FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Similar documents
FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER CONCERTINA TM

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

PRODUCT SPECIFICATION FireMaster Plus

FIRE & SMOKE CURTAINS

PRODUCT SPECIFICATION FireMaster Plus Concertina

FIRE & SMOKE CURTAINS

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

PRODUCT SPECIFICATION FireMaster Concertina

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

Smoke and Fire Curtains

Technical Manual (European Standards)

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Firetex steel fire shutters

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

ACTIVE FIRE CURTAINS INTISI7

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

A REVOLUTIONARY APPROACH TO FIRE SAFETY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

BLE Smoke and Fire Curtains

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

SMOKE AND FIRE CURTAINS

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Fire Protection. Intumescent fire and smoke seals for door assemblies

A Guide To BS Understanding the selection, spacing and siting of detectors

Dublin airport - Dublin, Ireland

Perimeos. Ceiling Recess. decor. systems

fire resistance testing

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM

Building Services Brochure

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Fire and Security Products and Services

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

Fire Suppression Systems

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

Element C3.5 Means of Escape

New 10YR. The market leading range of fire-rated LED downlights. Introducing FGLED10 WARRANTY

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

Analogue addressable devices

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

Life Safety and Fire Resistant Glazing Systems

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN

SENSA MRE DDM MR

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Remote Control Garage Doors

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Enriching Environments

Operation & Maintenance Manual

HYBRID PLUS2 AIRCOOL VENTILATORS

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

The Passive Fire Protection Handbook

Disabled persons toilet alarm kit from Cameo Systems

FIRE DOOR CLOSING SYSTEMS

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

FIRE TESTING SERVICES FIRE TESTING SER

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Fire Rated Door Assemblies: Compliant Designs

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Guide to: 17 th Edition Consumer Units

FIRE SAFE NOTICE BOARDS Education Buildings SPECIFYING FIRE RATED NOTICE BOARDS. Issue #1

MEDIUM-DENSITY HOUSING # 7. Fire safety

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

shower panel specification manual 2008

Schueco Fire and Smoke Protection Systems

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Transcription:

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION

MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK Active Fire Curtain Barrier Assemblies comprise technologically advanced fire-resistant fabric barriers encased in a compact steel housing. Barriers remain invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their operational position. To be compliant, Fire Barriers must be protected from a short circuit and or total power failure, this is achieved with our patented Total Gravity Fail-Safe (TGFS) system. Fire barriers will stop and control the spread of fire in a building. The revolutionary FireMaster Plus 2 Curtain Barrier uses a fabric that is an exclusive development and woven and produced by Coopers themselves. It uses a unique rapid reaction graphite flake which expands to over 20 times its original thickness on exposure to heat and fire, creating an insulating carbon barrier to heat. REDUCES RADIANT HEAT - FireMaster Plus 2 reduces radiant heat to under 10 kilowatts per sq mtr for 60 minutes. You can escape safely just a few inches away from a +600 o C fire (over 3 times the heat of a domestic oven) STOP FIRE SPREADING - FireMaster Plus 2 stops fire for 180 minutes and offers a protected means of escape FAST REACTION TIME - FireMaster Plus 2 expands twice as fast and double the thickness of any other product when exposed to heat and fire Single Roller Assembly At the centre of the SSE Hydro s interior is its large, open plan atrium purposely designed to complement the venue s unique exterior looks. However, ensuring that the SSE Hydro s open plan designs meet stringent fire regulations required a modern alternative to traditional fire protection equipment. As the leading manufacturer of fire and smoke curtains, Coopers were appointed to protect the un-insulated glazing installed above the atrium s reception area with an approved fire curtain barrier system approved to provide a 2 hour insulating zone. Coopers also developed a smoke curtain system to provide an unintrusive method capable of controlling smoke migrating from the lower floors. Wide Single Roller Assembly Coopers installed two FireMaster Plus fire curtain barriers to deploy vertically to protect the atriums angled glazing situated on the first floor. Developed and installed to meet fire regulations, the FireMaster Plus fire curtain barriers will provide the SSE Hydros un-insulated glazing with an insulating zone approved to protect a means of escape for up to 2 hours. BENEFITS PRODUCT ADVANTAGES Remove walls and partitions to create wide open spaces Remove fire doors to make free flowing corridors Total Gravity Fail- Safe (TGFS) operation ensures safe rates of descent even following total power loss, wiring, short circuit or system corruption Single roller assembly curtains for spans up to 4m as standard and Wide Single Roller assembly curtains for spans over 4m as standard Fully synchronised intelligent drive system with slave line for multiple rollers All barriers allow egress for occupants and for emergency services PAS 121 compliant Accredited by Independent Third Party Certification for both Product and Installation Manufactured by Coopers in the UK under BS EN ISO 9001 and 14001 systems Total Gravity Fail-Safe (TGFS) 2 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 3

