ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Similar documents
ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

CDL8 LED Architectural

HIGH BAY APPLICATIONS

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

SERVICE BY QUALIFIED PERSONNEL ONLY

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

ESRB and ESRN Installation & Safety Instructions

Exit/Emergency Lighting Guide

IOTA Exit Signs. IOTA Emergency Fixtures

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Emergency Lighting. Product Guide LED. The right source for the. right light

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

INSTALLATION INSTRUCTIONS

Bdl60u Fluorescent Emergency Ballast

Honeywell Durafit LED Retrofit Kit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

1 General Description

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Grüv Flare Regressed. Recessed Linear LED

2018 Instant Lighting Rebates Product Catalog

FPLHB - Fidelux Premier Linear Highbay

SECTION INTERIOR LIGHTING

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Grüv Flare Regressed. Recessed Linear LED

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

MaxLite LED Round Pendant Highbay Series

Catalog Number. Notes

BAS SFP22 Edge-lit LED Panel

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Installation Instructions

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

Installation Instructions

Cold Door 2 LED Retrofit Kit Lighting System

BeveLED Cylinder LBRP6 Surface

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Highbay Linear LED Series Flat Profile Design

LED Emergency Battery Backup

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

LED Edge-Lit Flat Panels

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

FET22 (2x2) 25W & 40W Series

HIGH LUMINOUS EFFICIENCY

Eligible Prescriptive Measures List:

MaxLite LED MICRO-T PANEL

PROJECT DATE FLANGE FINISH

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

SECTION LIGHTING CONTROLS

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

110 lm w STANDARD SERIES

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

WPLED 26W INSTALLATION INSTRUCTIONS

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

DHL-LP-LED Low Profile LED Linear High/Low Bay

Cold Deck Canopy and Shelf Lights and Retrofit Kit

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Spectron LSN (Life Safety Network) Suggested Specifications

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1 x4 Dimmable LED RetroFits

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

RECESSED Spec Guide. up to 111 lm/w performance

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

P5500 LED Architectural Downlighting

Installation Instructions

Model 17A00 Expansion Enclosure

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Evoke Square Downlight

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

PRODUCT DATA SHEET LIGHTING PRODUCTS

Fino Healthcare. Asymmetric Wall Mount Indirect LED

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Series / Housing Style Lumens CCT CRI Beam Driver Voltage 2 Options. 80CRI 15D 15 beam 35D 35 beam 45D 45 beam

Transcription:

P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is supplied to the unit. 2. CAUTION This fixture provides more than one power supply output source. To reduce the risk of electrical shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnecting the unit connector. 3. CAUTION This is a sealed unit. Components are not replaceable. Replace the entire unit when necessary. 4. CAUTION Installation and servicing should be performed by qualified personnel only. De-energize before opening. 5. The ILB is for use with grounded LED luminaires listed to UL standards. Not for use in heated air outlets or hazerdous locations. 6. The ILB requires an unswitched A.C. power source of 120 to 277 volts, 50/60 Hz. 7. The ILB and A.C. driver must be on the same branch circuit. 8. Do not mount near gas or electric heaters. 9. The ILB should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 10. The ILB will supply 10-60 VDC output at the individual rated specification for 90 minutes. See individual units for output specifications. 11. Suitable for use in damp locations and plenum spaces. 12. Suitable for Luminaires, recessed Type IC (intended for insulation contact). 13. For use in 0 C minimum, 55 C maximum ambient temperatures. 14. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void warranty, and result in non-compliance with UL specifications. 15. Do not use this equipment for other than intended use. 16. Install in accordance with the National Electrical Code and local regulations. 17. Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before final installation. See addendum for compatibility and covered luminaire requirements. SAVE THESE INSTRUCTIONS CLASS 2 OUTPUT

