Datasheet - AZM 161SK-12/12RK-024

Similar documents
Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - TVS /B-M20

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A

SLC 220 E/R RFBS

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

One giant leap for safety: AZM400.

Conformity Approvals Rated insulation voltage Ui

PROTECT SRB 200EXi-1A

Overload relays. General descriptions. Configuration of the front

ISIS SAFETY SYSTEM Installation guide

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Original operating instructions Safety switch with guard locking AC901S AC902S

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Switches compliant with ATEX directive

Safety in system: Protection for man and machine Innovations 2016/2017

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

Multifunctional Gate Box MGB. More than safety.

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Soft Starter Centrifugal Pump Soft Starter Series

Stego accessories for cabinets

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SECTION AUTOMATIC TRANSFER SWITCHES

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

LOVAG TEST INSTRUCTION IEC/EN

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

RSGD. Three phase AC motor soft starter. Benefits. Description

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Operating Manual MS220KA and MSR220KA

Easy installation Certified for zones 1 and 21 High IP degree of protection

Flostop TS D7E and A8E. Operation Manual

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

MICRO SWITCH GSX Series

Safety Rope Pull Switches SRM, SR. General information on safety rope pull switches

Latch key safety limit switches Technical data

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

ATEX Safety Switches. More than safety.

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Technical Data. General specifications. Rated operating distance s n 5 mm

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Thermal Management Products & Accessories for Enclosures

BKA-EN Fire Damper. Additional operating instructions according to

Original instructions Sense7-series Non-contact coded safety switch

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

Technical Data. Dimensions

BERNSTEIN Safety Rope Pull Switches SR and SRM

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

INSTRUCTION MANUAL (ATEX / IECEx)

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Earth-Rite II PLUS Static Earthing System

SensaGuard TM Integrated Latch Installation Instructions

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Instructions for the fan motor control system with integrated wiring terminals SILVER C

DICTATOR Hold-Open Systems for Hazardous Areas

BSK-RPR Fire Damper. Additional operating instructions according to

RE-PR3-E-27 3-Phase Panel Mount 27kW

HMN-D2 Insert Series

Gas cylinder scale Model GCS-1

Original instructions JSNY7 Magnetic switch

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Power Supply Display Module PSDM. Installation and Operation Manual

Commercial and Light Industrial Fire Alarm Control Panel

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Flopurge TS. Operation Manual

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Basics of Safety Applications

UL HAZARDOUS LOCATIONS SERVICES

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

Snifter ATEX22 VERSION. User Manual. Distributor

Basics of Safety Applications

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Engineering Guideline. pac- Carriers Type Universal

Integrated Solutions Low Voltage Systems

Ordering Key. Dielectric strength

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

Flameproof Manual Call Points

Flameproof Manual Call Points Series MCP

BC3250. Blowdown Controller

new new Industrial plugs and sockets

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Transcription:

Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:21:41h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30 mm 6 Contacts Long life Large wiring compartment Manual release cable entries 4 M 16 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description AZM 161SK-12/12RK-024 Article number 1164207 EAN code 4030661205144 Approval Approval BG USA/CAN CCC Classification Standards EN ISO 13849-1 B10d Opener (NC) 2.000.000 Mission time 20 Years notice Global Properties Product name AZM 161 Standards EN 60947-5-1, BG-GS-ET-19 Compliance with the Directives (Y/N) Number of actuating directions Yes 3 piece

Active principle electromechanical Duty cycle Magnet 100 % Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, self-extinguishing - Material of the contacts Silver Housing coating None Weight 500 g Mechanical data Actuating play in direction of actuation 5.5 mm Design of electrical connection Screw connection Cable section - Min. Cable section 1 x 0,75 mm² - Max. Cable section 1 x 1.5 mm² Mechanical life > 1.000.000 operations Emergency unlocking device (Y/N) No Manual release (Y/N) Yes Emergency release (Y/N) No Latching force 30 N Positive break force 20 N positive break travel 10 mm Clamping force Fmax 2000 N Max. Actuating speed 2 m/s Actuating frequency max. 1000 / h notice All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature - Min. environmental temperature - 25 C - Max. environmental temperature + 60 C Protection class IP67 to IEC/EN 60529 Electrical data Design of control element Switching principle Number of auxiliary contacts Number of safety contacts Power to unlock Power to lock Rated control voltage Us Power consumption Rated impulse withstand voltage Uimp Rated insulation voltage Ui Thermal test current Ithe Normally open contact (NO), Opener (NC) Creep circuit element 2 piece 4 piece Yes No 24 VAC/DC max. 10 W 4 kv 250 V Utilisation category AC-15: 230 V / 4 A, DC-13: 24 V / 2,5 A Max. fuse rating 6 A gg D-fuse To DIN EN 60269-1 6 A ATEX Explosion protection categories for gases None

