DIGITAL HOT WATER SOLUTIONS

Similar documents
DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

Digital Hot Water Systems

IntelliStation. The Smart Mixing & Recirculation System. For Domestic Hot Water in Commercial and Institutional Facilities. PowersControls.

Risk Assessment and Control Measures for Household Hot Water Systems

Thermostatic mixing valves with replaceable cartridge for centralized systems

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Build on Uponor with Aqua Port Central. Central fresh domestic hot water stations for private homes, hotels and healthcare

ADMS. AERCO Digital Mixing Station. AERCO.com

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Intelligent System Solutions Steam Air Hot Water

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Water Heater Mixing Valve

Legionella Policy and Procedure

aquablend thermostatic mixing valves

Healthcare Solutions. The Right Remedies for Patient Safety and System Efficiency

Description of the property and water systems:

SmartPlate. Water Heaters. AERCO.com

The Safety Valve Specialist TMV2. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

installation INSTRUCTIONS

heat interface units A BOILER WITHOUT A FLAME

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

EFG ENERGY OPTIMISING SYSTEMS

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

enviro iq Advanced Comfort Control and Energy Management for the Hospitality Industry

Thermostatic Mixing Valves

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

The Safety Valve Specialist Thermostatic Shower Controls

air handling units AT THE LEADING EDGE OF AIR FLOW

CONDENSING HIGH EFFICIENCY BOILERS

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Thermostatic mixing valves with interchangeable cartridges

WATER TEMPERATURE MANAGEMENT POLICY

Advanced Facility Air-Management Technology

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

GasGard 100 Control System

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

Electronic Dual Cylinder Thermostat User Instructions

DUKE UNIVERSITY DESIGN GUIDELINES

Electronic Dual Cylinder Thermostat Installation Instructions

DigiTemp. Digital Water Tempering System. PVI.com

MAXIMISER Semi-Storage Calorifiers

New Zealand Sales Hotline: Sales Fax:

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

Efficient DHW and heating solution with High-output calorifier Modul-plus

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Installation & Operation Manual Models: TSU

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

High-output calorifier Modul-plus

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Flo-Rite-Temp Instantaneous Steam/Water Heater

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Trane Family of Terminal Products

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SIMPLICITY OR FULL MODULARITY?

Increase the attractiveness of your multi-family building

Outdoor Reset Control Theory FULL versus PARTIAL reset

Contamination Control for Electronic and Semiconductor Applications

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

SIMPLICITY FULL MODULARITY?

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

SEC Signature Process Gas Analyzer

The integral solution for. Air Handling Units. Technology & Evolution

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Connected Control (BCC100)

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

Technology Menu Care Laundry

prestige Control Application Supplement - ACVMax

Flo-Rite-Temp Instantaneous Steam/Water Heater

CONTROLLED CHILLED BEAM PUMP MODULE

50 Series AQUAZONE Water Source Heat Pumps

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

Take Back Control of Hot Water With Electronic Technology

CO 2 Laser. High Reliability and Performance

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

Packaged Semi-Instantaneous Steam Fired Water Heater

Control Application. Supplement - ACVMax

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013

Automatic Temperature Controller (ATC)

THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Transcription:

DIGITAL HOT WATER SOLUTIONS

ARMSTRONG IS A TRUSTED GLOBAL LEADER IN INSTANTANEOUS HOT WATER GENERATION, DISTRIBUTION AND PRECISION TEMPERATURE CONTROL With in-depth knowledge and experience that spans more than a century, Armstrong understands your hot water system dynamic in ways no one else can. DUTY OF CARE Any building that is used by people other than the owner, the owner or manager has a legal responsibility placed upon them to ensure that others can use the building safely. Additionally, Building Services professionals have a Duty of Care to ensure that hot water generation and distribution systems are designed, installed, serviced and expertly maintained so that risks from scalding or bacterial infection are reduced and kept to an absolute minimum. Despite this a significant number of building occupants are still injured or die every year because of these risks. Example : In August 2012, a tourist staying in an Edinburgh hotel (Scotland) was severely scalded whilst showering and died later in hospital after 6 weeks in intensive care. The hotel operator was recently forced to pay a six figure compensation to the family of the victim. Chart 1 - Length of time for hot water to cause 3rd degree burns Temperature ( C) Time (adult) Time (child under 5) 38 cool bath average bath 39 average bath warm bath 50 9.5 minutes 4.5 minutes 52 2 minutes 1 minute 54 30 seconds 10 seconds 56 15 seconds 4 seconds 58 5 seconds 1 second 65 1.8 seconds 0.5 second MANAGING THE RISK The major risks related to the provision of hot water in a building are the risk to users of scalding from too hot water and Legionnaires Disease. Both problems are linked as one directly affects the other. The usual method for controlling Legionnaires Disease is to keep water hot. However, increasing hot water temperatures to kill bacteria brings an increased risk of scalding, which must also be controlled. You can see from the chart 1 and figure 1, that risk can be readily managed by ensuring the hot water delivered to bathrooms is no higher than 52 C. At this temperature Legionella bacteria cannot multiply, and will die over time, and a serious scald, even for a child, will take a submersion time of minutes rather than seconds to occur. 70 60 50 40 30 20 10 Figure 1 - Effect of temperature on bacteria growth Instant death of bacteria Death of 90% of bacteria within 2 minutes Death of 90% of bacteria within 2 hours Optimum temperature for growth of bacteria 20-45 C 0 Bacteria survive inactive C

LEGIONELLA GUIDELINE COMPLIANCE There are a number of codes of practice and applicable guidelines for the control of Legionella, often with similar advice - that hot water should be stored at a temperature of at least 60 C and distributed at a minimum of 50 C. Examples of applicable guidelines: ASHRAE Guideline 12-2000 ASHRAE Standard 188-2015 Legionellosis : Risk Management for Building Water Systems UK Health & Safety Executive HSG274 Part 2 : The Control of Legionella Bacteria in Hot and Cold Water Systems US Dept. of Labor OSHA Technical Manual, Section III, Chapter 7, Legionnaires Disease As explained in HSG274 the risk of scalding at 50 C is low for most people so point of use thermostatic mixing valves, after an appropriate risk assessment, can be safely removed, if circulating the hot water at this temperature. For Elderly Care Homes and Healthcare facilities, it is recommended that the temperature out of the fixtures should be further reduced to 43/46 C, depending on the type of fixture. Armstrong understands the Legionella Guidelines, and how to apply them, and we have the hardware to keep your hot water system compliant and the monitoring and recording software to prove it. In the right conditions a few Legionella bacteria can grow from a few cells to a colony of millions within 8-10 days. YOUR ADVANTAGE The ability to, very accurately, deliver tempered water at 52 C to the entire hot water network greatly reduces the risk of scalding from every fixture. This can remove the requirement for thermostatic mixing valves (TMV s). Eliminating TMV s from bathrooms reduces room entry necessary for maintenance, which, in the case of hotels can cause revenue loss, or in hospitals increase risk of bringing dirt and bacteria into the medical space. Even if the decision is to use a TMV s, by limiting the hot water temperature to the fixture, increased safety is guaranteed in the event of a TMV failure. The advantage, to the owner, of eliminating or reducing the number of TMV s in the building, is that the cost of installing the hot water system is greatly reduced - often by around 50%. Circulating the hot water around the building at 52 C, rather than 60 C, saves energy - by reducing the heat losses in the hot water loop and thus the cooling load on the building. ALL ADVANTAGES PROVIDED WITH THE INSTALLATION OF THE ARMSTRONG BRAIN DIGITAL RECIRCULATING VALVE!