INSTALLATION INSTRUCTIONS CAUTION: Before installing, make certain the A.C. power is off and the ILB unit connector is disconnected. 1. FIXTURE The ILB-CP can be used with most LED loads that operate at 10-60 VDC. See the ILB Model Specification Chart for output specifications of the unit being installed. 1. The ILB-CP series has been evaluated to and found compliant to UL standard 924. The as-installed performance of system must meet or exceed all Federal, State, and Local code requirements. 2. Refer to Addendum 11042014 for detailed specifications and methods to calculate emergency light levels. ILB MODEL SPECIFICATION CHART OUTPUT POWER (CONSTANT) ILB-CP05 ILB-CP07 ILB-CP10 ILB-CP12 2. MOUNTING THE ILB The ILB should be mounted on or nearby the fixture above the ceiling. The flex conduit marked A should be wired into the driver/lamp compartment or to an electrical junction box on the fixture which allows access to the fixture connections. Refer to Illustration 1 for typical mounting. When battery packs are remote mounted, consult Customer Service for the maximum allowable distance between the battery pack and the load. 3. WIRING Refer to the wiring diagram on the back page for the appropriate wiring of the LED load and driver. Install in accordance with the National Electrical Code and local regulations. For additional wiring diagrams consult Customer Service. 4. MOUNTING THE TBTS TEST ACCESSORY Cut a single gang switch box into the ceiling tile adjacent to the fixture within reach of the ILB flex conduit marked B. After mounting the switch box, connect flex to the box and route all leads inside the box. Refer to Illustration 1 for typical mounting. For proper operation, use only the accessory components provided with the unit. See Page 1 of the Instruction Manual. Illustration 1 Downlight Fixture FLEX A ILB A.C. LED BALLAST FIXTURE & LAMP SOCKET C FLEX B JUNCTION BOX SWITCH BOX CEILING TILE TEST SWITCH TEST ACCESSORIES TBTS CHARGE LIGHT Page 2

5. LABELS Attach the appropriate labels adjacent to the TBTS. Annotate Replacement Label with identical manufacturer part number(s). The Caution and the Replacement labels must be on the fixture in a readily visible location to anyone attempting to service the fixture. 6. WIRING THE A.C. INPUT A. The ILB and A.C. driver MUST be on the same branch circuit. B. The ILB requires an unswitched A.C. power source of 120 to 277 volts, 50/60Hz; therefore when used with switched fixtures, the ILB input must be wired ahead of the switch. C. Refer to the wiring diagrams on the back page for the proper wiring. For wiring diagrams not shown, consult our customer service. 7. COMPLETING INSTALLATION When the installation is complete, switch the A.C. power on and join the ILB unit connector. OPERATION Normal Mode A.C. power is present. The A.C. driver operates the LED load as intended. The ILB is in the standby charging mode. The TBTS will be lit providing a visual indication that the battery is being charged. Emergency Mode The A.C. power fails. The ILB senses the A.C. power failure and automatically switches to the Emergency Mode. One or multiple LEDs are illuminated, for a minimum of 90 minutes. When the A.C. power is restored, the ILB switches the system back to the Normal Mode and resumes battery charging. See page 1 of the Instruction Manual. TESTING & MAINTENANCE Pressing the TBTS turns off the light on the TBTS and forces the unit into emergency mode, interrupting power to the designated A.C. driver. The LED load is now being lit by the ILB unit. After releasing the TBTS, the fixture returns to normal operation after a momentary delay. To simulate a BLACK OUT use the circuit breaker to turn off A.C. power. Initial Testing Allow the unit to charge approximately 1 hour, then conduct a short discharge test. Allow a 24 hour charge before conducting a one hour test. The ILB is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety Code, outlines the following schedule: Monthly Insure that the TBTS light is illuminated. Conduct a 30 second discharge test by depressing the TBTS. At least one LED should operate at reduced output. Annually Insure that the TBTS is illuminated. Conduct a full 90 minute discharge test. The unit should operate as intended for the duration of the test. Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction. SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL. Consult Customer Service or visit www.iotaengineering.com for current warranty information. Page 3

