Please read this manual carefully before installation and use.

Similar documents
ETN-24-SUPER-PROG (US Program - Celsius)

FMT24-SUPER-2S-FP-PROG-F Owner s manual & Technician Settings. Installation

ETN-24-HC21-PROG Econo-Vent

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

ETN-24-SUPER-SF Series

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Safety & Installation Instructions

T-32-TS Touchscreen Thermostat. Installation Manual

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

SC Installation, Operation & Application Guide

Programmable Thermostat

SAS6000UTK-7 UNIVERSAL THERMOSTAT

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Smart Temp. Model

ETN1000/MIGA - Operating manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

Smart Temp. ApolloP/n Installation Manual. Version 1.0

AMANA PHWT-A200 THERMOSTAT

Safety & Installation Instructions

OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Safety & Installation Instructions

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

SC Installation, Operation & Application Guide

CT2800 Programmable Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

OPERATING MANUAL. Need Help? This manual covers the following models: T755. Table of Contents

Underfloor Heating Programmable Thermostat

Commercial Touchscreen Thermostat

OPERATING MANUAL. Need Help? This manual covers the following models: T715. Table of Contents

SC Installation, Operation & Application Guide

P200 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

OPERATING MANUAL. This manual covers TopTech models: TT-S-755

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

ELECTRONIC COMMUNICATING THERMOSTAT

Set & $ave. Model Programmable Thermostat. installation and operation manual

SAT- 3 Installation Setup Guide

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

INSTALLATION & USER MANUAL

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

OPERATING MANUAL. Need Help? This manual covers the following models: T805. Table of Contents

For Quick Set-Up go to Page 14

Model: Touch-RF. 1 Wireless Series

MagicStat CT3300 Programmable Thermostat

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Programmable Thermostat

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Installation Instructions

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

Elegance. SMT-700 User manual. Ver

User s Manual

Model: PRT-TS / PRT-NTS

Model: Available in : Sapphire Black and Glacier White. 1 Series

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Safety & Installation Instructions

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

OWNER S MANUAL Venstar Inc. 08/07

Model: Touch-RS. 1 Touch-RS

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

GreenCon On/Off Room Thermostat

Technicians Manual Single Compressor

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Digital Programmable

GreenCon On/Off Room Thermostat

Model: Slimline-RF. 1 Slimline Series

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

OPERATING MANUAL. This manual covers TopTech models: TT-S-755H

Model: Slimline-N. 1 Slimline Series

OWNER S MANUAL Venstar Inc. 08/07

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

Rev This manual covers the following models: T771. Mounting and Battery Installation

OWNER S MANUAL Venstar Inc. 08/07

PRT-TS WiFi PRT-TS WiFi

INSTALLER S & OWNER S MANUAL

- Data Brochure tekmarnet 4 Thermostat 542e

INSTALLER S & OWNER S MANUAL

Transcription:

Doylestown, PA 18902 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: support@scillc.com - www.scillc.com FMT-24-SUPER-PROG With freeze protection Owner s Manual Installation and Operating Instructions Please read this manual carefully before installation and use. Index Options and accessories 1 Installation Instructions 2 Wiring Connections 3 DIP Switch Configuration and External Sensor Connection 4 Operating Manual 5 Technician Settings 6 Hand held remote control (RT04) 7 1. Options and Accessories Hand held remote control with weekly program. Individual cool and heat set points. External sensor option: RS01 for remote temperature sensing (1 required) RS02 for average temperature sensing (2 required) For details on where to purchase accessories, please contact SCI for your nearest location or visit our web site at www.scillc.com File: FMT-24-SUPER-PROG+FP_letter_rev1.doc Rev. 1 October 16,2007

2. Installation Instructions It is very important to find the right place to install the Flush Mount unit. Please make sure to follow all the installation instructions in order to get an accurate reading of the temperature. General points to follow: The unit MUST be fitted into a standard electrical box. The Unit must not be installed in the following cases: On an outside wall. When not having air draft inside. Exposed to direct sunlight. The standard height to install this unit is 5 feet (1.5 meter). Installation procedure: Disconnect quick connector from thermostat. Connect the wires (see wiring connections #3) Reconnect the quick connector back to the thermostat. Put the thermostat in the electrical box. Set the orientation as in the picture on the right. Tighten up the 2 screws. Adapt the front frame-panel into its place, by pushing it towards the wall. 2

