Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Similar documents
Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Thermostatic valves with radiator connection systems

Multilux 4-Eclipse-Set

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

thermostatic valve body with stepless precision presetting

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

IMI Heimeier Kit Hydroca ble

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Mikrotherm. Manual Radiator Valves With presetting

Control valves for floor heating systems. Floor Heating Manifolds

Standard. thermostatic valve body without presetting

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Thermostatic valve bodies

Three-way reversing valve

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Thermostatic valve bodies

Flush individual room control for floor heating systems

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Regulux. Radiator lockshield with drain-off facility. To be precise.

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Halo. Thermostatic heads with built-in sensor

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

thermostatic inserts for radiators with integrated valves

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Art-Line. Absolutely Brilliant Temperature control was never so good

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

HERZ Regulating valve 4002

Globo H. Ball valves Gunmetal ball valve

HERZ Differential Pressure Control Valve 4002

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Automatic balancing valves ASV-PV (new generation) DN 32-50

Installation and operating instructions

Meet Max. Unique AFC technology

TS RD 7761 RD, 7761 RD

manifold, for radiators

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Energy Saving Series RADICAL

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Measuring instruments for hydraulic balancing

Dynamic thermostatic radiator valves DYNAMICAL

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Radiator Trap Radiator Valve

RA2000 Commercial TRVs

TA-Compact-P. Giving you MORE by giving you LESS

AVTI Multifunctional self - acting controller

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Radical CPD BIM.

Radiator Valve Program

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

Problem-solvers The Radiator Solution Range

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Valves, controls + systems Flow, pressure and temperature balancing

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

Say heating. Say Herz. HERZ-Supply Engineering

2 DESCRIPTION OF SYSTEM COMPONENTS

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

EMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.

SOLUTIONS GUIDE. For total efficiency

RA 2000 Series RA 15/6T & TB Conversion Valve

SAUTER Valveco compact. A pressure-independent multi-function valve

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

Transcription:

Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic radiator valve Eclipse has a unique integrated flow limiter that eliminate over flows. The required flow rate can be adjusted directly at the valve with a twist. The adjusted flow will not be exceed even if there are load changes in the system, due to other valves closing or during morning start up. The valve controls the flow rate independently from differential pressure. Therefore, complicated calculations to determine settings are not necessary. Key features > > Integrated flow limiter Eliminates over flows > > Easy adjustment Just a twist to reach design flow > > Flow range from 0 to 0 l/h For high flexibility > > All valve bodies with II+ marking can be retrofitted as Eclipse i.e. Calypso exact, Calypso, Mikrotherm F, Multilux, Multilux -Set > > Perfect for renovation Standard dimensions and easy flow sizing Technical description Applications area: Heating systems. Function: Control Flow limitation Shut-off imensions: N 0-0 Pressure class: PN 0 Temperature: Max. working temperature: 0 C, with protection cap or actuator 00 C. Min. working temperature: -0 C. Flow range: The flow can be stepless pre-set within the range: 0-0 l/h. elivery setting 0 l/h. (Max. nominal flow q mn at 0 kpa concerning EN : 0 l/h) ifferential pressure (ΔpV): Max. differential pressure: 60 kpa (<0 db(a)) Min. differential pressure: 0 00 l/h = 0 kpa 00 0 l/h = kpa Materials: Valve body: Brass O-rings: EPM rubber Valve disc: EPM rubber Return spring: Stainless steel Valve insert: Brass, PPS (polyphenylsulphide) The complete thermostatic insert can be replaced using the IMI Heimeier fitting tool without draining the system. Spindle: Niro-steel spindle with double O-ring sealing. Surface treatment: Valve body and fittings are nickel-plated. Marking: THE, country code, flow direction arrow, N and KEYMARK-esignation. II+ esignation. Orange protection cap. Standards: Valve bodies meet the following requirements: KEYMARK certified and tested to IN EN. 0 Pipe connection: The female-threaded version is designed for connection to threaded pipe, or in conjunction with compression fittings, to copper or precision steel pipe. With double connection fitting suitable for compression fitting for multi layer pipes. Connection to thermostatic head and actuator: IMI Heimeier M0x.