INSULATING ZONE - PROTECTED MEANS OF ESCAPE STANDARD HEADBOX SIZES FMP/H 19/23 FMP 24/29 FMP/WSR H FMP/WSR 25/30 FireMaster Plus 2 Fire Curtain EW60 (60 minutes Radiation) Means of Escape Tenable Zone FMP 15/20 SS FMP 18/26 SS FMP/WSR 30/34 1 metre Maximum Radiant Heat allowed: 15kW/m 2 at 1 metre distance FireMaster Plus 2 Performance: Under 5kW/m 2 at 20 minutes at 1 metre distance SIDE CHANNELS Side channels seal the curtain fabric and the building. Fire can cause extreme positive or negative pressures. Side guide channels are made from galvanised steel (available in standard RAL colours) that can be either surface mounted or recessed into the wall structure to give a flush finish. Coopers unique fabric locking system has been developed and proven over many years. Model No. Maximum Barrier Width up to Maximum Barrier Drop up to FMP/H 19/23 4 metres 4 metres FMP 15/20/SS 4 metres 2.5 metres FMP 24/29 4 metres 3 metres FMP 18/26/SS 4 metres 4 metres FMP/WSR H 10 metres 4 metres FMP/WSR 25/30 17 metres 4 metres FMP/WSR 30/34 17 metres 6 metres Coopers has a design solution for any size requirement. See the chart below for our standard range of sizes. For queries about special size requirements, please contact our technical department. End Fixed Face Fixed Recessed Fixed (Recommended 5mm gap between side guide and building material) HOW THE HEADBOXES ARE INSTALLED Unistrut and Drop Rods I Beam Face Fixed Soffit Fixed There are many fixing options to suit all types of ceiling configurations. Barriers can be integrated with both solid and suspended ceilings, enabling total project design flexibility. 29 90-100 Adjustable 4 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 5

HOW ARE THE BARRIERS CONCEALED? FireMaster Plus 2 systems provide a range of ceiling interfaces and can even invisibly conceal the barriers in the ceiling whilst still allowing for service and maintenance. All our systems remain totally concealed when non-operational. CONTROL OPTIONS Controls are custom made to be fully compatible with both existing alarm systems and the number of barrier units installed, whether single or multiple roller assemblies. CONTROLS SPECIFICATION POWER SUPPLY 230V AC 50Hz dedicated supply via all pole isolator Coopers also design and build Grouped Control Panels to accomodate customers requirements. This allows all controls to be installed within a single enclosure for easier installation, commissioning, servicing and reduction in field wiring. Please contact Coopers for more information on Grouped Controls. When an alarm signal is detected, the control panel will automatically trigger all the Barrier systems to deploy by controlled descent using our unique Total Gravity Fail- Safe (TGFS) system. Alarm BATTERIES 2 x 12V 12A/h lead acid batteries ALARM SIGNAL Normally closed volt-free contacts. Open on activation TEST FACILITY Zone Control Panel (ZCP) located on front of Power Supply Unit (PSU) 1 PSU can operate up to 20 motors PSU MCU 200 DISPLAY Power ON, Alarm ACTIVE and Alarm OFF status LED s on ZCP For illustrative purposes only Flush Fit Suspended ceiling with SLAT (Self Levelling Access Trim) the unique patented Coopers system Reinforced Suspended ceiling with recessed shadow gap 500 210 400 80 300 POWER SUPPLY SIZE 400mm(w) x 500mm(h) x 210mm(d) MOTOR CONTROL UNIT SIZE 300mm(w) x 200mm(h) x 80mm(d) HOW IS THE BARRIER ACCESSED? Standard Wide Single Roller (WSR) no overlaps (Remember, regular service and maintenance is a legal mandatory requirement) Flush Fit Suspended ceiling with SLAT (Self Levelling Access Trim) the unique patented Coopers system Reinforced Suspended ceiling with recessed shadow gap 17m maximum (if larger width required contact Coopers for an engineered solution) QUALITY ASSURANCE AND CERTIFICATION PRODUCT SPECIFICATION DON T BE LIABLE min 300mm The complete system is tested for 180 minutes (3 hrs) to BS EN 1634-1:2008 and is classified as E180 EW60 S a C2 Grade 3 in accordance BS EN 13501 2:2007+A1:2009. It also meets the requirement of BSI PAS 121:2007. The fabric is additionally tested for fire propagation to BS 476 6:1989+A1:2009 and surface spread of flame to BS 476-7:1997 to achieve National Class 0 in accordance with A13(b) of Approved Document B (Volumes 1 & 2) 2006 Edition Fire Safety to England & Wales Building Regulations 2000. Fire Curtain Barriers MUST have a Total Fail- Safe by Gravity* in the event of total mains, wiring, short circuit and/or system corruption. Coopers Fire, with their unique patented Total Gravity Fail-Safe (TGFS) system, are the only supplier with Independant Third Party Certification by a UKAS approved certification body to BSI PAS 121:2007 and now meets essential requirements of BS 8524-1:2013. MEMBERSHIP CPD ACCREDITATIONS EFP TM 2/1000/DGI is a high performance textile composite material of woven glass fibre with an intumescent graphite silicone coating on both sides. This forms a rapid, expanding carbonaceous char at 160 o C and reduces heat radiation.this coating was developed and used first by Coopers Fire. 6 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 7

For information, to get a quote or to book a CPD workshop Please call: +44 (0)2392 454 405 or E-mail: info@coopersfire.com WWW.COOPERSFIRE.COM Coopers Fire Ltd, Edward House, Penner Road, Havant, Hampshire, PO9 1QZ United Kingdom Phone: +44 (0)2392 454 405 Fax: +44 (0)2392 492 732 Email: info@coopersfire.com Web: www.coopersfire.com Coopers Fire Ltd has a policy of continuous product improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website for the latest information. Coopers Fire Ltd. All content and products are copyright of Coopers Fire Ltd. Registered in England Number: 2010274. *Multiple patents granted and pending. Series 2 v06 May 2017 8 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION