HL45, HL80 Thermostatic High-Low Valves

Similar documents
TMV45 & TMV80 Standard Thermostatic Mixing Valves

Installation S

Installation S

Installation S

Installation S

Installation S

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

Automatic Temperature Controller (ATC)

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

WATER TEMPERATURE CONTROL SYSTEMS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

CLASSIC HIGH LOW MANIFOLD SYSTEMS

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

Product Specification

NEW GENERATION HIGH LOW SYSTEMS

DigiTemp. Digital Water Tempering System. PVI.com

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

INSTALLATION ADJUSTMENT SERVICE

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

WATER CONTROL VALVES

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

2016 CASH ACME CATALOG

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Packaged Semi-Instantaneous Steam Fired Water Heater

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

INSTALLATION ADJUSTMENT SERVICE

WF2613 Classic Corner Washfountain with 9" Deep Bowl

Wall Mounted Shower Systems

Thermostatic mixing valves with interchangeable cartridges

7000BT Eye/Face Washes

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

SECTION DOMESTIC WATER PIPING SPECIALTIES

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

Components only, Unassembled, 4" Metal Control Box. (Order separately) 860T T T T158

ADMS. AERCO Digital Mixing Station. AERCO.com

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

SSBF2150 Recessed Safety Station with Drain Pan, Exposed Shower Head

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

SN2003, SN2023, SN2004, SN2024

FL-2H, FL-2L Frequency Lavatory System FL-Series

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Domestic Hot Water Systems and Plumbing Products

Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

A. This Section includes the following domestic water piping specialties:

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

WALL MOUNTED SHOWER SYSTEMS

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

OUTLET HOT INLET COLD INLET INSTALLATION

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

BASIL 6000 TUNNEL CAGE WASHER

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

ADA Compliant Wall-Mount Fountain and Bottle Filler

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

SPEAKMAN SPEAKMAN SPECIFICATIONS

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

WF2613 Classic Corner Washfountain with 9" Deep Bowl

A. This Section includes the following emergency plumbing fixtures:

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

CLE SERIES Fluid heating for emergency eyewash stations

TOP 15 :: EMERGENCY EQUIPMENT

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

Packaged Steam Fired Water Heater

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

Flow Control for Fire Protection

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE PRODUCTS EYE/FACE WASH :: SHOWERS COMBINATION UNITS

Thermostatic mixing valves with replaceable cartridge for centralized systems

Transcription:

Lead-Free Brass Design Reliable Liquid-Filled Thermostat with 10 year warranty Integral Strainer Checkstops on Inlets Adjustable Set Point within Temperature Range Accurate Temperature Control to within ±3 F Positive Shutoff of Flow in the Event of Cold Supply Line Failure or Thermostat Failure Easy Installation and Serviceability Dirt and Lime Resistant Factory Assembled and Tested Universal Mounting Capability Dial Thermometer Cabinet Features: 18 Gauge Body & Left-Hand Hinge Cylinder Lock Inlet/Outlet Knock-Out Holes for Mounting Flexibility Stainless Steel or Baked White Enamel Finishes Surface-Mounted or Recessed Style with Flange Valve Specifications Maximum Operating Pressure 125 PSI (860 kpa) Maximum Inlet Temperature 200 F (93 C) Temperature Range Std. 90 F (32 C) to 120 F (49 C) Low 70 F (21 C) to 100 F (38 C) High 110 F (43 C) to 140 F (60 C) Flow Capacities GPM (L/Min) Model S59-3045 S59-3080 Min* Flow 1.5 (5.5) 2.0 (7.5) 5 (.5) 12.5 (58.0) 26.0 (110.0) 10 (1.0) 19.0 (89.0) 36.0 (157.0) Set Point 110 F (43 C) 80 F (27 C) 130 F (54 C) Pressure Drop PSI (Bar) 15 (1.5) 24.0 (115.0) 44.0 (193.0) 20 (2.0) 28.5 (137.0) 51.0 (223.5) 30 (2.5) 37.0 (157.0) 63.0 (250.5) 45 (3.0) 47.0 (175.0) 77.0 (275.0) 60 (4.0) 56.5 (209.0) 88.0 (318.0) * Recirculation system only (See diagram on Page 2). When properly installed near the hot water source with a continuously operating recirculation pump, the valve will maintain set temperature with a.5 GPM (2.0 L/Min) draw from the plumbing system. Code Compliance and Certifications ASSE 1017 & cupc certified. Complies with California Lead Plumbing Law. HL45 (Part No. S59-3045) Models (Must select one) Model Description S59-3045 HL45-Thermostatic Mixing Valve S59-3080 HL80-Thermostatic Mixing Valve Optional Selections Finish C Chrome Plated Thermostat L Low Range Thermostat H High Range Thermostat Bracket B Wall Mounting Bracket Piped Assembly P Piped Assembly with Inlet and Outlet Shutoff N Piped Assembly with Outlet Shutoff Cabinets SS Surface Mount Stainless Steel RS Recessed Stainless Steel SE Surface Mount White Enamel RE Recessed White Enamel W Plexi-glass Window in Lead Free Engineer's Approval Page 1 of 6 8/19/2014 Certified to NSF/ANSI 372 Wetted surface contains less then.25% lead Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ ANSI 372 meeting the Lead-Free content requirement.

