Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Similar documents
EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

Nu-Heat UNDERFLOOR & RENEWABLES

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Thermostats & smart controls. neohub+ UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

ST9400A User Guide. Features

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Model: Touch-RF. 1 Wireless Series

Model: Slimline-RF. 1 Slimline Series

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Nu-Heat. options. warm water underfloor heating. design innovation expertise service U N D E R F L O O R

Nu-Heat. SPECIFYING NU-HEAT LoPro Max. A Best Practice Guide for professional installers

Operating instructions

ES3247B. 3 Channel Programmer. User and Installation Instructions

Underfloor Heating Programmable Thermostat

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE

heat interface units A BOILER WITHOUT A FLAME

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Model : PRT-EN Model: PRT-EN1

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

RF Programmable Room Thermostat User Instructions

Drayton Digistat +3RF

3 Channel Multi-Purpose Programmer User Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Model: Edge-HC. 1 edge-hc

4 in 1 Digital Thermostat Control

BOILERMATE A CLASS SP

Elegance. SMT-700 User manual. Ver

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Model: Slimline-N. 1 Slimline Series

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

- Data Brochure Steam Control 279

OPERATING INSTRUCTIONS

Programmable Towel Radiator Manual

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

ADVANCE ECB ELECTRIC COMBINATION BOILER

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

User Guide Y9420H Sundial RF 2 Pack 2

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Model: Slimline-B. Battery Series

User Manual THR870CUK Programmable Thermostat

Varenummer: Version:

Condensing Boiler RS100 Controller Training Program

: PRT / PRT PRT / PRT-N1

BOILERMATE A CLASS OV

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Daikin Altherma Small Monobloc User Guide

On initial power up the thermostat will guide you through set up procedure for the following:

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

Kills bills. How Vaillant technologies reduce home heating bills

iheat 25c iheat 30c iheat 35c

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

warm water underfloor heating installation manual v4b-aug 08 Nu-Heat design innovation expertise service

Sentinel Kinetic MVHR RANGE

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

irad Wireless Controller

4iE Smart WiFi Thermostat Operating Guide

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Hive Active Heating. Thermostat user guide

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

SEALED THERMAL STORE

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Daikin Altherma high temperature remote controller guide for schedule timers and operation functions

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

User s Manual

Daikin Altherma Hybrid User Guide

SYX660 Commissioning Guide V Page 1 of 55

USER GUIDE VOGUE MAX SYSTEM

C-Stat 17-ZW User Instructions

GB24 & GB30. User Manual

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

User Guide for EHE & EHE Programmable Room Thermostat

Installation & User s Instructions

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Designer TT Programme Set Up

Digital Thermostat Models: VS30W and VS30B

U538 12/11. Zoning. Replaces: 08/10. tekmarnet 4 Thermostat 538. User Manual. 1 of U /11

systemate 2000 fully integrated thermal store

End User Manual ACO 35 MFFI COMBI

ES-LCD User Control SD Card Location

Thermotouch Dual Dual Control Thermostat

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Transcription:

Underfloor heating user guide DS thermostats with timeclock v18 Nu-Heat 2018 UNDERFLOOR HEATIN HEAT PUMPS SOLAR THERMAL

working with you before, during & after your project Nu-Heat Know-How 2 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

Contents Welcome 04 About the Nu-Heat system 05 System startup 05 Operation 06 Systems with dial thermostats & timeclock 07 Operating instructions for the dial thermosat 08 3-position slide switch 08 Leaving the building unoccupied 08 Sensor 09 Heating options 09 Operating instructions for the timeclock 10 Zones 10 Normal run mode 10 Setting the clock 10 Selecting 5/2 or 7-day programming 10 Programming a holiday 10 Adjusting switching times 11 Mode select 11 Copy function 11 Boost facility 11 Cleaning 11 eneral system checks 12 eneral sequence of operation 13 Manifold components 13 Seasonal adjustments 14 System adjustments 15 Servicing requirements 16 Energy efficiency (ErP) 16 Product support 16 For more information visit www.nu-heat.co.uk 3

