ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT

Similar documents
ENVIRONMENTAL STANDARD OPERATING PROCEDURE 23 WEAPONS CLEANING

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

OTC Model Rule for Solvent Degreasing 2012

Guidance Document for the Halogenated Solvent Cleaner NESHAP - Forms Only Version

SOLVENT CLEANING OPERATION EQUIPMENT SUMMARY FORM-44 Page 1 of 7

Chapter 3: Emergency Planning for Laboratories

ENVIRONMENTAL HEALTH AND SAFETY. Power Washing Guidelines

PARTS CLEANING AND DEGREASING

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

5.0 CONTINGENCY PLAN. It is necessary to amend the plan if:

Zep Dyna Clean Installation and Operator's Manual

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

Protocol for Chemical Spills. By Gordon Krueger Environmental Safety Specialist University of Northern Iowa Environmental Health and Safety

INDEX 100 GENERAL 101 PURPOSE 102 EXEMPTION, VACUUM CONDITION 103 EXEMPTION, VAPOR PRESSURE

SAFE WORK PROCEDURE. List the Hazards and risk controls as per risk assessment. assessment reference:

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

California State University Bakersfield Radiation Safety Program Revised November 2017

Vision Painting Inc. Safety Management System

WorkSafe ACT. Safe Work Procedures. Updated: Thu, 11 Nov :39: Overview

CNS Cleanroom Safety Orientation Form

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

WESTERN CONNECTICUT STATE UNIVERSITY HAZARDOUS WASTE CONTINGENCY PLAN PROCEDURE E-115

2 (Section 1.0) & Yellow Book

Ontario Region POLLUTION PREVENTION FACT SHEET. Pollution Prevention Program - Federal Programs Division

PURPOSE OF THE PROCEDURE

1. Researchers are familiar with the location and contents of: The lab s Chemical Hygiene Plan YES NO

Management of Solvents and Wipes in the Printing Industry

Small Business Assistance Program Metal Finishers Compliance Checklist

Industrial Parts Cleaner Operator's Manual

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Hazardous Waste Self Audit

6.0 Emergency preparation

Access Controls for High Radiation Areas NISP-RP-05

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

INDUSTRIAL - AQUEOUS PARTS CLEANER EM5 5 GALLON BENCH TOP

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

HOT WORK OPERATIONS March 23, 2018

Perchloroethylene in Dry Cleaning

This plan, its contents, and emergency notification procedures shall be made available to all appropriate university employees.

The University of Washington Nanofabrication Facility (WNF) at Fluke Hall 125 Fluke Hall Seattle, WA 98195

LABORATORY SAFETY SERIES: Flammables & Explosives

Safety In Chemistry. Identified Risks and Hazards

UNIFIED INTERPRETATION OF PROVISIONS OF IMO SAFETY, SECURITY, AND ENVIRONMENT-RELATED CONVENTIONS

Industrial Parts Cleaner with Manual or Auto Lid and Electric or Air Pump Operator's Manual

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

POLICY STATEMENT: Policy Number: Section 600 Physical Plant. Date Adopted: May 7, Date(s) Revised: September 4, 2012

Emergency Response. Types of Emergencies

Subject: Hazardous, Universal, and Non Hazardous Waste Accumulation Site Management

Annual Tune-Up Procedure

INDUSTRIAL - AQUEOUS PARTS CLEANER EM1435A AIR OPERATED

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

Permitting and Licensing for Hazardous Material Use and Storage

OPERATION & MAINTENANCE

NESHAP 6W Notification of Compliance Status

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

Operator s Manual. Histology Bath

Material Safety Data Sheet

STUDENT SAFETY RULES

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008

Publication No. AAMA Voluntary Guide Specification for Cleaning and Maintenance of Painted Aluminum Extrusions and Curtain Wall Panels

CLEANING AND SANITIZING

University of California, Davis Laboratory Self-Inspection Checklist

BETACURE 100 CO-REACTANT

LS Series Solvent Recovery Systems

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

VEHICLE SERVICE FACILITIES Best Management Practices

IYRS School of Technology & Trades RCRA CONTINGENCY PLAN Bristol Facility 40 CFR 265 Subpart D 29 CFR Emergency Evacuation

Fume Hood Safety TYPES OF FUME HOODS

MATERIAL SAFETY DATA SHEET 3M Tapes: 3900, 3939, 6969, 2929, 5959, 8979, 8979N, and /19/13

PARTS WASHER Model: CW2D Part No:

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

EMERGENCY PHONE: or (651) (24 hours)

This policy is applicable to all DMS-owned, -leased and -managed facilities.

