Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Similar documents
Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Water Heaters. Solar Applications

Heat Transfer Packages

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Commercial Semi-Instantaneous Water Heaters

Packaged Semi-Instantaneous Steam Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Steam Fired Water Heater

EZ Plate Instantaneous

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Installation, Operation and Maintenance

SECTION DOMESTIC WATER HEATERS

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

TABLE OF CONTENTS BRADFORD WHITE BOILERS

SECTION ROTARY-SCREW WATER CHILLERS

Tankless On Demand Electric Water Heater

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

High Capacity Instantaneous Steam Fired Water Heater

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

.2 Section Waste Management and Disposal.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

ASME Packaged Indirect Fired Water Heater

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

SECTION WATER HEATERS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Triton Series High Efficiency Boiler

Control and power circuit fusing to meet N.E.C.

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Across-the-Line SERIES MP300 Combined Manual and Automatic

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Tepid Water Delivery System

SECTION PACKAGED HEAT TRANSFER SYSTEM

Power Flame Incorporated

BuildingName The Description of the Project P DOCUMENTS

Suggested Specifications Prestige Excellence 110

FXLF-9. High Efficiency Water Heaters and Boilers

Soft Start Series MP700 Solid State, Reduced Voltage

Indirect Fired Water Heater

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

AS950 REFRIGERATED SAMPLERS

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

SECTION AIR COOLED WATER CHILLERS

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

ADMS. AERCO Digital Mixing Station. AERCO.com

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

SECTION PLUMBING EQUIPMENT

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Variable Frequency Drive SERIES MP800 VFD

Revitalize Building Mechanical Systems (4619)

When reliability is vital. Alemite Carbon Shield TM Systems deliver

LC1350 Level Controller

AS950 PORTABLE SAMPLERS

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

RHP120 RHP300 Steam Boiler Series

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Honeywell SLATE ICM Platform

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Call us today! (800)

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

B-40/B-41 Modulating Temperature Controller

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

Sola Hydronic Control. An Eco-Friendly Solution.

ASME Packaged Electric Water Heater

Fast, Simple, & Easy to Use. One Company... Three Great Brands!

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

SmartPlate. Water Heaters. AERCO.com

High Efficiency Commercial Gas Water Heaters

Centro-Matic Automated Lubrication Systems System Controls

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Transcription:

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers to condense. Lower return temperatures to the boiler. Operate the boiler at a lower temperature.