System Ref: Every Nu-Heat system is a custom design. Please record your unique system reference number above for future use. Welcome Congratulations, you are the owner of a Nu-Heat warm water underfloor heating system, designed and supplied by Nu-Heat UK Ltd., the largest supplier of domestic underfloor systems in the UK. This manual is provided to help you understand how the system operates and the correct settings required to get the most from your heating. Nu-Heat did not install your system, therefore any installation matters should be referred to the contractor concerned. Please record the installer s details below. For more information on the operation of your system and also troubleshooting help, please visit the Nu-Heat website at nu-heat.co.uk. Installer details Company: Contact name: Contact telephone no.: Address: 4 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

About the Nu-Heat System Description Underfloor heating works by pumping warm water through special plastic tubing embedded in the floor. This warms the floor and maintains the room at a comfortable temperature. Benefits In particular, underfloor heating systems: Provide a more comfortable heated environment, Permit unlimited interior design options, Increase the useable space within a property. Moreover, all these benefits are available from a system which can be significantly less expensive to run than a conventional, radiator-based system. System startup Once your system has been commissioned it should be fully operational. To initially check that your system is turned on and working please follow these simple steps: Underfloor heating Locate the main components of your installation: the boiler, hot water cylinder, underfloor heating pump/optiflo manifold assembly(s), thermostats, timeclocks, underfloor heating wiring box. Electricity supply Ensure that the electrical installation is complete and that the heating system is turned on. The location of the main supply ON/OFF switch may vary but is often positioned next to the boiler. There may be additional switches located at each underfloor heating wiring box, which also need to be on. Water supply Ensure that the water is turned on ready for domestic hot water operation, check that a high flow of water is available from the cold taps. If there is poor flow or none at all, check that the stop-cock for the property is fully open. For more information visit www.nu-heat.co.uk 5

Operation Your underfloor system is designed for performance and economy. Each heating zone is controlled by its own wall-mounted thermostat. If a room has no thermostat it will be connected to, and controlled by, an adjacent zone. UNDERFLOOR HEATIN Dial thermostats are timed using the four-channel timeclock. As supplied they will be set up such that when the timeclock is in an ON period the room will heat to the setting on the dial, but when the timeclock is in an OFF period a FROST PROTECTION temperature of 5 C will be maintained. Less thermally responsive floors, in particular screed floors greater than 65mm thick, will warm up more quickly when the thermostats are changed to operate in a setback mode. This means that when the timeclock is in an ON period the room will heat to the setting on the dial, but when the timeclock is in an OFF period a setback temperature, 4 C less than the dial setting, will be maintained. The mode can be selected on each thermostat individually, and is set by altering the DIL switches within the thermostat. See page 6, noting the safety warning. The best way to find the optimum temperature setting is to set a low comfort temperature on the dial (e.g.18 C) and then turn it up by 1 C each day until the temperature is right. Consideration should be given to the different floor constructions and finishes used in your property, as these factors will affect the time the system will take to achieve comfort conditions. Allowance should be made for switching the system on in time for the floor to reach comfort conditions by the desired time. Different areas of the property may be linked to different channels on the timeclock (see page 7 for details), but for each of these the timings should be set to account for the slowest-responding room. 6 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

Systems with dial thermostats & timeclock Dial-type room thermostats offer a straightforward method of controlling room temperature. The system will be timed by a multi-channel timeclock, and different channels may have been used for different areas of the property. The dial thermostats have two possible operating modes that affect how they respond to the timeclock: Thermostat mode: ON/FROST (default) Thermostat mode: ON/SETBACK (see page 9) TIMECLOCK ON Thermostat will maintain the temperature set on the dial. Thermostat will maintain the temperature set on the dial. TIMECLOCK OFF Thermostat is in Frost Protection mode. Thermostat will maintain a setback temperature 4 C below the temperature set on the dial. The default thermostat mode is ON/FROST. Setback is required only for rooms with floors that prove slow to heat up. THE EFFECT OF SETBACK (for illustration only) 20 C 15 C 16 C set-back 20 C early morning 16 C daytime 20 C evening 16 C set-back 10 C 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 Midnight Midday Midnight For more information visit www.nu-heat.co.uk 7

Operating instructions for the standard dial thermostat Call for heat = red Setback = yellow Normal = green * If the red light is flashing it indicates that the thermostat is calling for heat but the floor sensor has reached its limit. 3-position slide switch Up: (1) ON Mid: (timed) º Down: (0) OFF Turn dial to set temperature 3-POSITION SLIDE SWITCH ON: With the switch in the up-position (1) the thermostat will override the timeclock and the temperature set on the dial will continue to be maintained. This can be used to extend the heating period without the need to adjust the timeclock program. TIMED: With the switch in the mid-position (º) the thermostat will respond to the timeclock. Depending on how the thermostat has been set up at commissioning it will operate in either ON/FROST or ON/SETBACK mode (see p.7 for details). OFF: With the switch in the down-position (0) the thermostat will be essentially off and will not maintain comfort conditions but will, however, provide frost protection. LEAVIN THE BUILDIN UNOCCUPIED If the building is to be left unoccupied for a short period, this is managed by the HOLIDAY mode on the timeclock. Individual thermostats will enter SETBACK or FROST mode according to their settings. If the building is to be left unoccupied for a long period, slide the switch on all thermostats to position 0 (OFF with frost protection). All thermostats will enter FROST PROTECTION mode 8 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

SENSORS The heating system must be turned off and electrically isolated before changing sensor switch settings. Each thermostat has six sensor operation modes. These can be selected using switches 1-3 accessible from the back of the thermostat, after removing the front panel from the wall. Internal air sensor: Uses the built in air sensor only. Set switches 1 to 3 OFF Remote air sensor (if installed): Uses the remote air sensor only. Set switch 2 ON, switches 1/3 OFF Internal air sensor & floor limiting sensor (if installed): Uses the built in air sensor but also uses the remote floor sensor to ensure the floor temperature doesn t exceed a chosen limit. Should the floor temperature be exceeded (even if the desired room temperature has not) the heating will turn off. Floor temp. limit Applies to: Set switch 1 on, switches 2 and 3 OFF 25 C Most bamboo floor coverings* Set switch 1 and 3 ON, switch 2 OFF 27 C Most wood or vinyl floor coverings* Set switch 1 and 2 OFF, switch 3 ON 29 C eneral limit for bedrooms and living areas Set switch 1, 2 and 3 ON 32 C Limit for bathrooms and en-suites * Subject to the approval of the flooring supplier. HEATIN OPTIONS Each thermostat also has two control modes, selected using internal switch 4; this can be accessed inside the thermostat after removing the front panel. Thermostat to be SET-BACK by 4 C when the timeclock dictates an off period. Set switch 4 to ON. Thermostat to be in FROST PROTECTION mode when the timeclock dictates an off period. Set switch 4 to OFF. For more information visit www.nu-heat.co.uk 9

Operating instructions for the timeclock ZONES The timeclock can independently control 4 time zones, normally allocated as follows: 1 Time zone 1: e.g. round Floor 2 Time zone 2: e.g. Bedrooms 3 Time zone 3: e.g. uest rooms, etc. 4 Hot water time control Note: Rooms are allocated to time zones during installation. SETTIN THE CLOCK The timeclock is 24 hour. To set it, follow these steps: 1 From the main menu, press CLOCK. 2 Use the 6/5keys to set the hour. 3 Use the 6/5keys to set the minute. 4 Press DAY repeatedly to set the day of the week. 5 Press DONE to store. PRORAMMIN A HOLIDAY The timeclock can be programmed to switch all time zones to setback or frost protection mode for a set number of days ideal for when you are going away. To use the HOLIDAY function, follow these steps: 1 From the main menu, press HOLIDAY. 2 Select the number of days you are going away for. The holiday will start immediately, but will count tomorrow as the first day. 3 To cancel the holiday early, reduce the holiday days to 00 and press DONE. Note: If a domestic water cylinder is out of use for a number of days, a hygiene purge should be performed before use. NORMAL RUN MODE In normal RUN mode, the timeclock will display the current time. It can also be set to show the status for a particular time zone. To display the status of a time zone, press ZONE 1 ZONE 4. This screen will be displayed until you press DONE and return to the main menu. SELECTIN 5/2 OR 7 DAY PRORAMMIN Each Time zone can be programmed to work in 5/2 (Weekday/ Weekend) or 7 DAY mode. To setup the required mode, follow these steps: 1 Press ZONE 1. 2 Press DAY. 3 Set 00 to work in 5/2 day mode. 4 Set 01 to work in 7 day mode. 5 Press DONE. 10 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

