A REVOLUTIONARY APPROACH TO FIRE SAFETY

Similar documents
CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

PRODUCT SPECIFICATION FireMaster Plus

Firetex steel fire shutters

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

WARNING FIRE DOOR CLOSING

Technical Manual (European Standards)

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

PRODUCT SPECIFICATION FireMaster Plus Concertina

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FIRE & SMOKE CURTAINS

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER CONCERTINA TM

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIRE & SMOKE CURTAINS

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

MINERVA MX. 800 Series Ancillary Equipment

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

A Guide To BS Understanding the selection, spacing and siting of detectors

Intelligent Security & Fire Ltd

Conventional Fire Detection

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SMOKE AND FIRE CURTAINS

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

MINERVA MZX125 Digital Addressable Fire Detection System

Operation & Maintenance Manual

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Application, Installation, Operation & Maintenance Manual

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Smoke and Fire Curtains

Data Sheet. Abacus intruder alarm systems

enhance your view Manufactured Your local Liniar stockist: For more information and to find your nearest fabricator visit

Sita200plus. 200detectors. Single loop analogue addressable System

Fire Command Keypad. XR5 User s Guide

intelligent solutions

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Intelligent Security & Fire Ltd

Reflective Optical Beam Smoke Detector User Guide

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Contents. Glossary

User s Information Guide R2A

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Gas interlock system S & 100 CS

The EN54 Part 2 & 4 Fire System

Fire detection and alarm

Building Technologies

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Reference information

Working in Partnership with our Customers.

Control Panel User Guide

Control box FSTronic DES-FS

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ECONX FIT OFF INSTRUCTIONS

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Control Panel User Guide (TO BE RETAINED BY THE USER)

Brochure. Security Designed, Installed by Experts

All by design. ASSA ABLOY Door Controls

KFP-CF Series Operation Manual

Flame Shutter & Flame Curtain Price List

Commercial. Tel:

Fire Signalling. Signalling Solutions

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SECURIT 700L USER MANUAL

Specified Systems List

Fire Risk Assessment Nelson Cottage Bed & Breakfast

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

MINERVA MZX125. Digital Addressable Fire Detection System

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

Installation Manual Premier 412/816/832. Issue 10

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

5 Sounds and Indications

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Security System. User Guide for the LED Command Center

Fire Precautions, Evacuation and Emergency Control Procedure Denmead Scouts HQ

Conventional Fire Alarm System 2014 V1.2

The EN54 Part 2 and 4 Fire System

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

Transcription:

Fire Curtains Fire Rated Shutters Smoke Curtains DC FIRE Motors A REVOLUTIONARY APPROACH TO FIRE SAFETY Unique Patented Technology for the 21st Century WWW.NECOFIREGARD.COM

WELCOME TO NECO FIRE GARD Founded over 10 years ago, NECO Fire Gard is a leading provider of fire safety solutions for small and large businesses within the retail, hospitality, transport, aviation and construction industries. We specialise in the manufacture, supply and installation of a wide range of Fire Curtains, Smoke Curtains and Fire Rated Roller Shutters. We are committed to investing heavily in research and development to ensure we continue to deliver innovative, industry-leading products and services which exceed the scrupulous standards demanded by the Fire Safety Industry in the UK and Internationally. Customer service is of paramount importance to us. We pride ourselves on providing a bespoke personalised service, working in partnership with customers to deliver cost-effective fire and smoke safety solutions from specification, to installation and maintenance. To find out more about how we can help you please contact our Sales Team via email: info@necogroup.eu or call on 02920 668 332 www.necofiregard.com

DC Gravity & Controlled Descent and Non-Gravity Fail-Safe Tubular Motors FEATURES TECHNICAL INFORMATION Lifting capacity up to 200kg Gravity Fail-Safe feature available on models: DC55G, DC55G-25, DC80G, DC80G-19 & DC95G Suitable for use with Fire/Smoke Curtains, Fire Shutters and High Usage Doors Tested and approved by Exova, Warringtonfire DC55 DC55G DC55G-25 DC80 DC80G DC80G-19 DC95 DC95G Voltage 24v 24v 24V 24v 24v 24v 24v 24v Current 3.2a 3.2a 3.2a 8.5a 8.5a 8.5a 10.8a 10.8a Running Time 30min 30min 30min 30min 30min 30min 30min 30min Torque 30nm 15nm 25nm 80nm 80nm 30nm 120nm 100nm RPM 18rpm 40rpm 25rpm 12rpm 12rpm 19rpm 10rpm 8rpm Drop Weight n/a 10kg 20kg n/a 20kg 10kg n/a 25kg Lifting Capacity 50kg 15kg 15kg 100kg 80kg 40kg 200kg 100kg DC110 DC120 DC140 DC140Q DC160 Voltage 24v 24v 24v 24v 24v Current 10.8a 19.8a 18.5a 19.8a 14.6a Running Time 30min 30min 30min 30min 30min Torque 200nm 380nm 420nm 600nm 600nm RPM 10rpm 8rpm 6.5rpm 140rpm 4.2rpm Lifting Capacity 300kg 400kg 600kg 50kg 800kg