THE BRAIN DIGITAL RECIRCULATING VALVE (DRV) Armstrong introduced digital water temperature control to the world with The Brain Digital Recirculating Valve (DRV). Engineered exclusively for recirculating hot water systems, The Brain simplifies your hot water system to deliver unparalleled accuracy, stability and safety. It offers programmable temperature alerts and a program to promote compliance with recommended Legionella guidelines.. FEATURES Designed specifically to be the primary water temperature controller in a continuously pumped circulating hot water system in a commercial building. Digital technology provides enhanced water temperature control accuracy regardless of whether a circulating system is simply idling or maximum draw-off is taking place. Performance +/- 1 C control 0.5 C minimum system temperature loss Smarts Component self-diagnostics Programmable set point & alerts Programmable Thermal disinfection Safety Over temperature shutoff Power failure shutoff Emergency mode Global Acceptance Marriott International has selected The Brain as its corporate standard domestic hot water temperature control device for all new hotels. Connectivity Integral Modbus RTU interface (The Brain ) SAGE - Building System interface module - Web Enabled - Modbus - BACnet - LonWorks The Brain can be installed as the final temperature control device before the hot water leaves the plantroom or be used to create control zones within the building to simplify balancing, improve circulation and easily manage a thermal disinfection regime. The Brain is also a retrofit to existing problematic hot water systems.

REX DUAL 30 BUILT-IN HOT WATER SAFETY FROM THE START With integrated systems for generating hot water, as below, now common, maintaining accurate temperature control can often be difficult. The installation of the Brain between the hot water generation plant and the user is an intelligent system operation protocol that will ensure the comfort and safety of users at all times and from every bathroom fixture. 6.10 Combination of solar, heat pump and gas fired DHW generation (Typical) THE BRAIN WITH SOLAR & HEAT PUMP & BOILER 52 C HEAT PUMP The Brain is designed to be the final temperature control device for any hot water generation system. DOMESTIC HOT WATER SYSTEM BALANCING The improper balancing of hot water flow and return circuits can cause long lengths of stagnant water in the pipework. This increases Legionella growth risk and wastes utilities due to users having to wait for extended periods for hot water. Rather than controlling the circulation of the complete hot water system from the plantroom it is beneficial if the network is divided into manageable zones. A zoned hot water system will be simple to balance system; which will maintain accurate temperature control at all demand conditions, ensure good pipeline velocities around the whole circuit and make any thermal disinfection regime easy to manage. A Digital Recirculating Valve complete with its own dedicated hot water recirculating pump can be installed to control the hot water flow and return temperatures for each designated zone, which could be a single floor or a group of floors or risers.

THE BRAIN - ZONING Using the Brain s unique ability to control accurately with a small differential temperature, between the valve outlet and hot water return, it enables the design of shorter recirculation loops, and so maintain tighter control of the loop temperature, keeping in the Safe zone of 52/50 C. The design of the hot water system for high-rise buildings can be challenging. Due to high static water pressures in the risers, which need to be reduced before being delivered to the fixtures, it can mean having to install a pressure reducing valve to each room in the building. THE BRAIN - SINGLE & MULTIPLE FLOORS - LOW RISE The Brain Legend : BV IV Balancing Valve Isolation Valve Recirculation Pump The Brain THE BRAIN - SINGLE & MULTIPLE RISERS The Brain The Brain Legend : BV Balancing Valve IV Isolation Valve PRV Pressure Reducing Valve Recirculation Pump

To reduce installation and ongoing maintenance costs it is possible to create low pressure temperature control zones in the building, using only two Pressure Reducing Valves per zone, as shown below. A small brazed plate heat exchanger acts as a barrier between the high pressure riser and the low pressure zone/loop serving the room fixtures. Any temperature loss in the low pressure recirculation loop is made up via the heat exchanger. During demand periods hot and cold water is reduced in pressure before being blended in the Brain and sent at a safe temperature to the fixtures. THE BRAIN - SINGLE & MULTIPLE FLOORS - HIGH RISE WITH PLATE HEAT EXCHANGER High Pressure Low Pressure The Brain Legend : CV Check Valve BV Balancing Valve IV Isolation Valve PRV Pressure Reducing Valve Recirculation Pump High Pressure Low Pressure The Brain Armstrong can deliver a tailor made solution for any zoning requirement. A pre-packaged system from Armstrong will ensure a simple and time efficient installation that will operate correctly the first time, every time, with minimal or no commissioning. Zoning package with Plate Heat Exchanger & PRV s Digital Mixing Centre with duty/ stand-by Brains for installation in a ceiling void

THE FUTURE OF HOT WATER SYSTEM MANAGEMENT IS HERE. SAGE raises utility system management to a groundbreaking new level by enabling you to maximize equipment reliability, efficiency and safety. The powerful software uses our patented algorithm as it analyzes data to track behavior and performance, making SAGE the most advanced tool for smart thermal utility monitoring, measuring and reporting available today. SAGE IS AN INTEGRAL PART OF YOUR COMPLETE HOT WATER SYSTEM SOLUTIONS. SAGE was engineered to work seamlessly with all of Armstrong s real-time monitoring products, including The Brain.