ADJUSTIN THE SWITCHIN TIMES Each time zone has 4 ON/OFF times. Follow these steps to program the switching times: 1 Select the time zone you wish to program, for example ZONE 1. 2 Press EDIT. 3 If the time zone is operating in 5/2 day mode, you will see Mon,Tue, Wed, Thu, Fri on the display. If it is operating in 7 day mode, you will see Mon. 4 Press DAY to select the day to program. 5 You can now set the ON time by using the 6/5keys. If fewer switching times are required they can be ignored by setting to --/-- using the 6/5keys. 6 Press OFF, and set the OFF time. 7 Press button for Time 2, Time 3 and Time 4. 8 Press DAY to programme the other days, repeating from stage 5. 9 Press DONE to store. MODE SELECT Each time zone can operate in 3 modes: AUTO: The time zone will work to the programmed switching times. OFF: The time zone will switch off putting the thermostat into setback or frost mode. CONSTANT: The time zone will stay on. To set the mode for the time zone, follow these steps: 1 Select the time zone you wish to program, for example ZONE 1. 2 Repeatedly press MODE until the desired mode is displayed. 3 Press DONE to store. BOOST FACILITY Each time zone has a boost facility allowing you to turn it on for a number of hours. This is ideal for when you need to extend the time period but do not wish to reprogram the time clock settings. To use the BOOST facility, follow these steps: 1 Select the time zone you wish to program, for example ZONE 1. 2 Press BOOST. 3 Enter the desired boost period (in hours). 4 Press DONE. 5 The remaining boost time will be displayed on-screen. 6 To cancel the boost early, repeat the steps above reducing the boost time to 00. COPY FUNCTION The timeclock has a copy function, enabling you to copy switching times from one time zone to another. To use the COPY function, follow these steps: 1 Select the zone and press EDIT. 2 Press COPY. 3 Select each time zone you want to copy to and press DONE. CLEANIN Before cleaning the screen of the timeclock, press SCREEN to disable all functions for 15 seconds. While the countdown timer is showing the screen can be cleaned without activating any functions. For more information visit www.nu-heat.co.uk 11

eneral system checks The expansion vessel and filling loop is usually positioned near the boiler. Adjust the temperature of the boiler water by turning the boiler control thermostat. Never set the boiler water temperature lower than the cylinder thermostat. SYSTEM PRESSURE The majority of heating systems are sealed and include an expansion vessel which maintains the system pressure. This red vessel would normally be found positioned near to the boiler. If you have a combination boiler or system boiler the main pump and expansion vessel will be inside the boiler. The best way to identify this is that the boiler will have a pressure gauge on its panel. You will need to check the system pressure regularly as it is normal for a system to lose a small amount of pressure. The gauge should read approximately between 1 and 2 bar depending on whether the system is cold or hot. If the pressure is below 1 bar, top the pressure up to 1 bar by opening the valve on the filling loop connected to the red vessel (or boiler if no red vessel is visible). Only top up when the system is cold. If your system rapidly looses pressure you need to consult a heating engineer. If there is no red expansion vessel or gauge on the boiler then your system is not sealed but open vented and will be topped up automatically by a feed tank and ballcock in the loft. BOILER THERMOSTAT The temperature of water generated by your boiler is altered by adjusting the boiler control thermostat dial. If you have a hot water cylinder it is important that the boiler water temperature is always at least 5 C above the temperature of your cylinder thermostat. 12 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

