AT E X Ventilation and Air Conditioning in Explosive Areas

Similar documents
All-in-One: Packaged Air Handling Units

Air Handling Systems for Stores

Dual certification! Air handling units for potentially explosive atmospheres

AIR HANDLING UNITS MANDÍK

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

OPTIBAR DP 7060 Supplementary Instructions

Fire dampers. For diverse applications

Compact. Efficient. TROX.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

ATEX, NOMENCLATURE AND CODING

OPTIBAR P 1010/2010 C Supplementary instructions

EtherCAT Box Modules (EPxxxx-xxxx)

TRASCO ATEX Couplings

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

ANNEX GD-CERT-EX-EN SIT

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Implementation of ATEX Guidelines

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

ATEX Safety Switches. More than safety.

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

When you think safety think Systemair

Vacuum Hose Reel 881 Ex

ATEX, NOMENCLATURE AND CODING

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

The power of ventilation

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Technical Ventilation

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

[ TECHNOLOGY ] and does this definition affect a burner.

Certified drive and control products for explosion protection

1. GENERAL TECHNICAL INFORMATION

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

NEW ENGINEERING GUIDELINE (VDI 2263 PART 7) ON DUST FIRES AND EXPLOSIONS PROTECTION IN SPRAY DRYING AND INTEGRATED EQUIPMENT

Air Handling Units. Geniox. Quick guide

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Drive systems for the chemical, oil and gas industry. Electric drives and systems

SIHI dry Dry running vacuum pumps

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

ATM Lighting sp. z o.o

Beamex. Calibration White Paper. Calibration in hazardous areas

Compact. Efficient. TROX.

ATEX 137. What it means for motor users

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Manual Power relay SR853

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Operating Instructions for Rotor flow Indicator. Model: DKF

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units

Operating Instructions ATEX - Plug fans (Translation of the original) II 2G c IIB(+H2) T4 BA-CFD-RLM-ATEX /2015 RLM E6 RLM E3 RLM G6

Explosion Protection Enclosure with integrated measuring system

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

SMART WAY TO HANDLE THE AIR

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Beamex Calibration White Paper. Calibration in hazardous areas

OPTIWAVE X500 Supplementary Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Ex Products Highest level of safety under the most difficult conditions

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Copy Right By: Thomas T.S. Wan

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Centeral Station Air Handling Unit

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Translation of the assembly instructions with operating instructions and technical appendix

Safety instructions VEGAPULS 64

ATM Lighting sp. z o.o

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

The Nilfisk range of ATEX-certified vacuum cleaners

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

TKM 50 HE. High efficiency in air treatment

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

Operating instructions for HAWE devices

Multipoint temperature sensor

WPA-S-N/Ex. Use and Maintenance Manual. Explosion proof stationary fan. II 2 G c Ex e II T3. ATEX marking:

- SAFETY MANUAL - DAMPERS

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Miretti DetEx. the active core of Zone 2 Ex-Proof Conversions. Miretti DetEx enables your employees to work in safety

Explosion-protected actuator Page 259 of 292

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

C 319/6 Official Journal of the European Union

DAIKIN Air Handling Unit Modular

Technical Data. Dimensions

Transcription:

AT E X Ventilation and Air Conditioning in Explosive Areas

Application in explosion area 1 ATEX. When the Air Gets Dangerous. The ATEX directives oblige consultants, contractors and users to provide personal and property protection from explosion hazards. Sometimes, even air is dangerous. More often than one imagines, mixtures of air and inflammable substances, such as gases, vapours, mists or dust arise under atmospheric conditions. If a potential ignition source such as friction, electrical discharge or heat is present, there is the risk of an explosion. These atmospheric conditions are summarised in the acronym ATEX standing for atmosphères explosibles. Atmospheres which can become explosive (exatmospheres) may be present during normal operation or in case of accidents or failures. It may be present during normal operation in cases where inflammable substances are stored, conveyed, processed, filled, decanted, used for cleaning, production or are generates in the production process. Ex-atmosphere may arise where adhesives or paints are drying out, in the vicinity of fermentation tanks or where substances are being grounded. In breakdowns, explosion atmospheres can arise where defects occur for example in case of defective gas lines, unprotected openings of an outlet valve or leaks in a boiler. In industrial sectors, where chemicals and gases are handled, such as laboratories, chemical and petrochemical industries, power supply companies as well as waste disposal and recycling operations one can, as a rule, assume that ex-atmospheres may arise. The overall responsibility for the safety of buildings and its facilities is down the builder and the operator. Since 2003 European law makes compliance compulsory under Directive ATEX 137 for operators and under ATEX 95 for manufacturers, and regulates which measures are to be planned in order to avoid hazards. This gives a clear basis for design, implementation and operation. Where an ex-atmosphere is concerned, room air conditioning units stand out with regard to hazard potential, as the atmosphere flows through them or surrounds them and they contain certain components that are potential ignition sources. robatherm is one of the few manufacturers of AHUs who have experience of ATEX and who design and build units that comply with ATEX 95 and which have an ATEX-declaration and a TÜV-confirmation. ATEX stands for Atmosphères Explosibles, atmosphere capable of exploding. ATEX Directives describe measures for explosion protection. ATEX Directives are binding on operators, planners and manufacturers. ATEX 137 covers regulations for plant operators. ATEX 95 covers regulations for equipment manufacturers.

2 Putting it into practice ATEX Conformity. In Practice. Advisers, factory inspectorates, health and safety authorities as well as the TÜV support analysis, design and implementation. The installation conditions determine the category of the AHU required. Explosion group and temperature class are determined by the gases occuring. AHUs are subjects to the Machine Directives. In addition, they need to comply with the ATEX regulations, if: Ex-atmosphere can arise in the room where the unit is installed and/or Ex-atmosphere is handled. AHUs are not applicable for: Dusty atmospheres (Unit category 1D, 2D or 3D; i.e. Ex-Zone 20, 21 or 22), since AHUs are not dust removal facilities in the meaning of VDMA 24180. Unit group I, i.e. use in underground operations in mines with firedamp. Unit group 1G (ex-zone 0), since two independent protection devices shall be effective (e.g. an ATEX unit additionally encased in a concrete box). The classification of AHUs comes from the installation location here it is key whether the AHU is installed inside or outside the exzone (see figure) the gas explosion group and the temperature class. A differentiation is made between the ex-zone inside and the ex-zone outside. If the unit is assembled inside the ex-zone, there are ex-protection requirements in- and outside the unit. In case, it is assembled outside the ex-zone, the medium handled dictates the requirements. Carry-over of ex-gases e.g. through unit s doors needs to be considered. Back flow of air during shut off periods needs to be avoided at all costs, e.g. by air tight dampers. As a matter of principle, the two categories (ATEX zones) inside and outside must not differ by more than one class. Where no external ATEX zone has been defined, the operator shall ensure sufficient ventilation of the installation Ex-zone (according to DIN 50281-1-2) Ex-zone 0 Ex-zone 1 Ex-zone 2 Ex-atmosphere occurs constantly Ex-atmosphere occurs occasionally Ex-atmosphere occurs seldomly Disposition and category of unit Supply air Unit inside 2G 3G 2G, 3G* 3G, n.r.* 2G, n.r.* 3G, n.r.* Unit outside 2G 3G 3G n.r. n.r. n.r. Extract air Unit inside 2G 3G 2G 3G 2G 3G Unit outside 2G 3G 3G n.r. n.r. n.r. Ex-zone 1 N Ex-zone 2 N No ex-zone N Exterior area N * Back flow prevented n.r. = no requirements

