Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

Similar documents
Typical Sample Preparation Process & Highlighted Areas for Horizon Technology SmartPrep Extractor Automation and XcelVap Evaporation

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

SmartPrep Automated SPE Cartridge Extractor II Module

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Systems. Visit us at

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

SPE-DEX Automated Extraction System. Users Guide

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

FREESTYLE QUATTRO ACCECLEAN ELUVAC GPC COLUMNS IMMUNOAFFINITY COLUMNS SAMPLE SAMPLE PREPARATION PRODUCTS PREP

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Thermo Scientific Dionex SolEx SPE Cartridges

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

From Sample to Vial. Automated Sample Prep Solutions. Extraction Cleanup Concentration

Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

On Line SPE LC/MS/MS Applications

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

Standard Operating Procedure for Oil & Grease Method EPA1664A

FORENSICS GLASS BLOCK MANIFOLD INNOVATION THROUGH CHEMISTRY

Reliable elimination of particles and micro organisms PAGE Protein Precipitation Fast and effective sample clean up of biological samples

300 series HPLC autosamplers

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Pretreatments to LLE

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

FREESTYLE always ready

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Environmental Parallel Evaporation Guide EPA Compliant Solvent Concentration

How Important is Performance to your SPE Method Development?

PROTOCOL FOR FREE LIPID SOP

Spark Holland introduces

Methods of solid phase extraction. Methods of solid phase extraction

GC Injectors. GC Injectors

William R. Jones, Zoe Grosser and Michael Ebitson Horizon Technology, Inc., Salem, NH, USA

LFL Monitoring. MEGTEC Systems

Soxtec 200 series Solvent Extraction Solution

APPLICATION NOTEBOOK FOR AFFINIMIP SPE

Scaled Down EPA Methods 8270 and 625 Solid Phase Extraction of 100 ml Samples or Less

For the successful distillation of heat sensitive materials

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Chromatography. Research Supplies. 2014/2015 Catalog

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

Solvent Evaporation. Fast, Reliable and Affordable

THE NEXT GENERATION CARBOY

P2 P2 P2 P3 P3 P3-4 P5 P5-p6 P6 P7 P7 P7-P8

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

Complete Gas Analysis

Laboratory Freeze Dryers Routine Applications

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Use of Automation to Achieve

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

TYPES AND APPROPRIATE INJECTORS

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Solid Phase Extraction (SPE) for the Analysis of Semivolatile. According to EPA Method 625. Derick Lucas, PhD R&D Sample Preparation Chemist

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Chemistry Instrumental Analysis Lecture 29. Chem 4631

160 EXTRACTION. Liquid/Liquid Extraction Apparatus. Continuous Liquid/Liquid Extraction with Built-in SLOW-DRY Concentrator

Accuracy Starts Here. Agilent Bond Elut Specialty, Disk and Bulk SPE Selection Guide

Virginia St. Jean, CIH Industrial Hygienist/DPH Green Programs Manager SF Hazardous Materials Unified Program Agency

Nexera-i Specifications Prominence-i Specifications

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Juan C. Feliciano Marvel Marchand Architects. Gowanus Green Master Plan: Reclaiming a Brownfield Site for NYC May 10 th, 2017

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

dcyrel Packaging Graphics Products

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

Revised: January 8, Goal: Deposit, expose, and develop standard positive photoresist films as an etch mask, liftoff mask, or sacrificial layer.

Cold Soak Filtration Test (CSFT) of Biodiesel. ASTM D IP PM EA - CEN N CGSB 3.0 No Range

RapidVap Dry Evaporation Systems

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Soxtherm. C. Gerhardt - Laboratory Instruments. Extraction Systems

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

Experiment 4: Purification of Liquids by Distillation

RESOLUTION OIV-OENO MONOGRAPH ON TANNINS UPDATE OF THE METHOD FOR DETERMINATION OF POLYPHENOLS

What cannot be cleaned in a stencil cleaner? Prepared by Steve Stach

SOXTHERM RAPID EXTRACTION

TECHNICAL DATA 3% AR-AFFF

PRODUCT LINE OVERVIEW CLEAN SAMPLE PREP

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

PRODUCT CONFORMITY CERTIFICATE

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Soft Ionisation Techniques, Terry Whitmore, Hiden Analytical

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

until filters are dry. Once dry, place the filters shiny side up in petrislides. The petrislide do NOT need to be acid washed.

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

Transcription:

S m a r t P r e p O i l & F u e l E x t ra c t o r S y s t e m s Solid phase extraction (SPE) of transformer oils, biofuels, edible, and essential oils can offer challenges of working with difficult matrices, multiple methods, and hazardous solvents. The SmartPrep Oil & Fuel Extractor systems are complete with racks, sample tubes, and accessories packaged to automate the typical manual SPE oil and fuel procedures, removing the challenges of working with oils and fuels, while providing a consistent and simple approach to running multiple methods on the same platform. Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation SmartPrep Extractor and in accordance with your developed methods or regulatory methods (i.e., EPA, FDA, USDA, AOAC and ISO). Monitor according to ASTM and IEC methods: Furan levels for maintenance and safety PCB levels to meet regulatory requirements for safety Perform analysis to meet formulation and quality tests: FAME and MAGs for biofuel quality requirements Oligosaccharides quantity for formulation research Regulate levels of contamination and determine quality: Label conformity ensures best product and quality Pesticides and PAHs are tested for trace levels

The Importance of Sample Preparation: integral part of final analysis quality and reliability in final data solid phase extraction (SPE) is commonly used for sample preparation due to its ability to use selective chemistry simplifying sample preparation is the first step to improving accuracy and reproducibility Typical Oil & Fuel Sample Preparation Process & Highlighted Areas for Horizon Technology SmartPrep Extractor Automation and XcelVap Evaporation for Drying Accuracy of SPE volume delivery over a standard curve range of atrazine (10 ng/l 500 ng/l) in water was evaluated. Atrazine, while banned in some countries, is a commonly used herbicide for the control of weeds in corn crops used to produce biofuels and edible oils. The % RSD for seven samples was <5%. P a ge 2

Diluted Transformer Oil Sample & Final SPE Fraction Polyaromatic Hydrocarbons (PAH) in Olive Oil Supelco SupelMIP SPE PAH Method 1. Condition with 1 ml cyclohexane 2. Load diluted oil sample 3. Wash with 1 ml cyclohexane 4. Elute with 3 x 1 ml ethyl acetate 5. Evaporate SPE eluate under nitrogen at 40 C and reconstitute in 0.2 ml ethyl acetate for analysis Automated with the SmartPrep Oil & Fuel Extractor Information from Supelco Analytical Application Note 192 Automated SPE - Furans in Transformer Oil 1. Condition cartridge using 5-mL of Hexane at 10-mL/min. Soak 5 sec Sample Dilution SPE Procedure Post SPE Cleanup 2. Clean Sample line using 5-mL of Hexane at 10-mL/min Dry 30 sec 3. Clean sample line using 5-mL of Hexane at 10-mL/min Dry 30 sec 4. Load 20-mL of sample at 3-mL/min. Deliver at 3-mL/min. 5. Wash cartridge using 20-mL of Hexane at 5-mL/min. Soak 10 sec, Dry 300 sec 6. Clean plunger using 6-mL of IPA at 10-mL/min 7. Clean plunger using 1-mL of VENT at 10-mL/min 8. Clean plunger using 6-mL of 20/80/ACN/H2O at 10-mL/min 9. Elute cartridge using 2.5-mL of 20/80 ACN/Water at 5-mL/min into 1st Collection Tube 10. Elute cartridge using 1-mL of VENT at 5-mL/min into 1st Collection Tube Soak 5 sec 11. Clean plunger using 6-mL of IPA of 10-mL/min. Soak 5 sec 12. Clean plunger using 6-mL of IPA at 10-mL/min. Soak 5 sec 13. Clean plunger using 1-mL of VENT at 5-mL/min P a ge 3