Construction Eclipse. Strong return spring in combination with high locating force ensures that the valve does not slacken off over time. IMI Heimeier M0x. connection for thermostatic heads and actuators. EPM O-ring. Automatic flow limiter. Valve body made of Brass 6. Long-life double O-ring sealing 7. Flow setting Replaceable insert The complete thermostatic insert can be replaced using the fitting tool without draining the system. Function Eclipse flow limiter A regulating part is set to the calculated control rate by turning the digit cap with the setting key or an mm end wrench. If the flow rate increases at the valve the rising pressure moves the sleeve, thus constantly limiting the flow to the set value. The set flow rate is therefore never exceeded. If the flow rate drops below the set value a spring presses the sleeve back to its original position. Application The thermostatic radiator valve Eclipse is applied in two-pipe pumped heating system with normal to high temperature spread. The required design flow for each radiator is set directly on the Eclipse valve. This automatic flow limitation is done with a twist and the adjusted flow will then not be exceeded. Even if there is an oversupply of pressure, due to load changes in the system, for example other valves closing or during morning start up, Eclipse will guarantee the requested flow. The valve controls the flow rate independently from differential pressure. Therefore, complicated calculations to determine settings are not necessary. The pressure loss of pipings in old systems does not have to be determined in renovation projects. Only the heating capacity and the resulting max. flow rate have to be determined (see setting chart). The min. differential pressure has to be at the most unfavourable valve. If necessary, it can be measured in order to optimize pump settings (see accessories). Renovation All IMI Heimeier thermostatic radiator valves with II+ marking, i.e. Calypso exact, Calypso, Mikrotherm F, Multilux, Multilux -Set can be retrofitted as Eclipse. Noise behaviour To ensure low-noise performance, the following conditions must be met: The differential pressure above Eclipse should not exceed 60 kpa = 600 mbar = 0,6 bar (<0 db(a)). Flow must be correctly adjusted. The system must be completely deaerated.

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Sample application. Eclipse. Lockshield Regulux/Regutec. STA balancing valve for maintenance and diagnostics. Boiler Notes To avoid damage and the formation of scale deposit in the hot water heating system, the composition of the heat transfer medium should be in accordance with the VI guideline 0. For industrial and long-distance energy systems, see the applicable codes VdTÜV and 66/AGFW FW 0. A heat transfer medium containing mineral oils, or any type of lubricant containing mineral oil can have extremely negative effects and usually lead to the disintegration of EPM seals. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly concerning concentration and specific additives. Flush the system before changing thermostatic valves in heavy polluted existing systems. The thermostatic valve bodies can be used with all IMI Heimeier thermostatic heads and IMI Heimeier or IMI TA thermal or motorized actuators. The optimal tuning of the components guarantees maximum safety. When using actuators from other manufacturers, make sure that the pressure power is appropriate for thermostatic valve bodies with soft sealing valve discs. Operation Flow setting Stepless setting between to (0 to 0 l/h). The setting is changed using a special setting key (article No. 90-0.) or an mm end wrench, to ensure tamper proof setting. Place the setting key on the valve insert. Turn the setting tool so that desired setting value is pointing at the index* of the valve body (see fig.). Remove the key or mm end wrench. The valve is now set. Front-end and lateral visibility *) SW *) Index

Setting l l l l l l l 0 l l l l l/h 0 0 0 0 0 60 70 80 90 00 0 0 0 0 0 P-band [xp] max. K. P-band [xp] max. K up to 90 l/h. iagram l/h 60 db(a) 0 db(a) max. Lowest flow tolerances 0 0 00 80 60 0 0 min. 0 0 0 0 0 0 0 60 kpa 0 0 0 70 90 0 0 0 l/h 0-00 l/h: 0 kpa 00-0 l/h: kpa *) P-band [xp] max. K. Setting table Setting values with different radiator performances and system differential temperatures 0 6 7 8 9 0 6 7 8 9 0 0 6 7 8 9 0 0 0 6 6 7 8 8 9 9 00 0 6 6 7 7 7 8 8 9 0 p min. 0-00 l/h = 0 kpa p min. 00-0 l/h = kpa Q = Radiator performance Δt = System differential temperature Δp = ifferential pressure Sample: Q = 000 W, Δt = K Setting value: 6 ( 60 l/h)

