainer ¾ 22 AV22 Plug ½ 23 AV23/ --- 23 AV23/2 --- 24 AV24/ Hex Nipple 2 --- 24 AV24/2 Hex Nipple ¼ --- --- --- 25 AV25/ Angle Valve 2 --- 25 AV25/2 Angle Valve ¼ --- --- --- 26 AV26 Pipe Nipple ½ X 60 mm Long 2 2 2 2 27 AV27 Pipe Nipple ¾ X 80 mm Long 28 AV28 Hex Nipple ½ 3 3 3 5 29 AV29 Tee ½ 2 2 2 3 30 AV30 Pressure Switch (Optional) ½ SIZE QTY 200 50 00 80 54 www.shieldglobal.com

VARIABLE PRESSURE TRIM FOR ALARM VALVE ROOVE X ROOVE FLANE X ROOVE 7 7 30 4 5 8 6 5 4 24 D 25 D 23 27 2 3 @ 22 9 2 6 3 29 28 NC 0 28 32 2 2 28 0 26 29 8,28 5 3 FLANE X FLANE 2,29 9 4 7 6,28 9 3 26 20 D Notes Optional Trim Drain To suit at site by installer Normally Open Normally Closed When pressure switch is supplied then Sl.No. 22 plug not required. www.shieldglobal.com 55

ITEM. CODE. VARIABLE PRESSURE TRIM FOR ALARM VALVE DESCRIPTION AV0 Hex Nipple ¾ 4 4 5 2 2 AV02 Tee ¾ 3 3 3 2 3 AV03/ Elbow ¾ 2 2 2 --- 3 AV03/2 Elbow ½ --- --- --- 2 4 AV04/ Pipe Nipple ¾ X 50 mm Long --- --- --- 4 AV04/2 Pipe Nipple ¾ X 30 mm Long --- --- --- 4 AV04/3 Pipe Nipple ¾ X 00 mm Long --- --- --- 4 AV04/4 Pipe Nipple ½ X 00 mm Long --- --- --- 5 AV05/ Pipe Nipple ¾ X 00 mm Long --- --- --- 5 AV05/2 Pipe Nipple ¾ X 80 mm Long --- --- --- 6 AV06/ Pipe Nipple ½ X 00 mm Long --- --- 6 AV06/2 Pipe Nipple ½ X 80 mm Long --- --- 7 AV07/ Union ¾ --- 7 AV07/2 Union ½ --- --- --- 8 AV08/ Swing Check Valve ¾ --- 8 AV08/2 Swing Check Valve ½ --- --- --- 9 AV09/ Pipe Nipple ¾ X 70 mm Long --- --- 9 AV09/2 Pipe Nipple ¾ X 60 mm Long --- --- --- 9 AV09/3 Pipe Nipple ½ X 70 mm Long --- --- --- 0 AV0 Ball Valve ½ 2 2 2 2 AV Reducing Hex Nipple ¾ X ½ --- --- --- 2 AV2 Reducing Hex Nipple ¾ X ¼ 3 AV3 Reducing Hex Nipple ½ X ¼ 4 AV4 Ball Valve ¼ 2 2 2 2 5 AV5 Hex Nipple ¼ 2 2 2 2 6 AV6 Elbow ¼ 2 2 2 2 7 AV7 Pressure auge ¼ 2 2 2 2 8 AV8/ Alarm Test Line Assembly ½ --- --- --- 8 AV8/2 Alarm Test Line Assembly ½ --- --- --- 8 AV8/3 Alarm Test Line Assembly ½ --- --- --- 8 AV8/4 Alarm Test Line Assembly ½ --- --- --- 9 AV9 Reducing Bush ¾ X ½ 2 2 2 20 AV20 Restriction Nozzle Assembly --- 2 AV2 Y Type Strainer ¾ 22 AV22 Plug ½ 23 AV23/ --- 23 AV23/2 --- 24 AV24/ Hex Nipple 2 --- 24 AV24/2 Hex Nipple ¼ --- --- --- 25 AV25/ Angle Valve 2 --- 25 AV25/2 Angle Valve ¼ --- --- --- 26 AV26 Pipe Nipple ½ X 60 mm Long 2 2 2 2 27 AV27 Pipe Nipple ¾ X 80 mm Long 28 AV28 Hex Nipple ½ 3 3 3 5 29 AV29 Tee ½ 2 2 2 3 30 AV30 Pressure Switch (Optional) ½ 3 AV3 Retard Chamber, Model - RC9 --- 32 AV32 Hex Nipple ¾ SIZE QTY 200 50 00 80 56 www.shieldglobal.com

