ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

PG 990 Atomic Absorption

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

SP-3800AA Atomic Absorption Spectrophotometer

AAnalyst 700 Atomic Absorption Spectrometer

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Atomic Absorption Spectrometer

ice 3000 Series Atomic Absorption Spectrometers

t. +44 (0) f. +44 (0) e. w.

AAnalyst 600/800 atomic absorption spectrometers

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Specifications Wavelength Range: 190 nm to 800 nm continuous

Mercury Vapor Monitor VM-3000

detectors UltiMate 3000 Variable Wavelength Detectors

VM-3000 Mercury Vapor Monitor

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

CS744 Series: Carbon/Sulfur by Combustion

VM-3000 Mercury Vapor Monitor

Technical specifications of FT-IR Spectrometer

Variable Temperature Options for Optical Experiments

PSA Series. Particle Size Analyzer

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Model S FT-IR SPECTROMETER

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

The New Digital BWB Flame Photometer Range

C122-E058C. AA-7000 Series. Shimadzu Atomic Absorption Spectrophotometers

Common Features of DX-600 Modules

M&S Series Atomic Absorption Systems

Atomic Absorption Spectrophotometers. AA Series C122-E058E

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

NanoReady. Micro UV-Vis Spectrophotometer

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Lighting Measurement Solutions

An FT-NIR Primer. NR800-A-006

portable gas analyser

RAMAN SPECTROSCOPY See more, faster than ever before

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

Nexera-i Specifications Prominence-i Specifications

Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

HFID Heated Total Hydrocarbon Analyzer Module

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Who is GBC Scientific Equipment?

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

1,000W (DAP-60K: 100 W per digestion vessel)

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

HYDROCARBONENGINEERING June June 2015

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

Agilent 1290 Infinity II Vialsampler Data Sheet

Nicolet Evolution 300. UV-Visible Spectrophotometer

WASTEWATER Online UV%Transmission Analyzer

The New Digital BWB Flame Photometer Range

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Measuring Stokes shift. Easy, fast and reliable

Series 9000 Total Hydrocarbon Analyzer

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

WHAT IS LASER ULTRASONIC TESTING?

Variable Temperature Microprobe Systems

DP 300 mobile dew point instrument

portable gas analyser

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Power Flame Incorporated

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Customised HPLC Systems for Highest Performance

JUPITER SERIES. High Throughput Closed Microwave Digestion/Extraction Workstation

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

BlueSpin Magnetic Hotplate Stirrer

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

TC-PLUS Thermal Cyclers

HPLC Column Ovens and Temperature Controllers

A Platform for the Future ULTIMA 2 ICP OPTICAL E MISSION S PECTROMETER

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Introduction to the Fusion TOC Analyzer

OPEN PATH DETECTION OF ACROLEIN LEAKS

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Chemistry Instrumental Analysis Lecture 4. Chem 4631

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Updated Leak Detection & Location Technology

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

RIELLO 40 GS/M SERIES

USER MANUAL MINITRACER PORTABLE SNIFFER

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

Automatic Isokinetic Sampler ST5

Chapter 1. Introduction

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

Start Saving with VWR Laboratory Benchtop Equipment!

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Transcription:

A3

A3 Affordable Lab Technology

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including: Agricultural Environmental Metal Geological Pharmaceutical Clinical Food Mining Petrochemical The versatile instrument is available in three configurations: A3F - The instrument is equipped with a flame atomiser only. The positioning of which is fully controlled by the embedded computer system and AA-Win Pro software. Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N20/Acetylene and the Air/LPG (Natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. A3G -The instrument is equipped with a Graphite Furnace Atomiser only. The graphite head is fixed into the optical path to maximise performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. A3FG -The instrument is equipped with both Flame Atomiser and Graphite Atomiser as described above. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA- Win Pro software.

