ipdatatel CDMA-BAT Installation

Similar documents
BAT LTE SKU: IPD-BAT-LTE

BAT WIFI SKU: IPD-BAT--WIFI

Resolution Compatibles Flex GSM IGM is a GSM cellular device that provides

Installation & Operations Manual

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

SYSTEM ENHANCEMENT MODULE

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

Tech Support Line: (715) Concord 4 RE927X

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Pella Insynctive Product Guide

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

Safewatch QuickConnect

Smart Water Heater Controller

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option

EVO192 v3.0 Fire and Burglary What s New

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

National Broadband Network. User Guide. Includes important information about your NBN equipment

600 Range Dialer Installation Manual. Version 1.0

15R HARDWARE INSTALLATION GUIDE

Pre-Installation Requirements:

ADEMCO LYNXR-I Security Systems

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Installation Manual Chevrolet Vehicles

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99

PiSector GSM Cellular Wireless Alarm System

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Installation Manual Mopar Engine Compartment Upgrade Kit

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00

Table of Contents. What to Expect with. Mounting Options. Tools Needed

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

ALARM OUTPUT MODULE. Product #7736

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

IP & SMS Alarm Communicator

SYSTEM ENHANCEMENT MODULE

For all new Fibre Optic Lots Stages 41B to 80

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

Installation Guide for. Energate Thermostats. Pioneer release 2.3 and HōlHōm/Foundation release 3.5

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Weatherproof 14" x 12" x 7" Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

RAYPAK REPLACEMENT INSTRUCTIONS

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Installation Instructions

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

Your user guide. Useful information about your nbn supplied equipment

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Installation and Programming Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

CPS3200U Technical Support Guide

RESOLUTION PRODUCTS 2015 COMPATIBLES CATALOG

Long Range Radio Alarm Transmitter

Installation Instructions

Instruction Manual. Remote Monitoring System

Table of Contents. 1 M /11/13 Casablanca Fan Company What to Expect with Your Installation

User Guide. Fibre Connection. For installations after July 1st 2013 Includes information about your NBN equipment

Ge Alarm Systems Control Pad Nx Manuals

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM.

VISTA-10SE. Security System. Installation Instructions Installation Instructions Installation Instructions

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

ET083 2G/3G COMMUNICATOR

Installation Guide for Stern SPIKE 2 Speaker Light Kits

9,67$39,67$3&1 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH K /01 1 OFF 4 MAX OFF 7 INSTANT 9 CHIME READY

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

Q3200 Smart Home Alarm. Kit Content and Installation Guide

Alarm Getting Started

Long Range Radio Alarm Transmitter

IRIS Touch Engineering Manual. Version 1.2

Ring Alarm Kit Base Station, Key Pad, Contact Sensor, Motion Detector, Range Extender

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22

AT&T Switched Ethernet on Demand

Wireless High Bay Sensor (WHS100) Installation Instructions

Installer Guide smart connect

DRAIN WATER TEMPERING INSTALL

IPGSM-DPC Commercial Fire Communicator

Installation Instructions

3SA60 3SA60+LED. Vogue & Vogue Plus. Net weight. This instruction contains 11 pages:

Installation & Operation Manual

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

ET082 GSM/GPRS COMMUNICATOR

SENTROL ZX200/ZX210. Security System Control. Installation/ Programming

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

INSTALLATION GUIDE XR150/XR550 SERIES CONTROL PANEL

BASIC SYSTEM LOCATION INDEX

Installer Guide smart connect

Install Guide Customer Support: or Visit our website

INSTALLATION INSTRUCTIONS

CEILING FAN OWNER S MANUAL

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Security + Automation Made Easy QUICK START GUIDE

Transcription:

ipdatatel CDMA-BAT Installation This guide is for our customers who want to install the ipdatatel equipment before their programming appointment. This guide covers installing the IPD- CDMA-BAT with Vista, DSC, or Caddx systems in detail. If you would like assistance through the full installation process or you do not have a Vista/First Alert/Safewatch Pro, DSC, or Caddx alarm system please contact us at 800-624- 6866. In these cases you must schedule an appointment, as the connection cables and wiring will vary substantially from this guide depending on the panel you have. If you have any questions regarding this guide please feel free to call us. When you first receive your IPDataTel it will look like this: 1

You will also receive 2 alarm connection cables that look like this: NOTE: One antenna will also be in the box your IPD unit shipped in. What you will need to install: -A small flathead screwdriver 2

Step 1: The first thing you need to do is remove the cover on the IPDataTel CDMA Broadband Alarm Transmitter (the white box) to expose the internal circuit board. There are tabs on the bottom of the case that you can press down to crack open the case. This is what the circuit board looks like: NOTE: As you can see there are 16 screw terminals adjacent to the left side of the board. We will be wiring from this board to the alarm panel circuit board later on in this guide. 3

You can go ahead and attach the antenna that was in the box to the IPDataTel as shown below: 4

