MovinCool Classic and Classic Plus Series. The Portable Spot Cooling Solution

Similar documents
MovinCool Pioneering Spot Air Conditioners Since 1982

Classic 10. Self-contained and portable, the Classic 10 requires little or no installation, simply roll it in, plug it in and turn it on.

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18. Unit Serial Number Range: 1111XXXX### to Present (From November 2011 to Present)

Portable Air Conditioning and Heating. reference GUIDE

Spot Coolers SUPERIOR PORTABLE COOLING AND HEATING. Portable Air Conditioning and Heating

OPERATION MANUAL U L US LISTED CM12 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

OPERATION MANUAL. CLASSIC PLUS 14 and CLASSIC PLUS 26 ~ SECTION EN FRANÇAIS

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT. DocID: 00G00025E

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48TM GAS HEATING/ELECTRIC COOLING UNITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

48TF GAS HEATING/ ELECTRIC COOLING UNITS

OPERATION MANUAL CLIMATE PRO 18

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

NQ Series Portable Chillers

TECHNICAL SPECIFICATIONS

OFFICE PRO 63 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SERVICE MANUAL OFFICE PRO 60. Unit Serial Number Range: 0407XXXX600 to Present (From April 2007 to Present)

CONDENSATE PUMP INSTALLATION MANUAL OFFICE PRO 10

OFFICE PRO 36 and OFFICE PRO 60 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

Commercial High-Efficiency Condensing Units

General Description. Operation

OPERATION MANUAL CM25. Unit Serial Number Range: 1009XXXXC25 to Present (From October 2009 to Present)

High Heat COP. High/Low Stage

Owner s Manual UnitSpecifications...3 RatingInformation...3. Models: TZ-12B& TZ-18B. Portable Air Conditioners

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SERVICE MANUAL OFFICE PRO 18 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00014EB

RACK-MOUNT Air Conditioners

OPERATION MANUAL U L US LISTED OFFICE PRO 36 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT IN- STALLATION AND USAGE, AND READ ALL SAFEGUARDS.

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

Using Portable Spot Air Conditioners in Industrial Applications


48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

LIFTAIRE II ELEVATOR AIR CONDITIONER

Q-TEC QC-Series Chilled Water Air Conditioner

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL SPECIFICATIONS

SPECTRACOOL INDOOR/OUTDOOR

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Product Data. Fig. 1 - Unit 50VR -A

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

5736 N. Michigan Road Indianapolis, IN 46228

Owner s Manual Unit Specifications...3 Rating Information...3. Built Right First... To Last! Warning!

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

MACH N-407 Heat Pump Air-Cooled Chiller

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

E Z S E R I E S " W X 16" H

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Q-Tec TM QC-Series Chilled Water Air Conditioner

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Split System Cooling Product Data

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

VariCool VAV Engineering Guide

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Liebert Mini-Mate2 1 To 8 Tons

OPERATION MANUAL OFFICE PRO W20. Unit Serial Number Range: 0211XXXXW20 to Present (From February 2011 to Present)

GREEN REFRIGERANT R-410A

SPECTRACOOL Indoor & Outdoor Air Conditioners

Installation plan: PG Mat. no Version 00 US

Split System Heat Pump Product Data

5) Do not start or stop the unit by inserting or pulling out the power plug.

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Split System Heat Pump Product Data

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

G /6000 BTU/Hr. 1172/1758 Watt

Transcription:

MovinCool Classic and Classic Plus Series The Portable Spot Cooling Solution

When the heat is on, turn on the MovinCool Classic & Classic Plus series People, processes, and equipment don t perform well under extreme heat. That s why more companies rely on the proven performance of our MovinCool Classic and Classic Plus series units to spot air condition their heat-sensitive areas. MovinCool s portable air conditioning system: Improves employee moral and manufacturing quality relieving workers from extreme environments to increase productivity and prevent heat exhaustion. Reduces excess cool-down time for production processes eliminating heat-related defects and additional scrap. Protects equipment from downtime due to heat saving systems from a costly failure or shutdown, which can cripple daily operations. DENSO, the pioneer of portable air conditioning and manufacturer of MovinCool is a registered ISO 9002 facility. Every unit passes through a series of performance tests to ensure 100% quality and is UL approved. So when the heat starts, stop it with the MovinCool Classic and Classic Plus portable air conditioning systems. Features Digital Temperature Controls Up to 26,000 Btu/h of Cool Air Economical Handles Wide Operating Temperature Ranges Rugged Reliable Design Dramatic Temperature Drop Totally Self-Contained No Costly Installation Needed Benefits Easy-to-use digital controls let you set the desired temperature.* Maximum spot air conditioning Btu/h provides cool air to just the spot that needs it. Costs as little as 10 cents per hour to run. Operates in high temperature ranges, far beyond what most air conditioners can handle. Performs in the harshest environments, 24 hours a day, seven days a week. Up to a 30-degree drop from ambient temperature, required for effective spot air conditioning. All-in-one design provides for convenient, low maintenance operation. Simply roll it in, plug it in and turn it on! ** * For Classic Plus 14 and Classic Plus 26 models only. ** Exhaust duct required in some applications. The Classic 2002 American Standard Inc. All rights reserved

MovinCool Classic/Classic Plus Series Auto Condensate Removal Why bother with emptying the drain tank when you can install a condensate pump to remove the water automatically? This pump has an 18-ft lift capacity to reach virtually any remote drain. With the condensate pump installed, drainage is automatic and access to the compartment is no longer necessary. A cover plate can then be added to conceal and protect the pump. 9 Cover Plate COV03325 484009-0480 COV03325 484009-0480 COV03325 484009-0480 COV03325 484009-0480 10 Condensate PMP01587 CPK2 PMP01586 CPK1 PMP01588 CPK3 PMP01589 CPK4 Pump Kit Condenser Air Removal To exhaust the warm condenser air above the work area, attach the warm air flange and duct to the top of the unit. When using MovinCool inside an office, simply replace the ceiling tile with the MovinCool ceiling tile and insert the duct to exhaust the warm air. No special tools or equipment are required for the installation. 5 Warm Air Flange FLG01056 481170-0190 FLG01056 481170-0190 FLG01056 481170-0190 FLG01056 481170-0190 6 Warm Air Duct DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-0060 7 Ceiling Tile PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280 Make-Up Air When balanced air flow is required, attach the air plenum with a duct from the side of the unit to an outside air source. The air to the condenser is pulled from outside the room to eliminate problems associated with negative air pressure. 6 Air Duct DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-0060 7 Ceiling Tile PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280 8 Air Plenum KIT07912 LAY84270-0040 KIT07910 LAY84270-0020 KIT07910 LAY84270-0020 KIT07911 LAY84270-0030 Remote Cooling The amount of air supplied to remote areas can be quickly and conveniently increased by attaching 10 ft extension ducts directly over the standard ducts. For more permanent installations, use the flange and clamp to secure the extension ducts to the unit. Each duct can be extended 30 to from the unit, depending on the model. Add trim rings to the end of the extension ducts to give a finished look and keep the ducts from unraveling. The dual duct accessory can be used to divide each 5 in. nozzle opening into two 4 in. outlets to multiply your cooling options. 1 Cold Air Flange FLG01055 481170-0180 FLG01055 481170-0180 FLG01055 481170-0180 FLG01058 481170-0250 2 Extension Duct DUC01044 481744-0090 DUC01044 481744-0090 DUC01044 481744-0090 DUC01041 481744-0030 3 Trim Ring RNG01760 481851-0200 RNG01760 481851-0200 RNG01760 481851-0200 RNG01761 481851-0210 4 Dual Duct DUC01045 484209-0030 DUC01045 484209-0030 DUC01045 484209-0030 N/A N/A Auto Condensate Removal Condenser Air Removal Remote Cooling Make-Up Air

Accessories Part Descriptions for MovingCool Classic/Classic Plus 1 Cold Air Flange 5 in. or 6 in. diameter white metal flange with wire clamp and mounting screws. 2 Cold Air Extension Duct 5 in. or 6 in. diameter white plastic duct that extends from 6 1 2 ft to 10 ft in length. 3Trim Ring 4Dual Duct 5 in. or 6 in. diameter black plastic ring mounts as end caps for extension ducts. 5 in. diameter white plastic flange with two 4 ft nozzles that extend to 3 1 2 ft in length. 5 Warm Air Flange 12 in. diameter gray metal flange with wire clamp and mounting screws. 6Warm Air Duct 12 in. adjustable diameter white plastic duct that extends from 6 1 2 ft to 10 ft in length. 7 Ceiling Tile 24 in. x 24 in. white tile with 12 in. hole for warm air duct. 8Air Plenum White plastic plenum, hinged for filter cleaning. 9Cover Plate Blue metal plate covers condensate collection area. 10 Condensate Pump Kit 110V or 220V pump kit includes 3 8 in. diameter x 20 ft length hose and installation hardware.

Classic & Classic Plus Specs Features Cooling Capacity Electrical Characteristics Fans Evaporator Condenser Compressor R-22 Charge Dimensions Net Weight/Shipping Weight Power Cord Condensate Tank Capacity Operating Conditions Max. Duct Length Max. Sound Level MovinCool PN Trane PN Control Panel Thermostat Control (Btu/h) Rating conditions: 95 F at 60% RH Voltage Requirement Total Power Consumption Current Consumption Recommended Fuse Size NEMA Plug Configuration Min. Max. Voltage Motor Output high/low Fan Type Max. Air Flow high/low Max. External Static Pressure Fan Type Max. Air flow high/low Max. External Static Pressure Type Output W x D x H Gauge Length Min. Max. (@ 50% RH) Per Cold Duct Hose Hot Duct Hose With Condenser Duct high/low Without Condenser Duct high/low Classic 10 UNT00863 10,000 Btu/h 1 Phase,115V 1.1 kw 10.6 amps 15 amps 5 15 104 126 0.14 kw 270 CFM 0.33 IWG 740 CFM 0.13 IWG Hermetic Rotary 0.6 kw 1.15 lb 19 x 26 x 41 in 145/170 lb 14 AWG (3-core) 6 ft 68 105 F 40 ft 55 db 58 db Classic 18 UNT00864 18,000 Btu/h 1 Phase, 208/230V 2.1 kw 10.8/10.0 amps 15 amps 6 15 187 253 0.35 kw 530 CFM 0.52 IWG 1180 CFM 0.25 IWG Hermetic Rotary 1.1 kw 1.59 lb 19 x 26 x 41 in 167/200 lb 14 AWG (3-core) 6 ft 68 105 F 50 ft 63 db 67 db Classic Plus 14 UNT00861 14,000 Btu/h 1 Phase,115V 1.3 kw 12.3 amps 15 amps 5 15 104 126 0.24/0.19 kw 440/380 CFM 0.31 IWG 880/760 CFM 0.19 IWG Hermetic Rotary 0.8 kw 1.5 lb 19 x 26 x 41 in 153/195 lb 14 AWG (3-core) 10 ft 70 115 F 30 ft 57/55 db 60/58 db Classic Plus 26 UNT00862 26,000 Btu/h 1 Phase, 208/230V 3.1 kw 15.6/14.0 amps 20 amps L6 20 187 253 0.55/0.38 kw 708/600 CFM 0.54 IWG 1680/1460 CFM 0.25 IWG Hermetic Scroll 1.6 kw 1.87 lb 19 x 29 x 47 in 235/265 lb 12 AWG (3 core) 6 ft 70 115 F 45 ft 66/64 db 69/67 db All specifications subject to change without notice. Standard warranty includes 12 months on entire unit. All models are UL listed and feature compressor overload relay and fan motor protection. All models also feature compressor short-cycle protection, return air thermostat, automatic restart and accommodate a condensate pump kit. All models are 50 Hertz (Hz) compatible with a slight performance decrease from specifications listed above. DENSO SALES CALIFORNIA, INC. REGISTERED TO ISO 9002 FILE NO. A5537 2002 DENSO SALES CALIFORNIA, INC. MovinCool is a registered trademark of DENSO Corporation.

The Trane Company An American Standard Company www.trane.com For more information contact your local district office or e-mail us at comfort@trane.com Literature Order Number Date Supersedes Stocking Location February 2002 New La Crosse Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.