A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

Similar documents
Guide to the use of Smoke Seals in Doorsets

Practice Guidee No.1. of the

THE HOME OF REACTIVE PROTECTION SYSTEMS

Regulatory Reform (Fire Safety) Order 2005

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

Agrément Certificate 92/2841 website: Product Sheet 1

Regulatory Reform (Fire Safety) Order 2005

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

FIRE DOORS RHUL REQUIREMENTS

Cl/SfB (32.5) Xt7 (K2) Acoustic, Smoke and Fire Seals for Door Assemblies

Maintenance. Why Maintain Fire Doors? Regulations

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

Fire Door Maintenance Guide.

IDD 033C - Fire door sets

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

CERTIFICATE OF APPROVAL No CF 5179 LORIENT POLYPRODUCTS LIMITED

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

Code of Practice: Hardware for Fire and Escape Doors

The Association for Specialist Fire Protection

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK

Panic and Emergency Exit Devices

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

The Association for Specialist Fire Protection

Hardware for Sliding Doors & Folding Doors

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

C/S Fire Rated Door Edge Protection Product Range FD60

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

Code of Practice: Hardware for Fire and Escape Doors. Issue No.2 June 2006 THE GUILD OF ARCHITECTURAL IRONMONGERS

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

Intumescent Fire Dampers

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

MULTIKWIK SEWER SYSTEMS MULTIKWIK WC PAN CONNECTORS

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

CERTIFICATE OF APPROVAL No CF 5527 TALLERES DE ESCORIAZA S.A.U.

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS

Fire doors are a lifeline. When properly fitted and properly cared for they give vital minutes for people to safely escape from fire and smoke.

A GUIDE FOR SELECTING FLAT ENTRANCE DOORSETS. A publication for housing associations, landlords, building owners and local authorities in England

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

dhf General Information Automated Gates Guidance for enforcement bodies

Controlled Door Closing Devices

CERTIFICATE OF APPROVAL No CF 418 PROMAT UK LTD

Product Data Sheet. Astro Strip

Consumer unit replacement in domestic and similar premises

The Passive Fire Protection Handbook

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

FIREPRO SoftSeal System

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

FIRE DOOR SAFETY. Important information for leaseholders about fire doors in your property. September 2017 Version 1

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Fire Protection. Intumescent fire and smoke seals for door assemblies

Guidance Note No 19/1. CE Marking windows and doorsets

CERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.

CI/SfB (32.5) Ro8 (K2) ACOUSTIC SEALING SYSTEMS FOR DOOR ASSEMBLIES

Specifying Security Hardware for Doors

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

CERTIFICATE OF APPROVAL No CF 136

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Loss Prevention Standards

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Fire doors guidance. Provided by

The Passive Fire Protection Handbook

Specification, installation & maintenance of fire doors: Technical Note 2

Cl/SfB (32.5) Ro8 (K2) Specialised Fire Resistant Door Hardware

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Easy-action Door Closer DORMA TS83

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Transcription:

Information Sheet No. 5 Intumescent Fire Seals Association A Guide to the Selection of Smoke Seals for Doorsets THE HOME OF REACTIVE PROTECTION SYSTEMS

CONTENTS Page Introduction 1 Purpose of smoke seals 1 The fitting of smoke seals 1 General guidance 2 Durability 2 Specific guidance on generic types of smoke seals 3 Conclusions 3 Bibliography 3 1. SEALS FOR FITTING TO HEAD AND JAMBS OF DOORSET 4 Type A: Door edge/frame reveal fitted seals 4 Type B: Stop mounted seals fitted to outer, visible face 5 Type C: Stop mounted seals fitted to inner, non visible face 6 Type D: Corner reveal mounted seals fitted to inner face 7 2. SEALS FOR USE ON DOUBLE LEAF DOORS 8 3. SEALS FOR USE AT THRESHOLDS 9 Information about IFSA 10 ACKNOWLEDGEMENT Some of the information in this document was prepared by International Fire Consultants Ltd. for English Heritage who have kindly given permission for it to be included here.

GUIDE TO THE SELECTION OF SMOKE SEALS FOR DOORSETS INTRODUCTION IFSA Information Sheet No. 3 'Guide to the Use of Smoke Seals in Doorsets' was the first data sheet to explain the technology behind the use of smoke seals on fire resisting door assemblies. Whilst it presented a list of factors to take into account when specifying seals, it did not make recommendations as to which type of seal, e.g. compression or wiping, blade or brush, was most suited to the application under consideration. The intumescent sealing industry has now developed a wide variety of doorset smoke seals in response to the demand from both the construction industry and building users for products which will perform in different situations. This information sheet lists the merits and application suitability of the main generic types currently available. This Information Sheet has been prepared in order to assist with the selection of smoke seals for the purpose of improving the leakage rate of existing doors to satisfy the regulatory recommended rate of 3m³/m/hr @ 25Pa when tested in accordance with BS476: Part 31.1. Whilst, some of the guidance given in respect of Type A seals may be applicable to combined smoke and intumescent seals, as may be fitted to new doors or used in the refurbishment fire doors that have not previously been fitted with intumescent sealing systems, it is primarily aimed at separate stand alone smoke seals. reveals that the majority of the fire resisting doors within a building are also required to have a smoke control function, against predetermined performance requirements, which has to be verified by test. An analysis of the use and distribution of smoke control doors shows that they are recommended for the protection routes required for providing means of escape in the event of a fire. Currently, for practical reasons, only seals that restrict the spread of cold smoke are specified. The purpose of smoke seals is to limit, but not totally eliminate, the movement of cold smoke from one compartment or space to another. Cold smoke seals are not generally able to prevent the passage of higher temperature smoke which may cause some cold smoke seals to melt. However, at higher temperatures the intumescent seals activate to limit, but not eliminate the movement of hot smoke. Smoke seal description A fire only sealing system usually consists of an outer casing (PVC rigid, Aluminium casing) used to protect the intumescent core, such sealing systems are usually provided with a high performance self adhesive system for installation with a rebate either in the door leaf and or door framing section. The smoke seal is differs from its fire only seal by the addition or incorporation of smoke sealing elements. The typical smoke sealing system may include brush and or a series of integral fins, which are essentially thermo fused on the rigid casing or positioned within a retaining grove with the fire seal component. When selecting combined intumescent and smoke seals then the manufacturers' recommendations in respect of fitting, including the total length of permitted interruptions, shall be followed explicitly. As it is not possible to illustrate all the variations of generic types, IFSA Members should be consulted for advice on the most suitable seal to suite specific circumstances. PURPOSE OF SMOKE SEALS Smoke poses a greater threat to life safety than fire itself and it is for this reason that smoke seals are recommended for the protection of escape routes in the various guidance documents which support UK regulations. Principally, in the UK, these are Approved Document B to the England & Wales Regulations and of the Building Standards Scotland Regulations, based upon the recommendations given in the appropriate part of BS9999:2008. For example, a study of these documents INSTALLATION OF SMOKE SYSTEMS SEALING The recommended acceptable smoke leakage performance of a smoke control doorset is given in Approved Document B to the England & Wales Building Regulations and also in the relevant parts of BS5588. There are differences between the two recommendations 1

but both are deemed to be equally satisfactory to demonstrate compliance with the regulations. While each recommendation requires the testing of a doorset in accordance with BS476: Part 31.1, there is a divergence in requirements at the threshold. Approved Document B, for example, allows performance to be evaluated without any reference to smoke transfer which may result from the threshold gap. BS9999 calls for the threshold performance to be separately considered and provides three options with varying degrees of effectiveness. More recent research by IFSA Members shows that it is vitally important to incorporate a smoke seal of known performance at the threshold and failure to do so can completely negate the beneficial contribution of seals around the rest of the door assembly. Examples of appropriate perimeter and threshold sealing systems are illustrated and reviewed on the later pages of this Information Sheet. In practice, the fitting of a stop has little effect on the performance of a seal because the door normally does not make contact over the whole of the stop surface. The test method does not specify whether the stop is a good fit or not and the test results may be better than achieved in practice because of a particularly well fitting stop. The meeting stiles of pairs of doors are not subject t this uncertainty because no top is involved. Manufacturers' advice should always be taken on the installation and compatibility of sealing systems. GENERAL GUIDANCE There is no perfect seal which accommodates all the requirements. All seals have some good features and some disadvantages which make them more suited to some applications and less to others. The following general issues are important when choosing the most suitable product for specific applications: Smoke leakage performance when tested to BS476: Part 31.1 The supplier of the smoke seal should provide test evidence to this standard to demonstrate that the seal has been incorporated in a test on a fire door assembly where the leaf has similar physical characteristics, e.g. thickness, weight, construction and stiffness as the leaf in the assembly to which it is to be fitted. It is important to check that the smoke seal was tested on an assembly of the same configuration as the intended use and, in particular, that the perimeter gaps were representative. plane within the thickness of the door because gaps at the corners allow significant leakage. As a door contacts the seals the mode of operation depends on the position of the seal in the frame or door edge. Figure 1 shows that when the seals are fitted in one plane, or the reasons just explained, the deformation is different at the closing jamb from that at the hanging jamb. Seals which are particularly good in a wiping mode may not be so good in a compression mode and vice versa. Various types of seal have been developed in an effort to cope with these differing requirements and provide effective sealing. Conventional seals should be fitted in a plane either contacting the outer face of the door or parallel to this 2

DURABILITY It is important that smoke control doors that are in constant use are fitted with seals that are able to withstand the daily cycling for a reasonable period without damage. Cyclic endurance testing does not form part of the BS476: Part 31.1 test procedure, but is included in the Performance Assessment laid down by the CERTIFIRE accreditation scheme TS25. The schedule calls for the seal to withstand 100,000 open/shut cycles as part of a door assembly which has to satisfy the leakage criteria specified in TS25, both before and after the cyclic testing. Ability to accommodate variable gaps between the door edge and frame and distortion of the door leaf This is most important in retrofit situations when buildings are being upgraded as existing doors tend to be less well fitting. Frequently the gaps vary significantly around the door edge and the door is warped to some degree. Some seals are able to accommodate variations in fit more than others and this is noted in the recommendations that follow. These problems are more easily controlled when supplying new doorsets which are factory assembled. However, even new doors can shrink after installation due to loss of moisture and, hence, the doorleaf to frame gap can increase, with consequent effects on the seal fit. Effects of the door's ability to self close Where the building design prevents the movement of air, for example, due to sealed windows or small unventilated lobbies, then smoke seals can make it more difficult to open and close a door. Similarly, seals offer varying degrees of friction or closing resistance. Both of these issues are taken into account in the specification recommendations given in Information Sheet No. 3. Certain generic types of seal do have a greater effect on closing than others and this is highlighted in the recommendations. 2 Strict limits on the opening and closing resistance are specified as part of the performance requirements which need to be satisfied as part of the CERTIFIRE accreditation. Type A seals are more prone to friction, dependent upon the fit. smoke leakage. Interruptions by hinges and other ironmongery can significantly affect the performance of a seal. Those seals which can meet the requirements, even with multiple interruptions, will tend to make the door assembly harder to operate in everyday service because it is more important to ensure maximum compression or deflection of the seal in this case. Some generic types of seal do not require interruptions which generally make it easier for these to meet the recommended leakage rate. This is taken into account in the comments. SPECIFIC GUIDANCE ON GENERIC TYPES OF SMOKE SEALS The guidance given on the following pages is only intended to be general in its nature because variations exist between products of the same generic type. Information on smoke leakage performance is not given and, therefore, evidence of performance needs to be obtained from the supplier before specifying the selected type. CONCLUSIONS It can be seen that there is no universal smoke seal which is perfect for all applications. Seals which are good on the leading edge of the door are sometimes far less suitable at the heel of a door leaf where wiping seals are frequently used in compression. As a consequence, the specifier must consider what aspects are important for the intended use, but the guidance given in the Information Sheet should at least help in making the decision intelligently and in full knowledge of the issues. BIBLOGRAPHY BS476: Part 31.1: 1983 BS5588: various parts England & Wales Building Regulations: Approved Document B Building Standards Scotland Regulations: CERTIFIRE Performance Assessment Schedule: P021 The contribution of edge seals to the control of smoke leakage via door assemblies. Interruption by items of ironmongery Care must be taken to ensure that selected smoke seals can achieve the performance criteria recommended in codes and guides to regulations, of 3m³/m/hr maximum 3

1. SEALS FOR FITTING TO HEAD AND JAMBS OF DOORSET TYPE A: DOOR EDGE/FRAME REVEAL FITTED SEALS These seals operate in a wiping mode which means that there is a significant resistance to opening and closing unless the door to frame gap is accurately controlled and does not vary significantly around the perimeter of the door. Very tight gaps may cause damage to the seal and hinder closing. They are able to tolerate warping of the door in use and during a fire test. If the seals are part of a combined intumescent fire and smoke seal they will be interrupted by ironmongery and are not likely to meet the current maximum leakage rate of 3m³/m/hr @ 25 Pa unless there is test evidence in accordance with BS476: Part 31.1 which shows compliance. If the smoke seal is not combined with an intumescent seal, it can be set away from the leaf centre line thereby avoiding ironmongery.. 4

TYPE B: STOP MOUNTED SEALS FITTED TO OUTER VISIBLE FACE Ideal for fitting on existing doors because the door does not have to be removed but the product is normally visible. Can tolerate large variations in gap width because of its surface position. Gaps between the door face and the stop can be accommodated during fitting. More prone to damage by trolleys or other traffic. Not very invasive when used on historical doors, but is normally fairly conspicuous. The smoke seal is less prone to causing problems associated with self closing of the door leaf. This type of smoke seal is rarely interrupted by items of ironmongery. 5

TYPE C: STOP MOUNTED SEALS FITTED TO INNER, NON VISIBLE FACE The seal is not conspicuous and is suitable for historic or aesthetically sensitive doors. Can accommodate large door edge to frame gaps but has limited ability to cope with door distortion. If the door is an existing good fit on the stops it will have to be re hung or the stops refitted if planted. This type of seal is normally uninterrupted by items of ironmongery. 6

TYPE D: CORNER REVEAL MOUNTED SEALS FITTED TO INNER FACE The durability of this seal type is dependent on the quality and performance of the bond between the seal and the frame. This can be influenced by preparation of the surfaces. Non invasive and suitable for historic doors. Rarely interrupted by items of ironmongery. May not be possible to fit to a door with a tight door edge to frame gap without refitting door. 7

2. SEALS FOR USE ON DOUBLE LEAF DOORS The seal fitted to the meeting stiles of a pair of doors has to be Type A (i.e. wiping) and, therefore, the other seals fitted to the head and the hanging or pivoting stiles have to be of the same type. Pairs of doors are difficult to seal satisfactorily, so it is essential to consult manufacturer's literature to ensure good performance. In particular, the seals are not very tolerant of door edge to frame gap with variations. Where locks or flush bolts are fitted, the seal is likely to be interrupted making it difficult to achieve the required performance. It is not usually possible to mix stop mounted seals with wiping seals on these types of doors. Many pairs of doors have curved door edges to allow easy opening and special seals with curved faces have been developed for these applications. Note that blades or brushes should never be put into both edges simultaneously. The smoke seal may face an intumescent seal in the opposite door edge, dependent upon manufacturer's instructions. 8

3. SEALS FOR USE AT THRESHOLDS To be truly effective the line of the seal should line up with the seals fitted to door head and stiles. To achieve good performance, it is necessary to pay attention to the joint between the stile seal and the threshold seal. 9

INFORMATION ABOUT IFSA The Intumescent Fire Seals Association (IFSA) is a trade association established in 1982 with the following objectives: To promote the life safety benefit associated with the use of intumescent and smoke seals To promote research and development into extending the areas where these benefits can be utilised To participate in the development of test procedures for fire protection products in BSI, CEN and ISO which are fair, repeatable and reproducible. IFSA maintains close links with the fire community. The Secretariat is based at International Fire Consultants and receives technical advice from its Principal Consultant, Peter Jackman. At the time of its formation, IFSA recognised the need for a simple standard test to compare the performance of intumescent fire seals for use in fire doorsets, which was free from the influence of other materials and constructional variations and yet subjected the intumescent material to the conditions which prevail in a full scale test. It, therefore, sponsored the development of such a test and this is now embodied in BS476: Part 23 (1987). Whilst the results of the test have a limited field of application, only being usable on single leaf, single action, latched doors of limited size and distortion characteristics, it does allow the sealing capability of intumescent seals to be compared without any influence from the leaf. application of intumescent sealants due to be published in 2010. Fire stopping, service penetration sealing, fire doors and fire glass are all critical aspects of fire safe premises and under the new Regulatory Reform (Fire Safety) Order and the ongoing reliance on fire risk assessments, it is vital that risk assessors understand the role and function of these products. IFSA has produced a number of downloadable guides (Good Practice Guides) to help risk assessors know and understand when a particular intumescent application is right or wrong, or how a risk may be controlled by the use of the correctly specified sealing product. These guides were commended by the ABE in the 2006 Fire Safety Award competition. The move away from brickwork, blockwork and cast concrete forms of construction, towards a greater use of studwork and joisted walls, floors and ceilings, has left many of our fire separating constructions compromised by the fitting of electrical services (switches, plug sockets, concealed lighting, extract fans). IFSA has co operated with the Electrical Safety Council (ESC), in the preparation of their guide, 'Electrical installations and their impact on the fire performance of buildings; Part 1, Domestic Premises'. This did win the ABE's Fire Safety Award in 2009. Intumescent materials can seriously reduce the impact that such installations may produce. Correctly fitted sealing systems make a greater contribution to life safety in a fire than almost any other measure. If you do nothing else to enhance life safety at least seal up the building with fire and smoke seals, preferably from an IFSA Member because they take fire safety seriously. There is now an ISO equivalent test, i.e. BS ISO 12472: 2003. Due to its repeatability the test method is being used successfully to evaluate the influence that real time ageing may have on the properties of intumescent fire seals produced by IFSA member companies. The programme is planned to investigate 25 years exposure to a variety of controlled and uncontrolled environments. Early findings showed no detectable visual decline and tests are being undertaken soon to confirm these findings. A test programme undertaken in conjunction initially with DOE/BRE to produce standardise conditions for evaluating penetration seals formed the basis of the standard configuration incorporated in the CEN test procedure EN 1366 3 for evaluating seals for use with metal pipes. This configuration has been refined and now forms a draft technical report in ISO (DTR 10295 3) where a method of extrapolating the results of penetration sealing tests, using simple solid conductors, can be used to establish the field of 10

CURRENT IFSA MEMBERS AND CONTRIBUTORS TO THE INFORMATION SHEET TECHNICAL CONSULTANTS TO IFSA Intumescent Fire Seals Association 20 Park Street Princes Risborough Buckinghamshire HP27 9AH Tel: +44 (0)1844 276928 Fax: +44 (0)1844 274002 Web: www.ifsa.org.uk Email: contactus@ifsa.org.uk