Center Mount Unit Coolers

Similar documents
Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Flow Unit Coolers

Low Profile Unit Coolers

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Low Profile Unit Coolers

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Slim Contour Unit Cooler

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Super-Flo Low Profile Unit Cooler

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Air-Cooled Condensers

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

High Profile Evaporator

Packaged refrigeration system Technical Guide

KTL Two-Way Low Profile Evaporators

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

Packaged Refrigeration Systems

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

PRO 3 TOP MOUNT & SIDE MOUNT PACKAGED REFRIGERATION SYSTEMS Technical Guide

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

KTL Two-Way Low Profile Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

Installation, Operation, and Maintenance Information

BTL Two-Way Low Profile Evaporators

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensers

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Industrial Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Price List. BN-PL Oct. 2017

Price List. BN-PL Jan. 2018

LK-PL Jan Price List

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Price List. CC-PC-PL Jan. 2019

MACH N-407 Heat Pump Air-Cooled Chiller

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

T H I N K I N S I D E T H E B o x

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Condensing Units & Air Handlers

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

Specifications and Performance S2H

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

KR Series Air Defrost Unit Coolers Operating and Installation Manual

horizontal air discharge outdoor discus condensing unit

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

KR Electrical Defrost Unit Coolers (PN E108318_E)

13 GEP A L P - 1 A

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products

HEATING & COOLING COIL PRODUCTS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TLV Low Velocity Evaporators

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Commercial High-Efficiency Condensing Units

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

SMALL AIR COOLED CONDENSERS

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

RSG16**S1M. Split System Air Conditioner 16 SEER

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL SPECIFICATIONS

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Specifications. Vertical Floor Consoles By First Co.

CWA4 Chilled & Hot Water Fan Coil

PACKAGE AIR CONDITIONER

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

RGE 13 A T - 1 A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Half Round Evaporators

VERTICAL FAN COIL UNITS

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Transcription:

CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost

Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4 Specifications...5 Physical Data...6 Dimensional Data...6 Replacement Parts by InterLink...7 Standard Nozzle Selection...7 Choose the most energy-efficient motor available for evaporators. The EC motor is an energy sufficient option on Climate Control Center Mount evaporators. Available on all new equipment or as an easyto-install, drop-in replacement aftermarket part from InterLink Commercial Refrigeration Parts. Because they are a drop-in replacement for existing shaded pole and PSC motors, installation is quick and easy. It s a high impact, quick payback solution for reducing costs and achieving green initiatives without replacing the entire system. EC motors by InterLink are up to 75% energy efficient - that s a 51-59% increase over shaded pole motors and a 30-35% increase over permanent-split capacitor (PSC) motors. With all of this added efficiency, you can count on more energy savings and lower operational costs while taking a step in the right direction toward conserving our planet s resources. Nomenclature TLC 052 A E Series Capacity Electrical Code Design Revision 2 TLC = Climate Control Center Mount, air defrost TLF = Climate Control Center Mount, electric defrost # BTUH x 100 A = 115/1/60 B = 208-230/1/60 AE = 115/1/60 (EC) BE = 208-230/1/60 (EC)

Features & Benefits Cabinet Air moves across the ceiling in both directions providing even air distribution throughout the cooler Compact, ceiling mount and center mount design allows for shelving and storage of product around all walls Heavy-gauge grained aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Panels on ends quickly remove for complete access to refrigerant components and electrical terminal block during installation and servicing Quick disconnect, waterproof plug and receptacle for each motor in all models Wire fan guards with PVC coating for durability Coil High-efficiency aluminum fins with full collars cover mechanically expanded copper tubes Coils are dehydrated and sealed at the factory Highest quality tubular heaters provide fast and economical defrost Generous coil surface gives proper compressor balance Standard adjustable defrost termination fan delay thermostat Controls Options Quick Response Controller units come factory mounted with an electronic expansion valve, pressure transducer, temperature sensors and control board Beacon II units come factory mounted with an electronic expansion valve, pressure transducer, temperature sensors and control board Drain Pan Double drain pan eliminates drain pan sweating Tapered mounting provides proper slope for condensate drainage to one end of the unit Motors Motors are life lubricated and thermal overload protected EC motors (optional) available factory-installed or as a drop-in replacement through InterLink Commercial Refrigeration Parts in 115/1/60, 208-230/1/60 voltages Additional Options Factory installed mounted components are available in these configurations: Pre-assembled units come with mounted TXV, liquid line solenoid valve and room thermostat Pre-charged units come with mounted TXV, liquid line solenoid valve, room thermostat, and quick connect fittings Mounted TXV Mounted TXV and solenoid valve Mounted room thermostat Most models available with glycol circuiting (see glycol product brochure) Units available with stainless steel housing and drain pan Units available with copper fins. Air defrost units also available with polyester coated fins or various coil coatings options All Climate Control Center Mount units are UL listed for US and Canada and meet NSF standards 3

