ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Similar documents
NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

ASPECT VISION DELIVERED

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

INTRINSICALLY SAFE LIGHTING RANGE

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

D O M E S T I C LED. Lighting C O M M E R C I A L

High bay LED lighting fixture

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Ex LED light fittings

Applications. Standard Materials

ProAir an unrivalled combination of light quality and efficiency

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

Flow LED robust and streamlined

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

BC9700 series High Power LED Explosion Proof Light

INSTRUCTION MANUAL (ATEX / IECEx)

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

TubeLine LED unit Optimised comfort with a linear LED solution

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

Glacial. COB Inground

DTS Light fittings for explosive atmospheres

TubeLine LED unit Optimised comfort with a linear LED solution

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

INSTRUCTION & SERVICE MANUAL

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

PRECISION LIGHTING FOR PRISTINE MOMENTS!

Operating Instructions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Explosion-proof Immersion Heater Type D-8660

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

CoreLine Batten the clear choice for LED

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Enhancing your petrol station with smart lighting

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

2018 PRODUCT CATALOGUE

LMV Series W Low Profile - Medium Base

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Kirium and Sephora wall

LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products

Think LED. Think Philips TradeLED

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Canolux LED. Petrol Station Forecourt Luminaires

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

CoreLine Recessed Spot the clear choice for LED

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

LED Protected Catalogue

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Flow LED robust and streamlined

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design.

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

FreeStreet feel free in your city

ArtLED Gallery and Museum Spotlights

CoreLine Waterproof the clear choice for LED

WE-EF LIGHTING USA QLS400 [R45] SERIES Wall luminaires surface mounted 2018

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Hazardous Area Portable Fan Heater The Bulldog

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

Hazardous Area Portable Fan Heater The Bulldog

ClearAccent - Affordable recessed LED spot

TYPE APPROVAL CERTIFICATE

CoreLine Recessed Spot the clear choice for LED

PRODUCT DATA SHEET ilh8

ATM Lighting sp. z o.o

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Ledinaire Batten Simply great LED

SmartForm top-class lighting in a fresh, appealing design

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

UL HAZARDOUS LOCATIONS SERVICES

standards: standards:

Transcription:

ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or dust are present, the floodlight is highly vibration resistant and can be used for industrial applications. Standard Specification Features Enclosure Entry Termination Installation Control Gear Luminaire Efficacy Ingress Protection Aluminium alloy with epoxy powder finish 2 x M20 cable entries 3 core 6mm² max. conductor with looping Stirrup mounting Electronic driver >100 lm/w IP66 Instant on crisp white light output Colour temperature 5000K (CCT) Highly energy efficient 130,000 maintenance free hours @ 25 C Less power used than HID lamps High ingress protection Low temperature applications to -50 C Surge Protection 20kV Electrical Supply 120-277V AC 50/60Hz

INDUSTRIAL and and MARINE APPLICATIONS Std. Cat No. Power Consumption Delivered Output Ambient C Weight ARRI/06L/LE 60W 5800 lm -50 to +55 13kg ARRI/10L/LE 70W 9710 lm -50 to +55 13kg ARRI/11L/LE 85W 10800 lm -50 to +55 13kg ARRI/15L/LE 125W 15340 lm -50 to +55 13kg Options - Suffix to Catalogue No. /M25 M25 cable entries /DC DC voltage (60W only) 450.8 377.8 132.7 Ø13 79 287.6 357.3 213.5 50.8 Accessories Should be ordered separately Pole mounting bracket assembly Wire guard Anti glare shield Catalogue Order Code Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. November 2014 Rev 2 Chalmit, PO BOX 5575, Glasgow G52 9AP Tel: +44(0) 141 882 5555 Fax: +44(0)141 883 3704 www.chalmit.com info@chalmit.com

ARRAN Ex n LED FLOODLIGHT 1 The Arran LED floodlight range is low energy with an instant on output and 80,000 maintenance free hours to L70 (70% initial lumens). Specifically designed for applications where moisture, dirt or dust are present, the floodlight is highly vibration resistant and can be used in locations where flammable vapours, gases or combustible dusts exist. Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Entry Termination Installation Control Gear Luminaire Efficacy Ingress Protection Surge Protection Electrical Supply Standard Specification Ex na (Non Sparking) Group II Category 3 GD Zone 2 and Zone 22 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079.14 IECEx CSA14.0002 ATEX certificate pending Ex na II Refer to table for T Class & Ambient Aluminium alloy with epoxy powder finish 2 x M20 cable entries 3 core 6mm² max. conductor with looping Stirrup mounting Electronic driver >100 lm/w IP66 20kV 120-277V AC 50/60Hz Features Instant on crisp white light output Colour temperature 5000K (CCT) Highly energy efficient 80,000 maintenance free hours 70% initial lumens Less power used than HID lamps High ingress protection Low temperature applications to -50 C