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Articles H SW Angle l SW l l d N d l l l H Flow EAN 0 Rp/8 R/8 9 0 0-0 009 6-0.000 Rp/ R/ 6, 0-0 009 6-0.000 0 Rp/ R/ 0 6 6, 0-0 009 6-0.000 SW SW H l l d Straight N d l l H Flow EAN 0 Rp/8 R/8 0 76, 0-0 00960 6-0.000 Rp/ R/ 8, 0-0 00979 6-0.000 0 Rp/ R/ 6 97, 0-0 00988 6-0.000 SW Axial,0 N 0, N 6,0 N 0 H SW l l d N d l l H Flow EAN 0 Rp/8 R/8, 0, 0-0 00906 60-0.000 Rp/ R/ 6, 0-0 009 60-0.000 0 Rp/ R/ 0 6, 0-0 009 60-0.000 SW SW d N0 6 N ouble angle Connection to radiator left. Gunmetal. Suitable for compression fitting for multi layer pipes. l l N d l l Flow EAN 0 Rp/8 R/8 6 0-0 00909 9-0.000 Rp/ R/ 9 8 0-0 0097 9-0.000 N0 6 N d SW SW l l ouble angle Connection to radiator right. Gunmetal. Suitable for compression fitting for multi layer pipes. N d l l Flow EAN 0 Rp/8 R/8 6 0-0 0098 9-0.000 Rp/ R/ 9 8 0-0 009 9-0.000 *) SW: N 0 = mm, N = 7 mm, N 0 = mm SW: N 0 = 7 mm, N = 0 mm, N 0 = 7 mm Values H and H are at the bearing surface thermostatic head or actuator. 6

Accessories Setting key for Eclipse. Color orange. EAN 00977 90-0. for copper or precision steel pipe according to IN EN 07/00-/. Female thread connection Rp /8 Rp /. Metal-to-metal joint. Brass nickel-plated. Support sleeves should be used for a pipe wall thickness of 0.8 mm. Follow the specifications of the pipe manufacturer. Ø Pipe N EAN 0 (/8 ) 0076 0-. (/ ) 0077 0-. (/ ) 00707 0-. 6 (/ ) 0076 0-6. 8 0 (/ ) 007 0-8. Support sleeve for copper or precision steel pipe with a mm wall thickness. Brass. Ø Pipe L EAN,0 00706 00-.70 6,0 00797 00-.70 6 6, 0089 00-6.70 8 6,8 0088 00-8.70 ouble connection fitting For clamping plastic, copper, precision steel or multi-layer pipes. Brass, nickel-plated. L EAN G/ x R/ 6 0008 -.08 for copper or precision steel pipe according to IN EN 07/00-/. Connection male thread G / according to IN EN 6 (Eurocone). Metal-to-metal joint. Brass nickel-plated. With a pipe wall thickness of 0.8- mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Ø Pipe EAN 00 8-. 000 8-. 0067 8-. 6 009 8-6. 8 008 8-8. for copper or precision steel pipe according to IN EN 07/00-/. Connection male thread G / according to IN EN 6 (Eurocone). Soft sealed, max. 9 C. Nickel-plated brass. Ø Pipe EAN 008 -. 8 00606-8. for plastic pipe according to IN 76, ISO 008. PE-X: IN 689/689, EN ISO 87; PB: IN 6968/6969. Connection male thread G / according to IN EN 6 (Eurocone). Nickel plated brass. Ø Pipe EAN x, 00608 -. x 0068 -. 6x, 0067-6. 6x 0086-6. 7x 009-7. 8x 000-8. 0x 008-0. 7

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F for Alu/PEX multi-layer pipe according to IN 686. Connection male thread G / according to IN EN 6 (Eurocone). Nickel-plated brass. Ø Pipe EAN 6x 007-6. 8x 007-8. Fitting tool complete with case, box spanner and replacement seals, for replacing thermostatic inserts without draining off the heating system (for N 0 to N 0). EAN Fitting tool 00989 97-00.000 Replacement seals 009900 97-00. Measuring spindle for fitting tool for differential pressure measurement at thermostatic valve bodies with TA-SCOPE balancing instrument. EAN 009 9790-0.890 Replacement thermostatic insert with automatic flow limiter for Eclipse. EAN 00909 90-0.00 Other accessories, see catalogue leaflet Accessories and spare parts for thermostatic radiator valves. The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. Eclipse F EN ed. 0.07