Hi - Wall Split Systems 12K - 18K - 24K

Similar documents
Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Hi Wall Split Air Conditioners

Slim Line Ceiling Concealed Ducted Split Systems

High Wall Split Air Conditioners 53QHCT KHCT

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

ART الرفاهية تكنولوچيا بلمسة فنية

Inverter Wall Mounted Series

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

SKM. Air Conditioners TROPICAL

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

CARRIER XPower Inverter

Inverter console UFV system. Compact design and personalised air flow selection

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

C&H NORDIC Commercial 4 SERVICE MANUAL

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

we care about Better Air

Ductless Split Air Conditioner

Now with WiFi as standard Find out more at

Operating Functions Temperature Parameters

2015 Split Air Conditioner Line R410 50Hz Line. October 24, 2014

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

PLXSID1605. Warning HEAD OFFICE :

American Brand with Global Reach. Model: SMLW-SAGL

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Ductless Split Air Conditioner

RC-0219-A. Single-Split Non Inverter Series

DESIGN & TECHNICAL MANUAL

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT

G Series Inverter Split Systems

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

eco Touch Premium Toshiba Airconditioning March 2016 For more details, please contact our sales office:

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

2 &3-4 Head Multi System

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Air Conditioner CONTENTS

K sin. Mini Split Air Conditioners and Heat Pump

Just feel well. 2017/2018 Air conditioning

Split Air Conditioners

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Lennox Mini-Split Systems Year-Round Comfort and Performance

Concealed Ducted Split Series R-407C MBH

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Wall Mounted Split Systems

Inventor of the Inverter Digital Inverter System

Wired Controller XK60

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Residential Air Conditioners 2013 CATALOGUE / B

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

HI-WALL SPLIT SYSTEMS

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Floor-Standing Type(E Series)

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Pure Efficiency Meets Healthy Living NEW 2013

Minisplit Inverter Systems

Air Conditioners. Summer

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Cozy Hi Wall Inverter Air Conditioner

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Amena s Globo series are a group of air conditioning products designed for markets where maximum

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

JUNE & 3-4 Head Multi System

Q Series. Inverter Split Systems

OWNER S MANUAL VMH 09/12/18/24

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

SERIES. Ductless Split Comfort Systems. Mark of Superior Quality ADVANCED TECHNOLOGY ENERGY SAVINGS ECO-FRIENDLY NEW RESIDENTIAL LINE

53 KNL / 53 QNL OWNER S MANUAL

AIR CONDITIONING REVERSE-CYCLE INVERTER

Transcription:

R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic Filter AMS Efficient AMS Wireless Control Auto Mode Min. Minutes Time Delay Refrigerant Leak Detection IAQ Efficient Anti-dust Filters Efficient Fans Smart Airflow Independent Dehumidification Anti Freezing Anti-Freezing Protection Easy Flexible Installation Fashion Design Efficient Coils Vertical Air Flow Auto Swing Turbo Function High Temp. Protect High Temp. Protection Easy Fast Maintenance LCD Display Inner Groove Copper Tubing Horizontal Air Flow Manual Direction ECO ECO Function Cold Draft Protection Cleanable Panel $ Efficient Operation Hydrophilic Aluminum Fins Temperature Compensation Timer Functions Defrost Protection Washable Air Filter

