16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

Similar documents
16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

16LJ Single-Effect Hot Water-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Guide Specifications

16TJ Single-Effect Steam-Fired Absorption Chillers

Product Data. Features/Benefits. 16TJ Single-Effect, Steam Hermetic Absorption Liquid Chiller. 100 to 700 Nominal Tons

16NK Double-Effect Steam-Fired Absorption Chillers

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

DOUBLE EFFECT ABSORPTION CHILLERS

16TJ Single-Effect Steam-Fired Absorption Chillers

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SYSTEM DESIGN REQUIREMENTS

DOUBLE EFFECT ABSORPTION CHILLER /HEATER MG MODEL 1

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Water-Cooled Dual Compressor Screw Chiller

Technical Catalog SAB-LW Series Single Effect Double Lift Hot Water Driven Absorption Chiller 65 to 1,300 Nominal Tons (229 to 4,571 kw)

MAC-A R410A Series Air cooled Modular Chiller

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

SECTION ROTARY-SCREW WATER CHILLERS

MODELS LIST. Nominal Capacity RT

Double Effect Exhaust Gas Driven Absorption Machine

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

Gas-Fired Double-Effect Chiller-Heater

AQUASNAP JUNIOR 30RHV

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

.2 Section Waste Management and Disposal.

Specifications in the catalogue are subject to change without notice. AR-1012 Printed in Korea

FEATURS HYUNDAI CLIMATE CONTROL CO., LTD.

WFC-M Series Installation. WFC- M Series. Hot Water Fired single Effect Absorption Chiller. Installation WFC-M100 Version 1.0 (Original/Document)

MACH N-407 Heat Pump Air-Cooled Chiller

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Hitachi Centrifugal Chillers

Technical Catalog. SAB-HW Series Hot Water Driven Absorption Chiller 15 to 1000 Nominal Tons (52 to 3516 kw) ISO 9001 ISO CHP Solution Inc.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

MAC N-407 Air-Cooled Chiller

Screw Water Cooled Chiller SCW210

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

RNC Series SCFM Global Air Treatment

Page 1 of Relevant Provincial Jurisdictional legislation.

Absorption Chiller Heat Pump

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

HT V2 HT Split

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Scroll Water Cooled Chiller

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Product Data. Features/Benefits. 16JB Steam/Hot Water Single Effect, Hermetic Absorption Liquid Chiller 50/60 Hz

Call us today! (800)

Product Data. Features/Benefits. 16JT Double-Effect Hermetic. Absorption Liquid Chillers Provide. With Product Integrated Controls (PIC)

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

30RH B Nominal cooling capacity kw Nominal heating capacity kw

High Efficiency Commercial Gas Water Heaters

Air Cooled Scroll Chiller / Heat Pump

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

TRIDENT GS SERIES Central Chiller

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Call us today! (800)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

General Catalogue. FORM SSI - G.C (94)

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Water-cooled chillers with High Speed Centrifugal Compressors

ERACS.C-N Higher efficiency air-cooled screw pump

DIVISION FINNED WATER-TUBE WATER HEATERS

RNC Series SCFM Global Air Treatment

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Chapter-8 Capacity Control of Refrigeration Systems

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Installation, Operation and Maintenance Manual

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

TOSHIBA AIR CONDITIONING

30GT FLOTRONIC AIR-COOLED CHILLERS

Transcription:

Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION GB/T-191-2 to ISO91/2 16TJ 11-53 Nominal cooling capacity 352-2461 kw The Carrier Corporation has more than 1 years experience in providing HVAC systems and equipment around the world. Sanyo is a leading manufacturer in the field of highefficiency absorption chillers. Carrier-Sanyo absorption chillers, produced by Sanyo for Carrier, provide a unique choice of models for all absorption chiller applications. Features The Carrier-Sanyo 16TJ single-effect absorption chillers are designed for cooling applications where low-pressure steam is available as waste heat. They can tie into district steam systems. Carrier-Sanyo absorption chillers allow diversification of critical cooling requirements. Critical cooling loads are met with minimal electrical power input. They allow smaller emergency generators compared to an electrical driven chiller. The units are ozone-safe and CFC-free. Cooling requirements are met without chlorine-based refrigerants. They reduce the contribution to global warming and minimize the global impact by greatly reducing electricity consumption and production of greenhouse gases. The solution inhibitor has no impact on the environment. An absorption chiller does not utilize a large motorcompressor, and this leads to quiet, vibration-free operation. The use of high-efficiency heat transfer surfaces has reduced the space required for installation of the absorption chiller, resulting in a smaller footprint. Carrier-Sanyo is the industry leader in compact absorption units.