TYPICAL WIRING DIAGRAM For other diagrams, consult our Customer Service. SWITCHED OR UNSWITCHED HOT BLACK (120V) ORANGE (277V) WHITE AC (NORMAL) DRIVER LED OUTPUT (-) LED OUTPUT (+) LED INPUT(+) LED INPUT (-) LED LOAD COMMON WHT/BLK WHT/BLK WHITE UNSWITCHED 24/7 POWER BLK/ORG (120 TO 277V, 50/60HZ) IOTA ILB-CP EMERGENCY DRIVER RED (+) BLUE (-) RED/WHT (+) BLUE/WHT (-) TBTS TEST ACCESSORY WHT/RED RED OR RED/BLK (+) UNIT CONNECTOR ATTENTION: DO NOT MATE UNIT CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. TEST ACCESSORY LEADS-OBSERVE PROPER POLARITY WIRING. SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. NO POLARITY ON WHT/BLK LEADS. USE EITHER LEAD FOR CONNECTION TO BUILDING COMMON (SWITCHED OR UNSWITCHED) AND OTHER FOR CONNECTION TO AC DRIVER. CONNECT UNSWITCHED POWER. IF A SINGLE BUILDING COMMON IS PRESENT, CONNECT THE WHITE WIRE TO THE COMMON. IF A SEPERATE UNSWITCHED CONDUCTOR FEED IS PRESENT, CONNECT THE WHITE LEAD TO THE COMMON FROM THE UNSWITCHED FEED. MATE UNIT CONNECTOR AFTER INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED 68A07-109 REV 1605 Page 4

CP Series Compatibility and Suitability of Use Guidelines Addendum (Rev.11042014) The purpose of this addendum is to sufficiently identify electrical compatibility and predictable emergency light output of the LED luminaire when used with the IOTA ILB-CP Series LED emergency drivers. Verification of these operating traits does not constitute a code-compliant, as-installed emergency egress system. It is still the responsibility of the Designer/ Specifier to assure appropriate light levels are achieved during emergency operation of the luminaire in accordance with Federal, state and local municipal codes regarding path of egress illumination. 1. Determining Electrical Compatibility 1.1 Verify Class 2 compliant driver per driver manufacture specifications. 1.2 Verify that the Emergency Driver (ILB-CP Series) selected does not exceed the power delivered to the LED array (voltage and current) of the normal driver. 2. Calculating Lumen Output During Emergency Operation 2.1 Assess luminaire/fixture data. 2.1.1 DESIGNLIGHTS CONSORTIUM - Log onto the DesignLights Consortium website (www.designlights.org). - Click on search the DLC Qualified Product List button on the DLC homepage. - In the search by keyword text window enter: luminaire manufacturer name and part number. - Click on Search tab to open the Qualified Products List. - Determine per RATED DATA efficacy shown in lumens per watt - (lm/w). - Multiply lumens per watt by ILB-CP rated output (example: lm/w x 5 watts). Refer to table ILB MODEL SPECIFICATION CHART below for the wattage of the specific ILB-CP model to be used in the luminaire. (lm/w) x (ILB-CP Watts) = Minimum emergency lumens of fixture. - Determine per RATED DATA the wattage of the luminaire. ILB MODEL SPECIFICATION CHART OUTPUT POWER (CONSTANT) ILB-CP05 ILB-CP07 ILB-CP10 ILB-CP12 ILB-CP20 ILB-SL-CP05 ILB-SL-CP07 ILB-SL-CP10 ILB-SL-CP12 20 WATTS 3. Determining Adequacy of Means-of-Egress Lighting Levels 3.1 Follow industry standards by utilizing available.ies files and lighting design software for your dedicated emergency luminaires, with the above calculated emergency lumens, and validate your as-installed plans in accordance with the applicable life safety codes governing your project. While the ILB-CP series has been found compliant with the requirements of UL Standard 924, it is ultimately the responsibility of the Designer/Specifier to assure the as-installed system delivers codecompliant path of egress illumination in accordance with Federal, State or local municipal requirements. 68A07-109 REV 1605 Addendum Insert