Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

Similar documents
Series 65 Product Guide MAN 3036

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

XP95 ENGINEERING PRODUCT GUIDE

optical detector multisensor detector heat detector mounting bases product guide

ENGINEERING PRODUCT GUIDE

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

XP95 Product Guide MAN 3037

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Analogue addressable devices

Conventional Smoke Detectors KFAPO

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM

4 wire conventional alarm system

The supplier and installer of the system should be approved by the local civil defence authority.

XP95 Sounder VAD Base

Rules for Intruder Alarm Systems

Elite-A Analog Addressable Fire Control Panels (2 or 4 Loops) (Apollo Protocol)

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

5000 INSTALLATION GUIDE

Control Panel Engineering and Commissioning Instructions

Orbis IS Product Guide MAN 3041

Emergi-Lite Orbis detectors

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Product Guide MAN7030-2

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual

Installation, Operating and Maintenance Manual

An introduction to... Sigma

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

OH110, OP110, HI110 Automatic fire detectors

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Movement Detector GJD 300

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

RE-PR3-E-27 3-Phase Panel Mount 27kW

Conventional Fire Detection

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Evolution Analogue Addressable Fire System

UV Flame Supervision System

ALARMLINE ANALOGUE Linear Heat Detection System

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

The new detector from Rafiki

Reflective Optical Beam Smoke Detector User Guide

Reflective Beam Smoke Detector

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Door Release Power Supply

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

D-Tect 2 GJD300 Quad PIR Movement Detector

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

HART XL High Sensitivity Smoke Detection

EUROFLAT SERIES TYPES C... S... M...

EFBW series - BiWire Ultra control panel

Xenex Conventional Fire Detection & Alarm System

Class 1 laser beam sensor safe for your eyes

Audible warning devices for external alarm

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

SOUNDER CONTROL MODULE SCM-AS4

XP95 Intrinsically Safe Product Guide MAN 3054

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Flame Detector User Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Class 1 laser beam sensor safe for your eyes

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Interface Modules for SENTRI

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

General Routing Interface

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Technical data sheet TDS0060

INSTRUCTION MANUAL (ATEX / IECEx)

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Class 1 laser beam sensor safe for your eyes

On the job around the clock 24/7: Fire detection systems

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Laser Distance Sensor Type M Analog-Output

Flame Safeguards LFE10. Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

ALK-V PHOTOELECTRIC SMOKE SENSOR

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

FIRE DETECTION SYSTEMS. Product Guide

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

10yr O2NE & Safe-Ox. User Manual

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Transcription:

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

SERIES 60 CONVENTIONAL FIRE DETECTORS Series 60 is a range of conventional fi re detectors, designed for the highest effectiveness by utilising the latest technology. The range comprises ionisation, integrating ionisation and optical smoke detectors and a series of combined rate-of-rise and fi xed heat detectors. These detectors have been carefully researched by the Apollo design team and the range has undergone rigorous testing to ensure that it meets not only the European standards but also the demands of today s high-technology environments. This Product Guide aims to provide engineers with the fullest information on Series 60, in order to be able to design optimum solutions to fi re protection problems. Apollo Fire Detectors Ltd, part of the Halma plc group of companies, operates from one site at Havant, near Portsmouth, England. All departments - Research and Development, Sales and Marketing, Manufacturing and Finance - are located here. Apollo applies the most modern production techniques and has invested in sophisticated manufacturing equipment to ensure consistent high quality of product and fast response to customer requirements. Through planned expansion Apollo has reached a leading position in the market for professional fi re detectors and exports over half of its production to countries around the world. Information in this guide is given in good faith, but Apollo Fire Detectors Limited cannot be held responsible for any omission or errors. The company reserves the right to change specifi cations of products at any time and without prior notice. Apollo Fire Detectors was one of the fi rst companies in the fi re protection industry to be successfully assessed to the standard BS 5750, part 2 (ISO 9002/EN 29002) for quality assurance. In 1999, Apollo gained BS EN ISO: 9001: 1994 certifi cation from the Loss Prevention Certifi cation Board. 2