NECO DC Fire Control Panel HIGHLIGHTS Up to 96 hours of battery back-up Volt-free fire alarm connection Additional battery back-up Includes the NECO DC Tubular Motor & the NECO Group Controller Only compatible with the NECO DC Tubular Motor DESCRIPTION The Neco DC Fire Control Panel is the heart of our range of Neco Fire Curtains, Smoke Curtains and Fire Shutters. It offers many features which deliver full control with all site situations. FEATURES Electronic Limits A fire/smoke curtain can be commissioned without gaining access to the motor. All limits are set from the control panel. If you need to return to site to commission your fire/smoke curtain, only one engineer is required. Battery Back-Up: If the power supply fails, the inbuilt battery back-up system maintains operation of the fire/smoke curtain until the power is restored (up to 96 hours). Audio Visual A full audio siren and flashing beacon are supplied. These can be (dis)connected depending on the site requirements. Split Drop Delay Once the alarm is activated, the fire/smoke curtain will descend to the middle split drop limit and remain in this position for up to 16 minutes. It acts as a smoke curtain and prevents the spread of smoke, allowing people to escape before it descends to the floor. Delay Before Descent Once the fire alarm is activated, the curtain will remain in the up position ensuring the safe evacuation of the building. After a set period of time (up to 16 minutes), it will automatically close.

FEATURES Continued... Deadman and Auto Operation The control panel can be placed in either automatic operation up or automatic operation down, or automatic operation up and deadman down. Auto Return Reset Function Once the fire alarm is activated, the fire/smoke curtain will descend to the floor. It will remain in this position whilst the alarm is activated. Once the alarm is reset, the curtain will automatically return to the open position. This feature is important where numerous fire/ smoke curtains are installed. All the curtains will return to the open position without having to raise each individual curtain. Emergency Retract If the fire/smoke curtain is activated a trapped person can press the emergency switch and raise the curtain to escape to the nearest fire exit. Volt Free Fire Alarm Connection The control panel is designed to receive a volt free fire alarm signal. This can open or close. Double Knock Fire Activation The control panel can operate a double knock fire alarm activation. This means that when the fire alarm is activated the curtain will descend to the split drop delay limit and act as a smoke curtain only. The fire curtain will only reach the floor once a second signal is received either from a second fire signal or a stand alone relay based smoke or heat detector. Building Management System The control panel can connect the fire curtains to connect to a building management system. This allows a person in a control room or designated area to monitor all the fire/smoke curtains. For example, if the fire alarm is activated the relevant person can check to see if all curtains have descended without having to walk around the building. Obstacle Detection A photo cell can be attached to the fire/smoke curtain with a flashing beacon and sounder and connect to the control panel. This means that if an object is placed under the curtain the alarm will sound until the object is removed.

NECO DC Group Controller FEATURES Simultaneously operates up to 20 motors Only compatible with NECO DC Tubular Motors Suitable for all commercial and retail sites/ premises DESCRIPTION The NECO DC Group Controller can be connected to the NECO fire curtain system. Fire Curtain Systems +6 meters wide The group controller can operate multiple rollers connected to one fire curtain system once the fire alarm is activated. Multiple Fire Curtains Where multiple fire curtains are fitted across a site, the group control panel operates them at the same time. Fire Alarm If only one fire alarm connection is available, all the fire curtains can be connected through the group control panel.

NECO Fire Gard Fire Curtain FEATURES Offers up to 4 hours fire and smoke protection Made with NECO 240+ Fabric or NECO 60min Fully complies to BS & EN standards Available with gravity and controlled descent INSTALLATION All NECO Fire Gard fire curtains are made to order. Installation and training is available for all our fire safety products. Please contact us for more information or to receive a quote. COMPLIANCE All NECO Fire Gard fire curtains comply to the following standards: BS 476 Part 22 EN 12101-1:2006 EN 12101-1: 2005 & A1: 2006 BS 8434-2 BSEN 949: 2000 BSEN 1636-1: 1999 BSEN 1363-1: 2000 BSEN 1363-2: BSEN 1634-1: 2000 BS 8434-2 EN 13501-2: 2007 & A1: 2009 BSEN 1634-3: 2004

NECO ELECTRICAL UK COMPANY LIMITED For information, to get a quote please contact a member of our Sales Team via email: info@necogroup.eu or on +44 2920 668332 WWW.NECOFIREGARD.COM Unit 8, Curran Industrial Estate Curran Road, Cardiff, CF10 5DF Registered in the United Kingdom Reg No. 04586443 VAT Number: 992110822