Explosion protected category for dusts None Miscellaneous data Applications sliding safety guard, removable guard, hinged safety guard Dimensions Dimensions of the sensor - Width of sensor 130 mm - Height of sensor 90 mm - Length of sensor 30 mm notice Manual release For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Switch travel diagram

Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZM 161SK-12/12RK-024G...G Protected against incorrect polarity and voltage spikes. limited terminating space 0,75 mm² Diagram 14 guard open 13 +24 VDC 63 0 VDC 64 unlocked Ordering code AZM 161 (1)-(2)(3)K(4)-(5)-(6)(7) (1) SK CC ST Screw connection Cage clamps male connector M12, 8- and 4-poles (Only for Us: 24 VAC/DC) (2) 12/12 2 Normally open contact (NO) / 4 Opener (NC) 12/11 2 Normally open contact (NO) / 3 Opener (NC) (Plug-in connection) 11/12 2 Normally open contact (NO) / 3 Opener (NC) (Plug-in connection) (3) without R (4) without A Latching force 5 N Latching force 30 N Power to unlock Power to lock (5)

without ED EU T TD TU N Manual release lateral Manual release cover-side Manual release rear Emergency exit lateral Emergency exit cover-side Emergency exit rear Emergency release (6) 024 Us: 24 VAC/DC 110/230 Us: 110/230 VAC (7) G with LED (Only for Us: 24 VAC/DC) Documents Operating instructions and Declaration of conformity (jp) 1 MB, 24.11.2010 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/jp/mrl_azm161_jp.pdf Operating instructions and Declaration of conformity (fr) 752 kb, 16.12.2009 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/fr/mrl_azm161_fr.pdf Operating instructions and Declaration of conformity (es) 711 kb, 16.12.2009 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/es/mrl_azm161_es.pdf Operating instructions and Declaration of conformity (en) 751 kb, 16.12.2009 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/en/mrl_azm161_en.pdf Operating instructions and Declaration of conformity (nl) 659 kb, 16.12.2009 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/nl/mrl_azm161_nl.pdf Operating instructions and Declaration of conformity (de) 421 kb, 17.02.2011 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/de/mrl_azm161_de.pdf Operating instructions and Declaration of conformity (it) 706 kb, 16.12.2009 http://127.0.0.1/bilddata/azm/pdf/azm161/bedien/azm_161_12_12/it/mrl_azm161_it.pdf BG-test certificate (de) 219 kb, 09.02.2010 http://127.0.0.1/bilddata/azm/pdf/azm161/baumuste/z_m16p01.pdf BG-test certificate (en) 219 kb, 09.02.2010 http://127.0.0.1/bilddata/azm/pdf/azm161/baumuste/z_m16p02.pdf CCC certification (en) 747 kb, 12.12.2006 http://127.0.0.1/bilddata/azm/pdf/azm161/zertifikat/q_371p02.pdf CCC certification (cn) 725 kb, 12.12.2006 http://127.0.0.1/bilddata/azm/pdf/azm161/zertifikat/q_371p03.pdf notice (de, en) 88 kb, 27.09.2007 http://127.0.0.1/bilddata/azm/pdf/azm161/sonder/s_161p01.pdf Images

Dimensional drawing (basic component) Dimensional drawing (basic component) Operating principle System components Actuator 1145117 - AZM 161-B1 1144416 - AZM 161-B1E

1171859 - AZM 161-B1ES 1175431 - AZM 161-B1F 1171125 - AZM 161-B1S 1173089 - AZM 161-B1-2053 WITH BALL LATCH 1164100 - AZM 161-B1-1747 WITH MAGNETIC LATCH 1178199 - AZM 161-B1-2024 1176642 - AZM 161-B1-2177 WITH CENTERING GUIDE

1174113 - AZM 161-B6-2177 WITH CENTERING GUIDE For very smal actuating radii 1170375 - AZM 161-B6S 1144420 - AZM 161-B6 For very smal actuating radii Door-handle system AZM 161-STS30 Latching handle Suitable for all types of guard Accessories 1100887 - TRIANGULAR KEY M5 For manual release using M5 triangular key, available as accessory For maintenance, installation, etc. K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 21.04.2011-14:21:42h Kasbase 1.4.7 DBI