Recirculation Diagram Check Valve (Typ) Cold Tempered Water Flow Cold Water Heat Trap 28" Drop Check Valve Alternate Recirculation (More than 5 GPM) Balancing Valve (Typ) Return Flow Recirculating Pump Recirculated Tempered Water Temperature Switch Water Heater Storage Tank Dimensions Model A B C D E S59-3045 7" (178) 3-1/4" (84) 4-3/4" (119) 8" (203) S59-3080 8-3/4" (224) 2-1/ (64) 3-1/ (89) 5-1/4" (135) 12-1/4" (312) Model F G H X NPT Y NPT Z NPT S59-3045 14" (356) 3-1/8" (79) 9-1/4" (234) 3/4" 1" 3/4" S59-3080 19" (483) 3-5/8" (91) 11-3/8" (290) 1" 1-1/4" 3/4" Y NPT B Z NPT E F Min. C D Page 2 of 6 8/19/2014 X NPT A H X NPT G

Dimensions HL45 Surface-Mounted Cabinet 1" NPT Outlet 22-3/4" (578) 10-1/ (267) 22-3/4" (578) 6-1/ 3/4" NPT Inlets 8-1/ (216) 7" (178) Back 6-1/4" (159) 7-1/ (191).47" Dia. Holes 6 Places 20" (508) 8-7/16" (214) Page 3 of 6 8/19/2014 20" (508)

Dimensions HL80 Surface-Mounted Cabinet 1-1/4" NPT Outlet 2-1/4" (57) 10-3/16" (259) 22-3/4" (578) 2-1/ (64) 26-3/4" (679) 28" (711) 2-1/ (64) 7-5/8" (194) 8-3/4" (222) 6-1/ 1" NPT Inlets Back 5-1/8" 9-3/4" (130) (248).47" Dia. Holes 6 Places 9-3/16" (233) Page 4 of 6 8/19/2014 20" (508)

Dimensions HL45 Recessed Cabinet 10-1/ (267) 22-3/4" (578) 1" NPT Outlet 5" (127) 22-3/4" (578) 26" (660) 14" (356) 8-1/ (216) 7" (178) 26" (660) 3/4" NPT Inlets.28" Dia. Holes 2 Each 4 Total 6-1/ Page 5 of 6 8/19/2014

Dimensions HL80 Recessed Cabinet 10-3/16" (259) 22-3/4" (578) 2-1/4" (57) 1-1/4" NPT Outlet 5" (127) 2-1/ (64) 26-3/4" (679) 18" (457) 28" (711) 30" (762) 2-1/ (64) 7-5/8" (194) 8-3/4" (222) 1" NPT Inlets 26" (660).28" Dia. Holes 2 Each 4 Total 6-1/ Page 6 of 6 8/19/2014