Testing Emission Source ITES Operating Manual OM

Similar documents
Design Manual Installation Operation Maintenance

Flame Simulator User Manual. Publication Rev. A

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Model TL104 MANTL104. Test Lamp for Flame Detection

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

Test Lamp for 210 series flame detectors Non EX

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

IPES-IR/UV Flame Detector Operating Manual R07

LEARNING SPECIAL HAZARD DETECTION TYPES


Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

150W Explosion Proof LED Light - 5' Tall Base Stand Mount - 24" Stand - Class I Div 1 C&D V

FLV 40 UV Flame Detector

Fire Detection System: An Overview

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

User Manual LIGHTMEN.COM. Apollo A75050

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

We offer ceramic radiant heaters and infra-red radiant tubes.

Cleaning Instructions for Symbol IP54 Devices

RK-05 Carbon Monoxide Detector Operator s Manual

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

SharpEye Flame Detector Selection Guide

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Symbols for Control Panels

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

BST-MG01 Single Gas Detecting Alarm Manual Instruction

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

Short Wave Infra-red Car Paint Curing Equipment. User Manual. Model: IR1 IR1+S3 ( ) ( )

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

OWNERS MANUAL OPERATION GUIDE

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Flame Detection Jon Sarfas

FagronLab NP-1 UV. Negative pressure workbench. User Manual

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Dräger Flame 2500 (IR3) Flame Detection

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

User manual UV Flash Dry C1

Dräger Flame 2500 Flame Detection

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Visit us at testo 835 Infrared and contact thermometer

Dräger Flame 2350 (UV&IR) Flame Detection

FIRE IR SENSOR Flame Detection

CCTV, HOW DOES IT WORK?

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

MSA s Guide to Selecting the Right Flame Detector for Your Application

s l it l on for Infrared Heaters

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Dräger Flame 2700 (Multi-IR) Flame Detection

FIREYE C9707A ALL FUEL SCANNER

Machine Mountable 360º Detector Model No C & M Instruction Manual

InstrumentationTools.com

Conspec - Why use our Flame Detectors

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

model No: ir20.v2 FUSE

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

B -MG0 i gle G Detecti A rm Ma a nstructio. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Gas Detection System SGAES-TG Operating Manual R01

RK-02 Multi Point Detector Operator s Manual

LED Spotlight 15 W. Information Sheet. Features. ISALUX 15 series

Open-area Smoke Imaging Detection (OSID)

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Basic Vehicle Fire Protection Manual

GIOTTO 80 design Roberto Paoli

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Laser Distance Sensor Type M Analog-Output

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

talentum Flame detection across the spectrum Range Brochure

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

62 MAX/62 MAX + Infrared Thermometer

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Dräger Flame 2100 (UV) Flame Detection

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Dräger Flame 2100 Flame Detection

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

FATG OM 0604 OWNERS MANUAL. Anywhere. Everywhere. Fresh Air... To Go.

Tornado Operations & Maintenance Manual

Rework: IR Technology vs. Convection Air

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes

Transcription:

San Jose CA 95112 Page 1 of 5 Testing Emission Source ITES Operating Manual 50017-001 OM

San Jose CA 95112 Page 2 of 5 1. Purpose The Testing Emission Source ITES GSKF.676216.001 (hereinafter after referred to as ITES) is intended for the functional testing of the IPES Flame Detectors (hereinafter after referred to as IPES), supplied by ESP Safety Inc, San Jose, CA, without removing it from the field. The radiation produced by this source approximates the radiation produced by petrochemical, natural gases, and other hydrocarbon flames or fires. 2. Basic Characteristics ITES generates directed modulated radiation with sufficient intensity to signal a flame or fire response, appearing on the IPES output, at a distance of 3 m (9.84 ft) (when used with a new battery set). The supply sources of the ITES are 3 D size Duracell mark batteries. ITES total operating time from one battery set is approximately one hour. Explosion proof mark 2ExeibIIВT4 X. Dimensions, 60 mm х 410 mm (2.36 in x 16.14 in) Weight (with batteries), 1.0 kg (2.2 lbs). The X symbol after the explosion proof mark means that under exploitation the ITES needs to be protected from impact and drop. 3. ITES Contents ITES is supplied to the customer pre-assembled with an emission source, housing, 3 D size batteries, an emission source for checking other types of power sources, and an Operating Manual. 4. Set-up Procedure (see Appendix) a. Remove back cover (1) of the ITES. b. Install 3 D size batteries into the ITES body (2). c. Replace the back cover (1). d. Check the functionality of the ITES. Press the on/off switch (3) and make sure the modulating radiation is present. e. Turn the reflector body (4) to obtain the minimum size and maximum brightness of the radiation spot at a distance of 1-2 meters (3.28 6.56 feet).

San Jose CA 95112 Page 3 of 5 Appendix 1 2 3 4 5 1 Back Cover 2 ITES Body 3 On/Off Switch 4 Reflector Cover 5 Glass Cover ITES is manufactured for the following types of IPES Flame Detectors. Reference designation of type Designation of Design document Table 1 Types of Flame Detectors Distance, ITES is provided the response from Flame detector ITES IR/UV IPES IR/UV Up to 3 m 50017-001 ITES IR3 IPES IR3 Up to15 m Note: UV- Ultraviolet, IR- Infrared

San Jose CA 95112 Page 4 of 5 5. Operating Procedure a. Point the ITES toward the IPES Flame Detector at a distance of up to 2 m (6.56 ft) and press the on/off switch (4). Adjust radiation as specified in section 4 (e). Direct the beam toward the IPES for 4-5 seconds. The IPES detection is indicated by a continuous LED lighted for 5 6 seconds. b. After the IPES has responded, switch off the ITES. c. Ensure that no water, dust or dirt is present on ITES s reflector. If there is evidence of dirt that is visible, then remove glass holder (5) and wipe the surface of the reflector with a wet clean coarse calico. If there is dirt under the radiation source, unscrew it from the holder and wipe with cotton wool GOST 5556, moistened with ethanol GOST 18300. d. Touching the glass bulb of the emission source, the surface of the reflector, or the protection glass is strictly prohibited!

San Jose CA 95112 Page 5 of 5 6. Probable Defects and Defect Elimination Defect Defect description Defect Elimination While switching on the ITES, the visual radiation is present, but a known good IPES doesn t generate a flame or fire response The ITES lamp is working in nominal mode because of a low power supply The reflector and/or the radiation source are dirty The distance to the IPES Flame Detector is too large Replace the batteries Clean the surface of the reflector and/or the radiation source Bring the ITES to a known good operational distance of 0.5-1 m (1.64 3.28 ft) from the IPES and check the IPES response There is no visible radiation while the ITES is switched on, the batteries are known to be good The ITES lamp is burnt out. Replace the lamp 7. Warranty The manufacturer guarantees trouble-free operation during the first 12 months after supplying the device to the customer. The warranty is not extended to the batteries and/or lamps used in the ITES. 8. Test Emission Source ITES IR/UV serial number is in accordance with technical requirements 50017-001. 9. Date of issue: " " 200. Signature of ESP representative (Name)