Nomenclature 16TJ - 11 Capacity code Unit type: Single-effect, steam-fired absorption chillers Component identification Legend 1. Condenser 2. Steam inlet 3. Generator 4. Chilled-water outlet 5. Control panel 6. Evaporator 7. Chilled-water inlet 8. inlet 9. Heat exchanger 1. Heat reclaimer 11. Absorber

The absorption cycle The absorption cooling cycle, like the mechanical vapour compression refrigeration cycle, utilizes the latent heat of evaporation of a refrigerant to remove heat from the entering chilled water. Vapour compression refrigeration systems use a chlorine-based refrigerant and a compressor to transport the refrigerant vapour to be condensed in the condenser. The absorption cycle, however, uses water as the refrigerant and an absorbent lithium bromide solution to absorb the vaporized refrigerant. Heat is then applied to the solution to release the refrigerant vapour from the absorbent. The refrigerant vapour is then condensed in the condenser. The basic single-effect absorption cycle (see Figure 1) includes generator, condenser, evaporator and absorber with refrigerant (liquid) and lithium bromide as the working solutions. The generator utilizes a heat source (burner, steam or hot water) to vaporize the diluted lithium bromide solution. The water vapour that is released travels to the condenser where it is condensed back into a liquid, transferring the heat to the cooling tower water. Once condensed, the liquid refrigerant is distributed over the evaporator tubes, removing the heat from the chilled water and vaporizing the liquid refrigerant. The concentrated lithium bromide solution from the generator passes into the absorber, absorbs the refrigerant vapour solution from the evaporator and dilutes itself. The diluted lithium bromide solution is then pumped back to the generator where the cycle is started again. Figure 1 - Simplified absorption cycle Legend 1. Refrigerant vapour 2. Condenser 3. Generator 4. 5. Liquid refrigerant 6. Concentrated solution 7. Heat source 8. 9. 1. Evaporator 11. Absorber 12. Absorbent pump Cooling cycle schematic Heat sink 1.7 Heat 1. Temperature of refrigerant ( C) 6 5 4 3 2 1 8 1 1 8 B A 5 1 2 3 4 5 6 7 8 9 1 Temperature of absorbent ( C) % C 4% 45% 5% 55% D 6% 65% 7% 5 4 3 2 Pressure (kpa) 12 13 14 15 16 17 18 Legend 1. Generator 2. 3. Condenser 4. Hot water 5. Evaporator 6. 7. Absorber 8. Refrigerant pump 9. Absorbent pump 1. Heat exchanger 11. 12. Concentrated solution 13. Diluted solution 14. Liquid solution 15. Refrigerant vapour 16. 17. 18. Hot water

Chiller features Expert self-diagnosis function The expert function is provided to monitor operating conditions, predict chiller information and maintain stable operation. Predictive maintenance information Graph 1 - Fouling of heat transfer tubes in cooling water system Fouling factor Maintenance zone Notice line Cooling load factor (%) Normal line Graph 2 - Trend of absorbent concentration Abnormal stop zone Maintenance line Normal line Carrier-Sanyo control system The Carrier-Sanyo control system surpasses other proportional only control systems available today. The digital PID (proportional plus integral plus derivative) control maximizes unit performance by maintaining a ±.5 K variance in leaving chilled-water temperature from the setpoint. Proportional controls can typically only maintain a ±1 K variance from the setpoint. The controller s innovative design also incorporates the ability to start and stop the system chilled/hot and cooling water pumps. During shutdown these pumps are sequenced to ensure a complete dilution cycle. The leaving chilled-water temperature is measured every five seconds and steam input is changed according to the gradient of the leaving chilled-water temperature curve. System temperatures, setpoints, and operational records are displayed along with indicator lights for the chiller and pumps. The Carrier-Sanyo control system offers its users selfdiagnostics by constantly monitoring the chiller status and will automatically shut the chiller down should a fault occur. The cause of shutdown will be retained in the memory and can be displayed for immediate operator review. The controller s memory will also retain and display the cause of the last three system fault conditions. This method of retaining fault conditions is extremely useful for maintaining an accurate record of unit performance and fault history. Display and control board Figure 2 - Indication lights Concentrated indicator Maintenance zone at cooling water 31 C Maintenance zone at cooling water 27 C Normal line at cooling water 31 C STOP RUN CHILLER HEATER #ABS PUMP #2ABS PUMP Normal line at cooling water 27 C REF PUMP PURGE PUMP SET BACK REMOTE STAND BY Cooling load factor (%) DILUTION SAFETY CIRCUIT BUZZER STOP LOCAL CHILLER ALARM STOP OPERATION RUN POWER Graph 3 - Vacuum condition monitoring Pressure increase indicator at storage tank Notice zone Normal zone Storage ratio (%) Maintenance zone 1 2 3 4 5 Legend Name LED colour 1. Operation indication light Green 2. Stop indication light Orange 3. Alarm indication light Red 4. Remote/local select button with LED Green 5. Operation select button with LED Green 6. Data display 7 segment LED (red) 7. Stand-by indication light Green 8. Dilution indication light Green 9. Safety circuit indication light Green 1. Power indication light Orange GL*. Purge indication light Green 43P*. Purge pump on-off switch 43ES*. Emergency stop switch * On the control panel door, see p.16 Legend 1. Storage tank 2. Diluted solution 3. Purge nozzle 4. Pd cell 5. Pressure sensor

Fast digital PID control The introduction of new digital PID control to the J-model stabilizes the chilled/hot-water temperature with higher accuracy than the previous E-model. It quickly responds to the load fluctuation and supplies stable chilled/hot-water temperature. It is suitable for air-conditioning intelligent buildings which require sophisticated control. Saving energy with the inverter (option) Balancing the load and flow rate with the absorbent pump s inverter control enables efficient and energy-saving operation. As a result, it reduces input energy and electric power consumption. Running cost is decreased by 5% compared to non-inverter control. Graph 4 - Running cost curve Graph 5 - Steam valve opening control Temperature ( C) Setting 7 C Variable (5-3 minutes) Steam consumption Example 15 minutes 3 minutes Hot water control valve opening ratio entering temp. Chilled-water entering temp. Chilled-water leaving temp. Steam consumption (%) Steam control opening ratio (%) Time (minutes) Energy consumption ratio (%) Non-inverter control Inverter control Expansion of safe operating zone This ensures quick response to rapid changes and maintains stable operation. The safe operating zone is between 19 C and 34 C cooling water temperature (for a nominal cooling water entering temperature of 32 C) Graph 6 - Safe operating zone chart Cooling load factor (%) Notes: 1. Chilled-water leaving temperature 7 C constant 2. entering temperature: Load factor (%) 1 32 5 27 3 25 Temperature ( C) Purge system The high-performance purge system maintains the required operating pressure, preserves chiller performance characteristics, minimizes chiller maintenance to one purge operation per season (for year-round operation). Steam valve opening control At the start-up the opening angle of the steam control valve is controlled in three stages, reducing the amount of steam and the time needed to reach the desired level, compared with the previous model. Adjusting the opening speed of the steam control valve at the second and third stage, it is possible to set up the most suitable conditions for the site auxiliary equipment. Maximum input (%) entering temperature ( C) H = 32 C (variable from 2 C to 33 C) Crystallization protection A microprocessor monitors the absorbent concentration. Steam supply is stopped, and the unit is returned to normal operation, when the concentration is over a certain limit, to prevent the crystallization of absorbent.

Technical data Single effect steam-fired absorption chillers 16TJ 11 12 13 14 21 22 23 24 31 32 41 42 51 52 53 Cooling capacity kw 352 422 527 633 738 844 985 1125 1266 147 1582 1758 1969 2215 2461 Chilled-water system* Flow rate l/s 151 182 227 273 317 364 425 483 544 66 681 758 847 953 161 Pressure drop kpa 49 51 63 67 59 63 4 44 47 51 41 44 38 51 67 Connection (ANSI) inch 4 4 4 4 5 5 6 6 6 6 8 8 8 8 8 Retention volume m3.12.13.15.17.22.24.28.3.34.36.46.48.65.71.77 system** Flow rate l/s 81.8 98.1 123 147 172 196 229 262 817 98 122 1136 1272 1431 1589 Pressure drop kpa 33 36 31 36 31 34 64 69 54 56 59 63 41 54 7 Connection (ANSI) inch 5 5 5 5 6 6 8 8 8 8 1 1 12 12 12 Retention volume m3.35.38.43.48.6.65.73.79.99 1.6 1.25 1.35 2.3 2.18 2.32 Steam system Saturated steam 1 kpa Consumption kg/h 78 94 117 141 164 188 219 25 281 312 351 39 437 492 546 Steam inlet inch 5 5 5 5 6 6 8 8 8 8 8 8 1 1 1 Drain outlet inch 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 Control valve inch 2 2 2-1/2 2-1/2 2-1/2 3 3 4 4 4 4 4 4 5 5 Shutoff valve inch 2 2 2-1/2 2-1/2 2-1/2 3 3 4 4 4 4 4 4 5 5 Length (L) mm 268 2681 369 369 377 377 485 485 491 491 496 496 55 559 69 Width (W) mm 1295 1295 1295 1295 1455 1455 1455 1455 1515 1515 1615 1615 195 195 195 Height (H) mm 2215 2215 2215 2215 235 235 235 235 262 262 287 287 32 32 32 Tube removal space mm 24 241 34 34 34 34 45 45 45 45 45 45 46 52 57 Operating weight kg 38 4 49 51 62 65 76 8 98 12 118 123 169 183 196 Max. shipping weight kg 33 35 43 45 54 56 66 69 85 88 11 14 142 154 165 Shipping method One-piece Power supply 4 V-3 ph-5 Hz Apparent power kva 4.3 4.3 4.3 4.3 6. 6. 6.1 6.1 7.6 7.6 7.6 7.6 7.6 7.6 7.6 Total electric current A 6.5 6.5 6.5 6.5 9. 9. 9.1 9.1 11.3 11.3 11.3 11.3 11.3 11.3 11.3 No.1 absorbent pump kw 1.1 1.1 1.1 1.1 2.2 2.2 2.2 2.2 3. 3. 3. 3. 3. 3. 3. A 3.3 3.3 3.3 3.3 5.8 5.8 5.8 5.8 8. 8. 8. 8. 8. 8. 8. Refrigerant pump kw.2.2.2.2.2.2.3.3.3.3.3.3.3.3.3 A 1.25 1.25 1.25 1.25 1.25 1.25 1.35 1.35 1.35 1.35 1.35 1.35 1.35 1.35 1.35 Purge pump kw.4.4.4.4.4.4.4.4.4.4.4.4.4.4.4 A 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 Pd cell heater W 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 Control circuit W 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Legend * In accordance with ARI 56-2 12.2 > 6.7 C (Fouling factor =.176 m2 K/kW) 29.4 >38.4 C (Fouling factor =.44 m2 K/kW) 95. >86. C (Fouling factor =.176 m2 K/kW) Note: For selection outside ARI operating conditions please contact Carrier.

Scope of supply 1. Standards met The units comply with the following standards: ARI 56-2 89/392/EEC (machine directive) 73/23/EEC (low-voltage directive) 89/336/EEC (electromagnetic compatibility directive) 97/23/EC (pressure equipment directive) 2. Absorption chiller, comprising: 1. Lower shell Evaporator and refrigerant dispersion tray Absorber and absorbent dispersion tray Eliminators Bases 2. Upper shell Generator Condenser Low temperature (LT) generator Eliminators Rupture disk mounting flange 3. Heat exchangers 4. Pumps Absorbent pump with isolating valves Refrigerant pump with isolating valves Purge pump 5. Purge unit Purge tank Ejector and liquid trap Piping and various manual valves Palladium cell with heater 3. Factory test 1. Check of external dimensions 2. Hydraulic pressure test of water headers Test pressure is 1.5 times of maximum working pressure 3. Vacuum-side leak test 4. Electric insulation resistance test 5. Dielectric breakdown test 6. Function test of electric circuit and safety devices 4. Scope of supply of the purchaser 1. Building and foundations 2. External chilled water, cooling water and steam piping work including various safety valves, isolation valves, mating flanges, gaskets, bolts and nuts, etc. 3. External wiring and piping for the chillers including necessary parts 4. Insulation for the chillers including necessary parts. 5. Finish painting of the chillers (if needed) 6. entering temperature control device 7. treatment device 8. Various temperature/pressure gauges for steam and water lines. 9. Cooling tower(s), chilled-water pump(s) and steam control valve and steam shut-off valve 1. Electric power supply (as specified) 11. Supply of chilled water, cooling water, steam and air* at rated conditions 12. Maintenance of the chiller 13. Necessary tools, labour and materials for installation and site test operation 14. Any other item not specifically mentioned in the scope of supply * If pneumatic hot-water valve control is used 6. Control panel Controller with data display LEDs and operation buttons Inverter for absorbent pump (option) Circuit breaker Transformer Relays and terminal blocks Purge pump operation switch 7. Locally mounted parts Temperature sensors Chilled-water flow switch Generator pressure switch 8. Interconnecting piping and wiring Refrigerant and absorbent piping Internal power and control wiring 9. Initial charge Absorbent (lithium bromide) Refrigerant (water) Inhibitor (lithium molybdate) 1. Painting Main unit: Rust-preventive paint Control panel: Finish paint 11. Accessories Operation manual: One set Washer (for fixing foundation bolts): One set Gasket and sealant for rupture disk: One set