Putting it into practice 3 II Classification of robatherm units I I 2 G I I B - T 4 Unit per ATEX Directive 94/9/EU EU conformity certification TÜV Süd TPS 05 ATEX 2 128 X II for Unit Group II 2 2 for Unit Category 2 or 3 G IIB T4 G for G = gas IIB for gases of Explosion Group IIA or IIB T4 for gases of Temperature Group T1, T2, T3 and T4 space so as to prevent the formation, during normal operation, of potentially explosive atmospheres due to leakages. Rooftop units which are usually surrounded by normal atmosphere (no ATEX zone) posing no explosion hazard are an exception. The results of a risk analysis, evaluation of the ignition hazard, unit description, calculations and tests have to be demonstrated. Applying ATEX 95 to AHUs, secondary explosion protection is the highest priority. The objective of these measures is to prevent ignition. Ignition sources can be either mechanical, e.g. by friction of the fan impeller on the inlet nozzle, or electrical at switches. Copper inlet nozzles and ATEX conforming electrical installations provide some remedy. Another problem is static loading, e.g. on droplet separator profiles, inspection glasses or flexible connections. 2G surface restrictions apply to plastic parts. All parts shall have a metallic connection or contact to the grounded unit base frames. A qualified lightning protection system shall be installed to protect against lightning strokes. Further potential ignition sources are hot surfaces on components, such as fan bearings, motors, air heaters etc., were the surface temperature needs to be correspondently limited. ATEX units are fitted with filters of at least Class F5 at the unit intake to avoid ignition sources arising from dust accumulation, if they are not operated with fine dust filtered air. Units per ATEX Directive Unit group I II Classification and identification Unit category Atmosphere D = dust, G = gas Explosion group AHUs are not designed for use underground 1 Only with second protection device 2 3 D G D G Temperature class Not for dusty atmospheres IIA IIB IIC T1 - T4 Not for AHUs Not for dusty atmospheres IIA IIB IIC T1 - T4 Not for AHUs

4 robatherm solutions Modular and Flexible. robatherm Solutions. Certified safety without compromising flexibility, economy, hygiene or controllability. Flexible configuration, variable dimensions. Based on the robatherm modular AHU programme, ATEX units have been designed with TÜV certified Outstanding energy efficiency. protection provisions which are perfectly adapted to the requirements of the respective ATEX units, equipped with high standard components, EU Type tested according to the ATEX Directive. Excellent hygiene, maintenance friendly and easy to clean. application. ATEX units are available in the following designs meet the highest energy efficiency classes according to both, the RLT Regulation 01 of the German Association Constant quality and safety of ATEX units are guaranteed by individual tests Integrated control technology. Interior units Weatherproof units Units meeting extended hygiene demands. of Manufacturers of Room Air Conditioning Units and the European certification agency EUROVENT. This guaranties and independent external inspections by the TÜV. This emphasises our professional approach. Tested safety. The outstanding energy effi- efficient operation and lowest life cycle cost. If it comes to hygiene, mainte- ciency of robatherm units is Inside the ex-zone we only use nance friendliness and ease not at all affected by the ATEX sensors, actuators and further of cleaning, ATEX units meet configuration. electrical equipment which is the wellknown level of all

robatherm products. All hygiene characteristics are evaluated and testified by the Institute of Air Hygiene (ILH) in Berlin. Casing The modular casing design covers the capacity range from 1,000 to 320,000 m 3 /h. Height, depth, and length are based on the modul s dimension of 102 mm. The properties of the casing are TÜV tested. The numbers for heat transmission, thermal bridges, housing leakages and others are outstanding. A conductive powder coating or stainless steel ensures a high protection against corrosion and a long lifetime. The physical properties of the unit s casing are according to DIN EN 1886: Heat transmission: Class T2 Thermal bridges: Class TB2 Leakage: Class L1 (M) Filter bypass leakage: Class F9 Casing deflection: Class D2

6 Detail description Convincing Details. Seamless integration: Components according to ATEX Certified components for every configuration. The use of especially designed components is a pre-supposition to keep the conformity to the ATEX High reliability. directive. Flexible connectors The flexible connectors Air filters Air filters have conductible Flexible configuration. Grounding of the unit To avoid any static loading, all parts are grounded and special conductible powder are made from conductible material. Each connector comes with an equipotential bonding. filter media (Filter Class G3 to H13). The filter frames are powder coated. Stainless steel is available as an option. Tested safety. coating is used. (RAL colour 7024).