Standard Equipment Brazed Plate Heater-BPH Series Plate and Frame Heater-PFH Series Cemline Brazed Plate Heaters are completely packaged and ready to use. All components are sized, mounted and piped prior to shipment. These heaters come complete and require only connection to services Advantages of Cemline Packaged Plate Fired Water Heater Cemline Packaged Plate Boiler Water Fired Water Heaters (BPH/PFH) are a perfect choice for domestic water heating systems using hydronic boilers including cast iron, copper tube, water tube, or specialty high efficiency boilers. The BPH uses a brazed plate heat exchanger for smaller loads while the PFH uses a plate and frame heat exchanger for larger loads. The BPH/PFH heat exchanger allows these boilers to operate more efficiently since the BPH/PFH heat exchangers can return the boiler water to the hydronic boiler at lower temperatures than the traditional u-bend heat exchanger. The boiler water can be returned to the boiler as low as 90 F from the BPH/PFH water heaters. Cemline Plate Heaters (BPH/PFH) are completely packaged and ready for use. The BPH/PFH can be used in conjunction with an existing tank or used as an instantaneous water heater. The heaters come complete and require only connection to services. The BPH/PFH heat exchanger has a high heat transfer rate allowing for maximum heat transfer between the boiler water and the domestic water. As the heat is transferred from the boiler water to the domestic water, the boiler water can experience large temperature drops through the heat exchanger. The BPH/PFH can achieve larger temperature drops through the heat exchanger requiring less gallons per minute of boiler water than a traditional U-bend heat exchanger that is performing a 20 F delta T on the boiler water side. The large temperature drops occur without laminar flow on the boiler water side of the heat exchanger. The heat exchanger can even allow for temperature crosses between the boiler water outlet and the domestic water outlet temperature, meaning the domestic water outlet temperature can be greater than the returned boiler water temperature. The boiler can be run at lower temperatures with the BPH/PFH s ability to perform temperature crosses and to take large delta T s as a lower boiler water temperature can be used to make domestic hot water. Cemline Corporation Plate Water Heaters are available with a storage tank either a cement lined STONESTEEL or 316-L stainless steel vessel in sizes 60,,, 300, 500, and 680 gallon capacity. See Cemline SPH brochure for more details. The Cemline BPH/PFH comes factory standard with a 2-way electronically operated control valve. The 2-way electronically operated control valve allows for close temperature control of the water heater by modulating flow of the boiler water through the heat exchanger. The BPH/PFH can achieve +/-2 F with a steady state flow and +/- 4 F under normal operating conditions. The 1000:1 turn down ratio of the control valve allows for accurate control of these water heaters. The Cemline BPH/PFH can be used for a variety of heat recovery systems or in hot water or chilled water systems. Contact Cemline Corporation with your specific application. Basic BPH/PFH Package Includes: 16 gauge steel frame with hammertone enamel paint Steel channel base Electronic temperature gauge. Water pressure gauge Brazed Plate Heat Exchanger (BPH) Plate & Frame Heat Exchanger (PFH) Integral bronze circulator Clean out ports Single safety system with electronic limit control 2-Way Electronic Control Valve CEM-TROL II Control Module Boiler water temperature gauge Inlet boiler water strainer Inlet domestic water strainer Pressure temperature relief valve Optional Trim Double Walled Plate Heat Exchanger (Brazed Plate or Plate and Frame) Boiler water pump Aquastat for boiler water pump Balance valve 3-way electronic boiler water control valve Multiple Brazed Plate units can be piped together with by-passes for larger flow rates or for redundancy Blowdown valves on strainers PT plugs California AB-1953 Lead-Free components 2

Standard Equipment Cemline Brazed Plate Heaters and Plate and Frame Heaters Cemline Brazed Plate Heaters and Plate and Frame Heaters are completely packaged and ready to use. All components are sized, mounted and piped prior to shipment. These heaters come complete and require only connection to services CEM-TROL II Control Module and Electronically Operated Control Valve Cemline CEM-TROL II Solid State Water Heater Control Module incorporates operating and limit functions in one solid state controller. The controller features a LCD touch screen display of the temperature and on board operating PID temperature control along with high temperature safety cut offs and alarm indications. The CEM-TROL II simplifies the control of Cemline Water Heaters, enhances the look of the product, and follows the industry trend to solid state controls. Electronically operated control valve used for boiler water applications. Electronically operated control valves use a solid state temperature sensor which is wired to the CEM-TROL II control module. The CEM-TROL II has an adjustable set point. The control module compares the set point with the sensed temperature and sends an electric signal to a magnetic linear actuator on the control valve. The magnetic linear actuator modulates the control valve and regulates the amount of boiler water through the valve to maintain the set point of the controller. When the set point is achieved the CEM-TROL II sends a signal to the valve actuator and the valve closes. In the event of high temperature or loss of building power the CEM-TROL II shuts off the electric power to the control valve closing the valve. Digital Electronic Temperature Limit Control. BPH/PFH Water Heaters have a Digital Electronic Limit Control with LCD readout. The ASME code requires that water heaters utilizing boiler water as the energy source have a high limit temperature control. The CEM-TROL II has an easily field-programmable high limit set point and differential. CEM-TROL II Features Built in PID Control Signal PID Control Signal to control electronic valve or control I-P transducer on Air operated control valve Built in LCD Touch Screen Display Display of operationing temperature, setpoint temperature, control output signal along with user friendly interface of the controller Built in On-Off Switch Built in Single Point Wiring Built in High Temperature Set Point Closes control valve in event of a high temperature situation Built in Secondary High Temperature Set Point Opens a water solenoid to dump over heated water down the drain Built in Remote Temperature Setting Building Automation System can remotely set the operating temperature using a 4-20 ma signal Built in LCD Touch Screen Display of Functions Power On Primary High Temperature Indication Secondary High Temperature Indication Built in Modbus Interface Building automation system can remotely communicate with the CEM-TROL II via RF-485 Connection. Built in contacts to notify BAS (Building Automation System) of functions Power On Primary High Temperature Secondary High Temperature Operating Temperature (4-20 ma) Any Limit CEM-TROL II Ratings Input Selectable /220 VAC-50/60 HZ Output Contacts: 1 amp at 24 VAC Building Automation outputs: Dry contacts, NO/NC 0.5 amp maximum, non inductive Display: LCD display with resolution of 0.3% of scale Available temperature ranges: 32 F F Operating ambient temperature: Min 32 F Max 1 F Operating Humidity: 5% to 95% relative humidity (RH) non-condensing NEMA 4 enclosure UL listed 3

