Environmental Specifications for Kaleidescape Components Engineering Bulletin

Similar documents
Vertical Mounting of Kaleidescape Components

Section 1. Overview. The Kaleidescape Premiere System. System Components

COMBUSTION AIR SYSTEM

WHITE PAPER.

Mounting 4000 and Appliances with Telescoping Rails

Service Parts for RMR Wall-Mount Enclosures

Model GIT 4 Gutter Snow and Ice Melting Control

Kaleidescape Programming Manual for Elan Home Systems

it s unrivaled in its role as a housewide entertainment machine. Sound & Vision Magazine

INSTALLATION INSTRUCTIONS

Reclaim precious cabinet and shelf space throughout your home. Image courtesy of and Genesis Audio & Video, Irvine, CA.

WM-4510HZD Installation Instructions

Cooling the mid-size enclosure

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Checklist For Building Inspection & Fire Safety

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

I can do WHAT? A look into Compass Viewers

Surna Dehumidifier Operating & Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual


PRE-INSTALLATION GUIDE

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Work In Shirt-Sleeve Comfort When It s Doggone Cold

GAS APPLIANCE LISTING PROGRAM

PRE-INSTALLATION GUIDE

STERO SD3. Door-Type Dishwasher MODEL: ML

T F E

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

Ruud Achiever Plus Series Multi-position Gas Furnaces

User Manual. Model: FSL200 Laser Fume Extractor

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Ruud Achiever Series Multi position Gas Furnaces

XRRS Specification Fire Ready Hood

SYNRAD Technical Bulletin # 0015d

COMBUSTION AIR SYSTEM Model: CAS-3

Welcome to. Central Vacuum - Products Overview

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Z-PACK TinMan 85 ohm Connector Overview

Maestro 400 series ice machine Use/ application. top mount. with ice storage bin RIDE. with Follett Vision dispenser RIDE.

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

RCTA Horizontal Evaporator Coil Installation Instructions

Use/ application. top mount. with ice storage bin RIDE. with Follett Vision dispenser RIDE. with. ice and

IN020 Rev F Page 1 of 8

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

GateKeeper Gas Purification System Z2 Series for 400, 500, 600 NM 3 /HR

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Multi-Position Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )


Site Specifications for the. INDUSTREX M37 Plus NDT Filmprocessor

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Installation and Maintenance Manual IM 1102

Operator s Manual. IP-100 Immersion Probe Cooler

40E ELECTRIC FAN HEATER

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

Properly designed economical engineering controls reduce chemical migration outside the spray area reduce re-occupancy time to less than 24 hours

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

PRE-INSTALLATION GUIDE for MODELS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Site Requirements ADVANTAGE PLUS

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

PRE-INSTALLATION GUIDE for MODELS

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

APC APPLICATION NOTE #109

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Rheem Classic Series Multi-position Gas Furnaces

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

T-Series Air Conditioner T53 Model

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

T-Series Air Conditioner T20 Model

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Chilled Filtered Boiling. Quench your thirst for smarter design

T-Series Air Conditioner T15 Model

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Open-area Smoke Imaging Detector. Engineering Specification

FT1000 FLIGHT-TYPE DISHWASHER

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

HS Series Installation & Operating Instructions RadonAway

Air Dryer Application Guidelines

Installation Instructions Remote Blowers

OPERATING MANUAL 12 AXIAL FANS

Section 5. Control Systems

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Transcription:

Environmental Specifications for Kaleidescape s Engineering Bulletin Temperature This document provides environmental specifications and guidance for designing proper cooling for Kaleidescape component installations. For more best practices in designing rack enclosure cooling for A/V components, refer to the white paper, A/V Installation Cooling. The maximum air intake temperature for Kaleidescape components is specified in the table below. Note that if a system is installed in a rack enclosure, and the system includes Strato/Alto/Terra, then the maximum air intake temperature for the rack enclosure is. The minimum air intake temperature for all Kaleidescape components is 41 F (5 C). Measure ambient air temperature within 1in. (2.5cm) of the front of the component, and at any rack enclosure air intake vents. Maximum air intake temperature Strato Movie Player (K0509, K0510) Alto Movie Player (K0507, K0508) Terra Movie Server (K0108) Disc Vault (KVAULT DV700, KVAULT-M700) This document is for informational purposes only. Kaleidescape makes no representations or warranties, express or implied, regarding the accuracy or completeness of the information contained herein and Kaleidescape shall have no obligation to provide updates to this information in the future. Copyright 2009 2016 Kaleidescape, Inc. All rights reserved. Kaleidescape and the Kaleidescape logo are trademarks of Kaleidescape, Inc. and are registered in the United States and certain other jurisdictions. Other trademarks and trade names are owned by third parties and may be registered in some jurisdictions. Kaleidescape Part No. 101-0097-00 Rev 10.

Maximum air intake temperature Legacy s Movie Player (KPLAYER-2000, KPLAYER-2500) Speed Reader (KSPEEDREADER, KSPEEDREADER-2) Some Kaleidescape components can be installed in a vertical orientation, and the maximum intake air temperature decreases for some components when mounted vertically. Refer to the Engineering Bulletin, Vertical Mounting of Kaleidescape s. The storage temperature range for all Kaleidescape components is 4 F to 140 C (-20 C to 60 C). Relative Humidity The operating relative humidity range (non-condensing) for all Kaleidescape components is 20% to 80%; the range is 5% to 90% for storage. Maximum Operating Altitude All Kaleidescape components have a maximum operating altitude of 10,000ft (3000m). Heat Output The table below specifies maximum heat output for Kaleidescape components. These specifications can be used in combination with the room temperature to Kaleidescape Part No. 101-0097-00 Rev 10 Page 2 of 5

calculate the required airflow. See the section Calculating Rack Airflow in the white paper, A/V Installation Cooling. Maximum heat output Strato Movie Player with 6TB internal storage (K0509-0006) without storage (K0510-0000) Alto Movie Player with 6TB internal storage (K0507-0006) without storage (K0508-0000) Terra Movie Server with 12TB (K0108-0012) with 24TB (K0108-0024) 80 BTU/hr (23W) 71 BTU/hr (21W) 153 BTU/hr (45W) 132 BTU/hr (39W) 140 BTU/hr (41W) 243 BTU/hr (71W) 180 BTU/hr (52W) 4TB Disk Cartridges 6TB Disk Cartridges Disc Vault (KVAULT DV700, KVAULT-M700) 446 BTU/hr (131W) 300 BTU/hr (88W) 143 BTU/hr (42W) 96 BTU/hr (28W) 180 BTU/hr (52W) Legacy s 4TB Disk Cartridges 6TB Disk Cartridges Modular Disc Vault (KVAULT-10) Movie Player (KPLAYER-2000, KPLAYER-2500) Speed Reader (KSPEEDREADER-2) Speed Reader (KSPEEDREADER) 150 BTU/hr (45W) 858 BTU/hr (251W) 831 BTU/hr (243W) 853 BTU/hr (250W) 310 BTU/hr (90W) 44 BTU/hr (13W) 150 BTU/hr (45W) 100 BTU/hr (30W) 89 BTU/hr (26W) 75 BTU/hr (22W) 68 BTU/hr (20W) 358 BTU/hr (105W) 375 BTU/hr (110W) 96 BTU/hr (28W) Kaleidescape Part No. 101-0097-00 Rev 10 Page 3 of 5

Airflow The table below specifies maximum airflow generated by internal fans in Kaleidescape components. An installation enclosure must allow the specified airflow to easily escape the enclosure through the enclosure s exhaust fans or external vents. Use the airflow in the table to determine the minimum exhaust airflow capacity in an installation enclosure. Airflow Strato Movie Player (K0509, K0510) Alto Movie Player (K0507, K0508) Terra Movie Server (K0108) 20 CFM (34m³/hr) 7 CFM (12m³/hr) Disc Vault (KVAULT-DV700, KVAULT-M700) 7 CFM (12m³/hr) 6CFM (10m³/hr) 7CFM (12m³/hr) Legacy s Movie Player (KPLAYER-2000, KPLAYER-2500) Speed Reader (KSPEEDREADER-2) Speed Reader (KSPEEDREADER) 40 CFM (68m³/hr) 30 CFM (50m³/hr) 15 CFM (26m³/hr) 5 CFM (8m³/hr) 6 CFM (10m³/hr) 45 CFM (77m³/hr) 6.2 CFM (11m³/hr) Ventilation Use the following guidelines when installing Kaleidescape components to ensure proper ventilation. Verify proper clearance for ventilation. The rack or other enclosure doors must not reduce the air space around the component below the specified clearance. Kaleidescape Part No. 101-0097-00 Rev 10 Page 4 of 5

Maintain 2in. (5cm) clearance in back. Maintain 1in. (2.5cm) clearance in front and on sides. Maintain proper airflow path for ventilation. Verify adequate cool air intake at front and bottom of component. Verify hot air exhaust at back and top of component. Verify intake and exhaust vents are not obstructed by dust or particles. The component front panel filters and traps coarse dust and particles. Exhaust vents also accumulate dust. Vents clogged with dust can lead to temperature increase and possible damage. If the component is not installed in an enclosure, the front panel and rear vents should be inspected every 4 months and cleaned if necessary to provide adequate airflow. Refer to the Engineering Bulletins, Server Cleaning Procedures and Player Cleaning Procedures, for detailed cleaning instructions. Do not operate the component in a dusty environment. In case of sanding or other temporary dust source, turn off the component until the dust source is removed. If the internal surfaces of a component become coated with dust, the component will require servicing by Kaleidescape. The figure below shows proper ventilation and airflow for components in a rack enclosure. The rack enclosure has a cool air intake at the bottom front and a hot air exhaust at the top. Hot air exhaust at top 1in. (2.5cm) minimum clearance in front and sides 2in. (5cm) minimum clearance in back Cool air intake at front bottom Kaleidescape Part No. 101-0097-00 Rev 10 Page 5 of 5