EZ Bleed Solenoid Installation & Troubleshooting Guide

Similar documents
DV & DVF VALVES 075-DV: ¾" (20/27) 100-DV: 1" (26/34) 100-DV-SS: 1" (26/34) 100-DV-MM: 1" (26/34)

Installation, Operation and Maintenance Instructions

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

R89-CB 808-CB Series. Serie R89-CB 808-CB Série R89-CB 808-CB. Tub & Shower Shower Only Trim Kit

808 Series. Serie 808 Série 808

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Battery Powered Actuator with Watering Timer RBC MVA

Installation Instructions EFS Hand Washing Station

FIREPLACE INSTALLATION

ENCLOSED UNIT TECHNICAL MANUAL Items # &

INSTALLATION INSTRUCTIONS

Audi-Larm Audible Alarm

CORALAIS BODYSPA BATH AND SHOWER FAUCET

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

LC Series - Light Commercial Pump Station Installation and Operation Manual

Refrigerator. Installation Guide. Free Standing Appliance

SuperKlean Washdown Products

V SERIES HDR GAS RANGES

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

How to Fix a Leaky Toilet:

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Stainless Steel Pump to dispense portions up to 2oz MODELS INCLUDE:

Contact Davies Pros On Controls For Proper Application. Solenoid Valves

IWATA STUDIO SERIES MAXX JET AIR COMPRESSOR IS-1000

INDEX. Granita Machine. Operation a nd Instruction Manual

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Stainless Steel Pump for use with food containers

MINIMED 670G SYSTEM CHANGING THE MINIMED MIO INFUSION SET QUICK REFERENCE GUIDE

HE360 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit

MINIMED 670G SYSTEM CHANGING THE MINIMED SILHOUETTE INFUSION SET QUICK REFERENCE GUIDE

Table of Contents. What to Expect with. Mounting Options. Tools Needed

TUB AND SHOWER FAUCET

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

INSTALLATION. Glass Panel Doors (select models) CAUTION

Stainless Steel Pump. Thank You MODELS INCLUDE: CP-200 CP-F FP FP-V FP-200 FP-200V FP-1½ FP-DI FPV-DI TP-V TP-200V

R Series. Serie R Série R Tub & Shower Shower Only Trim Kit

English, French & Spanish No Color

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

TK-1001, 1101, 1201, 1301, 1601

F AN-ASPIRATED RADIATION SHIELD

Decorative Low Profile Integrated Kit

*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

Installation Instructions

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

Ambient light powered, smart irrigation controller ECO1 MVA ECO1 ASV.075

MIX Boiler & Font Range Service Manual

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

Water Distiller Service Manual

Autocirc Instant Hot Water Pump Model: ACT E10 INSTRUCTION MANUAL REVISION A

Simple to Set Timer (SST) Frequently Asked Questions

Installation and Operation Manual

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Basin Set INSTALLATION INSTRUCTIONS

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

HE120, HE160 Humidifier Installation Kit

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

Battery-Powered Controller with Inline Valve

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

PWC-500/1000/1010/1500

MINIMED 670G SYSTEM CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDE

F AN-ASPIRATED RADIATION SHIELD

Installation. Leveling

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers

Room Air Conditioner Service and Parts Manual

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

Wiring Instructions. High-Capacity Steam Humidifiers

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Oil burners fuel unit with solenoid valve

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

3/4 HP Model Trimmer Operating Instructions

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter

Oil burners fuel unit with solenoid valve

Installation & Operating Guide

Mopit 4 Operator s / Service Manual

THERMOSTAT RETROFIT INSTRUCTIONS

Manual Examination Table

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

Installation Manual. Models 99168, 99169, 99170

Orbit ArizonaMist. Installation ra

Battery Powered In-line Valve with Watering Timer RBC 7000

Pulldown Kitchen Faucet

Owner s Guide and Installation Manual

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

Transcription:

EZ Bleed Solenoid Installation & Troubleshooting Guide

English EZ Bleed Solenoid Thank you for purchasing a Rain Bird EZ Bleed solenoid. This solenoid assembly is compatible with the following Rain Bird valves: PG, PEB, PESB, GB and EFB-CP. To use this guide, fold out the back page for visual reference then turn to the appropriate language. Follow the alphanumeric references for installation, adjustment, troubleshooting and replacement parts. Specifications can be found on the back of the foldout page. Note: This solenoid assembly is no longer compatible with the 300BPE or 300BPES series valve. You must use part number B31800, which has a more durable, green solenoid. Installation Refer to F1. 1. WRNING: Turn off water supply and disconnect all electrical power sources. 2. Pull the solenoid handle upward to unlock vertical tabs. B 3. Turn the solenoid handle counterclockwise to remove the EZ Bleed solenoid. D This may require repositioning the handle several times to avoid contact with the handle stop. G 4. If desired, use an open-ended wrench to counter-clockwise remove the solenoid adapter. E Clockwise replace solenoid adapter into valve Troubleshooting Valve will not open. 1. Ensure main water supply is on. Ensure upstream valves are open. Ensure flow control stem is not closed. 2. If valve only opens with manual bleed, ensure controller is programmed to activate the proper zone valve. Test controller power output and service if necessary. Test solenoid power input. a) If controller and solenoid power are detected, insert a thin flat screwdriver into the slotted areas of the solenoid bottom and brown solenoid retainer. Gently pry to disengage retainer. Remove plunger assembly and clean debris. bonnet F ensuring the o-ring does not become pinched or damaged. 5. Clockwise thread replacement EZ Bleed solenoid D into the solenoid adapter. E 6. Use the solenoid handle to clockwise tighten the solenoid. D Push down the handle to lock in place. 7. Connect one solenoid wire C to the controller common wire and the other solenoid wire to the controller power wire. Tighten and protect using only approved watertight connectors. Replace plunger ensuring black surface faces outward. Snap retainer into place ensuring the larger hole faces outward. Persistent problem may be an obstruction lodged in main pipe. b) If power is detected at the controller and not the solenoid, inspect and repair damaged lead wires. Valve will not close. 1. Ensure controller is not operating the valve automatically. Ensure manual internal bleed is off by clockwise tightening the solenoid adapter. Ensure manual external bleed is off by clockwise tightening the valve bleed screw.

Troubleshooting (cont.) 2. Turn off water supply and swap solenoid from an operational valve; replace solenoid if necessary. 3. Turn off water supply and verify that the solenoid adapter o-ring is not damaged; replace if necessary. Check for debris in solenoid bowl preventing plunger from creating a positive seal. 4. Check overall system water-pressure requirements and ensure that multiple zone valves are not operating simultaneously. Disallowing one zone valve to close before another opens can reduce the amount of backpressure needed to close the diaphragm. 5. Turn off water supply and remove bonnet for possible debris or damage causing the diaphragm to stick open. Leakage. 1. Disassemble parts and inspect o-rings/sealing surfaces for damage. Check replacement parts exploded view for missing or replacement parts. ccessories or persistent problems. 1. Refer to the appropriate installation and operation manual for specific troubleshooting procedures 2. Inside the US, please call the Rain Bird Spec Hotline at (800) 458-3005. 3. Outside the US, please refer to the back page for contact information. 4. lways visit us at www.rainbird.com. Notes Replacement Parts Refer to F2. EZ Bleed Solenoid ssembly...209532-02 1. Handle...209943 2. Plunger assembly...210463 3. Plunger...629417 4. dapter assembly...231986. O-ring kit, white retainer...210463 O-ring kit, brown retainer...232038

C D B E 1 F G F1 2 3 4 F2 Electrical Specifications Power: 24 VC 50/60 cycle solenoid Inrush current: 0.41 (9.84 V) at 60 Hz Holding current: 0.23 (5.52 V) at 60 Hz Coil resistance: 24 Ohms, nominal

Rain Bird Sales, Inc. 970 West Sierra Madre venue zusa, C 91702 US Phone: (626) 963-9311 Fax: (626) 812-3411 Rain Bird Technical Services (800) 247-3782 (U.S. only) Rain Bird Sales, Inc. 6640 South Bonney ve. Tucson, Z 85706 US Phone: (520) 434-6200 Fax: (520) 434-6246 Specification Hotline (800) 458-3005 (U.S. only) Rain Bird International, Inc. 145 North Grand venue Glendora, C 91741 US Phone: (626) 963-9311 Fax: (626) 963-4287 www.rainbird.com Rain Bird. Conserving more than water. Registered trademark of Rain Bird Sprinkler Mfg. Corp. 2000 Rain Bird Sprinkler Corp. 10/00 P/N 232094