Scope of order Item Standard Option Temperature Entering: 12.2 C, leaving: 5 C through 12 C Leaving: 6.7 C, temperature difference 3 K through 1 K Flow rate.43 l/s x kw. Changes depending on chilled water temperature difference (min 5%) Max.working pressure 134 kpa...............................................154 kpa, 268 kpa Hydraulic test pressure Max. working pressure x 1.5...............................Max. working pressure x 1.5 Fouling factor.18 m2 K/kW. Max..18 m2 K/kW Tube material Copper tube............................................cu Ni tube Water quality Refer to JRA-GL2E-1994.................................No option Structure of water header Hinged type and epoxy treated.............................no option Manufacturing standard of water header Flanged ANSI...........................................No option Temperature Entering: 29.4 C Leaving: 38.4 C, entering: 2 C through 33 C Flow rate.65 l/s kw. Within the water fl ow rare range of each model Max. working pressure 784 kpa. Max. 196 kpa...................................154 kpa, 268 kpa Hydraulic test pressure Max. working pressure x 1.5 Fouling factor.44 m2 K/kW. Max..18 m2 K/kW Tube material Copper tube............................................cu Ni tube Water quality Refer to JRA-GL2E-1994.................................No option Structure of water header Hinged type and epoxy treated.............................no option Manufacturing standard of water header Flanged ANSI...........................................No option Steam Supply pressure 1 kpa, 5 kpa through 1 kpa, max. 5 K superheat Specific steam consumption 2.22 kg/h/kw. Changes depend on the specifications. Max. working pressure 146 kpa................................................no option Hydraulic test pressure Max. working pressure x 1.5...............................No option Tube material 9/1 Copper nickel tube....................................no option Steam quality Refer to JIS-B-8223......................................No option Manufacturing standard of water header Flanged ANSI...........................................No option Electricity Power supply 4 V - 3 phase - 5 Hz...................................Contact the Carrier-Sanyo representative (Voltage control within ±1%, frequency control within ±5%) Shipment One section............................................multi shipment Control Safety functions Refrigerant temperature................................... flow switch Chilled-water freeze protection Chilled-water flow switch temperature HT generator temperature HT generator pressure HT generator solution level Exhaust gas temperature Crystallization protection Motor protection Capacity control Digital PID control by chilled-water temperature................inverter control of #1 absorbent pump Parts Selected by Carrier-Sanyo.................................No option Control panel Painting Munsell 5Y-7/1..........................................No option Indication lights Operation..............................................No option Stop Alarm Display LED...................................................No option External terminals Operation indication......................................no option (Volt-free normally open contact) Stop indication Alarm indication Answer back indication Cooling mode indication Structure Indoor type.............................................no option Parts Selected by Carrier-Sanyo.................................No option Electrical wiring and piping Wire: 6 V polyvinyl grade................................no option chloride-insulated wires Pipe: Plicatube..........................................No option (flexible metal conduits) Insulation condition Place Indoor.................................................No option Ambient temperature 5 C through 4 C........................................No option Ambient humidity Relative humidity: max 9% at 45 C.........................No option Atomosphere Be sure the following are not present.........................no option - Corrosive gas - Explosive gas - Poisonous gas

Pass Arrangement 16TJ Evaporator Absorber Condenser Minimum Standard Maximum Minimum Standard Maximum Minimum Standard Maximum 11 2 4 6 2 3 4 1 2 2 12 2 4 6 2 3 4 1 2 2 13 2 3 4 2 2 3 1 1 2 14 2 3 4 2 2 3 1 1 2 21 2 3 4 2 2 3 1 1 2 22 2 3 4 2 2 3 1 1 2 23 2 2 4 2 2 3 1 1 2 24 2 2 4 2 2 3 1 1 2 31 2 2 4 2 2 3 1 1 2 32 2 2 4 2 2 3 1 1 2 41 2 2 4 2 2 3 1 1 2 42 2 2 4 2 2 3 1 1 2 51 2 2 4 2 2 3 1 1 2 52 2 2 4 2 2 3 1 1 2 53 2 2 4 2 2 3 1 1 2 NOTE: The drawings shown on the following pages are for the standard number of passes. For applications outside the nominal conditions of this catalogue, computer selection software can automatically select the most appropriate number of passes.

Dimensional drawings, mm 16TJ 11 through 16TJ 12 23 129 635 1896 281 2226 NOTES 1. Dimensions (L), (W), (H) are for a standard machine. The dimensions are changed by parts added. 2. indicates the position of anchor bolts. 3. Clearance space must be available at the front and rear of the chiller. 4. All external water piping must be provided with welded ANSI 15 LB flanges by the customer. 5. indicates the position of the power supply connection on the control panel (diameter 35 mm) 6. Installation clearance: Ends 1 mm Top 2 mm Others 5 mm 8 17 145 Wire connection Ø35 hole R6 24 Tube removal 78 Steam inlet (5 inch) outlet (5 inch) 2125 1995 1295(W) 2193 19 Rupture disk (2 inch) 268(L) 285 outlet (4 inch) inlet (4 inch) 1263 923 141 Drain outlet (1-1/2 inch) 2215(H) 785 inlet (5 inch) 595 3 91 882 Steam inlet 19 25 Drain outlet 2 18 inlet in/out outlet 276 231 16TJ 13 through 16TJ 14 33 185 635 2916 2987 3146 8 78 17 145 Wire connection Ø35 hole R6 Tube removal Steam inlet (5 inch) outlet (5 inch) 2125 1995 1295(W) 2193 19 Rupture disk (2 inch) 369(L) 285 outlet (4 inch) inlet (4 inch) inlet (5 inch) 1263 923 595 141 3 Drain outlet (1-1/2 inch) 2215(H) 785 91 882 19 25 2 18 inlet Steam inlet Drain outlet outlet inlet outlet 396 3116 3271 NOTE: Dimensions are for guidance only. Always refer to the certified drawings supplied upon request when designing an installation.

