Similar documents
DTS Light fittings for explosive atmospheres

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Ex LED light fittings

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

Operating Instructions

XLFE-4/1. Borosilicate glass globe

Dräger Polytron 5720 IR Toxic Gas Detection

Certificate of Compliance

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Integrated Solutions Low Voltage Systems

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

Certificate of Compliance

Illumination unit For sight glass level indicator Model LGI

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

INSTRUCTION MANUAL (ATEX / IECEx)

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 5720 IR Detection of carbon dioxide

INSTRUCTION & SERVICE MANUAL

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

INTRINSICALLY SAFE LIGHTING RANGE

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Industrial Signalling

Telephony & Communication

Dräger Polytron 8720 IR Detection of carbon dioxide

standards: standards:

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

DB4 Range - SPEAKERS - Up to 25 Watts

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Explosion-proof Immersion Heater Type D-8660

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Industrial & Hazardous Area Electrical Equipment

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Helyum. Feam Product Brochure LOCATION CERTIFICATES REFERENCES. Milan / ITALY ATEX, IECEX, EX GOST, INMETRO, NEC500-5

Beacons, Lights & Strobes

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Hazardous Area Portable Fan Heater The Bulldog

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

High bay LED lighting fixture

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

EVLPF Series Compact Fluorescent

HAZARDOUS AREA SOLUTIONS

Hazardous Area Signalling

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Hazardous Area Portable Fan Heater The Bulldog

Dräger Flame 2500 (IR3) Flame Detection

Certification Supplement Manual

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Manual Power relay SR853

HAZARDOUS AREAS. Ex APPROVED EXPLOSION-PROOF PRODUCTS. technor.com

PRODUCT NEWS FLASHING BEACONS FOR RUGGED CONDITIONS IN HAZARDOUS AREAS NEW FX15 SERIES OF FLASHING SIGNAL LIGHTS FOR USE IN EX ZONE 1/2 AND 21/22

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Hazardous Area Portable Fan Heater The Bulldog

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Champ-Pak Wall Pack Luminares

Dräger Flame 2100 (UV) Flame Detection

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Dräger Polytron 8100 EC Detection of toxic gases and vapors

OPTIBAR DP 7060 Supplementary Instructions

BC9700 series High Power LED Explosion Proof Light

ELECTRICAL EX EQUIPMENT

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

Transcription:

PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres

LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light fittings XFFL Range - XFF Range - Fluorescent Tubular glass light fitting for All components mounted on sliding gear tray for easy installation and maintenance Available in glass for chemical environment and corrosive atmospheres Including accessories (cable gland, plug & fixing brackets) Supplied with offshore grade paint II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 12W, 19W, 25W, 31W, 56W, 71W 100-240Vac 50/60Hz XFP Range - Fluorescent with automatic switch off - module with diffuser II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 100-240Vac 50/60Hz 12-110Vdc XEL BAES Range - Self-contained Battery 3h - XFF EM (220-240Vac/Vdc 50/60Hz) II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 100-240Vac 50/60Hz 110Vdc Battery 3h - XFP EM (220-240Vac/Vdc 50/60Hz) II 2 G, Ex d IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C Db & 230Vac 50/60Hz Battery 3h - XFP EM (220-240Vac/Vdc 50/60Hz) Weatherproof polycarbonate tubular light fitting for industrial application FFL Range - FF Range - Fluorescent Ingress protection IP66 ideal for wash down areas All components mounted on a removable gear tray which gives easy access for installation & maintenance Tubular shape to avoid waste accumulation Including accessories (cable gland & fixing brackets) Possibility to retro-fit gear tray into existing fixtures mounted with T8 lamps. IP66, -20 C to +55 C 12W, 19W, 25W, 31W, 56W, 71W 100-254Vac 50-60Hz IEC 62262: IK09 - module with diffuser IP66, -20 C to +55 C 100-254Vac 50-60Hz Battery 3h - self test - FF EMB IEC 62262: IK09

PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Floodlights, beacons, warnings & wellglass XLF Range - XSF / XQF / XEF Range Floodlight fitting for & Industrial applications Integrated junction box Flat or pole mounting Including cable gland Supplied with offshore grade paint II 2 G, Ex de IIB T6 Gb for -20 C to +40 C or Ex de IIB T5 Gb for -20 C to +55 C or Ex de IIB T4 Gb for -20 C to +60 C II 2 D, Ex tb IIIC T85 C Db IP66 for -20 C to +40 C or Ex tb IIIC T100 C Db IP66 for -20 C to +55 C or Ex tb IIIC T135 C Db IP66 for -20 C to +60 C 105W 100-277Vac (+/- 10%) 50/60Hz Operating life > 50,000h (according to ambient temperature) IEC 62262: IK09 More than 7800 lumens output with narrow & wide beam II 2 G, Ex de IIB T3 or T4 or T5 Gb for -20 C to +40 C, Ex de IIB T4 or T3 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T100 C or T135 C or T200 C Db IP66 for -20 C to +40 C, Ex tb IIIC T200 C or T135 C Db & HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz Flat or pole mounting SF / QF / EF Range Industrial applications Wellglass, beacon & warning light for industrial application & zones 2 & 22 - Wellglass Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge lamp according to models - Beacon & warning light Static, halogen or flashing xenon versions available Supplied with lamp installed Including accessories (cable gland & plug) EVH, EVX Range - Wellglass II 2 GD, Ex d IIC T5 to T3 Gb, Ex tb IIIC T95 C to T164 C & HP Sodium: 70W, 150W, 250W, 400W Metal Halide: 150W, 250W, 400W Halogen: 70W, 140W, 250W 230Vac 50Hz Four 3/4 NPT entries - fitted with 2 plugs IP66, -20 C to +55 C HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz XFB / XFL / FB / FL Range - Beacon & warning light Flat or pole mounting II 3 G, Ex na IIC T5 Gc for -20 C to + 60 C II 3 D, Ex tc IIIC T100 C Dc & IP6X for -20 C to + 60 C Halogen 28W, 6W Xenon 30 Joules Halogen 230Vac/Vdc 50/60Hz 220-240Vac 50/60Hz Xenon Flash 230Vac 50/60Hz Cable gland, plug & lamp

LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Linear light fittings EVS Range - Fluorescent EVNL Range - Linear light fitting for all zones & Industrial applications Double central locking for ingress protection Automatic switch off upon opening for safe maintenance All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland & fixing brackets) II 2 G, Ex de IIC T4 Gb for -40 C to +60 C or Ex de IIC T5 Gb for -40 C to +35 C II 2 D, Ex tb IIIC T85 C Db & IP66 for -40 C to +60 C EVN Range - Fluorescent 108 to 254V ac or dc Battery 3h - EVS EM Battery 3h with automatic test and blackstart capabilities - EVS EMA II 3 G, Ex na IIC T5 for -40 C to +25 C, T4 for -40 C to +60 C Gc II 3 D, Ex tc IIIC T65 C for -40 C to +35 C or T85 C for -40 C to +60 C Dc Zones 2 & 22 EVDL Range - 12.6W, 19W, 25W, 31W, 56W, 71W 100-254Vac 50-60Hz - module with diffuser II 3 G, Ex na IIC T4 Gc for -40 C to +40 C, Ex na IIC T3 Gc for -40 C to +60 C II 3 D, Ex tc IIIC T65 C Dc IP66 for -40 C to +40 C, Ex tc IIIC T85 C Dc & IP66 for -40 C to +60 C Zones 2 & 22 108-254Vac or dc Battery 3h - self test - EVN EMB II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 21 & 22 12W, 19W, 25W, 31W, 56W, 71W 100-240Vac 50-60Hz - module with diffuser EVD Range - Fluorescent EVT Range - Fluorescent Industrial applications EVTL Range - Industrial applications II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 2, & 22 220-240Vac/Vdc 50-60Hz Battery 3h - self test - EVD EMB 108-254Vac or dc 50-60Hz Battery 3h - self test - EVT EMB 12.6W, 19W, 25W, 31W, 56W, 71W 100-254Vac 50-60Hz - module with diffuser

PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Recessed light fittings & es and control stations ESB Range - Fluorescent Recessed lighting fitting for zones 1 & 2 Steel housing and body powder paint coated 6mm clear toughened glass panel Including accessories (cable gland) II 2 G, Ex de IIC T4 Gb for -40 C to +60 C Zones 1 & 2 108-254Vac or dc 50/60Hz Battery 3h - ESB EM GUV Range - Aluminum XBL Range - Polyester XBI Range - Stainless steel 316L II 2 G IEC 60529: IP56 Zones 1 & 2 3 or 4x entries 3/4 NPT 1 NPT Stainless steel screw ISO entries and threads Stainless steel captive screws Control station ISO entries and threads Stainless steel captive screws Control station EFDC, SRC, XMC Range - Aluminum XB Range - Aluminum XB100 Range - Polyester II 2 G IEC 60529: IP56 Zones 1 & 2 2x entries 3/4 NPT fitted with one plug Stainless steel screw Control station ISO entries and threads Stainless steel captive screws Control station 4x M20 entries - fitted with 4 cable glands & 1 plug, for armored & non armored cable

LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Custom-built control panels One need, one control panel 01 01 Custom-built control panel 02 EJ Range control panel About DTS DTS is part of the ABB group and provides a complete range of explosion proof lighting, emergency lighting, enclosures, junction boxes and control panels. Our DTS range covers all zones of potential explosion gas & dust atmospheres and is compliant with most stringent national, European and international regulations including IECEx and ATEX standards, making it possible to be used in a wide variety of industries across most of the world. Our value commitment DTS is committed to helping you meet the challenges of corrosion prevention with electrical solutions, services and systems that deliver value. DTS helps to make your life easier by the practicality of its designs by providing effective advice and by being responsive to your need. Approvals / Characteristics DTS control panels are designed, manufactured and tested according to the ATEX protection type Ex d. (Ex d type of protection: Flameproof enclosure) 02 They can be composed of a wide variety of standard components which are switches, contactors and relays for instance. These components can be mounted into explosion proof enclosures built to keep internal explosions from igniting the surrounding atmosphere.

PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Control panel & es for zones 1, 2, 21 & 22 01 ABB DTS 4 step process for creating a custom-built panel 01 Design 02 Stock 02 Drill 04 Assemble 01 EJB Cast aluminum custom-built control panels for Robust construction Wide variety of sizes Large choice of electrical components Customised to user s specification Custom-built control panels DTS Ex d control panels are constructed and tested according to ATEX/IECEx protection type Ex d. Available with a wide variety of components such as switches, contactors and relays, which can be mounted into flameproof enclosures constructed to keep internal explosions from igniting the surrounding atmosphere. Ex d control panels are usually custom-built in cooperation with the customer to suit their specific application requirements. EJ Range - Cast Aluminum Robust construction Wide variety of sizes Options: Boxes provided with load-break switch: Visible breaking Switch off and on under load and provide safety cut off XBL Range - Polyester XBI Range - Stainless steel 316L XB Range - Aluminum 2x entries 3/4 NPT fitted with one plug Stainless steel screw ISO entries and threads Stainless steel captive screws 4x M20 entries - fitted with 4 cable glands & 1 plug, for armored & non armored cable

www.abb.com new.abb.com/low-voltage/hazardous YouTube Channel Copyright 2017 ABB. All rights reserved. Specifications subject to change without notice. 17TC001025B0204.01.08.2017