GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Similar documents
Toxic Gas Detection. Model F12. Toxic Gas Detection

Model D12. Digital Gas Transmitter

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model D12-IR. Digital Gas Transmitter...

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

UniSens 2-Wire Gas Transmitter

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Two-Channel Gas Controller

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Sieger Apex. Flexibility that meets your requirements

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Oxygen (O2) Single-Point Gas Detection System

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor...

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Frequently Asked Questions

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Series D12 Toxic Gas Transmitter

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Combustible Gas Detection and Control System

OLC(T) 100 FIXED GAS DETECTOR

GAS DETECTOR ST400EC PART.NO

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Equipment. Model R002. Description. SF6 leak detector

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

IGD.CO.UK

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

GLD-30 Gas Leak Detector

GAS MONITOR Model Model

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

ALTAIR 5X Multigas Detector Product Specification

Model OEM-2 INSTRUCTIONS FOR USE

3M Oldham OLCT 100. Description. Fixed Gas Detector

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Series F12 Toxic Gas Transmitter

Commercial and Light Industrial Fire Alarm Control Panel

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Series F12/D Toxic Gas Transmitter

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

FX-SMT Series INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038

Toxic Smarter Transmitter Instruction Manual

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Warranty Registration

Beacon 110 Gas Monitor Operator s Manual

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Instructions TXL Series Oxygen and Toxic Gas Detectors 4/

Pioneer-R16 Gas Monitor Operator s Manual

SAFESITE Multi-Threat Detection System

Model 4001 Series Single Channel Controller

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Instructions Toxic Gas Controllers R8471D/F/G Chlorine/Sulfur Dioxide/Nitrogen Dioxide 1.1 8/

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Products and performance

Stand Alone DYNAGARD SP Operation Manual

MODEL GT812 NOVA-SENSOR ELITE TOXIC GAS DETECTOR

Inc Series Digital Gas Detector/Controller. Operation Manual

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

Controllers. Instruction Manual WARNING

GasAlertMicroClip X3 Specifications

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Honeywell EC-P2 EC-P2. Gas Detector CHARGE BATTERY WHEN NOT IN USE. Instruction Manual

APPLICATION DATA SHEET

SP-220. Features. Combustible handheld gas leakage detector

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

ACCURATE ELECTRONICS INC

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

incontrol Systems Inc. Flame and Gas Detection

R.I.S. (Remote Intelligent Sensor)

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Macurco DVP-120 Detection and Ventilation Control Panel

SEC 2000 Millenium Infrared Gas Detector

Transcription:

GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and petrochemical plants to food processors, the GasSens system can be applied to the simplest or most complex gas detection application. Economical and low maintenance, this system is your best choice for reliable leak detection. GasSens detection systems consist of individual modules that can be located where required. Sensor/transmitters, located in the area where gas leakage or buildup might occur, provide the basic measurement for the system. Sensor transmitters are available in either NEMA 4X or explosion-proof versions and can be supplied with ATI s exclusive Auto-Test automatic sensor testing system, greatly reducing operator testing requirements. Receiver modules provide the electronic brains for the detection and alarm system. Each compact module includes a digital display of gas concentration, isolated analog output, and 4 relay outputs. Receivers may be located up to 1000 feet from sensor/transmitters for remote indication, or can provide local control functions such as valve shutoff while transmitting a 4-20 ma signal to remote displays or data loggers. Universal power supply modules provide DC power to receivers. The power supply is housed in a compact module similar to the receiver, and will accept inputs from 85 to 265 volts, AC or DC, without adjustment. The power supply also provides a power failure relay and charging for an optional battery back-up unit. Applications include: Chemical plants; pulp & paper mills; semiconductor fabrication; food processing; water treatment; mineral processing; wastewater treatment; parking facilities; gas processing; and petroleum refining. Gas & Range Availability Gas Minimum Maximum Range Range Acid Gases 0-10 PPM 0-100% Alcohol 0-500 PPM 0-2000 PPM Ammonia 0-50 PPM 0-500 PPM Arsine 0-1000 PPB 0-10 PPM Bromine 0-1 PPM 0-100 PPM Carbon Monoxide 0-50 PPM 0-500 PPM Chlorine 0-1 PPM 0-100 PPM Chlorine Dioxide 0-1 PPM 0-100 PPM Combustible Gas 0-50% LEL 0-100% LEL Diborane 0-1000 PPB 0-10 PPM Ethylene Oxide 0-20 PPM 0-200 PPM Fluorine 0-1 PPM 0-100 PPM Formaldehyde 0-20 PPM 0-200 PPM Germane 0-1000 PPB 0-10 PPM Hydrogen 0-2000 PPM 0-10% Hydrogen Chloride 0-10 PPM 0-100 PPM Hydrogen Cyanide 0-10 PPM 0-100 PPM Hydrogen Fluoride 0-10 PPM 0-100 PPM Hydrogen Sulfide 0-10 PPM 0-100 PPM Hydrogen Peroxide 0-10 PPM 0-100 PPM Hydrogen Selenide 0-1000 PPB 0-10 PPM Iodine 0-1 PPM 0-100 PPM Nitric Oxide 0-20 PPM 0-250 PPM Nitrogen Dioxide 0-10 PPM 0-100 PPM Oxygen 0-5% 0-35% Ozone 0-1 PPM 0-100 PPM Phosgene 0-2 PPM 0-100 PPM Phosphine 0-1000 PPB 0-10 PPM Silane 0-10 PPM 0-50 PPM Sulfur Dioxide 0-10 PPM 0-100 PPM

Receiver Module Receiver modules provide an interface between the detection system and external alarming and data logging requirements. One module is used with each sensor/transmitter and includes a variety of features: LED Display: Indicates gas concentration directly in PPM, PPB, or %. The display may be operated in high intensity (sunlight readable) mode for outdoor use or in normal mode for indoor applications. Analog Output: An isolated 4-20 ma output is standard. The output will drive loads up to 1000 ohms for use in recording, data logging, or computer input. Two Alarm Setpoints: Alarm setpoints are factory adjusted to standard values but may be set to any value from 5% to 100% of range. Front panel LED s marked Warning and Alarm indicate the status of each alarm setpoint. A standard alarm delay of 2 seconds or a longer delay of 10 seconds may be selected. In addition, alarms may be switch programmed to activate either above or below the setpoint. Three Alarm Relays: Output relays are SPDT with unpowered contacts for use in activating external signaling devices, control elements, or for input to telemetry or annunciator systems. Each relay may be assigned to either alarm setpoint for application flexibility. Relays are factory set to energize on alarm, but may be switch programmed for fail safe operation. Relays may also be set for either latching or non-latching operation. Trouble Alarm & Relay: Should the sensor/transmitter input be lost, a trouble light (LED) on the front panel will flash and an associated relay will activate. For those systems equipped with the sensor Auto-Test feature, this alarm will also activate if the sensor does not respond to the automated gas test. Front Panel Reset Switch: A single front panel switch marked A/R (Acknowledge/ Reset) serves a number of functions. When an alarm occurs, the switch will silence an audible horn wired to the module and will change the alarm lights from flash to steady on. After the alarm condition has cleared, the switch may be used to reset any latching alarms. The switch will also activate an electronic module test, inhibit alarm contacts, and activate the Auto-Test. Remote Reset Input: Terminals are provided for connection of a remote reset switch so that alarms can be acknowledged from a remote location or through a telemetry system. Pluggable Terminal Blocks: External electrical connections are made to plug-in terminal blocks. Should module service ever be needed, modules can be replaced in minutes. Receiver module Power supply & receiver DIN rail mounting