ATEX CATEGORY 3 ZONE 2 & 22 APPLICATIONS 2 Std. Cat No. Power Consumption Delivered Output TClass Ambient C Weight ARRN/06L/LE 60W 5800 lm ARRN/10L/LE 70W 9710 lm ARRN/11L/LE 85W 10800 lm ARRN/15L/LE 125W 15340 lm T6-50 to +40 T5-50 to +55 T6-50 to +40 T5-50 to +55 T6-50 to +40 T5-50 to +55 T6-50 to +40 T5-50 to +55 13kg 13kg 13kg 13kg Options - Suffix to Catalogue No. /M25 M25 cable entries /DC DC voltage (60W only) 450.8 132.7 377.8 287.6 357.3 Ø13 79 213.5 50.8 Accessories Should be ordered separately Pole mounting bracket assembly Wire guard Anti glare shield Catalogue Order Code Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. August 2014 Rev 2 Chalmit, PO BOX 5575, Glasgow G52 9AP Tel: +44(0) 141 882 5555 Fax: +44(0)141 883 3704 www.chalmit.com info@chalmit.com

SCOTIAEx Ex Ex d d e e LED LED FLOODLIGHT The ScotiaEx LED Zone 1 floodlight range is low energy with an instant on output and 110,000 maintenance free hours. Specifically designed for applications where moisture, dirt or dust are present, the floodlight is highly vibration resistant and can be used in locations where flammable vapours, gases or combustible dusts exist. Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Entry Termination Installation Control Gear Luminaire Efficacy Ingress Protection Surge Protection Electrical Supply Ex d e (Flameproof, Increased Safety) Dust protected enclosure Group II Category 2 GD Zone 1 and Zone 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 Gas Groups IIA, IIB + H2 CML 14ATEX1086X Ex d e IIB + H2 Ex tb IIIC Refer to table for T Class & Ambient Aluminium Alloy LM6 2 x M20 cable entries 3 core 6mm² max. conductor with looping Stirrup mounting Electronic driver >80 lm/w IP66 20kV 120-277V AC 50/60Hz Instant on crisp white light ouput Colour temperature 5000K (CCT) Highly energy efficient 110,000 maintenance free hours @ 25 C Less power used than HID lamps High ingress protection Low temperature applications to -50 C

ATEX CATEGORY 2 2 ZONE 1 & 1 & 21 21 APPLICATIONS Std. Cat No. Power Consumption Delivered Output TClass T C (Dust) Ambient C Weight SCOD/07L/LE 90W 7182 lm SCOD/08L/LE 105W 8362 lm SCOD/11L/LE 110W 10590 lm SCOD/12L/LE 125W 11560 lm Note: For alternative beam options, please contact Chalmit Internal Sales. T6 76-20 to +40 T5 91-20 to +55 T6 76-20 to +40 T5 91-20 to +55 T6 76-20 to +40 T5 91-20 to +55 T6 76-20 to +40 T5 91-20 to +55 21kg 21kg 21kg 21kg Options - Suffix to Catalogue No. /M25 M25 cable entries /LT Low temperature to -50 C (Gas groups IIA and IIB only) 397.4 175.5 317.5 108.5 64 237.7 134.7 332.2 450.9 50.8 Accessories Should be ordered separately Pole mounting bracket assembly Wire guard Catalogue Order Code Anti glare shield Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. November 2014 Rev 1 Chalmit, PO BOX 5575, Glasgow G52 9AP Tel: +44(0) 141 882 5555 Fax: +44(0)141 883 3704 www.chalmit.com info@chalmit.com

SOLAS 1 EMERGENCY LED FLOODLIGHT Ex de PROTECTION SOLAS is a new generation of LED luminaire. Using ultra bright LEDs, it produces a whiter more focused light that an equivalent 70W HPS lamp. Available with a self contained battery, it can also be used for backup emergency lighting. The long life of the LEDs makes it possible to use the luminaire continuously in normal operation (maintained), whilst still ensuring illumination in the event of a power failure. Alternatively it can simply be used as an emergency luminaire (non-maintained). The unique characteristics of the SOLAS offer a flexible luminaire that is as well suited to providing focused area lighting, illuminating safety critical areas in an emergency situation. A remote inhibition facility is available on all emergency versions. The range is available with options for operation down to -55 C making it ideal for low temperature applications. Solas with external switch Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector Entry Termination Installation Control Gear Batteries Light Source Burning Position Ingress Protection Electrical Supply Emergency Light Duration Ex de (Flameproof & Increased Safety) Group II Category GD Zone 1 & 2 areas to EN 60079-10 with installation to EN 60079-14 ATEX Certification Baseefa11ATEX0090 IECEx Certification IECEx BAS 11.0047 Ex II 2 GD Ex d e IIB T5 Gb Ex tb IIIC T100 C Db IP6X Aluminium alloy LM6 Toughened glass window All fastenings 316 stainless steel 2 x M20 cable entries - Non-emergency version: looping for 4mm² cable Emergency version: single entry only for 4mm² cable 4 core 4mm² max. Stirrup mounted Electronic Internal Rechargeable Ni-Cad 34 High power Light Emitting Diodes (LEDs) Universal IP66/67 to EN 60529 220-254V 50/60Hz 90 minutes (100% output) Maintained as standard Ex e terminal chamber No re-lamping required - over 60,000 hours continuous operation Low ambient temperatures Non-maintained or Maintained modes Output of over 4000 lumens comparable with 70W HPS floodlight Emergency Inhibition

ATEX CATEGORY 2 ZONE 1 APPLICATIONS 2 Std. Cat No. Wattage Lamp TClass T C (Dust) Ambient C Weight SOLD/034/LE 34W Light Emitting Diodes T5 70-55 to +55 24.0kg SOLD/034/LE/EM 34W Light Emitting Diodes T5 70-20 to +45 29.0kg SOLD/034/LE/EM/NM 34W Light Emitting Diodes T5 70-20 to +55 29.0kg Options - Suffix to Catalogue No. /M25 M25 cable entries /3H 3 hour emergency operation (50% output) /P PTFE coating /SC Screwed connections (minimum temp changes to -50 C) /N /NM /LT Narrow beam spread Non-maintained emergency version Low temperature (emergency only) Non-maintained -55 to +55 C Maintained -55 to +45 C Non emergency version: looping for up to 6mm² cable Non maintained emergency: single entry only for up to 6mm² cable Maintained emergency version: screwed connections not available /120 110-130V Supply 300 CRS (VARIOUS MOUNTING HOLES MAY BE ADDED) 14mm DIA THRU HOLES - 2 OFF VIEW SHOWING POLE CLAMP ARRANGEMENT SUITABLE FOR 42-64MM DIA POLES (BRACKET PART No: S2610-0001) 241 332 Ø406 Accessories Should be ordered separately Catalogue Order Code Pole mounting bracket S2610-0001 Wire guard S2610-0005 Remote switches are available upon request, please contact technical sales (techsupport@chalmit.com) Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. Chalmit, PO BOX 5575, Glasgow G52 9AP Tel: +44(0) 141 882 5555 Fax: +44(0)141 883 3704 www.chalmit.com info@chalmit.com Oct 2013 - Rev 6

NexLED E Ex e ib mb EMERGENCY 64 NexLED with Exit Sign kit The NexLED emergency provides emergency battery backup to ensure continued operation in the event of a power outage. The emergency version benefits from the same features as the standard NexLED and is available as a special low temperature version for operation down to -45 C. Coloured LED options are also available. NexLED with green LED s Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector Entry Termination Installation Light Source Control Gear Burning Position Ingress Protection Battery Emergency Duration Electrical Supply Ex e ib mb (Increased Safety, Intrisically Safe Encapsulated) Dust protected enclosure Group II Category 2 GD Zone 1 and Zone 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 EC Type Examination Certificate Baseefa04ATEX0245 IEC Ex BAS09.0062 II 2 GD Ex e ib mb IIC T4 Aluminium alloy LM6 to BS 1490 (AC44100) with toughened glass and silicone gasket Brushed aluminium 2 x M20 cable entries 4 core 4mm² max conductor with looping Surface mounted, 4 mounting holes located outside of seal 1W light emitting diodes. Colour: white Electronic Universal IP66/67 to EN 60529 Ni-Cd (6V) 8W version - 90 minutes 2W version - 3 hours 110-254V AC/DC Installation to gas groups IIA, IIB and IIC Highly visible, instant light Easy to install and maintain Ultra long life, no relamping required Very low power consumption 100% output in emergency mode (Up to 3 hours) Rechargable Ni-Cd batteries with charging indication Compatible with UPS systems International Approvals ATEX and GOST IECEx Compliant