TABLE OF CONTENTS Series 60 Ionisation Smoke Detector Operating Principles Page 4 Electrical Description Page 5 Environmental Characteristics Page 5 Technical Data Page 7 Series 60 Optical Smoke Detector Operating Principles Page 8 Electrical Description Page 9 Environmental Characteristics Page 9 Technical Data Page 10 Series 60 Heat Detector Operating Principles Page 12 Electrical Description Page 12 Response Times Page 12 Technical Data Page 14 Mounting Base Page 16 Series 60 Relay Base Page 16 Other Base Variants Page 16 Mechanical Construction Page 17 Interchangeability Page 17 Control Panel Compatibility Page 17 Approvals Page 17 3

the reference and smoke chambers is the sensing electrode which is used to convert variations in the chamber currents into a voltage. When smoke particles enter the ionisation chamber ions become attached to them with the result that the current fl owing through the ionisation chamber decreases. This effect is greater in the smoke chamber than in the reference chamber and the imbalance causes the sensing electrode to go more positive. Series 60 Ionisation Smoke Detector Part no. 55000-200 SERIES 60 IONISATION SMOKE DETECTOR Operating Principles The Series 60 detector head has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Stainless steel wiper contacts connect the detector to the terminals in the mounting base. Inside the detector case is a printed circuit board which has the ionisation chamber system mounted on one side and the signal processing electronics on the other. The voltage on the sensing electrode is monitored by the sensor electronics and is processed to produce a signal which latches the detector into the alarm state when a preset threshold level is reached. At this point the supply current taken by the detector increases by a factor of 1,000. The ionisation detector is available in standard and integrating versions, each version having the same sensitivity. The integrating version has modifi ed signal processing circuitry which allows an alarm threshold to be present for up to 20 seconds without initiating an alarm. It is most suitable for use in areas where transient high levels of smoke may be expected. The part number for the integrating detector is 55000-210. PCB REFERENCE CHAMBER 10V ON FOIL HOLDER RADIOACTIVE FOIL CHIP CASE MOULDING The ionisation chamber system is an inner reference chamber contained inside an outer smoke chamber (Fig. 1). The outer smoke chamber has smoke inlet apertures which are fi tted with an insect resistant mesh. SENSING ELECTRODE INNER COVER LED LID MOULDING SMOKE CHAMBER The radioactive source holder and the outer smoke chamber are the positive and negative electrodes respectively. An Americium 241 radioactive source mounted within the inner reference chamber irradiates the air in both chambers to produce positive and negative ions. On applying a voltage across these electrodes an electric fi eld is formed. The ions are attracted to the electrode of the opposite sign, some ions collide and recombine, but the net result is that a small electric current fl ows between the electrodes. At the junction between Fig. 1 Sectional View Series 60 Ionisation Smoke Detector 0V 4

Electrical Description The detector is designed to be connected to a two wire monitored supply of between 17 and 28 volts dc. WIPER TEST POINT CASE MOULDING Connection to the supply is made in the mounting base between L1 and L2 and is polarity insensitive. Terminal L1 IN is a supply input terminal and it is connected to Terminal L1 OUT via the detector when fi tted. L1 OUT and L2 provide the supply output to the next detector on the zone or to the end of line device. This method of connection permits continuous monitoring of the supply through the detector and the end of line device. A remote alarm indicator may be connected between the positive supply line and -R terminal. The -R terminal is diode gated to protect it against accidental connection to the negative supply and to permit the connection of more than one detector to a single remote indicator. The current taken through the -R terminal should be externally limited to 23mA. The Apollo remote indicator part no. 53832-070 typically sinks 8mA and is suitable for direct connection between the positive supply and the -R terminals. It is not polarity sensitive and provides constant brightness over the supply range 8 to 28 volts to the detector. The control unit must be arranged to supply a maximum of 28 volts and a minimum of 6 volts (10mA) in the alarm condition to ensure correct operation of the detector. To ensure effective illumination of the indicator LED the supply to the detector should exceed 12 volts (25 ma). To restore the detector to the quiescent condition it is necessary to expel the smoke and interrupt the supply to the detector for a minimum of one second. The application of a slowly increasing voltage between the test point (Fig. 2) and negative supply line affects the ionisation chambers and causes the voltage at the sensing electrode to rise towards the preset reference voltage. This provides a test facility for use with an Apollo Series 60 test set. Fig. 2 Back View Series 60 Ionisation Smoke Detector. Environmental Characteristics The Series 60 ionisation smoke detector has been designed to operate over the temperature range 20 C to +60 C See Fig 3. Continuous wind speeds of up to 2m/s are permitted, and gusts of up to 10m/s can be tolerated without risk of false alarm. It is not recommended that the detector be installed in environments where a constant wind speed of greater than 2m/s is present. Ionisation detectors can also be affected by variations in atmospheric pressure due, for example, to the differences in height above sea level at which they are installed. Series 60 detectors show very little change in performance at heights up to 2,000 metres above sea level (Fig 5). Typical Quiescent and Alarm Currents Detector Status Supply Voltage (V) 28 24 17 10 6 Table 1 Quiescent Current (µa) 43 38 32 N/A N/A Alarm Current (ma) 61 52 37 18 8 Alarm (LED Fault) (ma) 54 46 33 16 7 5