Hi - Wall Split Systems R22 Cool Only & Heat pump High Wall Split is the optimum air conditioning solution for the places which require high wall installations, elegant appearance and ultimate comfort combined with efficient, quiet operation, optimum air distribution and efficient Indoor Air Quality (IAQ). SMART CONTROL KEY FEATURES Healthy & Clean Indoor Air Quality (IAQ) generates large quantity of negative ions for refreshing air, killing germs, removing smoke and dust particles. gives an immediate sensation of energy and well-being. Efficient carbon - electrostatic air filter for odors and microscopic dust removal. Infrared wireless remote OUTDOOR UNIT 12K 18K 24K EFFICIENT, TROPICAL & QUIET $ EFFICIENT AIR FILTRATION Efficient anti dust washable air filters for clean and healthy air. Modern Aesthetic Design Compact indoor unit with attractive appearance fits any interior decor with space saving. New stylish outdoor unit look. Smart LCD display shows control functions and error code in case of a malfunction. Efficient Tropical Operation with Minimum Electrical Consumption Patented heat transfer and aerodynamics technologies to ensure prefect operation up to 52 C outdoor ambient temperature for energy saving and low operating cost. Efficient tropical rotary compressor works in high ambient up to 52 C with high efficiency and low electrical consumption leading to true powerful system cooling. Efficient Air Management System (AMS) leading to maximum air flow with minimum turbulence for minimum air resistance, smooth airflow and efficient operation. Carrier innovative uneven aerofoil tangential blower technology for efficient operation at all speeds with maximum air flow. Efficient indoor and outdoor coils with large heat transfer surfaces for minimum electrical consumption. IAQ $ AMS www.miraco.com.eg 2 Anti-dust Air Filters Quality Management System ISO 9001 : 2008 Certificate No.: QS-5519HH Carbon- Electrostatic Air Filter Enviromental Management System ISO 14001 : 2004 Certificate No : 12 104 04 TMS Safety Management System BS OHSAS 18001 : 2007 Certificate No : 12 116 04 TMS Efficient trapeziform Inner groove copper tubing compared with traditional copper tubing, it allow more refrigerant flow, improving heat exchange efficiency and lowering power consumption while keeping the same capacity output level. Precoated Hydrophilic Aluminum Fins of indoor coil to protect the coil against corrosion and to allow easy and quick removal of unrestricted condensate water between the fins to increase airflow, improve efficiency of heat exchange and accelerate cooling.

Key Features Comfort & Quiet with Minimum Sound Level Patented cross flow fan, elephant ear propeller, new heat exchangers, improved Air Management System (AMS), and quiet compressor. Smart LCD infrared wireless remote control with complete control and safety functions built in the control system to ensure efficiency and safety at all operating conditions. Smart supply air flow for comfort cool or heat as per the selected mode for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Auto-swing horizontal supply air flap to up and down for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Manual direction of vertical supply air flaps to right and left for optimal air distribution of supply air temperature and velocity inside air conditioned space. Temperature Compensation based on different installation height of indoor unit, the temperature deviation of the sensor sensed against the actual floor temperature always is different. Changing the jumping wires combination on the indoor PCB is possible to compensate the deviation. This could be achieved by installer in the installation field. Auto fan speed which changes the fan speed automatically to high or medium or low fan speed by sensing the temperature difference between room temperature and set temperature. Auto mode which changes the operation mode and capacity output automatically according to temperature difference between room temperature and set temperature. Independent Dehumidification mode which dehumidifies the room efficiently, but not lower the temperature so obviously as cooling operation. Turbo function to maximize the output of cooling capacity, make the room cool down rapidly and attain the desired temperature in the shortest time. ECO function for energy saving and comfortable healthy sleep which automatically changes fan speed to low speed and controls both set and room temperatures. Programmable timer for easy on and off selection with energy savings including off timer, on timer, off/on timer and on/off timer functions. Auto ECO Safety & Reliability Auto restart function with backup memory. When the power failure is happened during the air conditioner operation, the microprocessor of printed circuit board will memorize the operation setting. After the power is recovered, the air conditioner operates automatically ( without remote control after elapse of compressor time delay ), according to the previous operation settings. (three) minutes safety time delay between compressor turning off and turning on for compressor protection against cycling. Anti-freezing protection of indoor coil when the system is operating in cool mode with excessive dirt on the indoor coil and / or clogged air filters and / or when the air conditioner is operating in cool mode at low ambient temperature. High temperature protection of outdoor coil when the air conditioner is operating in cool mode. This protection is only for heat pump system. Cold draft protection when the system is operating in heat mode to prevent cold air blowing out at the beginning of heat mode which avoids the discomfort to the user. High temperature protection of indoor coil when the air conditioner is operating in heat mode. Defrost protection of outdoor coil when the air conditioner is operating in heat mode at very low ambient temperature. Smart self-diagnostic function for malfunctions detection for easy fast service and maintenance. Smart Refrigerant leak detection by sensitive sensors mounted on the indoor and outdoor coils for easy fast service and maintenance. The components of both indoor and outdoor units comply with international standards of performance and safety. Easy Installation, Service & Maintenance Flexible multi outlet locations for piping from the indoor unit, easy piping connections and easy electrical connections between outdoor and indoor units. Min. Anti Freezing Hi Temp. Protect Cool Hi Temp. Protect Heat Durability Anti-rust, weather proof and long life outdoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Powder painted casing of outdoor unit with prefect adhesion of highly resistant ployester paint 60-80 micros thick, which is electro-statically applied and baked at a temperature of 220 C. Easy accessibility to all key components. common spare parts across product family. Easy removal of front panel for cleaning by easy disassembly of panel engagement with indoor unit cabinet. Easy removal of washable air filters for cleaning by opening the hinged front panel up and then pulling filters down outside the indoor unit. Rev. (0) - 2012

Hi - Wall Split Systems Cool Mode Heat Mode Key Features Technology generates large quantity of negative ions for refreshing air, killing germs, removing smoke and dust particles. gives an immediate sensation of energy and well-being. has the following advantages : Eliminates bacteria and dust mites. Remove bad odors, smoke and domestic smells. Eliminates potentially pollutants and chemicals. Alleviates fatigue, allergies, body paints and disease. Increase feeling of calmness, reducing irritability and depression. Improves energy and alertness. Smart Air flow Smart supply air flow for comfort cool and heat as per selected mode for optimal air distribution of supply air temperature and velocity inside the air conditioned space. During cool mode, the supply air flap is opened counter-clockwise, which leads the supply air to blow out horizontally and then fall down by its gravitation. This results in effectively reducing the temperature difference between top and bottom air space and achieve uniform temperature inside the room in the fastest way. During heat mode, the supply air flap is opened clockwise, which leads the warm air to fall directly on the floor vertically. Since hot air is lighter than cold air around, it will diffuses upward quickly. This results in effectively reducing the temperature difference between top and air space. Temperature Compensation Based on different installation height of indoor unit, the temperature deviation of the sensor sensed against the actual floor temperature always is different. Smart control of indoor unit can compensate the deviation. www.miraco.com.eg -2 C +2 C Cool Mode Usually during cool mode, the ceiling temperature ( which the indoor room sensor detects ) is lower than the floor temperature ( which the body feels ) by about 2 C. Temperature compensation function adjusts the set to floor temperature thereby offering better comfort level in the cooling mode. Usually during heat mode, the ceiling temperature ( which the indoor room sensor detects ) is higher than the floor temperature ( which the body feels ) by about 2 C. Temperature compensation function adjusts the set saving in the heating mode. 4 Heat Mode

Key Features Turbo Function Turbo function is used when you fist come home or when you have unexpected guests. When Turbo function is activated, the air conditioner operates in its maximum speed for 20 minutes to maximize the output of cooling capacity. Carrier Turbo cooling technology makes your room cool down rapidly, and attain the desired temperature in the shortest time. ECO ECO ( SLEEP ) Function - ECO ( Sleep ) function is useful when you go to sleep. This function is useful for energy saving, quiet and comfortable healthy sleep. - When ECO ( Sleep ) function is activated the air conditioner changes the set temperature automatically which in turn changes the room temperature automatically to maintain the most comfortable temperature and to avoid overcooling during cool mode or overheating during heat mode. Rev. (0) - 2012 5