FEATURES & FUNCTIONS PC System is used to control the instrument. Preinstalled AA-Win Pro software, user manuals, cook book and Windows 7 professional operating system. AA-Win Pro software provides full control of the instrument and autosampler with easy method change for each technique. Automatic 8 Hollow Cathode lamp turret controlled and optimised by the AA-Win Pro software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming. D2 lamp background correction system fitted as standard to all configurations. High energy D2 lamp and adjustable beam splitter mirror are optimised by the AA-Win pro software. Self Reversal background correction system fitted as standard to all configurations. The high performance background system uses the same hollow cathode lamp as installed for the analysis. Minimum extra components are required and optical alignment is very simple. Self Reversal can be used for any element at any wavelength making it extremely versatile. High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner monochromator. A universal autosampler is available as an optional accessory which is conveniently mounted on the front of the A3 instrument. Absorption and Emission modes are standard features in the AA-WinPro software as well as peak height, peak area, sequential and manual integration modes. Air/Acetylene The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration. The high sensitivity (Cu 2ppm >0.280abs) is due to the efficiency of the fixed position glass nebuliser fitted as standard. An acid resistant replacement is available as an option. The flame can be easily set from blue lean flame through stoichiometric to fuel rich by means of computer control. N20/Acetylene The N20/Acetylene flame uses a 50mm single slot burner and is available as an optional extra. This flame configuration is used to measure elements less prone to ionization such as: Aluminium, Tin, Titanium, Calcium, Vanadium and Molybdenum. Switching from Air/Acetylene to N20/Acetylene to Flame Off is fully controlled by the AAWinPro software. Air/Propane(LPG) This flame uses a 3 slot burner and with the Iow pressure requirement it is also much safer to operate. Due to the Iow temperature of the flame it is ideal for analysing alkali metals such as: Potassium, Sodium and Lithium, especially when used in the emission mode. Some remote areas of the world have difficulty obtaining Acetylene gas of a high enough purity to operate the flame correctly, LPG can give a real alternative and offer comparable results for most elements throughout the wavelength range. FLAME ATOMISER FEATURES The flame atomiser offers three flame options: Air/acetylene is the standard configuration with the N20/ acetylene and Air/LPG as options.

3. 4

SAFETY FEATURES Pressure monitoring for all gases Burner Identification Flame sensor Drain Trap level Sensor Gas Leak Detector Over Pressurein Premix Safety Cut off Switch GRAPHITE ATOMISER FEATURES The integrated Graphite Furnace Atomiser is available in two instrument configurations. In the A3G instrument the graphite furnace head is fixed into the light path so alignment with the optical path is simple and accurate. In the A3FG instrument the graphite furnace head is fixed behind the flame atomiser assembly and is motorised into position by a simple operation in the AA-WinPro software. The positions for the flame and graphite are saved making it easy to swap between modes for different analysis. SAFETY FEATURES Argon Gas pressure Sensor Water flow sensor Over Temperature Sensor Broken graphite tube protection FEATURES & FUNCTIONS The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system and has been designed to reduce analytical problems normally associated with this type of technique. Pyrolytically coated graphite tubes are used as standard and are manufactured to improve performance as well as increase the analytical life. Platform graphite tubes are supplied as standard and will accept volumes up to 20ul. Non-platform graphite tubes are also available as an optional extra. Up to 10 heat stages are available for the programming of the graphite atomiser. These can be set and stored within the AA-WinPro software. The graphite tube is held in position by means of a gas piston. Replacement of the graphite tube is performed by a simple command in the AA-Win Software. The graphite tube is efficiently cooled by an additional water circulation system (supplied separately).