HEALTHCARE SAFETY INSPECTION

MATERIAL SAFETY DATA SHEET 3M Micropore Surgical Tape 1530, 1530S, 1530B, 153NS, /24/12

INDUSTRIAL - AQUEOUS PARTS CLEANER EM4000

EPISD RISK MANAGEMENT. Custodial Safety

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

EMERGENCY PHONE: or (651) (24 hours)

INDUSTRIAL - AQUEOUS PARTS CLEANER EM6000

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION

Non Ionizing Radiation Audit checklist

Hazardous Materials Risk Management. Chris Hipple Leavitt Recreation & Hospitality Insurance

OHIO UNIVERSITY RADIATION SAFETY REVIEW

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.

North Dakota State University Laser Safety

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS

Chapter 10: Laboratory Equipment

Office of Research Safety Laboratory Safety Manual 215 Chemical Spill Response

Laboratory Safety Laboratory Inspection Checklist

The Western Lake Superior Sanitary District

Transcription:

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT 1. Version, Date. 3, 07 Sep 2014 (EMS) 2. Purpose. This Environmental Standard Operating Procedure (ESOP) establishes general use procedures for solvent-based parts washers as required by Marine Corps Base, Quantico s (MCBQ s) Title V Operating Permit to prevent the emission of volatile organic compounds (VOCs) and release of solvents at the Base. Compliance with these Title V Operating Permit requirements is mandatory and will assist with the management of solvent-based parts washers at MCBQ in accordance with the Base s air operating permit and the Base s management of hazardous waste (HW). 3. Applicability a. Audience. This procedure applies to all personnel who manage or operate solvent-based parts washers. b. Scope. This procedure applies to the routine operation of all solvent-based parts washers at MCBQ. Related procedures are provided as separate ESOPs. 4. Definitions a. Immersion Parts Washing Machine. An immersion parts washing machine is a parts washer in which the parts are immersed in the solution during cleaning. b. Parts Washer. Parts washers are equipment used to clean parts and components as part of a manufacturing or maintenance operation. Parts washers include cold cleaning units, vapor degreasers and conveyorized degreasers. Parts washer cleaning solutions can be solvents or aqueous cleaners. This ESOP covers solvent-based parts washers. c. Personal Protective Equipment (PPE). PPE is equipment provided to shield or isolate a person from chemical, physical, and thermal hazards encountered with or around hazardous materials. d. Remote Reservoir Parts Washing Machine. A remote reservoir parts washing machine is a parts washer with liquid solvent that is pumped to a sink-like work area and immediately drains back into an enclosed container while parts are being cleaned, allowing no solvent to pool in the work area. e. Safety Data Sheet (SDS). SDSs are manufacturer generated form to provide workers and emergency personnel with proper information and procedures for handling or working with a particular product. These *This is an uncontrolled document printed for reference only. The current copy is online on the MCBQ SharePoint at: https://eis.usmc.mil/sites/mcbquan/g5/nrea/nrea%20branch%20documents/ Forms/AllItems.aspx

forms generally contain data related to physical and chemical characteristics, toxicity, health effects, first aid, reactivity, storage, disposal, protective equipment, and spill/leak procedures. f. Solvents. Solvents are petroleum-based products such as mineral spirits, Stoddard solvent, and petroleum naphtha, and organic products such as trichloroethane, trichloroethylene, benzene, and xylenes. g. Volatile Organic Compounds (VOCs). VOCs are organic compounds that are a component in significant atmospheric photochemical reactions as designated by the U.S. Environmental Protection Agency (EPA). VOCs react in sunlight to form ground level ozone, a major component of smog. 5. Responsible Parties. The following parties are responsible for activities described in this ESOP: a. Parts Washer Operators b. Shop Supervisors in which solvent-based parts washers are present c. Natural Resources and Environmental Affairs (NREA) Branch Air Program Manager (APM) d. NREA Branch Hazardous Waste Program Manager (HWPM) e. NREA Branch Environmental Compliance Section 6. Procedures a. Operating Solvent-Based Parts Washers (Instructions for Operational Control) shall: (1) Immersion and remote reservoir parts washing machines (a) Have a permanent, conspicuous label summarizing the operating requirements as shown in Good Operating Procedures for Cold Parts Washers (Attachment 7-1). (b) Be equipped with a cover that shall be closed at all times except during cleaning of parts or the addition or removal of solvent. (2) Solvent-based Parts Washer Operators shall: (a) Post the Good Operating Procedures for Cold Parts Washers (Attachment 7-1) at each solvent-based parts washer station. 2

(b) Refer to the applicable SDS based upon the solvent used and wear appropriate PPE (e.g., solvent impermeable gloves, goggles, apron, face shield). (c) Keep the solvent-based parts washer cover closed whenever not adding or removing parts to be cleaned. (d) Do not place solvent-based parts washers over or immediately next to floor drains. (3) Solvent-based parts washing machines shall be operated in accordance with the following guidelines: (a) Cleaned parts shall be drained at least 15 seconds or until dripping ceases, whichever is longer. Parts having cavities or blind holes shall be tipped or rotated while the part is draining. During the draining, tipping or rotating, the parts shall be positioned so that solvent drains directly back to the machine. (b) Flushing of parts using a flexible hose or other flushing device shall be performed only within the freeboard area of the machine. The solvent spray shall be a solid fluid stream, not an atomized or shower spray. (c) The spray nozzle shall be operated with no observable splashing of the solvent against the tank walls or the parts being cleaned. (d) The operator shall ensure that the solvent level does not exceed the fill line. (e) The operator shall ensure that, when the parts washing machine cover is open, it is not exposed to drafts or wind greater than 1.5 miles per hour. (f) Work area fans shall be located and positioned so that they do not blow across the tank lip of the parts washing machine at the same elevation. (g) Sponges, fabric, wood, leather, paper products and other absorbent materials shall not be cleaned in the solvent-based parts washing machine. (h) Spills during solvent transfer and use of the cold cleaning machine shall be cleaned up immediately, and the wipe rags or other sorbent material shall be immediately stored in covered containers labeled for disposal or recycling. (4) NREA Branch Environmental Compliance Section shall: (a) Ensure that solvent-based parts washers used aboard MCBQ do not exceed a vapor pressure of 1.0 millimeters of mercury (mm 3

Hg) at 20 degrees Centigrade (68 degrees Fahrenheit). Refer to the SDS Sheet of the solvent being used to determine the vapor pressure. (b) Collect pertinent solvent data from manufacturers as required by Virginia Department of Environmental Quality (VDEQ) as listed below: 1. The name and address of the solvent supplier. 2. The type of solvent including the product or vendor identification number. 3. The vapor pressure of the solvent measured in mm Hg at 20 degrees Centigrade (68 degrees Fahrenheit). (c) The NREA Branch Environmental Compliance Section will keep this data for a five year period and provide it to VDEQ upon request. b. Processing Waste Solvent from Solvent-Based Parts Washers (Instructions for Operational Control) (1) Appropriately trained personnel or contractors change the spent solvent. Solvent change-out occurs on a regular basis and the waste solvent is managed as follows: (a) Do not transfer waste solvent to another party for use or disposal. (b) Solvent in Safety-Kleen units is managed by Safety- Kleen. For all other brands of parts washers, contact the NREA Branch Environmental Compliance Section at (703) 432-4030 for storage and disposal assistance prior to the removal of fluids. (c) Store waste solvent only in closed and appropriately labeled containers. (2) The NREA Branch Environmental Compliance Section maintains a shipment log for all waste solvent. They may be contacted at (703) 432-4030 for other disposal issues. 7. Inspection and Corrective Action a. The NREA Branch Hazardous Waste Program is responsible for the following inspections and corrective actions: (1) Inspect parts washers every quarter using the MCBQ Work Center Compliance Checklist, Parts Washers (Attachment 7-2). (2) Maintain copies of the quarterly inspection records. 4