Change in calibrated delta V (%) 40 20 0-20 -40-20 -10 0 10 20 30 40 50 60 Temperature (Deg. C) Fig. 3 Typical Temperature Response Series 60 Ionisation Smoke Detector Change in calibrated delta V (%) 40 20 0-20 -40 (m/s) 0 1 2 3 4 5 6 7 8 9 10 (ft/min) 200 400 600 800 1000 1200 1400 1600 1800 2000 (km/h) 5 10 15 20 25 30 35 (mph) 5 10 15 20 22.5 Fig. 4 Typical Wind Speed Response Series 60 Ionisation Smoke Detector Change in calibrated delta V (%) 40 20 0-20 -40-500 0 500 1000 1500 2000 2500 Height (m) Fig. 5 Typical Pressure Response Series 60 Ionisation Smoke Detector Safety Note In the United Kingdom ionisation smoke detectors are subject to the requirements of the Radioactive Substances Act 1993 and to the Ionising Radiations Regulations 1999 made under the provisions of the Health and Safety at Work Act 1974. The detectors have been independently tested by the National Radiological Protection Board (NRPB) and found to conform to all the requirements specifi ed in the Recommendations for ionisation chamber smoke detectors in implementation of radiation protection standards published by the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD) 1977. In summary, Apollo Series 60 ionisation detectors conform to all the requirements. There is no limit to the quantity that may be installed in any fi re protection system. Up to 500 detectors may be stored in any premises, although there are stipulations on storage facilities, if more than 100 ionisation detectors are to be stored in any one building. At the end of their useful life of 10 years Series 60 ionisation smoke detectors should be returned to Apollo for safe disposal. Guidance on storage and handling can be given by Apollo Fire Detectors and full details may be requested from: Radioactive Substances Regulation Function Environment Agency Rio House Waterside Drive Aztec West Almondsbury Bristol BS32 4UD Outside the UK, please contact the relevant agency. Note that Series 60 detectors are supplied in individual packing, with the red lid serving as a dust cover which can be left on the detector after fi tting to prevent the ingress of dust and dirt. The dust covers must be removed immediately prior to commissioning the system. 6

Technical Data - Ionisation Specifi cations are typical and given at 23 C and 50% relative humidity unless specifi ed otherwise. Detector Type: Products of combustion (smoke) detector. Detection Principle: Ionisation chamber. Chamber Configuration: Twin compensating chambers using one single sided ionising radiation source. Radioactive Isotope: Americium 241. Activity: 33.3 k Becquerels, 0.9 µcie. Supply Wiring: Two wire monitored supply, polarity insensitive. Terminal Functions: L1 IN and L2: supply in connections (polarity insensitive). L1 OUT and L2: supply out connections (polarity insensitive). R: remote indicator negative connection. Supply Voltage: 17 to 28V DC. Ripple Voltage: 2V peak to peak maximum at 0.1Hz to 100kHz. Quiescent Current: 30 to 45µA at 24V Switch-on Surge Current: 80µA Alarm Voltage: 6 to 28V Normal Alarm Current: 61mA at 28V 52mA at 24V 18mA at 10V Alarm Indicator: Red Light Emitting Diode (LED) Design Alarm Load: 450Ω in series with a 3V drop (LED open circuit). Holding Voltage: 6V (min). Holding Current: 10mA (min) Minimum Voltage Required to Illuminate Indicator: 12V Alarm Reset Voltage: 1V Alarm Reset Time: 1 second Remote Output Characteristics: 900Ω in series with a 3V drop at 24V with 500Ω line impedance gives: 1mA at 9V 4.5mA at 5V 8.0mA at 1V Calibration: Factory set to ΔV of 1.3V. Sensitivity: Nominal threshold Y value of 0.7 to Part 7 1984; (BS 5445 Part 7 1984). Temperature Range: Maximum continuous operating temperature 60 C Minimum continuous operating temperature 0 C Minimum operating temperature 20 C (no condensation or icing) Temperature Compensation: Automatic compensation by dual chambers to comply with EN 54 Part 7 1984; (BS 5445 Part 7 1984) across the operating temperature range. Humidity: 0% to 95% relative humidity. Atmospheric Pressure: Automatic compensation by dual chambers to maintain sensitivity up to a height of 2000m. 7