1 1 3 3 6 6 eneral sequence of operation Every time heat is required in a room the following sequence is initiated: If the heating is in an ON period and the room requires heating, the room thermostat will call for heat: 1 A red LED light will appear on the thermostat. The floor pump, either on the Optiflo manifold serving that zone, or on the remote-mounted pump module will be switched on. The actuator on the Optiflo manifold circuit connected to the zone will open, indicated by the button on top of the actuator head rising. The flow gauge on this circuit will indicate flow and the flow pipe will get warm. Over a period of time as the room comes up to temperature, the return pipe will warm up as well. For standard systems with conventional boilers/cylinders or combination boilers the boiler and boiler pump are turned on to supply and circulate heat. MANIFOLD COMPONENTS 1 4 1 2 Flow gauges Flow temperature gauge 2 3 3 Flow adjustment 4 5 Pressure gauge Filling/drain off valve 9 6 Actuators 5 7 Manual air vent 8 Return temperature guage 9 Floor heating pump (direct mounted) 10 Main isolating valve (return) 11 Main isolating valve (flow) 12 Temperature blending valve 10 12 8 6 7 Note: Pump may be mounted directly or installed remotely. 5 11 For more information visit www.nu-heat.co.uk 13

Seasonal adjustments Underfloor heating can be left active all year round as it is thermostatically controlled by the room temperature. In warm weather it will simply not come on. If you require to turn the heating off (for example when servicing) always use the main heating isolation switch. LEAVIN THE PROPERTY UNOCCUPIED IN WINTER Rather than turning the heating system off, it is possible to leave background heating on as frost protection. Each room/zone can be set to frost protection individually. Please refer to the instructions (Leaving the Building Unoccupied on page 8), which detail how the thermostat can be put into FROST PROTECTION mode. INSTANT HOT WATER AND HEATED TOWEL RAIL Hot water and heated towel rails will be available all year round regardless of your requirement for underfloor heating (systems with EnergyPro hot water loop). 14 For expert advice call us on 01404 549770 or Freephone 0800 731 1976

System adjustments If additional heat is required in a selected room or rooms the water flow rate(s) serving these areas can be increased. a b c To do this: When the system is operating, turn the thermostat up in that room. Identify from the pipe markings at the manifold which actuator head serves the zone you want to change. Note: If the zones are not clearly marked turn off all the other room stats. The zone that is operating will be shown by a raised button on the top of the actuator (a) and the flow gauge will indicate a flow reading (b). Please note that the button can take up to 3 minutes to respond. Turn the flow gauge anti-clockwise for more flow, clockwise for less. The red flow indicator will drop further the greater the flow rate. Note: Adjust a little at a time to suit your requirements. Increasing the flow to one zone may decrease the flow to others. There is a limit to how much extra flow can be achieved and if, after adjusting one or several zones, further action is required the flow temperature can be increased. To do this:- With the system running note the water flow temperature on the gauge (c) on the top rail of the manifold. This temperature can be increased (see d1 and d2 below). Note: Adjust a little at a time to suit your requirements. d1 d2 Press to accept +/- +/- Remote pump module (d2) To increase the temperature: 1 Push the button above the illuminated display in and across to the right to scroll to the temperature menu. 2 Adjust the temperature by pushing the button to the left or right. 3 Press the button again to confirm the change. Direct-mounted pump module (d1) To increase the temperature: 1 Turn the control head anticlockwise For more information visit www.nu-heat.co.uk 15

Servicing requirements ENER FICIENCY EF TIN RA Y Y FICIENCY EF The DS thermostat is rated as Class I under Section 5.2.1.2 Temperature control, of EU Commission Delegated Regulation No. 811/2013. Product support For further information on the operation of your underfloor heating system and troubleshooting help, please visit the Nu-Heat website at nu-heat.co.uk. Online www.nu-heat.co.uk Follow us @nuheatuk See our videos /nuheatuk Freephone 0800 731 1976 or 01404 549770 Nu-Heat UK Ltd I Heathpark House I Devonshire Road I Heathpark Industrial Estate I Honiton I Devon EX14 1SD Y FICIENCY EF E TIN RA Energy efficiency (ErP) CLASS FICIENCY EF ENER ENER CLASS Y TIN RA TIN RA D TIN RA Please refer to eneral System Checks (page 12) for further information. Underfloor heating Whilst there is no requirement for annual servicing it is important that the level of central heating inhibitor is FICIENCY sufficient FICIENCYto protect the system. EF EF Y Y ENER Check the expansion vessel water pressure as displayed on the gauge, the pressure should normally be between 1 bar and 2 bar depending on whether the system is cold or hot. ENER ANNUALLY ENER MONTHLY