Standard sensor/transmitter Explosion-proof sensor/transmitter Transmitter with auto-test Electrochemical sensor GasSens gas detection systems employ electrochemical sensors developed and manufactured by ATI. Expertise in electrochemistry and sensor design provides the foundation for leak detection systems that perform continuously with minimal maintenance. Sensors are rated for ambient temperatures from -25 to +50 C, allowing both indoor and outdoor applications. Excellent zero stability and high sensitivity and selectivity combine to make ATI sensors the best available on the market today. Gas sensors are closely coupled to a digital transmitter for excellent noise immunity and the ability to transmit long distances using unshielded cable. The transmitter is powered from the A major expense in gas detection systems is the cost of regular testing to ensure that sensors are responding. This requires a technician to inspect sensors weekly and apply a small amount of gas manually to check response. ATI has developed a unique system to reduce this maintenance requirement. Available on most ATI digital sensor/transmitters is an option called Auto-Test. This option consists of an electrochemical gas generator closely coupled to the sensor. Every 24 hours, the receiver automatically activates the generator, producing a small amount of gas that diffuses into the sensor, just as it would if a gas leak occurred. The microcomputer in the receiver analyzes the output of the Sensor/Transmitter receiver module and uses a unique current pulse position technique to send information to the receiver over a two wire connection. The receiver connection is not polarity sensitive, virtually eliminating the possibility of incorrect transmitter wiring. Sensor/transmitters can be located up to 1000 feet from receiver modules. Sensor/transmitters are housed in shielded NEMA 4X enclosures for use in almost any industrial environment and are designed to meet intrinsic safety standards. An explosion-proof version of the transmitter is also available for applications where this type of protection is preferred. Combustible gas transmitters are always explosion-proof. Sensor Auto-Test transmitter to determine that the sensor is responding normally. When proper sensor response is detected, the generator is turned off and the system goes back to normal operation. If no sensor response is detected, the TROU- BLE light on the receiver will flash and the trouble relay will activate. During testing, alarm relays are inhibited so that external alarms are not activated. The Auto-Test feature ensures that each sensor is regularly tested with gas. Premature sensor failure or blockage of the sensor membrane is quickly detected. In addition, self-testing will alert maintenance personnel when a sensor has reached the end of its useful life. Since sensors normally last anywhere from 12 months to over 3 years, this feature allows users to determine when sensor replacement is needed.

Power Supply Module To meet the needs of users throughout the world, ATI has developed a compact universal power supply in a DIN rail module similar to the receiver. The power supply will accept any AC or DC input from 85 to 265 volts, without adjustment. No jumper changes or selection switches are required, and large variations in input voltage do not affect power supply operation. This power supply is suitable for operation of one or two receiver modules. The power supply provides three 12 VDC output connections, two of which are designated for receiver module connection. A third connection is provided to automatically charge the optional external battery backup system. The power supply module is protected by a fuse conveniently located in a removable holder accessible from outside the module. For external power failure indication, the power supply contains a SPDT relay. The relay is normally energized, and de-energizes on power failure. Battery Back-Up Battery back-up systems are used in gas detection applications to ensure that detectors remain operable, even when AC power fails. ATI offers a separate battery back-up unit that maintains power to detection equipment in the event of a power interruption. The battery back-up system consists of a rechargeable sealed lead acid battery housed in a NEMA 4X enclosure. An electronic circuit attached to the battery controls the charging rate and will disconnect the battery from the system if the battery voltage drops to a level where battery damage might occur. Charging is provided by the power supply module. Battery back-up units will operate a single point detector for a minimum of 12 hours and an average of 24 hours. Two point systems will be maintained for 6 hours minimum and an average of 12 hours. The actual battery back-up time depends on whether the LED display is operated in high intensity mode and whether relays are in fail-safe mode (normally energized). Horn/Strobe Options A weatherproof piezoelectric audible horn is available for all gas detectors. The horn operates from 12 VDC supplied by the power supply module and can be activated from single or multiple receiver modules. The horn mounts easily in one of the enclosure knockouts, and produces an 85 db signal for local alarming. A 12 VDC strobe is available for enhanced visual alarm indication. The strobe uses a xenon lamp with a bright 1/2-million CP flash firing 70 times/minute. Strobe housing is weatherproof lexan with red lens, and mounts to 1/2" conduit.

Receiver & Power Supply Enclosures A variety of NEMA 4X enclosures are available to house receiver and power supply modules. ATI offers standard enclosures to house up to 6 modules, and can supply large enclosures for systems requiring more points of detection. System integrators can use standard 35 mm DIN rail mounting modules in their own enclosure. Single Module Enclosure: Houses a single receiver module for use in DC powered applications where the user supplies the DC power to the system. Two Module Enclosure: Houses two receivers or one receiver and one power supply. Normally used for single point AC powered detectors. Three Module Enclosure: Accommodates two receivers and power supply or three receivers. Used mainly for two point detection systems. Six Module Enclosure: Suitable for two power supplies and four receivers or six receivers. This enclosure is used primarily for four point gas detection systems. Special Enclosure: Custom enclosures are available to handle systems of any size. Your ATI representative can assist with system designs for larger applications.