ATEX CATEGORY 2 ZONE 1 & 21 APPLICATIONS 65 Std. Cat No. Wattage Light Source TClass T C (Dust) Ambient C Weight NELE/201/LE/EM 2W Light Emitting Diode T4 100-20 to +55 4.0kg NELE/801/LE/EM 8W Light Emitting Diode T4 100-20 to +55 4.1kg Options - Suffix to Catalogue No. /RDE Red LED s /ADE Amber LED s /GDE Green LED s /LT Low temperature -45 C to +55 C /BDE Blue LED s /IEC Supplied with IECEx certification label Accessories Should be ordered separately Catalogue Order Code Exit sign kit (supplied with - up, down, left and right labels*) * Other signage options available upon request, please contact technical sales (techsupport@chalmit.com) SNEL1-0008 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.

NexLED LED Bulkhead 116 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance free and unaffected by low temperatures. This combination makes the NexLED ideal for extreme environmental applications. Coloured LED options are also available. NexLED with green LED s Standard Specification Features Enclosure Reflector Entry Termination Installation Lamp Type Cast aluminium with toughened glass and silicone gasket Brushed aluminium 3 x M20 cable entries 4 core 4mm² max conductor with looping Surface mounted, 4 mounting holes located outside of seal 2 x 1W light emitting diodes or 8 x 1W light emitting diodes. Colour: white Highly visible, instant light Easy to install and maintain Ultra long life, no relamping required Very low power consumption 100% output in emergency mode (Up to 3 hours) Rechargable Ni-mH batteries with charging indication Compatible with UPS systems Control Gear Electronic Burning Position Universal Ingress Protection IP66/67 to EN 60529 Emergency Duration 3 hours (emergency models) Electrical Supply 220-240V ac/dc

INDUSTRIAL and MARINE APPLICATIONS 117 Std. Cat No. Wattage Lamp Type Ambient C Weight NELI/201/LE 2W Light Emitting Diode -20 to 45 3.5kg NELI/801/LE 8W Light Emitting Diode -20 to 45 3.5kg NELI/201/LE/EM 2W Light Emitting Diode -20 to 45 3.5kg NELI/801/LE/EM 8W Light Emitting Diode -20 to 45 3.5kg Options - Suffix to Catalogue No. /RDE Red LED s /ADE Amber LED s /GDE Green LED s /LT Low temperature -45 C to +45 C /BDE Blue LED s Accessories Should be ordered separately Green exit sign kit (4 labels - up, down, left and right) Catalogue Order Code SNEL1-0008 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.

STARLINE LED 1 STREET LANTERN The Starline LED perfectly combines innovations in heat management, optical performance and energy saving in a sleek exterior. The luminaire minimises energy and operating cost by reducing overlighting; resulting in very low thermal resistance high power LEDs that give exceptionally low lumen depreciation over life. The ultimate solution to replace traditional HID sources with versatility and reliability. The low profile appearance and low weight allows the Starline LED to be safely installed on existing column infrastructure. Standard Specification Features Ingress Protection Enclosure IP66 Die cast aluminium alloy marine grade polyester powder coat paint Slim, elegant design Latest generation high flux density LED LED Colour Diffuser Reflector Neutral white (CCT = 4000K) Flat glass, full cut off Highly specular aluminium, > 95% total reflectance Superior luminaire efficacy up to 1101 lm/w Maximised savings on energy and maintenance costs Dark sky friendly, no upward light Installation Control Gear Windage Electrical Supply Universal spigot cap to suit 34-42mm diameter Side entry as standard High efficiency electronic driver 0.06m² 110-254V 50/60Hz Lightweight and low windage allowing retrofit onto existing columns Colour Rendering Index >70 L80 = 90,000hrs (700mA, Ta = 15ºC) Suitable from -40ºC to +55ºC (dependant on driver current)

INDUSTRIAL APPLICATIONS 2 Std. Cat No. Luminaire Power Delivered Output Driver Current Weight STAI/088/LE 88W 9591 lm 200mA 13.8kg STAI/149/LE 149W 16120 lm 350mA 13.8kg STAI/211/LE 211W 21957 lm 500mA 15.0kg STAI/296/LE 296W 27628 lm 700mA 15.0kg Intelligent dimming systems are available. For further information please contact technical sales (techsupport@chalmit.com) Options - Suffix to Catalogue No. /PT Post top universal spigot top 60-76mm diameter /W Wide beam 326 115 992 872 60 892 238 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. Chalmit PO BOX 5575, Glasgow G52 9AP Tel: +44(0) 141 882 5555 Fax: +44(0)141 883 3704 www.chalmit.com info@chalmit.com Sept 2013 Revision 2