Wind Speed: 2 m/s maximum (constant) 10 m/s maximum (transient) Vibration: To EN 54 Part 7 1984 (BS 5445 Part 7 1984). Impact: To EN 54 Part 7 1984 (BS 5445 Part 7 1984). Shock: To EN 54 Part 7 1984 (BS 5445 Part 7 1984). Static: IEC 801-2 (BS 6667 Part 2 1985) Severity Level 3. Tested to 12,000V positive and negative to the case and supply terminals from a 250pF capacitor. Radiated Emissions: BS 6527 Class B. Radiated Susceptibility: IEC 801 Part 3 Class 3 (10V/m). Tested to 90V/m from 27MHz to 1GHz. IP Rating: 43. Dimensions: Detector: 100mm x 42mm (diameter x height) Detector in Base: 100mm x 50mm (diameter x height) Weights: Detector: Detector in Base: Materials: Detector housing: Terminals: marked 102 grams. 153 grams. White polycarbonate V-O rated to UL 94. Stainless steel. Series 60 Optical Smoke Detector Part no. 55000-300 SERIES 60 OPTICAL SMOKE DETECTOR Operating Principles The Series 60 optical smoke detector comprises a sensing chamber and a printed circuit board within a white polycarbonate housing. The sensing chamber is a black moulding confi gured as a labyrinth which prevents ambient light penetrating into the chamber. The labyrinth has a fi ne gauze cover to prevent insects from migrating into the chamber. Within the chamber is an optical arrangement consisting of two main parts: an infra-red light emitting diode and a photo-diode (Fig. 6). The LED is positioned at an obtuse angle to the photodiode, which has an integral daylight fi lter for further protection against ambient light. The LED emits a burst of collimated light every 10 seconds. In clean air conditions the photo-diode will not receive light particles photons due to the collimation of the light and the angle at which the light is travelling relative to the photo-diode. When smoke enters the chamber, it scatters photons onto the photo-diode to excite it into activity. The LED then emits two further bursts of light, this time at 2-second intervals. If light is scattered onto the photo-diode on both these pulses due to the presence of smoke the detector will change to the 8

alarm state when a silicon controlled rectifi er on the printed circuit board is switched on and the current drawn by the detector is increased from an average of 40 microamps to a maximum of 61 milliamps. To ensure maximum reliability, the LED emits light modulated at about 3kHz and the photo-diode will react only on receiving light at this frequency. sensitive and provides constant brightness over the supply range 8 to 28 volts to the detector. The control unit must be arranged to supply a maximum of 28 volts and a minimum of 6 volts (10 ma) in the alarm condition for correct operation of the detector. To ensure effective illumination of the indicator LED the supply to the detector should exceed 12 volts (25 ma). OPTICAL CHAMBER PCB COVER CASE MOULDING PHOTO-DIODE INFRA-RED LED To restore the detector to the standby condition it is necessary to expel the smoke and interrupt the supply to the detector for a minimum of one second. Environmental Characteristics The Series 60 optical smoke detector is unaffected by wind or pressure and operates over the temperature range 20 C to 60 C (Fig. 7). Change in calibrated gain (%) Fig. 6 Top Section Series 60 Optical Smoke Detector Electrical Description The detector is designed to be connected to a two wire monitored supply of between 17 and 28 volts dc. Connection to the supply is made in the mounting base between L1 and L2 and is polarity insensitive. Terminal L1 IN is a supply input terminal and it is connected to Terminal L1 OUT via the detector when fi tted. L1 OUT and L2 provide the supply output to the next detector on the zone or to the end of the line device. This method of connection permits continuous monitoring of the supply through the detector and the end of line device. 40 20 0-20 -40-20 -10 0 10 20 30 40 50 Temperature (Deg. C) Fig. 7 Typical Temperature Response Series 60 Optical Smoke Detector A remote alarm indicator may be connected between the positive supply line and the R terminal. The R terminal is diode gated to protect it against accidental connection to the negative supply and to permit the connection of more than one detector to a single remote indicator. The current taken through the R terminal should be externally limited to 23 ma. The Apollo remote indicator part no. 53832-070 typically sinks 8mA and is suitable for direct connection between the positive supply and the R terminals. It is not polarity 9

