High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Similar documents
V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems 12K - 18K - 24K

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

ART الرفاهية تكنولوچيا بلمسة فنية

High Wall Split Air Conditioners 53QHCT KHCT

Slim Line Ceiling Concealed Ducted Split Systems

Hi Wall Split Air Conditioners

Inverter Wall Mounted Series

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

SKM. Air Conditioners TROPICAL

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Operating Functions Temperature Parameters

Just feel well. 2017/2018 Air conditioning

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

American Brand with Global Reach. Model: SMLW-SAGL

Inverter console UFV system. Compact design and personalised air flow selection

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

C&H NORDIC Commercial 4 SERVICE MANUAL

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

RC-0219-A. Single-Split Non Inverter Series

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SERIES. Ductless Split Comfort Systems. Mark of Superior Quality ADVANCED TECHNOLOGY ENERGY SAVINGS ECO-FRIENDLY NEW RESIDENTIAL LINE

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Packaged Terminal Air Conditioner (PTAC)

Inverter Wall Mounted

Specifications, Performance & Submittal

Q Series. Inverter Split Systems

PLXSID1605. Warning HEAD OFFICE :

2015 Split Air Conditioner Line R410 50Hz Line. October 24, 2014

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

eco Touch Premium Toshiba Airconditioning March 2016 For more details, please contact our sales office:

Packaged Terminal Air Conditioner (PTAC)

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

DESIGN & TECHNICAL MANUAL

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Wall Mounted Split Systems

HI-WALL SPLIT SYSTEMS

Residential and Light Commercial Ductless Systems Catalog

Ceiling Mounted Cassette Unit

Packaged Terminal Air Conditioner (PTAC)

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

Model: Ceiling Cassette V 9k-24k

we care about Better Air

Single - Zone Systems

Mobile Type Air Conditioner

Packaged Terminal Air Conditioner (PTAC)

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Compact design & easy maintenance

Concealed Ducted Split Series R-407C MBH

Now with WiFi as standard Find out more at

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

K sin. Mini Split Air Conditioners and Heat Pump

Submittal Data Sheet

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

G Series Inverter Split Systems

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Samsung AR5000 Air Conditioners. The Triangle. Samsung s Ultimate Cooling Design.

AIR CONDITIONING REVERSE-CYCLE INVERTER

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

PTAC 2017 Air Conditioner Collection

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

SRK20ZFX-S, 25ZFX-S, 35ZFX-S, 50ZFX-S

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Transcription:

HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy Fast Service & Maintenance Fans Smart Airflow Independent Dehumidification Fashion Design Coils Vertical Air flow Auto Swing Turbo Self diagnostic function LCD Display Inner Groove Copper Tubing Horizontal Air flow Auto Swing Follow Me Refrigerant Leak Detection Operation Hydrophilic Aluminum Fins Louver Position Memory ECO Compressor Super Quiet AMS Self Clean R410A HFC Refrigerant Anti-dust Filters AMS Minutes Min. Time Delay Washable Air Filters