Specifications Receiver Module Construction Display: Input: Output: Alarms: 4 digit LED, sunlight readable Digital signal, 2 wire connection to remote sensor/transmitter Isolated 4-20 ma DC, 1000 ohms maximum load Two adjustable concentration alarms, set points adjustable from 5-100% of range Alarm Indicators: High intensity LED bars for WARNING (low setpoint) and ALARM (high setpoint) Indicator Function: WARNING indicator non-latching, ALARM latching Alarm Relays: Three assignable alarm relays, 10 A, 120 VAC (5 A, 250 VAC) resistive Alarm relays assignable to either alarm set point Relay Function: Configurable for normal/fail-safe, latching/nonlatching, and fast/slow operation Relay & Indicator Reset: Activated from front panel switch or through remote reset Trouble Alarm: Front panel LED indicator and SPDT, 10 A, 120 VAC (5A, 250 VAC) resistive relay; Relay factory set to fail-safe operation Trouble Function: Indicates loss of sensor/transmitter input or failure of sensor Auto-Test (if in use) Gas Indicator: LED bar on front panel with gas symbol overlay Mounting: Module mounts to 35 x 7.5 mm DIN rail Electrical Connection: Quick disconnect plug-in terminal blocks Module Enclosure: Noryl Size: 2.8"W x 3.6"L x 2.3"D (70 mm x 90 mm x 58 mm) Operating Temperature: -40 to +55 C Humidity: 0-99% non-condensing Power: 9-15 VDC, 300 ma maximum Module Enclosures Single Module Enclosure: Two Module Enclosure: Three Module Enclosure: Six Module Enclosure: NEMA 4X polystyrene, 4.33"W x 7.09"H x 4.33"D (110 x 180 x 110 mm) NEMA 4X polystyrene, 7.17"W x 7.09"H x 4.33"D (182 x 180 x 110 mm) NEMA 4X polystyrene, 10.0"W x 7.09"H x 4.33"D (254 x 180 x 110 mm) NEMA 4X polystyrene, 10.0"W x 14.21"H x 4.33"D (254 x 361 x 110 mm)

Sensor/Transmitter Measurement: Transmitter Type: Sensor: Accuracy: Zero Drift: Enclosure: Optional Enclosure: Gas type and range customer specified Two wire system, current pulse position signal Electrochemical gas diffusion type (manufactured by ATI) Generally ±5% of value, but limited by available calibration of gas accuracy. Sensor dependent but normally less than 2% per month, non-cumulative NEMA 4X polystyrene Explosion-proof cast aluminum, Class I, Division I, Group B, C, & D Electrical Connection: Connection Distance: Operating Temperature: Humidity: Option: Quick disconnect terminal blocks (two wires without polarity) Up to 1000 feet (300 m) to receiver -25 to +55 C (-5 for oxygen) 0-95% non-condensing Sensor Auto-Test (available for most gases) Size (Sensor Transmitter with Auto-Test): 3.7"L x 6.5"W x 2.2"D (94 mm x 163 mm x 57 mm) Power: 12 VDC from receiver module Power Supply Module Input Voltage: Output Voltage: Output Connection: 85-265 VAC, 50/60 Hz, or 85-265 VDC, self regulating Regulated 13.7 VDC, 1A 3 separate connections, two for receiver modules, and one for external battery back-up Alarm: Loss of input power alarm relay, SPDT 10 A, 120 VAC (5A, 250 VAC) resistive Operating Temperature: -40 to +55 C Humidity: 0-99% non-condensing Module Enclosure: Noryl Size: 2.8"W x 3.6"L x 2.3"D (70 mm x 90 mm x 58 mm) Electrical Connection: Quick disconnect terminal blocks Mounting: Module mounts to 35 x 7.5 mm DIN rail Battery: Charge Control: Battery Back-Up Low Voltage Cutoff: Fault Protection: Enclosure: Size: 12 VDC, 4 Ampere hour Current limited to.75 A max. Relay disconnect at 10 VDC Relay disconnect on shorted charger wiring NEMA 4X polystyrene 4.33 W x 7.09 L x 3.54 D (110 mm x 180 mm x 90 mm)