CONSTANT PRESSURE TRIM - SCHEMIC FLANE X FLANE DOWNSTREAM. (TO SYSTEM) SYSTEM PRESSURE PRESSURE SUPPLY P P ~ UTREAM. (FROM SUPPLY) VARIABLE PRESSURE TRIM - SCHEMIC FLANE X FLANE DOWNSTREAM. (TO SYSTEM) SYSTEM SUPPLY PRESSURE PRESSURE P P RC ~ UTREAM. (FROM SUPPLY) Abbreviation & Symbols Non Return Valve Stop Valve AV Alarm Valve NC Valve Angle Valve Strainer Normally Closed Restriction Nozzle Assembly OD P Control Valve Optional Normally Open Open Drain Pressure auge RC Pressure Switch Retard Chamber Test Valve --- By User TE:- ) Sprinkler alarm control valve must be kept normally open if this valve is kept closed the sprinkler alarm bell/electric alarm will not signal. 2) Sprinkler alarm test valve must be kept normally closed condition. Valve is opened to test the sprinkler alarm bell/ electrical alarm. www.shieldglobal.com 57

CONSTANT PRESSURE TRIM - SCHEMIC FLANE X ROOVE DOWNSTREAM. (TO SYSTEM) SYSTEM PRESSURE PRESSURE SUPPLY P P ~ UTREAM. (FROM SUPPLY) VARIABLE PRESSURE TRIM - SCHEMIC FLANE X ROOVE SYSTEM SUPPLY PRESSURE PRESSURE P P RC ~ Abbreviation & Symbols Non Return Valve Stop Valve AV Alarm Valve NC Valve Angle Valve Strainer Normally Closed Restriction Nozzle Assembly OD P Control Valve Optional Normally Open Open Drain Pressure auge RC Pressure Switch Retard Chamber Test Valve --- By User TE:- ) Sprinkler alarm control valve must be kept normally open if this valve is kept closed the sprinkler alarm bell/electric alarm will not signal. 2) Sprinkler alarm test valve must be kept normally closed condition. Valve is opened to test the sprinkler alarm bell/ electrical alarm. 58 www.shieldglobal.com

CONSTANT PRESSURE TRIM - SCHEMIC ROOVE X ROOVE DOWNSTREAM. (TO SYSTEM) SYSTEM PRESSURE PRESSURE SUPPLY P P ~ UTREAM. (FROM SUPPLY) VARIABLE PRESSURE TRIM - SCHEMIC ROOVE X ROOVE Abbreviation & Symbols Non Return Valve Stop Valve AV Alarm Valve NC Valve Angle Valve Strainer Normally Closed Restriction Nozzle Assembly OD P Control Valve Optional Normally Open Open Drain Pressure auge RC Pressure Switch Retard Chamber Test Valve --- By User TE:- ) Sprinkler alarm control valve must be kept normally open if this valve is kept closed the sprinkler alarm bell/electric alarm will not signal. 2) Sprinkler alarm test valve must be kept normally closed condition. Valve is opened to test the sprinkler alarm bell/ electrical alarm. www.shieldglobal.com 59

INSTALLION DIMENSION WITH TRIM FLANE X FLANE D E A) Constant Pressure Trim WITH CONSTANT PRESSURE TRIM SIZE 80 00 50 200 A 279 32 33 350 B 457 464 486 527 C 434 434 434 443 D 27 40 73 92 E 20 29 234 269 F 262 274 320 378 Unit : mm F C A B D E B) Variable Pressure Trim WITH VARIABLE PRESSURE TRIM SIZE 80 00 50 200 A 279 32 33 350 B 482 488 50 55 C 588 588 588 597 D 27 40 73 92 E 20 29 234 269 F 262 274 320 378 Unit : mm F C A B 60 www.shieldglobal.com

INSTALLION DIMENSION WITH TRIM FLANE X ROOVE D E A) Constant Pressure Trim WITH CONSTANT PRESSURE TRIM SIZE 80 00 50 200 A 279 32 33 350 B 457 464 486 527 C 434 434 434 443 D 27 40 73 204 E 20 29 234 269 F 275 29 37 395 Unit : mm WITH VARIABLE PRESSURE TRIM SIZE 80 00 50 200 A 279 32 33 350 B 482 488 50 55 C 588 588 588 597 D 27 40 73 204 E 20 29 234 269 F 275 29 37 395 F C F C A B D E B) Variable Pressure Trim Unit : mm A B www.shieldglobal.com 6

INSTALLION DIMENSION WITH TRIM ROOVE X ROOVE D E A) Constant Pressure Trim WITH CONSTANT PRESSURE TRIM SIZE 80 00 50 200 A 279 32 33 350 B 457 464 486 527 C 434 434 434 443 D 27 40 73 204 E 20 29 234 269 F 280 300 324 405 Unit : mm F C A B D E B) Variable Pressure Trim WITH VARIABLE PRESSURE TRIM SIZE 80 00 50 200 A 279 32 33 350 B 482 488 50 55 C 588 588 588 597 D 27 40 73 204 E 20 29 234 269 F 280 300 324 405 Unit : mm C F A B 62 www.shieldglobal.com