High Wall Split Systems HFC410 A KHA-N COOL ONLY High Wall Split is the optimum air conditioning solution for places which require high wall installation, elegant appearance and ultimate comfort combined with efficient, quiet operation, optimum air distribution, and efficient Indoor Air Quality (IAQ). KEY FEATURES Healthy & Clean Indoor Air Quality (IAQ) anti dust washable air filters for clean and healthy air. IAQ SMART CONTROL Self Clean function to clean and dry the indoor coil of indoor unit to prevent the bleeding of odors and bacteria. Modern Aesthetic Design Attractive appearance with compact dimensions and light weight. Fits any interior decor with space saving. Infrared remote EFFICIENT & QUIET $ EFFICIENT AIR FILTRATION Anti-dust Air Filters OUTDOOR UNIT Smart LCD display shows control functions and error code in case of a malfunction. Tropical Operation with Minimum Electrical Consumption Works with the new R-410A refrigerant which increases its energy efficiency and does not degrade the ozone layer. Patented heat transfer and aerodynamics technologies to ensure prefect operation for energy saving and low operating cost. Patented heat transfer and aerodynamics technologies to ensure prefect operation outdoor ambient temperature for energy saving and low operating cost. Air Management System (AMS) leading to maximum air flow with minimum turbulence for minimum air resistance, smooth airflow and efficient operation. Carrier innovative uneven aerofoil tangential blower technology for efficient operation at all speeds with maximum air flow. indoor and outdoor coils with large heat transfer surfaces for minimum electrical consumption. R-410A HFC $ AMS www.carrierafrica.com trapeziform Inner groove copper tubing compared with traditional copper tubing, it allow more refrigerant flow, improving heat exchange efficiency and lowering power consumption while keeping the same capacity output level. Precoated Hydrophilic Aluminum Fins of indoor coil to protect the coil against corrosion and to allow easy and quick removal of unrestricted condensate water between the fins to increase airflow, improve efficiency of heat exchange and accelerate cooling process.

Key Features Quiet with Minimum Sound Level Durability Patented cross flow fan, elephant ear propeller, new heat exchangers, improved Air Management System (AMS), and quiet compressor. Anti-rust, weather proof and long life outdoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Complete Control s for Comfort Powder painted casing of outdoor unit with prefect adhesion of highly resistant ployester paint 60-80 micros thick, which is electro-statically applied and baked at a temperature of 0 C. Smart LCD infrared wireless remote control with complete control and safety functions built in the control system to ensure efficiency and safety at all operating conditions. Smart supply air flow for comfort cool or heat as per the selected mode for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Auto-swing horizontal supply air flap to up and down for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Complete Safety & Reliability s Auto restart function with backup memory. When the power failure is happened during the air conditioner operation, the microprocessor of printed circuit board will memorize the operation setting. After the power is recovered, the air conditioner operates automatically ( without remote control after elapse of compressor time delay ), according to the previous operation settings. Manual direction of vertical supply air flaps to right and left for optimal air distribution of supply air temperature and velocity inside air conditioned space. (three) minutes safety time delay between compressor turning off and turning on for compressor protection against cycling. Min. Louver Position Memory When you start the unit next time, the angle of horizontal louver will automatically move to the same position as you set last time. Auto fan speed which changes the fan speed automatically to high or medium or low fan speed by sensing the temperature difference between room temperature and set temperature. Auto Anti-freezing protection of indoor coil when the system is operating in cool mode with excessive dirt on the indoor coil and / or clogged air filters and / or when the air conditioner is operating in cool mode at low ambient temperature. Smart self-diagnostic function for malfunctions detection for easy fast service and maintenance. Anti Freezing Auto mode which changes the operation mode and capacity output automatically according to temperature difference between room temperature and set temperature. Independent Dehumidification mode which dehumidifies the room efficiently, but not lower the temperature so obviously as cooling operation. Smart Refrigerant leak detection by sensitive sensors mounted on the indoor and outdoor coils for easy fast service and maintenance. The components of both indoor and outdoor units comply with international standards of performance and safety. Turbo function to maximize the output of cooling capacity, make the room cool down rapidly and attain the desired temperature in the shortest time. Follow Me function for smart control of comfortable temperature when you stay close to the remote control. With this technology, an efficient temperature sensor is built in the remote control just like the air conditioner is following you. ECO function for energy saving and comfortable healthy sleep which automatically changes fan speed to low speed and controls both set and room temperatures. Programmable timer for easy on and off selection with energy savings including off timer, on timer, off/on timer and on/off timer functions. Easy Installation, Service & Maintenance Flexible multi outlet locations for piping from the indoor unit, easy piping connections and easy electrical connections between outdoor and indoor units. Easy accessibility to all key components. common spare parts across product family. Easy removal of front panel for cleaning by easy disassembly of panel engagement with indoor unit cabinet. Easy removal of washable air filters for cleaning by opening the hinged front panel up and then pulling filters down outside the indoor unit. Rev. (0) - 017