Spectrometer System Wavelength range Light Source Modulation Modulation frequency Monochromator Grating Blazed Wavelength Focus Bandwidth Scan mode Photometric Type Wavelength Accuracy Wavelength Resolution Wavelength Reproducibility Baseline Stability Background Correction Flame Analysis 185nm -910nm Hollow cathode lamp (HCL), Deuterium Arc lamp (D2) Square Wave Pulse 100Hz Self reversal (SR) background, 400Hz Deuterium Arc (D2) background 1800 grooves/mm diffraction grating 250nm 300nm 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable) Automatic Single Beam ± 0.15nm 0.2nm ± 0.02nm < 0.05nm 0.005Abs/30min Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs Flame Types Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG) Sensitivity (Cu) 2ug/ml Absorption >0.28Abs Characteristic Concentration Cu < 0.02ug/ml, Ba < 0.15mg/ml (N20/Acetylene) Detection Limit Cu < 0.004ug/ml Repeatability Cu < 0.7% (Air/Acetylene Flame) Ba < 1.0% (Nitrous Oxide/Acetylene Flame) Burner heads Titanium Alloy Nebuliser High efficiency glass, Acid proof available as an option Pre-mix Chamber Corrosion Resistant Atomiser Selection Automatic changeover (A3FG), Manual (A3F) Safety Features Burner identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor, Drain Trap Sensor, Power Loss Protection Graphite Furnace Analysis Graphite Head Transversally Heated Temperature Range Ambient - 3000 0 C Heating Program Up to 10 steps. Drying, Ashing, Atomisation, Cleaning Feedback Voltage and Optical temperature control feedback Sensitivity (Cu) 50ng/ml Absorption > 0.40Abs Detection Limit Cd < 0.004ng/ml Repeatability Cu < 2.0%, Cd < 2.0% Graphite Tubes Pyrolytically Coated with Platform Sample Size Up to 20ul Graphite Cooling Water Circulator Available Safety Features Argon Pressure Sensor, Water Flow Sensor, Over Temperature Sensor, Broken Tube Protection 5. 6

Data Processing PC System PC, Windows 7 Professional Operating System Operating Program AA Win Pro software Analytical Methods Flame AA, Flame AE, Graphite Furnace, Hydride Generation Readout Mode Continuous, Manual, Peak Height, Peak Area Calibrations Multi-Standard Calibration, Standard Addition, Interpolation Data Storage Analytical results, instrument and measurement parameters, signal profile, calibration curve Power Requirements Main Unit 220VAC 50/60Hz Graphite Power Supply 220VAC 50/60Hz Instantaneous power 5KW Current rating 7KW Dimensions Main unit Graphite Power Supply 110cm x 54cm x 54cm 75Kg 50cm x 54cm x 54cm 70Kg Standard packaging A3F 1 Main unit 1 A3 instruction Manual 1 Cook Book 1 Safety Manual 1 System validation document 1 Data coded Air/Acetylene burner 1 Glass Nebuliser 8 Hollow cathode Lamp Holders 2 Power Cables 1 Gas tubing Air 1 Gas Tubing Acetylene 1 Drain Trap and Tubing 1 Tool Kit 1 Various gas Fittings A3G 1 Main unit 1 A3 instruction Manual 1 Cook book 1 Safety Manual 1 System Validation document 8 Hollow cathode Lamp Holders 2 Power Cables 1 Tool Kit 1 Various Gas Fittings 10 Graphite Tubes 1 Gas Tubing Argon 1 Connection Cable (Graphite) 1 Pipette 1bag Pipette Tips A3FG 1 Main unit 1 A3 instruction Manual 1 Cook Book 1 Safety Manual 1 System validation document 1 Data coded Air/Acetylene burner 1 Glass Nebuliser 8 Hollow cathode Lamp Holders 2 Power Cables 1 Gas tubing Air 1 Gas Tubing Acetylene 1 Drain Trap and Tubing 1 Tool Kit 1 Various gas Fittings 10 Graphite tubes 1 Gas Tubing Argon 1 Connection Cable (graphite) 1 Pipette 1bag Pipette Tips

AA-Win Pro Software is a powerful and intuitive software product designed to allow control and data acquisition from the A3 series Atomic Absorption Spectrometer. The AA-Win Pro software allows the Analyst to control all aspects of their analytical method whilst providing an extensive range of tools for data collection, storage and interpretation. The software interface consists of three key workareas, whilst having toolbars to access many others. These work areas allow the user to view real-time signal acquisition, up-to-date display of calibration curves and a flexible, sample table. Lamp turret setup, operating and warm-up currents, along with the desired analytical wavelength are easily selected in the configuration. 7. 8

Ensure optimal peak position at the chosen analytical line by scanning the emissions spectra. Use the sample table to perform quick measurements of both Standards and Samples. Easily append the sample table to add new samples or even revise calibration curves either by manual introduction or using an Autosampler. Each stage of analysis setup is made quick and simple by means of the Sample Wizard. View up-to-date calibration curves in 1st, 2nd, or 3rd order using a standard calibration or standard addition. Perform retrospective curve fits to ensure optimum corre-lation. Obtain reliable and accurate results by using the Energy control feature to manually optimise atomiser position and setup, View real-time signal acquisition for flame, graphite furnace and hydride generation analysis. Use the Auto-balance feature to ensure energy level, and optical alignments are optimised when using background correction.