Recovery Capacities Cemline Brazed Plate and Plate Frame Heaters Heat exchanger sizing for BPH/PFH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline website at www.cemline.com. Please contact Cemline or your local representative for sizing or for access to the on-line sizing program. Domestic Water Recovery as Energy Source Hex Model # Flow Rate gpm gpm 250 500 750 1000 1250 1300 1750* 0* 2250* 5 10 15 20 25 30 35 45 1 1 1 1 1 1 1 1 1 13 26 39 52 65 78 91 104 117 2500* 50 1 130 3000* 60 1 156 00* 80 1 208 5000* 100 1 260 Domestic Water Recovery Hex Model # 250 500 750 1000 1250 1300* 1750* 0* 2250* Flow Rate gpm 5 10 15 20 25 30 35 45 2500* 50 3000* 60 00* 80 5000* 100 as Energy Source gpm 1 180 1 13 1 180 1 26 1 180 1 39 1 180 1 52 1 180 1 65 1 180 1 78 1 180 1 91 1 180 1 103 1 180 1 116 1 180 1 129 1 180 1 155 1 180 1 207 1 180 1 258 BPH water heaters are not recommended for water with hardness over 1 parts per million. If water hardness exceeds 1 ppm either put a water softener in the system or use Cemline SEH, SSH, or SWH series water heaters. * When using a double wall heat exchanger a plate and frame style is required for these conditions. Domestic Water Recovery as Energy Source Hex Model # Flow Rate gpm gpm 250 500 750 1000 1250 1300* 1750* 0* 2250* 5 10 15 20 25 30 35 45 1 1 1 1 1 1 1 1 1 13 26 39 51 64 77 90 103 116 2500* 50 1 129 3000* 60 1 154 00* 80 1 206 5000* 100 1 257 4

[System Normal] Temp. Status Set Point 130 Deg F Normal 1 Deg F Valve 1 10.0 Volts Menu Power On Primary High Limit Secondary High Limit Cemline Plate Heaters Dimensional Data - Brazed Plate Heat exchanger sizing for BPH/PFH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline website at www.cemline.com. Please contact Cemline or your local representative for sizing or for access to the on-line sizing program. L CEM-TROL II W Temperature Sensors (or installed in storage tank) Control Valve Inlet Relief Valve Pipe to Drain Hot Water Outlet 36 H Outlet Cold Water Inlet Temperature Gauge Model Number W L H BPH 100-0 BPH 0 and Above 16" 24" 36" 36" 51" 51" 5