High Wall Split Systems Key Features Self Clean Self Clean function which is used after automatically cooling mode to clean and dry the indoor coil of indoor unit to prevent the bleeding of odors and bacteria. When Self Clean function is activated, firstly, the indoor unit operates as fan - only mode with low fan speed initially. Then during this period the condensed water will take away some dust on the fins of indoor coil. The whole process cleans the internal side of indoor unit and prevents the aspiration of bacteria. Then Self Clean function will stop and then the air conditioner will stop operation. Follow Me Fan Only Mode Operation Carrier Follow Me technology makes your air conditioner follow you for smart comfortable temperature. When Follow Me function is activated, the room temperature sensor built into the remote control is activated and replaces the room temperate sensor installed inside the indoor unit. Then the air conditioner regulates the room temperature based on the temperature around the remote control which is close to you. Ordinary temperature sensor location Follow Me temperature sensor is built-in to the remote control Smart Air flow Normal Operation Operation with Follow Me Smart supply air flow for comfort cool mode for optimal air distribution of supply air temperature and velocity inside the air conditioned space. During cool mode, the supply air flap is opened counter-clockwise, which leads the supply air to blow out horizontally and then fall down by its gravitation. This results in effectively reducing the temperature difference between top and bottom air space and achieve uniform temperature inside the room in the fastest way. www.carrierafrica.com 4 Cool Mode

Key Features Turbo Turbo function is used when you first come home or when you have unexpected guests. When Turbo function is activated, the air conditioner operates in its maximum speed for 0 minutes to maximize the output of cooling capacity. Carrier Turbo cooling technology makes your room cool down rapidly, and attain the desired temperature in the shortest time. ECO Sleep - ECO ( Sleep ) function is useful when you go to sleep. This function is useful for energy saving, quiet and comfortable healthy sleep. - When ECO ( Sleep ) function is activated the air conditioner changes automatically the setting temperature which in turn, changes automatically the room temperature to maintain the most comfortable temperature and to avoid overcooling during cool mode. Rev. (0) - 017

High Wall Split Systems Wireless Remote Control Display Of Remote Control 1 1 6 7 11 1 4 8 9 10 14 1 AUTO COOL DRY HEAT 1 AUTO COOL DRY HEAT SET TEMP. TIMER ON OFF 4 6 7 8 FAN HIGH MED LOW Signal transmission indicator MODE indicator Automatic Cooling Dehumidification only Heating FAN Ventilation (fan only) ON / OFF indicator 4 SET TEMP. indicator Control Buttons 1 MODE selection button AUTO - COOL - DRY - FAN LOW MED FAN SPEED indicator FAN SPEED indicator LOW FAN SPEED indicator MED Decrease temperature button The set temperature is decreased down to 17 C. HIGH AUTO FAN SPEED indicator HIGH FAN SPEED indicator AUTO 4 Increase temperature button The set temperature is increased up to 0 C. FAN selection button Low - Medium - High - Auto fan speed 6 7 8 TIMER ON function indicator TIMER OFF function indicator FOLLOW ME function indicator ON/OFF button Display Of Indoor Unit 6 Air Direction function button 7 Vertical Air Flow Auto Swing 8 Sleep function button 9 TIMER ON function button www.carrierafrica.com 10 11 1 1 14 TIMER OFF function button My Mode function button to memorize the preferred settings Follow Me function button LED Display function button TURBO function button SET TEMP. indicator / Error code in indicator OPERATION led TIMER function led Cold Draft or Defrost led 6