SMART SYSTEM MONITORING, THE BRAIN AND SAGE SAGE works seamlessly with The Brain as it analyzes data to track behavior and performance as an integral component of a hot water system operation protocol which complies with a Standard of Care. FEATURES Simple, effective monitoring, logging and remote alerting of key temperature control components of a hot water system safety risk management plan, for a modest monthly fee. Dashboard Monitoring In real time. Secure Remote Programming You are in control. Multi-location View All properties simultaneously or filtered. Temperature and System Diagnostic Alerts In real time. Digital Documentation and Recordkeeping For as long as you want to retain it. BENEFITS Safety Early warning system if hot water temperature do not meet specification. Patient/guest/student safety. Compliance Track and document hot water system behavior and performance to ensure compliance with global hot water safety system guidelines implemented to reduce the risk of Legionella. Performance SAGE is programmed to track warranties, recommend/remind service intervals and communicate/suggest manufacturer recommended parts replacements provides hotel owner/operator room compensation protection. DOCUMENTATION & RECORDKEEPING Establish documentation and maintain records. CONTROL LIMITS Establish limits within which a chemical or physical (water temperature) parameter must be monitored and maintained. MONITORING Establish a system for monitoring the parameters associated with the control limits. Hot water storage temperature Mixed outlet from the Brain to rooms Brain controls accurately to better than+/-1 C no matter the demand Hot water return temperature Drop in temperature indicates large instantaneous hot water demand as cold water enters the Brain

PACKAGES TO SUIT YOUR INDIVIDUAL APPLICATIONS Armstrong International manufactures a range of Digital Hot Water Solutions that incorporate all the advantages of The Brain Accuracy, Simplicity, and Connectivity. Digital-Flo Water/Water: Delivers blended hot water at +/- 1 C, even at very low flows Water temperature raised above Legionella survival levels on every recirculation cycle Digital-Flo Semi-Storage: Delivers blended hot water at +/- 1 C, even at very low flows Water in the tank is raised above 70 C, which greatly reduces the risk of Legionella proliferation in the tank Delivers a 25% higher peak flow compared to a standard system with the same size tank Enables the use of smaller tanks, thus a reduced footprint Energy efficient - tanks are insulated with 100mm glass fibre Buffer vessel in 316L stainless steel

Digital-Flo Vertical Semi-Instantaneous Steam/ Water Heater: Pre-Piped Digital Hot Water Generation and Control Solutions Featuring The Brain Digital Recirculating Valve Choose from 16 standard assemblies or customize Compact vertical design Small footprint Simple tube bundle access Optional SAGE Building System interface with integral data-logging Water temperature raised above Legionella survival levels on every recirculation cycle All Armstrong Digital-Flo hot water generation packages are compatible with the optional SAGE Building System interface with integral data-logging. REGARDLESS OF THE METHOD YOU USE TO HEAT WATER, WE HAVE THE INTELLIGENT SOLUTIONS YOU NEED. Our experts will show you how to avoid scaling, improve efficiency and safety. ARMSTRONG DOES IT ALL. We can solve your problems and prevent them with a packaged solution designed specifically for your unique parameters. We offer a full range of individual state-of-the-art products, including: water heaters, water temperature controls, hose stations and ancillary accessories such as storage tanks, pressurereducing valves and more. From a complete, fully integrated hot water system for a new installation to custom-engineering and turnkey solutions for each of your existing buildings worldwide, Armstrong is your single source solution.

INTELLIGENT SOULUTIONS IN STEAM, AIR, AND HOT WATER Armstrong International Europe / Middle East / Africa armstronginternational.eu Armstrong International, SA Bulletin 435-A/Eng 08/17