Detail description 7 Fans Direct driven plug fans with horizontal or vertical axles, as well as direct or belt driven spiral housing fans are available. Spark formation is positively prevented by special material pairing for fan propellers and fan intake nozzles. Belt driven fans are equipped with conductive drive belts. Motors are protected against explosions with enhanced safety: each has a EU type test certificate according to the ATEX Directive. Droplet separators Droplet separators are removable for cleaning, mounted in extractable stainless steel frames and have conductive aluminium profiles (2G). Dampers Dampers with blades, mounted in brass bearings.the grounded blades are interconnected with gear wheels or outside levers. As a standard, the dampers meet Tightness Class 1 to 4 according to DIN EN 1751. Silencers The silencers are covered with fibreglass and perforated metal sheet preventing abrasion and static loading. Heat recovery systems Special plate heat exchangers with ATEX-compliant bypass dampers, or closed-circuit systems for separate airflows to prevent leakages and any carryover between zones. Heat exchangers are electroconductive. Switch/Lights Lighting, repair switches and the entire light installation is according to ATEX directive. Only certified components are used.

8 References Best Choice. Best References. Trust and confidence emerge from quality. That is why many well-known companies favor robatherm s solutions. Automobile Industry Chemical and Pharmaceutical Industry Commercial Building Electronic Industry Hospital Production Automobile Industry Alfa Romeo, Audi, BMW, Bugatti, Citroen, DaimlerChrysler, Ford, General Motors, Honda, Iveco, John Deere, KIA, Michelin, Opel, Peugeot, Porsche, Renault, Rover, Scania, SEAT, Skoda, Suzuki, Toyota, Volkswagen, Volvo Chemical and Pharmaceutical Industry 3M santé, BASF, Bayer, Beiersdorf, Boehringer, BP, Degussa, Du Pont, Fraunhofer Institut, Fresenius, Glaxo Smithkline, Höchst, Institut Pasteur, Krupp, Linde, L Oréal, Labo Piette, Merckle, Mérial, Osram, Pfizer, Procter + Gamble, Roche, Sanofi, Schering, Solvay, Thomae, Urenco Commercial Building Allianz, Commerzbank, Crédit Agricole, Deutsche Bahn, Deutsche Bank, Disneyland, Dresdner Bank, ECE, H&M, IKEA, Interspar, Mediamarkt, NATO, RWE, SAP, Semperoper Dresden, Flughafen Tel-Aviv, TU Dresden Electronic Industry Acer, Alcatel, Altis, AMP, Bosch, BSH, Corning, Epcos, Hewlett Packard, Hitachi, IBM, Intel, Max-Planck-Institut, Microchip, Motorola, NS Electronics, Osram, Philips, Q-Sells, Radiall, Siemens, SIGMA, Soitec, Sony, STMicroelectronics, Texas Instruments, THAI CRT, Thales, Toshiba, Tower, TSMC Hospital Beijing Hospital, Guangxi Hospital, Hôpital Saint Joseph Paris, Isarklinik München, Jilin Hospital, Klinika Moskau, Shanghai Hospital, St. Louis Hospital, Universitätsklinik Essen, XinHua Hospital Shanghai, Zhengzhou Hospital Production Airbus, Arcelor, Carl Zeiss, Coca Cola, Conergy, Continental, EADS, EON, Eurocopter, Ferrero, Hartmann, Hilti, Liebherr, Mc Donalds, MAN, Nestlé, Philip Morris, Thyssen Krupp, Trumpf, Vaillant, Viessmann, Voith, Wanzl.

robatherm accepts no responsibility or liability for the correctness or completeness of the contents of this document. Figures and descriptions to some degree contain elements that exceeded those in the standard product. Subject to technical modification and amendment. Edition 07/2011. Copyright by robatherm.

Industriestrasse 26 89331 Burgau Germany Tel. +49 8222 999-0 Fax +49 8222 999-222 www.robatherm.com info@robatherm.com