Technical Data - Optical Specifi cations are typical and given at 23 C and 50% relative humidity unless specifi ed. Detector type: Products of combustion (smoke) detector. Detector Principle: Photo-electric detection of light scattered in a forward direction by smoke particles. Chamber Configuration: Horizontal optical bench housing an infra-red emitter and sensor arranged radially to detect forward scattered light. Sensor: Silicon PIN photo-diode. Emitter: GaAs Infra-red light emitting diode. Sampling Frequency: Once every 10 seconds. Confirmation Frequency: Once every 2 seconds. Number of Consecutive Sensed Alarm Signals Needed To Trigger Detector Alarm: 3. Supply Wiring: Two-wire monitored supply, polarity insensitive. Terminal Functions: L1 IN and L2; supply in connections (polarity insensitive). L1 OUT and L2; supply out connections (polarity insensitive). R; remote indicator negative connection. Supply Voltage: 17 to 28V DC. Ripple Voltage: 2V peak to peak maximum at 0.1Hz to 100kHz. Quiescent Current: 30 to 45μA at 24V. Switch on Surge Current: 90μA at 24V. Alarm Voltage: 6 to 28V. Normal Alarm Current: 61 ma at 28V. 52 ma at 24V. 18 ma at 10V. Alarm Indicator: Clear Light Emitting Diode (LED) emitting red light. Design Alarm Load: 450Ω in series with 3V drop (LED open circuit). Holding Voltage: 6V (min). Holding Current: 10mA (min). Minimum Voltage Required to Light Alarm Indicator: 12V. Alarm Reset Voltage: 1V. Alarm Reset Time: 1 second. Remote Output Characteristics: 900Ω in series with a 3V drop at 24V with 500Ω line impedance gives: 1mA at 9V 4.5mA at 5V 8.0mA at 1V Sensitivity: Nominal threshold of 3.0% light grey smoke obscuration per metre to EN 54 Part 7 1984; (BS 5445 Part 7 1984). Temperature Range: 20 to +60 C (no condensation or icing). Temperature Compensation: Negative temperature coeffi cient thermistor. Humidity: 0% to 95% relative humidity (no condensation) Wind Speed: Insensitive to wind. 10

Atmospheric Pressure: Insensitive to atmospheric pressure. Vibration: To EN 54 Part 7 1984 (BS 5445 Part 7 1984). Impact: To EN 54 Part 7 1984 (BS 5445 Part 7 1984). Shock: To EN 54 Part 7 1984 (BS 5445 Part 7 1984). Typical Quiescent and Alarm Currents Detector Status Supply Voltage (V) 28 24 17 10 6 Table 2 Average Standby Current (µa) 38 37 35 N/A N/A Pulse Current Maximum (µa) 110 90 60 N/A N/A Smoke Alarm Current (ma) 61 52 37 18 8 Smoke Alarm (LED Fault) (ma) 54 46 33 16 7 Static: IEC 801-2 (BS 6667 Part 2 1985). Severity Level 3. Tested to 12,000 Vpositive and negative to the case and supply terminals from a 250pF capacitor. Radiated Emissions: BS 6527 Class B. Radiated Susceptibility: IEC 801 Part 3 Class 3 (10 V/m). Tested to 65 V/m from 27MHz to 1GHz. IP Rating: 43. Dimensions: Detector: 100mm x 42mm (diameter x height). Detector in Base: 100mm x 50mm (diameter x height). Weights: Detector: Detector in Base: Materials: Detector housing: Terminals: 99 grams. 150 grams. White polycarbonate V-O rated to UL 94. Stainless steel. marked 11