The AS3 Autosampler is an accessory specifically designed for the A3 Atomic Absorption Spectrometer. The AS3 can be used to automatically introduce standard and unknown samples to the atomiser for analysis. It can be used with both flame and graphite furnace instruments. Flame Analysis 38 sample positions (6 for standard samples, 32 for unknown samples). Sample vial size 6ml Standard sample vial size 12ml Pressure protection for wash Position adjustment by AA-Win Pro software Reproducibility Cu < 0.6% (air/acetylene) Cu< 1.0% (air/lpg) Ba <1.0% (nitrous oxide/acetylene) Graphite Analysis 76 sample positions (10 for standard samples, 6 for modifier solutions, 60 for unknown samples) Sample vial size 1.5ml Modifier vial size 12ml Pressure protection for wash Up to 3 modifier additions Position adjustments by AA-Win Pro software Reproducibility Cu <2.0%, Cd <2.0% Nitrous Oxide/Acetylene Burner(500-023) Titanium alloy construction 50mm single slot Coded for safety Direct replacement for standard burner Designed for higher temperature flame Adjustment of burner rotation for sensitivity optimisation Air/Propane(LPG)Burner(500-030) Titanium Alloy construction 3 slot burner Coded for safety Direct replacement for standard burner Designed for lower temperature flame Adjustment of burner rotation for sensitivity optimisation Acid resistant Nebuliser(500-010) Resistant to most acid samples Higher uptake rate fo improved high solids samples Higher air pressure required Robust construction Fixed flow for easy installation Graphite Tube Without Platform(500-006) Pyrolytically coated graphite tube No platform fitted giving a faster response for refractory elements High quality long life tubes Can be used for larger samples <20ul 9. 10

Hydride Unit(500-007) Universal design Full reaction cycle from press of start button Supplied with temperature controlled heated absorption cell Cell is easily installed with burner attachment Can be used for Mercury cold vapour analysis Sensitivity for most elements <lng/mi Only 2.0mi - 2.5ml per sample required RSD < 3% Quick analysis < 30 seconds per measurement Acetylene Flame Arrestor(GS-004) Gas Regulators (GS- 001,GS-002,GS-006,GS-007) Hollow Cathode Lamp Direct fitting to gas regulator output Required for acetylene gas Non-resetting easy to replace Direct fitting to gas cylinder Comply to British Standards Supplied with hose fitting and crimp Various gas cylinder fittings available Regulators for Air, Acetylene, Nitrogen, Argon, Nitrous Oxide, LPG Specify fitment to European standard Sharp line source About 5000 milliampere-hours Water Circulator(GS-005) Cooling capacity 2000W Temperature range 0-50 Temperature accuracy 1 Maximum input power 1000W Fuse 10A Power 220V 50Hz Work Pressure 0~0.6MPa Rated flow rate 3.5L/min Rated lift 10M Tank capacity 32L Noisiness <65 Dimension(L W H) 600 400 900 Weight 50Kg Air Compressor(GS-003) Rated discharge pressure: 0.3Mpa Output rate: 0.3-0.9m3/h (adjustable) Noise: smaller than 55dB Power supply: AC220V 50HZ Dimension: 400 300 620(mm) Ambient condition: ambient temperature less than 35 Relative humidity less than 80%

PERSEE ANALYTICS, INC. A f f o r d a b l e L a b T e c h n o l o g y PERSEE ANALYTICS, INC. Represented by Giangarlo Scientific Company, Inc. 162 Steuben Street Pittsburgh, Pa. 15220 Web www.giangarloscientific..com Tel. (412) 922-8850 E-mail sales@giangarloscientific..com