16TJ 21 through 16TJ 22 NOTES 1. Dimensions (L), (W), (H) are for a standard machine. The dimensions are changed by parts added. 2. indicates the position of anchor bolts. 3. Clearance space must be available at the front and rear of the chiller. 4. All external water piping must be provided with welded ANSI 15 LB flanges by the customer. 5. indicates the position of the power supply connection on the control panel (diameter 35 mm) 6. Installation clearance: Ends 1 mm Top 2 mm Others 5 mm 355 21 355 21 71 2866 2962 3141 1 27 R6 Wire connection Ø35 hole 22 125 Tube removal 926 Steam inlet (6 inch) outlet (6 inch) 2295 2135 1455(W) 2328 19 Rupture disk (2 inch) 377(L) 2255 outlet (5 inch) inlet (5 inch) 1346 16 65 151 Drain outlet (1-1/2 inch) 235 (H) 835 inlet (6 inch) 3 19 165 25 285 237 22 Steam inlet Drain outlet inlet inlet outlet outlet 384 313 16TJ 23 through 16TJ 24 116 3312 3886 4189 1 926 27 Wire connection Ø35 hole 125 22 R6 Tube removal 1455(W) Steam inlet (6 inch) outlet (6 inch) 2295 2135 2328 19 Rupture disk (4 inch) 485(L) 2255 outlet (5 inch) inlet (5 inch) inlet (6 inch) 1333 119 65 151 3 Drain outlet (1-1/2 inch) 235 (H) 835 19 165 25 285 25 22 inlet Steam inlet Drain outlet outlet in/out 414 4354 NOTE: Dimensions are for guidance only. Always refer to the certified drawings supplied upon request when designing an installation.

16TJ 31 through 16TJ 32 458 26 1135 3315 3836 4164 NOTES 1. Dimensions (L), (W), (H) are for a standard machine. The dimensions are changed by parts added. 2. indicates the position of anchor bolts. 3. Clearance space must be available at the front and rear of the chiller. 4. All external water piping must be provided with welded ANSI 15 LB flanges by the customer. 5. indicates the position of the power supply connection on the control panel (diameter 35 mm) 6. Installation clearance: Ends 1 mm Top 2 mm Others 5 mm 11 28 15 R6 Wire connection Ø35 hole Tube removal 122 65 Steam inlet (8 inch) outlet (8 inch) 2544 2365 1515(W) 2595 Rupture disk (3 inch) 491(L) 25 outlet (6 inch) inlet (6 inch) inlet (8 inch) 1476 166 611 19 166 3 Drain outlet (2 inch) 262 (H) 815 117 1156 26 Steam inlet 335 Drain outlet in/out 275 27 inlet outlet 415 4354 16TJ 41 through 16TJ 42 468 26 1135 3315 3836 4164 115 136 275 12 Wire connection Ø35 hole 5 R6 Tube removal Steam inlet (1 inch) outlet (1 inch) 285 2595 1615(W) 2844 Rupture disk (3 inch) 496(L) 275 outlet (8 inch) inlet (8 inch) 1613 1142 19 181 Drain outlet (2-1/2 inch) 287 (H) 84 inlet (1 inch) 577 3 1255 1221 275 35 31 269 inlet Steam inlet Drain outlet in/out outlet 415 4329 NOTE: Dimensions are for guidance only. Always refer to the certified drawings supplied upon request when designing an installation.