thermistor becomes signifi cant. When the sum of the resistances of the insulated thermistor and fi xed resistor compared to the resistance of the exposed thermistor reaches a preset ratio, an alarm is initiated. The value of the fi xed resistor is selected so that the detector goes into the alarm state at a specifi ed fi xed temperature value. Electrical Description The detector is designed to be connected to a two wire monitored supply of between 17 and 28 volts dc. Series 60 Heat Detector Part no. 55000-100 Grade 1 55000-101 Grade 2 55000-102 Grade 3 55000-103 Range 1 55000-104 Range 2 SERIES 60 HEAT DETECTOR Operating Principles The Series 60 heat detector contains a pair of matched negative temperature coeffi cient thermistors mounted on a printed circuit board within a white polycarbonate housing. One thermistor is exposed and is therefore in good thermal contact with the surrounding air and responds quickly to changes in air temperature. The other thermistor is insulated from the surrounding air and responds more slowly. Under stable conditions, both thermistors are in thermal equilibrium with the surrounding air and will have the same resistance value. If the air temperature increases rapidly then a temperature difference develops between the thermistors and the resistance of the exposed thermistor becomes less than that of the insulated thermistor. The ratio of the resistances of the thermistors is monitored electronically and a fi re alarm is initiated if the ratio exceeds a factory preset level. This feature of the operating principle determines the rate of rise response of the detector. If the air temperature increases slowly, no signifi cant temperature difference develops between the thermistors. However, at high temperatures a fi xed value resistor, connected in series with the insulated Connection to the supply is made in the mounting base between L1 and L2 and is polarity insensitive. Terminal L1 IN is a supply input terminal and it is connected to Terminal L1 OUT via the detector when fi tted. L1 OUT and L2 provide the supply output to the next detector on the zone or to the end of line device. This method of connection permits continuous monitoring of the supply through the detector and the end of line device. A remote alarm indicator may be connected between the positive supply line and the R terminal. The R terminal is diode gated to protect it against accidental connection to the negative supply and to permit the connection of more than one detector to a single remote indicator. The current taken through the R terminal should be externally limited to 23mA. The Apollo remote indicator part no. 53832-070 typically sinks 8mA and is suitable for direct connection between the positive supply and the R terminals. It is not polarity sensitive and provides constant brightness over the supply range 8 to 28 volts to the detector. A one-second interruption of the supply to a detector will reset the detector s alarm circuit and restore it to the standby condition, provided that normal temperature conditions have been restored. Response Times The European Standard EN 54 (BS 5445) categorises heat detector according to their response times and fi xed upper limits. Detectors are classifi ed as being Grades 1, 2 or 3 (for most normal applications) or Ranges 1 or 2 (for high temperature environments). 12

The fi xed upper temperatures for Grades 1, 2 and 3 are 60 C, 65 C and 75 C respectively and for Ranges 1 and 2 80 C and 100 C. All have a rate of rise element, but this differs according to the response time, Grade 1 being fastest responding. EN 54 lays down upper and lower response limits for each detector grade or range and Apollo has set limits for the response of Series 60 detectors within these parameters. Figures 8 12 show the EN 54 limits for each type of detector, in terms of the temperature at which the detector will change to alarm at different rates of increase in temperature, and the time taken to reach the alarm level. The response of Series 60 heat detectors is shown within these limits. Alarm Temperature ( C) 110 100 90 80 70 60 50 40 30 Fig. 10 110 Grade 3 75 C Heat Detector * ROR C/min Lower Limit (Part 5) Upper Limit Typical Response Apollo Series 60 Grade 3 1 29 : 00 51 : 12 3 7 : 13 16 : 31 5 4 : 09 9 : 10 10 0 : 30 4 : 25 20 0 : 22.5 2 : 24 30 0 : 15 1 : 46 * Initial Temperature 25 C Upper Limit 54 : 00 18 : 40 11 : 36 6 : 18 3 : 37 2 : 42 Lower Limit 0 1 3 5 10 20 30 Rate of Rise of Temperature ( C/min) Range 1 80 C Heat Detector (Part 8) Upper Limit Alarm Temperature ( C) 80 70 60 50 40 30 Grade 1 60 C Heat Detector * ROR C/min Lower Limit (Part 5) Upper Limit Apollo Series 60 Grade 1 Typical Response Upper Limit 1 29 : 00 34 : 11 37 : 20 3 7 : 13 9 : 33 12 : 40 5 4 : 09 5 : 24 7 : 44 10 0 : 30 2 : 52 4 : 02 20 0 : 22.5 1 : 42 2 : 11 30 0 : 15 1 : 17 1 : 34 *Initial Temperature 25 C Lower Limit Alarm Temperature ( C) 100 90 80 70 Fig. 11 * ROR C/min Lower Limit Apollo Series 60 Range 1 Typical Response Upper Limit 1 29 : 00 37 : 07 45 : 40 3 7 : 13 11 : 47 15 : 40 5 4 : 09 7 : 06 9 : 40 10 2 : 00 3 : 51 5 : 10 20 0 : 59 2 : 11 2 : 55 30 0 : 39 1 : 38 2 : 08 * Initial Temperature 45 C Lower Limit 60 0 1 3 5 10 20 30 Rate of Rise of Temperature ( C/min) Alarm Temperature ( C) 20 0 1 3 5 10 20 30 Rate of Rise of Temperature ( C/min) Fig. 8 90 80 70 60 50 40 Grade 2 65 C Heat Detector * ROR C/min 1 3 5 10 20 30 Lower Limit 29 : 00 7 : 13 4 : 09 0 : 30 0 : 22.5 0 : 15 * Initial Temperature 25 C (Part 5) Upper Limit Typical Response Apollo Series 60 Grade 2 38 : 41 10 : 29 6 : 03 3 : 01 1 : 46 1 : 20 Upper Limit 45 : 40 15 : 40 9 : 40 5 : 10 2 : 55 2 : 08 Lower Limit Alarm Temperature ( C) 130 120 110 100 90 Fig. 12 Range 2 100 C Heat Detector * ROR C/min Lower Limit Apollo Series 60 Range 2 1 29 : 00 35 : 15 3 7 : 13 12 : 01 5 4 : 09 7 : 24 10 2 : 00 3 : 59 20 0 : 59 2 : 15 30 0 : 39 1 : 41 * Initial Temperature 65 C (Part 8) Upper Limit Typical Response Upper Limit 45 : 40 15 : 40 9 : 40 5 : 10 2 : 55 2 : 08 Lower Limit 80 0 1 3 5 10 20 30 Rate of Rise of Temperature ( C/min) 30 0 1 3 5 10 20 30 Rate of Rise of Temperature ( C/min) Fig. 9 13