Step 2: You will need to power down your alarm system as you will be working with low voltage. In order to do this you will want to disconnect the AC adapter or transformer for the alarm system from the wall outlet. If there is no transformer because the power wires are going into the wall behind the panel then you can disconnect one of the AC wires going to your alarm panel. Most often the AC wires are located on the first 2 terminals from the left on your alarm panel circuit board. You will also disconnect one of the leads going to the backup battery for your alarm system. You can disconnect red or black, it does not matter. Once you have verified that there is no power going to the system (no power to the keypad) you are ready to move to the next step. Step 3: The wiring from the IPDataTel will go to certain terminals on your system s circuit board, depending on your panel. This section shows you circuit boards for the most common and supported panels with the IPDataTel and which terminals to connect the wires to. Reference the wiring scheme for your particular panel type to ensure that the connections are made properly. NOTE: When you are wiring to your alarm system, make sure you run any cables/wires through any available holes in your control panel enclosure so that you can ultimately close the alarm panel box once the installation is complete. The same applies to wires that are connected to the ipdatatel. 5

Vista Circuit Board Wiring As you can see on the Vista panel there are about 25 screw terminals down the bottom. You will take the cable that has 4 different colored wires (red, black, green, and yellow) exposed on each end and screw them in to the terminals in the following order (refer to pg. 13 for diagram): Terminal 4 from the left: Black wire Terminal 5 from the left: Red wire Terminal 6 from the left: Green wire Terminal 7 from the left Yellow wire You ll notice that there are other wires already going to these terminals. Those wires will stay there along with the newly installed wires. Do not remove them as they are typically responsible for your keypads. Now you will want to take the cable that has 2 exposed wires on each end (red and green) and then connect the wires to the terminals on the alarm circuit board in the following order: Terminal 24 (2nd terminal from the right): red wire Terminal 23 (3rd terminal from the right): green wire 6

NOTE: You may already have wires going to terminals 21-24 on the Vista system before connecting the wires we shipped you. Disconnect any wires going to terminals 21-24 before connecting the wires we supplied. If you have made the connections as mentioned above, you may move to Step 4 (pg. 10). DSC Power Series Circuit Board Wiring As you can see, this panel has about 25 screw terminals down the bottom of the board. Using the cable with 4 different color wires on each end, you will wire up to the panel as follows (refer to pg. 14 for diagram): Terminal RED from the left: red wire Terminal BLK from the left: black wire Terminal YEL from the left: yellow wire 7

Terminal GRN from the left green wire You ll notice that there are other wires already going to these terminals. Those wires will stay there along with the newly installed wires. Do not remove them as they are typically responsible for your keypads. Now you will want to take the cable that has 2 exposed wires on each end (red and green) and then connect the wires to the terminals on the alarm circuit board in the following order: Terminal Ring from the right: red wire Terminal Tip from the right: green wire NOTE: You may already have wires going to terminals TIP, RING, R1, and TI on the DSC system before connecting the wires we shipped you. Disconnect any wires going to these terminals before connecting the wires we supplied. If you have made the connections as mentioned above, you may move to Step 4 (pg. 10). 8

Caddx NX Series Wiring Diagram As you can see, the terminals we need to connect to on this system circuit board are Data, Com, Positive, Red, and Green. Sometimes, they are labeled KP Data, KP Com, and KP Positive as well. You will wire the cable with the 4 wires on each end (red, green, black, and yellow) to this panel (refer to pg. 15 for diagram). Terminal Data : Green Terminal Com: Black Terminal Positive: Red The yellow wire on this cable will not be used. Just leave it to the side or snip it off. 9

You ll notice that there are other wires already going to these terminals. Those wires will stay there along with the newly installed wires. Do not remove them as they are typically responsible for your keypads. Now you will want to take the cable that has 2 exposed wires on each end (red and green) and then connect the wires to the terminals on the alarm circuit board in the following order: Terminal Red from the top: red wire Terminal Green from the top: green wire NOTE: You may already have wires going to terminals Gray, Red, Green, and Brown on the Caddx system before connecting the wires we shipped you. Disconnect any wires going to these terminals before connecting the wires we supplied. If you have made the connections as mentioned above, you may move to Step 4. Step 4: The next step is to wire the other ends of the two cables you connected to the alarm panel terminals to the terminal strip on the IPDataTel (black circuit board). This is what the terminal strip looks like: NOTE: The wires need to be inserted through the square shaped holes (terminals) that are part of the green terminal strip. The screws should already be loosened so you will just need to tighten them. 10

Using the cable with the 2 wires on each end: Terminal 1: wire the green wire to this terminal. Terminal 2: wire the red wire to this terminal. Using the cable with the 4 wires on each end: Terminal 3: wire the red wire to this terminal. Terminal 4: wire the black wire to this terminal. Terminal 5: wire the yellow wire to this terminal. Terminal 6: wire the green wire to this terminal. Step 5: Power up the Alarm Panel. To do this you will reconnect the battery leads first and then connect the transformer (ac adapter) to the wall outlet OR if you disconnected the AC wire to the left-most terminal on the panel you will want to reinsert that wire and secure it. 11

Step 6 (optional): Plug an Ethernet cable (CAT-5 or higher) into the RJ-45 jack on the IPDataTel circuit board and run that cable to an open port on your router. Step 7: Congratulations. You have successfully installed and configured the product. Seal the IPDataTel CDMA BAT enclosure and your alarm panel box. You can mount the IPDataTel on the wall if you would like. Then you will need to contact us at 800-624-6866 to schedule a programming appointment if you have not done so already. 12

Appendix Ademco Vista Series Panel Wiring Diagram with Relevant Terminals Highlighted 13

DSC Power Series Panel Wiring Diagram With Relevant Terminals Highlighted 14