(3) Identify any new parts washers and add them to MCBQ s inventory. (4) Perform CAs needed to correct the problem(s) for all identified deficiencies. b. The APM is responsible for updating the procedure to reflect any changes related to MCBQ solvent-based parts washers in the air operating permit. 8. Internal Communication a. Report non-compliance with posted operating procedures to Parts Washer Operators and then to shop supervisors and document noncompliance on the quarterly inspection forms. b. Discuss and review the procedure and post changes to the procedure as needed. c. Post procedure and communicate changes to the parts washer operators, shop supervisor, and APM. 9. Training/Awareness a. NREA Branch, Hazardous Waste Program will identify any personnel requiring training on general use practices of parts washers, during quarterly inspections. In between courses, the NREA Branch may provide additional guidance per request. b. The NREA Branch Environmental Planning Section facilitates training on this ESOP to the target audience mentioned in paragraph 3.a c. The APM provides or facilitates an annual MCBQ Title V Parts Washer class, as needed, to ensure all responsible parties are aware of air permit requirements. 10. Emergency Preparedness and Response a. Parts Washer Operators immediately clean up spills that occur during operation of the parts washer or during solvent transfer using wipe rags and other absorbent material. Place wipe rags or other absorbent materials in closed and labeled containers for subsequent management. b. Parts Washer Operators should maintain adequate spill response materials near the parts washer. c. Report spills that cannot be cleaned up immediately to the MCBQ Fire Department (911). After notifying the MCBQ Fire Department, notify the NREA Branch (703-784-4030) of any materials that must be removed and disposed as hazardous waste. 5

11. References and Related Documents a. Virginia Air Pollution Control Regulations (9 VAC 5-40-6840A) b. MCBQ ISMP c. Good Operating Procedures for Cold Parts Washers (Attachment 7-1) d. MCBQ Work Center Compliance Checklist, Parts Washers (Attachment 7-2) e. MCBQ ESOP #2 - HW Storage Area 12. Document Revision History. The following provides a history of revisions of this ESOP: Revision Number Revision Date Revision Made By Organization or Section Paragraph Summary of Change & Reason 1 7/2008 Patti Greek Compliance All Grammar and technical revisions 2 11/2012 Andrew McClelland 3 03/07/14 Dave Grose Environmental Planning Compliance 3 Comment about SPM All Grammar and technical revisions Signature P. Greek A. McClelland D. Grose 13. Document Owner. This document has been reviewed and approved by the document owner. Any revisions or future updates to the procedure will be completed by the document owner as needed. a. Document Owner. Environmental Protection Specialist, Hazardous Waste Program, NREA Branch. b. Document Approval. Chair, E 2 MS Implementation Team. 6

GOOD OPERATING PROCEDURES FOR COLD PARTS WASHERS Virginia s air pollution control regulations (9 VAC 5-40-6840) require the following good operating procedures to minimize emissions of VOCs: The parts washer must remain closed except when in use. Store waste solvent only in closed containers. Cleaned parts should drain for at least 15 seconds or until dripping ceases. Tip and rotate the part so that solvent drains directly back into the parts washer. If used, the solvent spray should be a solid, fluid stream (not a fine, atomized or shower type spray) inside the parts washer. Pump-agitated baths must be operated with no observable splashing.* * Air-agitated baths may not be used. Do not operate the parts washer near a draft greater than 40 meters/minute (132 feet per minute or 1.5 miles per hour).** ** as measured between 1 and 2 meters (3.3 and 6.6 feet) upwind at the same elevation as the tank lip. Do not clean absorbent materials (such as sponges, fabric, wood, leather, and paper) in the parts washer. Clean up solvent spills immediately, and store wipe rags in a closed container for disposal or recycling. Position fans so that they do not blow across the parts washer opening. The solvent level must not exceed the fill line of the parts washer. The solvent vapor pressure must not exceed 1.0 mm Hg at 20 o C (68 o F). If you have questions regarding the parts washer, contact Andrew McClelland 432-0529. Attachment 7-1

MCBQ WORK CENTER COMPLIANCE CHECKLIST PARTS WASHERS Equipment: Unit: Parts Washer Operator/Phone: Process Equipment Requirements (emission unit ID#PW) Parts Washers Virginia Title V Air Permit Maintenance Inspection Building Location: No: Date of Inspector: Inspection: Limitations 1 Is the "Good Operating Procedures for Cold Parts Washers" sign placed in a visible location near the parts washer? 2 Is the degreaser cover kept closed when not handling parts in the washer? For machines where solvent drains directly into a remote reservoir, a perforated drain < 6 inches in diameter is an acceptable cover. 3 If the washer is equipped with a lid as a cover, is the lid easy to operate with one hand? 4 Does the solvent level not exceed the fill line? 5 If waste solvent is stored on site, is it kept in closed containers? 6 When spraying solvent, is the spray a solid, fluid stream that does not cause excessive splashing? 7 If cleaning pads are used, are they stored in a closed container outside of the parts washer? Yes No Comments Please describe any degreaser servicing and equipment changes here: Attachment 7-2