Smart Self Diagnostic For Malfunction Detection The electronic printed circuit board in the indoor unit is equipped with smart self diagnostic function which automatically stops the operation of the air conditioner in case of a malfunction. Leds status refers to malfunction reason Operation lamp Timer lamp Display LED STATUS 1 time X E0 EEPROM parameter error times X E1 Indoor / outdoor units communication error(only for MSAFD-4CRN1-QB6W, MSAFD-1CRN1-QB6W) times X E Zero-crossing signal detection error 4 times X E Indoor fan speed has been out of control times X E4 6 times X E 9 times X E7 7 times X EC X : off Indoor room temperature sensor T1 open circuit or short circuit Evaporator coil temperature sensor T open circuit or short circuit Indoor PCB / Display board communication error Refrigerant leak or any malfunction lead to stopping of compressor operation : flash Rev. (0) - 017 7

High Wall Split Systems Technical Specifications System type Cool Only Cool Only Cool Only Cool Only Indoor unit model 4KHA009N 4KHA01N 4KHA018N 4KHA04N Outdoor unit model 8KHA009N 8KHA01N 8KHA018N 8KHA04N Cooling capacity kw.64..8 7.0 Btu/hr 9000 1000 18000 4000 Rated input - Cooling W 941 16 09 70 Rated current - Cooling A 4..6 8.8 11.7 E.E.R. - Cooling W/W.80.80.60.60 Btu/wh 9.6 9. 8.87 8.87 Indoor unit model 4KHA009N 4KHA01N 4KHA018N 4KHA04N Dehumidification l/h 1.0 1. 1.8.6 Nominal air flow (low/med/high) m /hr 10 / 9 / 448 74 / 47 / 604 / 67 / 808 78 / -- / 1011 cfm 18 / 1 / 64 0 / 78 / 64 1 / 87 476 446 / -- / 89 Sound Pressure (low/med/high) db(a) 8. / 6. 7.8 / 40.0.9 / 7 / 4.8 9.8 / 47.9 Net Dimensions (W H D) mm 71x8x194 80x8x194 97x0 x1 1040 7 0 Net Packing (W H D) mm 780x60x70 870x60x70 10x80x9 110x10x40 Net Weight / Packing kg 7.4/9. 8/10. 10.4/1.9 1.8/17.8 Outdoor unit model 8KHA009N 8KHA01N 8KHA018N 8KHA04N Tropical Compressor type Rotary Rotary Rotary Rotary Refrigerant type / Coupler type R410A / Flare R410A / Flare R410A / Flare R410A / Flare Sound pressure db(a) 4.9 7.4 60.4 Net Dimensions (W H D) mm 700x0x7 770xx00 770xx00 84x70x6 Net Packing (W H D) mm 81x61x 900x8x4 900x8x4 96x7x9 Net Weight / Packing kg./7.6 9.1/1.4 4/6.9 46.8/0.1 Installation data Pipe connection sizes mm ( inch ) Gas Φ9. ( /8 ) Φ1.7 ( 1/ ) Φ1.7 ( 1/ ) Φ1.9 ( /8 ) Liquid Φ6. (1/4 ) Φ6. (1/4 ) Φ6. (1/4 ) Φ9. ( /8 ) Maximum pipe length m 0 0 Maximum height difference m 8 8 10 10 Condensate drain hose diameter inch /8 /8 /8 /8 Power supply V/ph/Hz 0-40/1/0 0-40/1/0 0-40/1/0 0-40/1/0 www.carrierafrica.com * Cooling Capacity, Dehumidification and Energy Efficiency Ratio (EER) are based on ISO 11 Standard at operating conditions : 7/19ºC db/wb Indoor Temperature. / 4 ºC db/wb Outdoor Temperature. High Air Flow 0 volts power supply. (For sizes 1-18-4-0) 80 volts power supply. (For sizes 6-48-60) * Systems work in cooling at ambient temperature up to 46ºC * Sound pressure is measured in anechoic chamber based on GB/T77 Standard * Carrier is committed to continuously improving its products according to national and international standards to ensure the highest quality and reliability standards, and to meet market regulations and requirements. All specifications subject to change without prior notice according to Carrier policy of continuous development. 8