Technical Data - Heat Specifi cations are typical and given at 23 C unless otherwise specifi ed. Detector Type: Rate of rise heat detectors Supply Wiring: Two wire monitored supply, polarity insensitive. Terminal Functions: L1 IN and L2; supply in connections (polarity insensitive). L1 OUT and L2; supply out connections (polarity insensitive). R; remote indicator negative connection. Supply Voltage: 17 to 28V Ripple Voltage: 2V peak to peak maximum at 0.1Hz to 100kHz. Quiescent Current: All types: 51µA +/ 2µA, at 24V. Switch-on Surge Current: As per Quiescent Current Alarm Voltage: 6 to 28V. Alarm Current: 50 52mA at 24V. Alarm Indicator: Red Light Emitting Diode (LED). Design Alarm Load: 450Ω in series with a 3V drop (LED open circuit). Holding Voltage: 6V. Holding Current: 10mA. Minimum Voltage Required to Light Alarm Indicator: 12V. Remote Output Characteristics: 900Ω in series with a 3 V drop at 24V with 500Ω line impedance gives: 1mA at 9V 4.5mA at 5V 8.0mA at 1V Storage Temperature Range: 30 C to 120 C. Operating Temperature: 20 C to +90 C (no icing) Humidity: 0% to 95% relative humidity. Atmospheric Pressure: Unaffected. Vibration: To EN 54 Part 5/8 (BS 5445 Part 5/8). Impact: To EN 54 Part 5/8 (BS 5445 Part 5/8). Shock: To EN 54 Part 5/8 (BS 5445 Part 5/8). Static: 12,000V positive or negative to case and supply terminals from 250pF capacitor at 50% relative humidity. Radiated Emissions: To BS 6527 Class B. Radiated Susceptibility: To IEC 801 (BS 6667) Part 3 Class 3. Tested to 75 Volts/metre from 27 MHZ to 1 GHz. IP Rating: 54 Dimensions: Detector: 100mm x 42mm (Diameter x Height). Detector in Base: 100mm x 50mm (Diameter x Height). Weights: Detector: Detector in Base: 80 grams. 131 grams. marked 14

Typical Quiescent and Alarm Currents Detector Status Supply Voltage (V) Quiescent Current µa Alarm Current ma G1 G2 G3 R1 R2 Table 3 28 24 17 10 6 55 56 56 56 57 50 51 51 51 52 42 43 43 43 44 26 26 26 27 27 12 13 13 13 13 62 52 36 19 10 Heat detectors are readily distinguished from smoke detectors by having open webs to allow the free movement of air around the exposed thermistor. For ease of identifi cation Series 60 heat detectors are colour or number coded (see Table 4). Heat Detector Identification Coding Table 4 Detector Grade 1 Grade 2 Grade 3 Range 1 Range 2 Identification Green label Yellow label Red label 80 100 15