PERFORMANCE DATA TLC Air Defrost 60 Hz Capacity Fan Data 10 F TD 25 F SST 6 C TD -4 C SST 15 F TD 25 F SST 8 C TD -4 C SST BTUH Watts BTUH Watts CFM m 3 H TLC052 5,200 1,520 7,800 2,280 1 610 1,035 TLC076 7,600 2,230 11,400 3,340 2 1,300 2,210 TLC090 9,000 2,640 13,500 3,950 2 1,260 2,140 TLC102 10,200 2,990 15,300 4,480 2 1,220 2,075 TLC108 10,800 3,160 16,200 4,750 3 1,950 3,315 TLC134 13,400 3,920 20,100 5,890 3 1,890 3,210 TLC156 15,600 4,570 23,400 6,850 3 1,830 3,110 TLC179 17,900 5,240 26,850 7,860 4 2,520 4,285 TLC208 20,800 6,100 31,200 9,140 4 2,440 4,145 TLC249 24,900 7,290 37,350 10,940 5 3,050 5,185 TLC Air Defrost 50 Hz Capacity Fan Data 10 F TD 25 F SST 6 C TD -4 C SST 15 F TD 25 F SST 8 C TD -4 C SST BTUH Watts BTUH Watts CFM m 3 H TLC052 4,950 1,450 7,410 2,170 1 550 935 TLC076 7,220 2,110 9,880 2,890 2 1,170 1,990 TLC090 8,550 2,500 12,830 3,760 2 1,135 1,930 TLC102 9,690 2,840 14,540 4,260 2 1,100 1,865 TLC108 10,260 3,000 15,390 4,510 3 1,755 2,985 TLC134 12,730 3,730 17,420 5,100 3 1,700 2,890 TLC156 14,820 4,340 22,230 6,510 3 1,650 2,800 TLC179 17,010 7,980 23,290 6,820 4 2,270 3,855 TLC208 19,760 5,790 29,640 8,680 4 2,200 3,735 TLC249 23,660 6,930 32,400 9,490 5 2,745 4,665 TLF Electric Defrost 60 Hz Capacity Fan Data 10 F TD -20 F SST 6 C TD -29 C SST 12 F TD -20 F SST 7 C TD -29 C SST BTUH Watts BTUH Watts CFM m 3 H TLF040 4,000 1,170 4,800 1,410 1 610 1,037 TLF054 5,400 1,580 6,480 1,900 2 1,300 2,210 TLF065 6,500 1,900 7,800 2,280 2 1,260 2,142 TLF090 9,000 2,640 10,800 3,160 3 1,950 3,315 TLF130 13,000 3,810 15,600 4,570 3 1,830 3,111 TLF174 17,400 5,100 20,880 6,120 4 2,440 4,148 TLF Electric Defrost 50 Hz Capacity Fan Data 10 F TD -20 F SST 6 C TD -29 C SST 12 F TD -20 F SST 7 C TD -29 C SST BTUH Watts BTUH Watts CFM m 3 H TLF040 3,800 1,110 4,560 1,335 1 550 993 TLF054 5,130 1,500 6,160 1,890 2 1,170 1,989 TLF065 6,180 1,810 7,410 2,170 2 1,135 1,928 TLF090 8,550 2,500 10,260 3,000 3 1,755 2,983 TLF130 12,350 3,620 14,820 4,340 3 1,650 2,800 TLF174 16,530 4,840 19,840 5,810 4 2,200 3,733 4 For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic control of the motor)

SPECIFICATIONS TLC Air Defrost 60 Hz PSC Motor EC Motor HP 115/1/60 208-230/1/60 115/1/60 208-230/1/60 Amps Watts Amps Watts Amps Watts Amps Watts TLC052 1/15 0.9 90 0.5 90 0.9 55 0.5 55 TLC076 1/15 1.8 180 1.0 180 1.8 110 1.0 110 TLC090 1/15 1.8 180 1.0 180 1.8 110 1.0 110 TLC102 1/15 1.8 180 1.0 180 1.8 110 1.0 110 TLC108 1/15 2.7 270 1.5 270 2.7 165 1.5 165 TLC134 1/15 2.7 270 1.5 270 2.7 165 1.5 165 TLC156 1/15 2.7 270 1.5 270 2.7 165 1.5 165 TLC179 1/15 3.6 360 2.0 360 3.6 220 2.0 220 TLC208 1/15 3.6 360 2.0 360 3.6 220 2.0 220 TLC249 1/15 4.5 450 2.5 450 4.5 275 2.5 275 TLC Air Defrost 50 Hz PSC Motor EC Motor HP 110/1/50 220/1/50 110/1/50 220/1/50 Amps Watts Amps Watts Amps Watts Amps Watts TLC052 1/15 0.8 80 0.4 80 0.9 55 0.5 55 TLC076 1/15 1.7 160 0.8 160 1.8 110 1.0 110 TLC090 1/15 1.7 160 0.8 160 1.8 110 1.0 110 TLC102 1/15 2.5 240 1.2 240 1.8 110 1.0 110 TLC108 1/15 2.5 240 1.2 240 2.7 165 1.5 165 TLC134 1/15 2.5 240 1.2 240 2.7 165 1.5 165 TLC156 1/15 3.3 320 1.6 320 2.7 165 1.5 165 TLC179 1/15 3.3 320 1.6 320 3.6 220 2.0 220 TLC208 1/15 3.3 320 1.6 320 3.6 220 2.0 220 TLC249 1/15 4.2 400 2.0 400 4.5 275 2.5 275 TLF Electric Defrost 60 Hz PSC Motor EC Motor Heaters HP 208-230/1/60 208-230/1/60 208-230/1/60 Amps Watts Amps Watts Amps Watts TLF040 1/15 0.5 90 0.5 55 5.3 1200 TLF054 1/15 1.0 180 1.0 110 8.7 2000 TLF065 1/15 1.0 180 1.0 110 8.7 2000 TLF090 1/15 1.5 270 1.5 165 10.5 2400 TLF130 1/15 1.5 270 1.5 165 15.7 3600 TLF174 1/15 2.0 360 2.0 220 20.9 4800 TLF Electric Defrost 50 Hz PSC Motor EC Motor Heaters HP 220/1/50 220/1/50 220/1/50 Amps Watts Amps Watts Amps Watts TLF040 1/15 0.4 80 0.5 55 5.0 1100 TLF054 1/15 0.8 160 1.0 110 8.3 1826 TLF065 1/15 0.8 160 1.0 110 8.3 1826 TLF090 1/15 1.2 240 1.5 165 10.0 2200 TLF130 1/15 1.2 240 1.5 165 15.0 3300 TLF174 1/15 1.6 320 2.0 220 20.0 4400 5

PHYSICAL DATA TLC Air Defrost TLF Electric Defrost of Connections (in.) Approx. Net Wt. Inlet OD Suction OD lbs. kg TLC052 1 1/2 7/8 42 19 TLC076 2 1/2 7/8 64 29 TLC090 2 1/2 7/8 70 32 TLC102 2 1/2 7/8 83 38 TLC108 3 1/2 7/8 105 48 TLC134 3 1/2 7/8 117 53 TLC156 4 1/2 7/8 123 56 TLC179 4 1/2 7/8 149 68 TLC208 4 1/2 1-1/8 164 74 TLC249 5 1/2 1-1/8 206 94 of Connections (in.) Approx. Net Wt. Inlet OD Suction OD lbs. kg TLF040 1 1/2 7/8 90 41 TLF054 2 1/2 7/8 120 54 TLF065 2 1/2 7/8 120 54 TLF090 3 1/2 7/8 160 73 TLF130 3 1/2 7/8 174 79 TLF174 4 1/2 1-1/8 218 99 Dimensional Data L 28-13/16" 732 mm 5-3/4" 146 mm 22" 560 mm 3/8" DIA. MTG. HOLES 10-1/4" 261 mm 11-3/4" 299 mm 22" 560 mm 3-13/16" 97 mm 3/5" 31 mm 27-5/8" 702 mm 3/5" 31 mm 7-9/16" 6-7/8" 192 mm 175 mm 8-5/8" 219 mm AIR OUT AIR OUT 5-1/2" 140 mm ELECTRICAL CONNECTION (OPPOSITE SIDE) AIR IN AIR IN DRAIN REFRIGERANT CONNECTION (OPPOSITE SIDE) 2-7/8" 71 mm REFRIGERANT CONNECTION NOTE: All units have 1/4" OD external equalizer and 3/4" FPT drain connection TLC Air Defrost TLF Electric Defrost of in. Dimensions L mm TLC052 1 31-1/2 800 TLC076 2 53-1/2 1359 TLC090 2 53-1/2 1359 TLC102 2 53-1/2 1359 TLC108 3 75-1/2 1918 TLC134 3 75-1/2 1918 TLC156 4 75-1/2 1918 TLC179 4 97-1/2 2477 TLC208 4 97 1/2 2477 TLC249 5 119-1/2 3035 of in. Dimensions L mm TLF040 1 31-1/2 800 TLF054 2 53-1/2 1359 TLF065 2 53-1/2 1359 TLF090 3 75-1/2 1918 TLF130 3 75-1/2 1918 TLF174 4 97-1/2 2477 6