16TJ 51 through 16TJ 53 NOTES 1. Dimensions (L), (W), (H) are for a standard machine. The dimensions are changed by parts added. 2. indicates the position of anchor bolts. 3. Clearance space must be available at the front and rear of the chiller. 4. All external water piping must be provided with welded ANSI 15 LB flanges by the customer. 5. indicates the position of the power supply connection on the control panel (diameter 35 mm) 6. Installation clearance: Ends 1 mm Top 2 mm Others 5 mm 16 45 2 523 325 13 12 Wire connection Ø35 hole 3272 AB C 141 173 16TJ A B C D E F L 51 376 3836 4136 46 478 4336 55 52 4248 4378 4678 525 4623 4878 559 53 4746 4876 5176 57 5121 5378 69 R6 D Tube removal Steam inlet (1 inch) outlet (12 inch) 3158 2925 195(W) 3139 Rupture disk (3 inch) L 399 outlet (9 inch) inlet (9 inch) inlet (12 inch) 176 117 651 21 Drain outlet 19 (2-1/2 inch) 32 (H) 3 9 171 435 25 37 Steam inlet Drain outlet in/out outlet inlet E F NOTE: Dimensions are for guidance only. Always refer to the certified drawings supplied upon request when designing an installation. 13

Foundation dimensions, mm Figure 3-16TJ-11 through 16TJ-42 Figure 5-16TJ-51 through 16TJ-53 AA BB K C D E F G AA G K E F BB D J C A 15 B A B 15 Figure 4 - Details of weld Nut Weld Washer Base A = 15 mm and more NOTES: 1. The machine base has ø5-mm hole for the anchor bolt. 2. The anchor bolt should be fixed as shown in the detail drawing.washer should be welded to the base (see Fig. 4) 3. There should be a drain channel around the foundation. 4. The floor surface should be made waterproof to facilitate maintenance work. 5. The surface of the foundation should be made flat. 6. Anchor bolts and nuts are to be supplied by customer. Table 1 - Dimensional data 16TJ Weight, kg Dimensions, mm AA + BB AA BB A B C D E F G J K 11 38 19 19 189 -- 175 36 8 15 11 16 9 12 4 2 2 189 -- 175 36 8 15 11 16 9 13 49 245 245 2916 -- 175 36 8 15 11 16 9 14 51 255 255 2916 -- 175 36 8 15 11 16 9 21 62 31 31 2866 -- 2 4 1 15 13 2 11 22 65 325 325 2866 -- 2 4 1 15 13 2 11 23 76 38 38 3886 -- 2 4 1 15 13 2 11 24 8 4 4 3886 -- 2 4 1 15 13 2 11 31 98 49 49 3836 -- 225 45 11 15 14 25 12 32 12 51 51 3836 -- 225 45 11 15 14 25 12 41 118 59 59 3836 -- 225 45 115 15 145 25 125 42 123 615 615 3836 -- 225 45 115 15 145 25 125 51 169 845 845 376 13 19 51 16 18 196 25 17 52 183 915 915 4248 13 19 51 16 18 196 25 17 53 196 98 98 4746 13 19 51 16 18 196 25 17 14

Control panel dimensions, mm 16TJ-11 through16tj-53 A A GL43P 16 43ES Power supply ØA ( ØB) Remote control Ø22 12 7 8 3 Start/stop sequence of auxiliary equipment Start Start signal pump operates pump operates and then cooling tower fan operates Machine operates Operate air conditioners Stop Stop signal Diluted operation starts pump stops and cooling tower fan stops Chilled-water pump stops Chiller stops completely Stop air conditioners 15

Field wiring Figure 6 - Typical electrical field connection diagram - hot water-fired absorption chillers (LJ) REMOTE SIGNAL Chiller can be operated by the following five signal types. (1) Volt-free normally open contact (a) for start & stop (24 V d.c. 1 ma): Wire terminal 324 and 323, connect 17 and 326. (2) Volt-free normally open contact (a) for start (24 V d.c. 1 ma): Wire terminal 324 and 325, connect 17 and 326. Volt-free normally open contact (a) for stop (24 V d.c. 1 ma): Wire terminal 325 and 323. (3) Volt-free normally open contact (a) for start (24 V d.c. 1 ma): Wire terminal 324 and 325, connect 17 and 326. Volt-free normally closed contact (b) for stop (24 V d.c. 1 ma): Wire terminal 325 and 323. (4) Continuous signal of 24 V a.c./d.c. for start & stop (initial setting): Wire terminal 324 and 326 (these terminals are non-polarized) (5) Pulse signal of 24 V a.c./d.c. for start: Wire terminal 324 and 326 (these terminals are non-polarized.) Pulse signal of 24 V a.c./d.c for stop: Wire terminal 325 and 326 (these terminals are non-polarized.) UL: 28 V/46 V - 3 ph - 6 Hz CE: 4 V - 3 ph - 5 Hz CE: OVERVOLTAGE CATEGORY III 24 V d.c. 1 ma CE: OVERVOLTAGE CATEGORY II TO POWER SOURCE CHILLED/HOT-WATER PUMP INTERLOCK COOLING WATER PUMP INTERLOCK Chiller control panel (1) (2) (3) (4) (5) continuous pulse pulse continuous pulse TERMINAL STRIPS ON THE CONTROL PANEL FIELD-SUPPLIED PANEL FIELD-WIRING CONNECTION (1) Provide power supply wiring and earthing Connect wire between chiller control panel and earth on site. The chiller has a circuit beaker. Please connect power supply cable to the terminal block provided. Earthing resistance: Should be determined from local regulations. Earthing cable: annealed copper wire (please use a cable of the same cross section as the power supply cable). TERMINAL STRIPS ON THE CONTROL PANEL PRE-ALARM SIGNAL REMOTE CHECK SIGNAL FOR OPERATION INDICATION FOR STOP INDICATION FOR ALARM INDICATION RUN/STOP SIGNAL FOR CHILLED WATER PUMP RUN/STOP SIGNAL FOR COOLING WATER PUMP RUN/STOP SIGNAL FOR COOLING TOWER FAN FEEDBACK SIGNAL FOR DILUTION INDICATION RUN/STOP SIGNAL FOR VENTILATION FAN FOR COOLING INDICATION FOR HEATING INDICATION FOR ALARM BUZZER