Hi - Wall Split Systems Wireless Remote Control Display Of Remote Control 2 1 54 8 6 7 11 14 15 2 10 12 1 9 1 5 4 9 1 2 COOL DRY COOL SET TEMP. o DRY HEAT ON OFF FAN CLOCK SPEED LOW MED HIGH 8 Signal transmission indicator MODE indicator Automatic (heat pump model only) Cooling and dehumidification Dehumidification only 6 7 10 HEAT Heating FAN Ventilation (fan only) ON / OFF indicator Control Buttons 1 MODE selection button 4 5 6 SET TEMP. indicator Temperature unit of measurement (ºC or ºF) CLOCK indicator 2 Decrease temperature button 7 ON or OFF function indicator Increase temperature button 8 FAN SPEED indicator 4 5 6 7 FAN SPEED selection button ON/OFF button AIR DIRECTION function button SWING function button LOW MED HIGH 9 FAN SPEED indicator FAN SPEED indicator LOW FAN SPEED indicator MED FAN SPEED indicator HIGH ECO function indicator 8 ECO function button 10 LOCK function indicator 9 TURBO function button 10 CLOCK function button www.miraco.com.eg 6 11 12 1 14 15 LED DISPLAY function button ON or OFF function button CANCEL function button RESET function button F/C ( Fahrenheit or Celsius ) setting function button

Display Of Indoor Unit Cool Only DEFROST mode led Cold Draft or Defrost led Remote control signal receiver SET TEMP. led led function led DEFROST Heat Pump mode led Remote control signal receiver SET TEMP. led led function led Rev. (0) - 2012 7

Hi - Wall Split Systems Smart Self Diagnostic Function For Malfunction Detection The electronic printed circuit board in the indoor unit is equipped with smart self diagnostic function which automatically stops the operation of the air conditioner in case of a malfunction. Cool Only Systems Hi Wall Split Systems 5KHET12-708F 5KHET18-708F Hi Wall Split System 5KHET24-708F Malfunction Reason Malfunction Reason Return Air Sensor ( open circuit or short circuit ) Return Air Sensor (open or short circuit) Indoor Coil Sensor ( open circuit or short circuit ) Indoor Coil Sensor (open or short circuit) Indoor Fan Motor has been out of control for over 1 minute Compressor Overload cuts out 4 times Electronic Control PCB- ( EEPROM error ) Outdoor Coil Sensor (open or short circuit) Compressor Overload cuts out 4 times Electronic Control PCB- ( EEPROM error ) Indoor / Outdoor Units communication error No over zero signal Outdoor unit protection works Refrigerant leak Refrigerant leak www.miraco.com.eg s status refers to malfunction reason = OFF = ON = Flash at 5Hz = Flash continuously s status refers to malfunction reason = OFF = ON = Flash at 5Hz = Flash continuously

Smart Self Diagnostic Function For Malfunction Detection The electronic printed circuit board in the indoor unit is equipped with smart self diagnostic function which automatically stops the operation of the air conditioner in case of a malfunction. Heat Pump Systems DEFROST Hi Wall Split Systems 5QHET12-708F 5QHET18-708F Hi Wall Split System 5QHET24-708F Malfunction Reason Malfunction Reason DEFROST Auto Return Air Sensor ( open circuit or short circuit ) Indoor Coil Sensor ( open circuit or short circuit ) Indoor Fan Motor has been out of control for over 1 minute Compressor Overload cuts out 4 times Electronic Control PCB- ( EEPROM error ) No over zero signal Refrigerant leak s status refers to malfunction reason = OFF = ON = Flash at 5Hz = Flash continuously Return Air Sensor (open circuit or short circuit) Indoor Coil Sensor (open circuit or short circuit) Outdoor Coil Sensor (open circuit or short circuit) Compressor Overload cuts out 4 times Electronic Control PCB- ( EEPROM error ) Indoor / Outdoor Units communication error Outdoor unit protection works Refrigerant leak s status refers to malfunction reason = OFF = ON = Flash at 5Hz = Flash continuously Rev. (0) - 2012