REPLACEMENT PARTS Commercial Refrigeration Parts Right source. Right parts. Right now. InterLink is your link to a complete line of dependable and certified commercial refrigeration parts, accessories and innovative electronic controls for all Climate Control equipment. At InterLink, we provide our wholesalers with a comprehensive selection of product solutions and innovative technologies for the installed customer base. And every product is built to ensure the same high performance standards with which all Heatcraft Refrigeration Products (HRP) brands are built backed by a dedicated team to serve every customer need, delivering at the best lead times in the industry. Dependable. Versatile. Courteous. Finally, one simple source for all your replacement needs from a name you can trust. For parts, please contact (800) 686-7278 or visit heatcraftrpd.com. Motor/Fan Blade/Fan Guards Part # Description 5036NS Motor 115/1/60/50 PSC 1-5 5036PS Motor 208-230/1/60/50 PSC 1-5 25317901 Motor 208-230/1/60 EC Totally Enclosed 1-5 25318001 Motor 115/1/60 EC Totally Enclosed 1-5 5110E Fan Blade 1-5 5055F Fan Guard - Wire 1-5 40003001 Motor Mount Plate 1-5 Standard Nozzle Selection TLC Air Defrost of Distributor Tube (in.) of OD Length Circuits R-404A* R-407A** TLC052 1 3/16 18 2 L-1/2 L-1/4 TLC076 2 3/16 18 2 L-3/4 L-1/2 TLC090 2 3/16 18 4 L-3/4 L-1/2 TLC102 2 3/16 18 4 L-1 L-3/4 TLC108 3 3/16 18 4 L-1 L-3/4 TLC134 3 3/16 18 4 L-1 L-3/4 TLC156 4 3/16 18 6 L-1-1/2 L-1 TLC179 4 3/16 18 6 L-1-1/2 L-1 TLC208 4 3/16 18 6 L-1-1/2 L-1-1/2 TLC249 5 3/16 18 6 L-2 L-1-1/2 TLF Electric Defrost Cabinet Components Part # Description C26363A2 Drain Pan - Stucco 1 C26360A2 Drain Pan - Stucco 2 C26361A2 Drain Pan - Stucco 3 C26362A2 Drain Pan - Stucco 4 40820301 Drain Pan - Stucco 5 40820601 Drain Pan - White 1 40820701 Drain Pan - White 2 C26361A4 Drain Pan - White 3 C26362A4 Drain Pan - White 4 D20817A4 Drain Pan - White 5 Electrical Components Part # Description 22512601 Terminal Board 4267W 4550G Electric Defrost Defrost Termination / Fan Delay Thermostat Filter (optional one per fan) Part # Description 4400S Coil Heater 040 1 4401S Coil Heater 054, 065 2 4402S Coil Heater 090 3 4403S Coil Heater 130 3 4404S Coil Heater 174 4 *Also suitable for R-507, R-502, R-134a, R-401A, R-402A, R-448A and R-449A ** Also suitable for R-407C, R-407F, R-22. Note: Nozzles sized for 90-100 F liquid temperature at expansion valve. Contact Application Engineering for guidance if: Liquid temperature is not 90-100 F Evaporator TD is not 10-15 F (room temperature saturated suction temperature) Electric defrost models with a saturated suction temperature of 10 F or higher Caution: Refrigeration system will not perform properly without correct nozzle! of Distributor Tube (in.) of OD Length Circuits R-404A* R-407A** TLF040 1 3/16 18 2 L-3/4 L-1/3 TLF054 2 3/16 18 2 L-3/4 L-1/2 TLF065 2 3/16 18 4 L-1 L-3/4 TLF090 3 3/16 18 4 L-1-1/2 L-3/4 TLF130 3 3/16 18 6 L-2 L-1-1/2 TLF174 4 3/16 18 6 L-2-1/2 L-1-1/2 7

2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 heatcraftrpd.com Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice. CC-CMTB-0717 Version 001 2016 Heatcraft Refrigeration Products LLC