[System Normal] Temp. Status Set Point 130 Deg F Normal 1 Deg F Valve 1 10.0 Volts Menu Power On Primary High Limit Secondary High Limit Recovery Capacities Dimensional Data - Plate and Frame Heaters Heat exchanger sizing for BPH/PFH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline website at www.cemline.com. Please contact Cemline or your local representative for sizing or for access to the on-line sizing program. Thermometer L Control Valve Relief Valve W Temperature Sensors CEM-TROL II Inlet Strainer Outlet Hot Water Outlet Cold Water Inlet Pressure Gauge H 4 Steel Channel Base Domestic Water Strainer Model Number W L H PFH 1300-3000 PFH 3000 and Above 24" 30" 48" 54" 45" 52" 6

BPH and PFH Water Heaters- Sample Specifications For specifying Cemline Packaged Brazed Plate Fired Water Heater water heaters, select model from charts and use specification below. Cemline has representation in most major cities, or consult factory. BPH Water Heaters Plate heater shall be Cemline Series BPH (or PFH); factory assembled and packaged. Heater shall be mounted on an enameled metal base, 16 gauge minimum thickness. Heater shall be factory assembled and piped including electronic operated 2-way temperature regulating valve. Heat exchanger shall be single walled brazed copper brazed 316L stainless steel plate type (or double walled copper brazed 316L stainless steel plate type) and shall have an integral valved circulator to re-circulate the water through the heat exchanger. Heater shall be supplied with solid-state control module with LCD touch screen display and LED pilot lights to indicate on-off, primary high limit, and secondary high limit. Solid-state control module shall be provided with a field programmable digital electronic PID controller allowing the owner to set operating and temperature limits on the display screen. Solid-state control module shall have red alarm light and alarm horn with built in alarm silence relay. Solid-state control module shall be supplied with dry contact closure outputs to indicate to building automation system (BAS) the occurrence of power on, primary high temperature, and secondary high temperature.the control module shall allow the BAS to turn the heater on or off through a remote relay. The control module shall allow the BAS to remotely set the temperature of the heater using a 4-20 ma input signal. The control module shall allow the BAS to remotely monitor the operating temperature via a 4-20 ma signal. The control module shall allow the BAS to remotely monitor the operating temperature via 4-20 ma signal. Control module shall communicate with the BAS using Modbus Protocol via an RS-485 connection. Control module shall be supplied with an on-off switch and shall be mounted in a NEMA 4 panel. All solenoids and limits shall be 24 VAC. Heater shall be furnished with a water pressure gauge and an A.S.M.E. pressure temperature relief valve of sufficient size to relieve total BTU input of heat exchanger. Manufacturer shall assume responsibility for correct sizing of components to assure performance designated in design criteria. Heater shall be CEMLINE Corporation Model BPH/PFH. Unit dimensions width x long x height. Plate exchanger to heat GPH from F to F with GPM of F inlet F outlet Hot Water. Cemline BPH/PFH Series Packaged Heaters are normally piped as shown below. To System In Hot Water Boiler BPH/ PFH Hot Water Out Storage Tank House Recirculation Cold Water Supply Out 7

Sales Offices Alaska Hawaii Puerto Rico Saudi Arabia Taiwan U.A.E. Available Cemline Brochures www.cemline.com Product Sizing Programs Brochures I.O.M. Manuals Drawings & Specifications Agent Locator Plant Tour STONESTEEL - Water Storage Tanks - Jacketed Storage Tanks - Commercial Electric and Packaged Copper Coil Water Heaters Submerged Heating Coils Replacement Tube Bundles Steel Tanks Chilled Water Buffer Tanks System Efficiency Buffer Tanks Electric Boilers Stainless Compact Packaged Copper Coil Water Heaters - Semi-instantaneous, Instantaneous Unfired Steam Generators Condensed Catalog Cemline is represented in all major cities. Please contact your local representative or call Cemline Corporation. 2017 Cemline Corporation All Rights Reserved. All trademarks on this brochure are the property of Cemline Corporation, unless otherwise noted or in any other way set forth as a third party rights. Unauthorized use of these trademarks, as well as the materials presented on this site, is expressly prohibited and constitutes a violation of the intellectual property rights of Cemline Corporation. Vol. 6.1 Scan to view our mobile web link. CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448 www.cemline.com