Hi - Wall Split Systems Technical Specifications www.miraco.com.eg 8 System model Cool Only 5KHET12-708F 5KHET18-708F 5KHET24-708F Indoor unit model Cool Only 42KHET12-708F 42KHET18-708F 42KHET24-708F Outdoor unit model Cool Only 8KHET12-708 8KHET18-708 8KHET24-708 Cooling capacity Btu/hr 12000 17500 2500 kw.52 5.1 6.89 Rated input - Cooling W 1250 1882 2554 Rated current - Cooling A 5.7 8.9 12.1 E.E.R. - Cooling Btu/wh 9.60 9.0 9.20 W/W 2.82 2.7 2.70 System model Heat Pump 5QHET12-708F 5QHET18-708F 5QHET24-708F Indoor unit model Heat Pump 42QHET12-708F 42QHET18-708F 42QHET24-708F Outdoor unit model Heat Pump 8QHET12-708 8QHET18-708 8QHET24-708 Cooling capacity Btu/hr 11500 17000 2000 kw.7 4.98 6.74 Rated input - Cooling W 126 1848 2556 Rated current - Cooling A 5.6 8.9 12.0 E.E.R. - Cooling Heating capacity Btu/wh 9.0 9.20 9 W/W 2.7 2.69 2.64 Btu/hr 12000 17000 2500 kw.52 4.98 6.89 Rated input - Heating W 1065 1655 25 Rated current - Heating A 4.9 7.7 11.2 C.O.P - Heating W/W.0.01 2.95 Indoor unit model Dehumidification l/h 1.2 1.8 2.6 Nominal air flow (low/med/high) cfm 26 / 277 / 24 0 / 442 /501 478 / 51 / 608 m /hr 400 / 470 / 550 560 / 750 / 850 810 / 870 / 100 Sound Pressure (low/med/high) db(a) 5 / 8 / 41 1 / 40 / 4 9 / 41 / 47 Net Dimensions (W H D) mm 790 x 265 x 195 920 x 292 x 225 1080 x 0 x 228 Net Weight Cool Only / Heat Pump kg 9 12 17 Outdoor unit model Tropical Compressor type Rotary Rotary Rotary Refrigerant type / Coupler type R22 / Flare R22 / Flare R22 / Flare Sound pressure db(a) 56 57 62 Net Dimensions (W H D) mm 780 540 250 760 x 590 x 285 860 x 575 x 50 Net Weight Cool Only / Heat Pump kg / 4 42 / 4 58.7 / 58.7 Pipe connection sizes ( inch ) LiquidxGas 1/4 x /8 1/4 x 1/2 /8 x 5/8 Maximum pipe length m 8 20 20 Maximum height difference m 4 10 10 Condensate drain hose diameter inch 5/8 5/8 5/8 Recommended Wire Size / No. of Wires from Power Supply to Indoor Unit mm 2 ( Qty) mm 2 (2 Wires+1 Earth) 4 mm 2 (2 Wires+1 Earth) - Recommended Wire Size / No. of Wires from Power Supply to Outdoor Unit Recommended Wire Size / No. of Wires between Outdoor Unit (HP) and Indoor Unit (HP) Recommended Wire Size / No. of Wires between Outdoor Unit (CO) and Indoor Unit (CO) mm 2 ( Qty) - - 4 mm 2 (2 Wires+1 Earth) mm 2 ( Qty) mm 2 (2 Wires+1 Earth) + mm 2 ( 2 Wires ) 4 mm 2 (2 Wires+1 Earth) + mm 2 ( 2 Wires ) 1 mm 2 (4 Wires+1 Earth) mm 2 ( Qty) mm 2 (2 Wires+1 Earth) 4 mm 2 (2 Wires+1 Earth) 1 mm 2 (2 Wires+1 Earth) Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 * Cooling Capacity and Energy Efficiency Ratio (EER) based on ASHARE Standards @ 5ºC ambient at operating conditions : 26.7/19.4ºC db/wb Indoor Temperature. 20 volts power supply. High Air Flow * Systems work in cooling at high ambient temperature up to 52ºC * Cooling Capacity & EER tolerance 5% * Heating Capacity and Coefficient of Performance (COP) are based on ASHARE Standards at operating conditions : 20ºC db Indoor Temperature. 7/6ºC db/wb Outdoor Temperature. 20 volts power supply. High Air Flow * Systems comply with Safety Standards IEC 605-2-40 * Carrier is committed to continuously improving its products according to national and international standards to ensure the highest quality and reliability standards, and to meet market regulations and requirements. All specifications subject to change without prior notice according to Carrier policy of continuous development.