Ordering Information Specify modules using the coding system below. Generate a part number for the receiver and sensor/transmitter. Then select power supply and enclosure options as required. C D E F Model A14/A11-CC-DDDD-E-F Alarm Module: - - - Receiver Module + Sensor/Transmitter Suffix CC - Gas Type - Standard range shown in parentheses 10 - Bromine (0-2 PPM)* 11 - Chlorine (0-10 PPM)* 12 - Chlorine Dioxide (0-2 PPM)* 13 - Fluorine (0-2 PPM)* 14 - Ozone (0-2 PPM)* 15 - Ammonia (0-100 PPM)* 16 - Carbon Monoxide (0-100 PPM)* 17 - Combustible Gas (0-100% LEL) 18 - Hydrogen (0-4%) 19 - Oxygen (0-25%) 20 - Phosgene (0-2 PPM) 21- Hydrogen Chloride (0-20 PPM)* 22 - Hydrogen Cyanide (0-20 PPM)* 23 - Hydrogen Fluoride (0-20 PPM)* 24 - Hydrogen Sulfide (0-50 PPM)* 25 - Nitric Oxide (0-100 PPM) 26 - Nitrogen Dioxide (0-20 PPM)* 27 - Sulfur Dioxide (0-20 PPM)* 28 - Arsine (0-1000 PPB) 29 - Diborane (0-1000 PPB) 30 - Germane (0-1000 PPB) 31 - Hydrogen Selenide (0-1000 PPB) 32 - Phosphine (0-1000 PPB) 33 - Silane (0-10 PPM) 34 - Hydrogen Peroxide (0-10 PPM) 35 - Iodine (0-2 PPM)* 36 - Acid Gases (0-10 PPM)* 37 - ETO (0-20 PPM)* 38 - Formaldehyde (0-20 PPM)* 39 - Alcohol: Consult Factory *Indicates Auto-Test option available for standard range or below. Suffix DDDD - Range Code the measurement range using a four digit number. The standard ranges are shown under Suffix C above. For 0-10 PPM chlorine, the code would be 0010. For 0-200 PPM ammonia, the code would be 0200. Suffix E - Units of Measurement 1 - PPM 2 - PPB 3 - % 4 - % LEL Suffix F - Auto-Test System 1 - Without sensor Auto-Test function 2 - With sensor self-test Options and System Enclosures 80-0005 Single Module Enclosure 80-0006 Two Module Enclosure 80-0007 Three Module Enclosure 80-0033 Large Three Module Enclosure 80-0008 Six Module Enclosure 80-0027 Large Six Module Enclosure 80-0024 Nine Module Enclosure 80-0026 Twelve Module Enclosure 00-0055 Power Supply Module 28-0004 65 Watt Power Supply (for up to 12 Receivers) 00-0057 Battery Backup Unit 00-0058 Audible Horn 35-0008 Horn, Industrial External 120 VAC 35-0002 Strobe with red lens, 12 VDC 35-0005 Strobe with red lens, 120 VAC 00-0118 Calibration adapter for A10 sensor 00-0258 Calibration adapter for C10 explosion-proof sensors (combustibles) 00-0261 Remote calibration adapter for combustible sensor 45-0046 Rain Shield for C10 explosion-proof sensors (combustibles) 00-0253 Flowcell assembly for A10 sensor 00-0298 Flowcell assembly for C10 explosion-proof sensors Represented By: Analytical Technology, Inc. 6 Iron Bridge Drive Collegeville, PA 19426 Phone: 610/917-0991 Toll-Free: 800/959-0299 Fax: 610/917-0992 E-Mail: sales@analyticaltechnology.com Web: www.analyticaltechnology.com ATI (UK) Limited Bank Chambers, 33 Stamford Street Mossley, Aston-u-Lyne OL5 0LL Phone: +44 (0) 1457 832800 Fax: +44 (0) 1457 83950 E-Mail: sales@atiuk.com