For conventional systems that are designed to operate correctly when one or more detector heads have been removed, a base fi tted with a diode on line 1 is available, part no. 45681-201. Remote LED + L1 IN R L1 IN R L1 IN R From control panel L1OUT EARTH L2 L1OUT EARTH L2 L1OUT End-of-line device EARTH L2 Fig. 13 Schematic Wiring Diagram of Series 60 Monitored Detector Circuit Series 60 Mounting Base Part no. 45681-200 SERIES 60 MOUNTING BASE All detectors in the Series 60 range will fi t into a new design of mounting base with a diameter of 100mm. The base has fi ve terminals: Line 1 in, Line 1 out, Line 2 in and out, Remote LED negative and ground. The detectors are polarity insensitive, so that identifi cation of the positive and negative lines is required only when connecting a remote LED. A ground connection is not required either for safety or the correct operation of detectors. The grounded terminal is provided only for the tidy termination of grounded conductors and maintaining ground continuity between cables which contain a grounded conductor. All terminals are marked as to their function. Series 60 bases have a wide interior diameter for ease of access to wires and terminals and two slots for fi xing screws such that two screws may be fi tted at any distance between 51mm and 69mm from each other. The design of the base is such that the detector will fi t in one way only, without snagging, and that a simple clockwise motion without push force is required to plug in a detector. When fi tting a detector to a base in a confi ned space, 110mm of space, measured from the surface to which the base is fi tted, should be allowed for fi tting and removal. + From control panel L1 IN L1OUT EARTHL2 R EARTH L2 Note: Polarity should be observed on detectors beyond the one driving the remote indicator. Earth terminal is provided for easier installation and is not required by the detector head. SERIES 60 RELAY BASE The Series 60 relay base part no. 45681-360 is an extended version of the standard Series 60 base and incorporates a single-pole voltagefree changeover contact for switching ancillary equipment. The maximum contact switching voltage is 50V. When the detector changes to the alarm state, the relay is energised, causing the contact to change state from normally open to closed or from normally closed to open. The contact will remain in this condition until the detector is re-set. OTHER BASE VARIANTS A number of mounting accessories and base variants, including 150mm (6 inch) bases are available. Details are provided in Apollo publication PP1089, which is available on request. L1 IN L1OUT R L1 IN R L1OUT End-of-line device EARTH L2 Fig. 14 Schematic Wiring Diagram of Series 60 Monitored Detector Circuit with a Common Remote Indicator. 16

MECHANICAL CONSTRUCTION All detectors in the Series 60 range have the same external dimensions, with the housing of the ionisation and optical detectors being identical. The material used to mould the housings is a UL 94 V-O grade of polycarbonate in a pure white fi nish. The external alarm indication is by means of a lightemitting diode (LED) mounted on the printed circuit board within the housing and protruding through the housing to be easily visible. The LED on the ionisation smoke detector is red, whereas the optical smoke detector is distinguished by having a clear LED which emits red light on changing to the alarm state. All detectors in the Series 60 range have four stainless steel wipers at the top of the housing which make electrical contact with the double terminals when the detector is fi tted to the standard Series 60 base. Both ionisation and optical smoke detectors have an interior shield fi tted for increased protection against radio frequency interference emitted by external electronic devices. INTERCHANGEABILITY Any detector in the Series 60 range may be replaced with any other type in the range. If, for example, a smoke detector proved unsuitable for a particular application, it could simply be replaced with a heat detector. CONTROL PANEL COMPATIBILITY Series 60 has been designed to be connected to any conventional control panel that will operate existing ranges of Apollo conventional detectors. Guidelines for proving compatibility between control panels and Apollo detectors may be obtained from Apollo. When engineering systems with Series 60, it should be borne in mind that the alarm impedance of a detector be considered as 450 Ohms in series with a 3 volt drop with LED open circuit. Typical current against voltage characteristics for quiescent and alarm states are shown in Tables 1, 2 and 3. APPROVALS Series 60 detectors have been designed to comply with (BS 5445) as well as UL standards. They comply with EMC directive 89/336/EEC and are CE marked. The detectors have been approved by a number of approvals bodies throughout the world including LPCB in the UK and VdS in Germany. Series 60A detectors are UL Listed. The bases are designed specifi cally for Series 60 detectors and will not accept devices from other Apollo product ranges, including earlier Apollo models. 17

PP2103/2004/Issue 4 Equivalent to printed version PP1050 Apollo Fire Detectors Limited 1992 2004 Assessed to ISO 9001: 2000 Certificate number 010 36 Brookside Road, Havant, Hampshire, PO9 1JR, UK Tel: +44 (0) 23 9249 2412 Fax: +44 (0)23 9249 2754 Email: sales@apollo-fire.co.uk Website: www.apollo-fire.co.uk