Typical piping diagram 1 2 R P 3 14 5 F HC 4 C P T P T 13 12 P F 11 MV 15 18 19 7 P T P T 16 17 2 6 8 9 1 T Thermometer P Pressure gauge F Flow meter Water pump Strainer Stop valve Shutoff valve Thermostat Legend 1. Main steam piping 2. Reducing valve 3. Air conditioner 4. Chilled-water pump (primary) 5. Chilled-water pump (secondary) 6. Supply header 7. Bypass valve 8. Return header 9. To drain channel 1. pump 11. Check valve 12. Safety valve 13. Steam control valve 14. Steam shutoff valve 15. Blow-down valve 16. Minimum tank capacity 1 m3 17. To boiler 18. Bypass valve 19. Water supply 2. thermostat NOTE: In order to prevent freezing of the chilled water ensure continued operation of the primary and secondary chilled-water pumps during dilution cycle operation of the chillers. General remarks on piping 1. Work outside the area surrounded by this line shall be undertaken at the expense of the owner. 2. For pipe connections and diameters refer to the dimensional drawings and specification tables. 3. Steam pressure at the inlet of the machine cannot exceed 146 kpa. Please refer to the diagram to install a pressure relief valve near the chiller to release pressure above 146 kpa. The relief valve should be piped to the outdoors. 4. Even if a reducing valve is not required, a strainer, pressure gauge and drain trap should be provided for each machine near the steam inlet. 5. The back pressure of the steam drain outlet pipe should be controlled below 19.6 kpa. 6. Determine the location of the chilled and cooling water pumps with due consideration of the pump s hydrostatic head. The machine should not be subject to a pressure larger than 134 kpa at any water headers. 7. minimum entering control has to be supplied (please refer to the Installation Manual). 8. Provide a thermometer and a pressure gauge at the cooling water and chilled water outlet and inlet. 9. Provide an air vent valve in each of the chilled and cooling water lines at a point higher than the header for chilled water and cooling water. 1. Drain pipes from the evaporator and absorber should be piped to the drain channel. 11. Provide a blow-down valve in the cooling water line for water quality control. 12. All external water piping is to be designed for maximum unit water-side pressure (to cover any options used). 13. Be sure to provide a shutoff valve to prevent steam flow into the chiller during shut-down. In case two or more chillers are installed, provide an automatic shutoff valve. 14. Be sure to design the location of the cooling tower to prevent contamination of cooling water by exhaust gas from flues. 15. If required, fit the rupture disk on the chiller according to the rupture disk manual. 16. Separate chilled and cooling water pumps should preferably be provided for each chiller. 17. Provide an expansion tank in the chilled-water line. 18. There should be sufficiently large clearance for easy access to the evaporator, absorber and condenser, to facilitate inspection and cleaning work. 17

Safety considerations Before operating the unit Before operating the unit be sure to read the operation manual carefully. Installation should conform to all applicable local codes and regulations. During the installation Read the installation manual carefully before offloading and installing the unit. All work must be carried out be qualified personnel to prevent injuries and damage to the equipment. Waterproof the unit foundation and provide a drain channel to prevent water damage to the surrounding equipment. Provide adequate space around the unit for maintenance work to ensure safe working conditions. Maintenance In addition to daily inspection periodical maintenance is required. Insufficient or incorrect maintenance may cause fire, electric shock and injuries. Please consult your local service office for further guidance. Avoiding hazardous places Keep the units away from dangerous inflammable substances such as gasoline, thinner and combustible gases, as these may result in a fire.

GB/T-241 to ISO141:1996 Order No. 11614-2, 1.25. Supersedes order No.: New. Manufacturer reserves the right to change any product specifications without notice. Manufacturer: Carrier-Sanyo, Dalian, PR China. Printed on Totally Chlorine Free Paper. Printed in the Netherlands.