Common SPE Cartridges Used for Oil & Fuel Applications Sample Matrix Compounds Typical SPE Cartridge Transformer Oils Biofuels Furans per ASTM-D5837 or IEC 61198: 5H2F 2FOL 2FAL 2ACF 5M2F Polychlorinated biphenyls (PCBs) per ASTM-D4059 or EN 12766 Fatty Acid Methyl Esters (FAME) per modified ASTM D6584 Mono Acetyl Glycerides (MAGs) per modified ASTM D6584 Oligosaccharides Florisil /SCX dual layer Porous Graphitized Carbon (PGC) Tocopherols Polycyclic Aromatic Hydrocarbons (PAH) Organophosphorous pesticides Organochlorine pesticides MIPs Envi-carb, Diol PSA/C18 dual layer Tocopherols Tocotrienols Sterols C18 Edible Oils Beta Sitosterol Cation Exchange Phenolics C18, NH2 Phosopholipids, C18, Amino-propyl Chlorophyll pigments C18 Flavones Diol Lignans Diol Aflatoxin B1, B2, G1, G2 IAC,, MIPs Zearaleonone IAC, MIPs Essential Oils Alcohols and derivatives Hydrocarbons Carbonyl compounds Ethers Esters Tertiary alcohols Primary alcohols Acids Diols /Amino P a ge 4

The SmartPrep Oil & Fuel Extractor Systems are already configured to include the necessary components needed to order a complete system for automated SPE using either a 6-mL cartridge or a 3-mL cartridge. Order the system that fits the ASTM, EU, or SPE method(s) that will be automated. If both 6-mL and 3-mL cartridges will be used, just ask about the additional accessories to include. Quantity Part Number Description 6 ml System 1 SPE-2600 Kit, SmartPrep w/ 6 ml plunger 1 49-2807-02 Kit, SPE Start w/o controller 1 49-2810-13 Kit (12), Sip Tube, 5, Kynar 1 49-2810-12 Kit (12), Sip Tube, 10, Kynar 1 49-2816-01 Clear glass bottles w/ caps (500 ml case of 12) 1 49-2814-01 Kit, 3.1-micron inline filter 1 49-2600-04 6-mL cleaning cartridges 1 49-2812-01 Kit, 2x6 20-mL VOA collect rack 1 160-0008-02 Collection vials, 20-mL VOA vials (case of 72) 1 170-1000 Training at customer s facility 1 03-0100-01 50-mL conical bottom, graduated tube, case (12) 1 04-2003 50-mL conical rack 1 49-2818-03 20-liter plastic carboy for waste collection 1 99-2810 Containment Tray 1 Supplied via email ASTM and EU Furan Transformer Oil Software Methods 1 p/n Power cord appropriate for country 1 59-2824-08 Upgrade, Oil Waste Lines (FEP) 1 59-2825-08 Upgrade, Sample Valve Lines (FEP) Quantity Part Number Description 3 ml System 1 SPE-2300 Kit, SmartPrep w/ 3 ml plunger 1 49-2807-02 Kit, SPE Start w/o controller 1 49-2810-13 Kit (12), Sip Tube, 5, Kynar 1 49-2810-12 Kit (12), Sip Tube, 10, Kynar 1 49-2816-01 Clear glass bottles w/ caps (500 ml case of 12) 1 49-2814-01 Kit, 3.1-micron inline filter 1 49-2300-04 3-mL cleaning cartridges 1 49-2300-03 3-mL cartridge carousel insert adapters (15 Pk.) 1 49-2812-01 Kit, 2x6 20-mL VOA collect rack 1 160-0008-02 Collection vials, 20-mL VOA vials (case of 72) 1 170-1000 Training at customer s facility 1 03-0100-01 50-mL conical bottom, graduated tube, case (12) 1 04-2003 50-mL conical rack 1 49-2818-03 20-liter plastic carboy for waste collection 1 99-2810 Containment Tray 1 Supplied via email ASTM and EU Furan Transformer Oil Software Methods 1 p/n Power cord appropriate for country 1 59-2824-08 Upgrade, Oil Waste Lines (FEP) 1 59-2825-08 Upgrade, Sample Valve Lines (FEP) www.horizontechinc.com PN0011407_02 16 Northwestern Drive, Salem, NH 03079 USA Tel: (603) 893-3663 Email: Support-Service@horizontechinc.com