3. Wiring Connections - please see # 4 If you have the super model, make sure that you choose the right configuration Factory) Rc-Rh - If one transformer is in use, Rc-Rh must be shorted - (Default from Table 3.1 - Connections for all applications Terminal Function ETN HC11 HC22 HP21 HP32 C 24VAC Common from transformer Rc 24Vac RED Rh 24Vac RED (jumpered to Rc) G Fan W2 Heating 2 nd Stage N/A (EMH) (EMH) W1 Heating 1 st Stage / Heat Pump Y2 Cooling 2 nd Stage N/A N/A Y1 Cooling 1 st Stage T External Sensor (option) T External Sensor (option) N/A Not Available (not in use) EMH emergency heat mode 3

IMPORTANT! Before making any changes in the dipswitch disconnect electricity in the main board. 4. DIP Switch Configuration and External Sensor Connection 4.1 DIP Switch Location The DIP switch is located on the top of the back side of the thermostat (above the connectors). 1 2 3 4 5 6 Default DIP switch from factory Table 4.1 DIP Switch Selection Switch Function ON OFF Default 1 Internal Sensor Control External sensor control OFF 2 With Heat Pump (HP) Without Heat Pump (HC) OFF 3 In HC mode: (Switch 2 OFF) In HP mode: (Switch 2 ON) Fan Control for Electrical Heat Fan Control for Gas/Oil Heat Heat Pump in COOL mode ( O ) Heat Pump in HEAT mode ( B ) OFF OFF 4 5 6 3 minutes delay for compressor No delay Internal Sensor Control External sensor control Internal Sensor Control External sensor control Use this table together with the illustration above showing the switch configuration. OFF OFF ON 4.2 DIP Switch Operation The DIP switch has 6 pins. Each pin can be ON or OFF. In the picture, pin 6 - ON and pins 1,2,3,4,5 OFF 1 2 3 4 5 6 4

4.3 External sensor connection - option Important! The external sensor must be SCI type. Table 4.4 - N.TC. Sensor: Temperature ~ Resistance Characteristics Temp C 7.2 10.0 12.8 15.6 18.3 21.1 23.9 26.7 29.4 32.2 Temp F 45 50 55 60 65 70 75 80 85 90 Res. k 115.8 100.9 88.1 77.1 67.7 59.6 52.5 46.4 41.2 36.6 The default from factory is INTERNAL SENSOR. 1. Disconnect power to the thermostat. 2. Move DIP switches 1,5 and 6 as shown in the picture below Switch 1 - ON Switch 5 - ON Switch 6 OFF 1 2 3 4 5 6 3. Connect the temperature sensor to T-T terminals. 4. Reconnect power to the thermostat. The wire length for the external sensor can be up to 100 feet (30 meters) with standard cable. If the distance is greater than 100 feet then it MUST be shielded type. There is a wide range of sensors for different applications, duct, rooms, etc. There are also options for averaging the temperature. For details please contact our technical line or visit our web site. 5

5. Operating Manual 5.1 On/Off Press the ON button to turn the thermostat ON or OFF - the word "ON" or "OFF" will appear on display. 5.2 Set Temperature Press the + or - buttons COOL will appear on display and the set temperature for cooling will flash. Adjust the set temperature for cooling using the + or - buttons. Wait 3 seconds HEAT will appear on display and the set temperature for heating will flash. Adjust the set temperature for heating using the + or - buttons. Wait until display returns to normal. 5.3 Mode, Fan speed, Auto Fan Press the SELECT button UnLo and the actual mode will appear on display. Using the + and - buttons switch between: Cool Cool will appear on display Heat Heat will appear on display Emergency Heat* E.Heat will appear on display Cool/Heat auto change over Both Cool and Heat will appear on display Fan Only Fan will appear on display *The Emergency Heat Mode is active only in heat-pump systems to prevent any harm to the compressor, while working in Heat mode in a very low outdoor temperature (beneath 32ºF). Press the SELECT button again Fan or Auto Fan will appear on display. Using the + and - buttons switch between: Fan on the fan will work continuously Fan will appear on display. Auto fan* the fan will work when there is demand for cool or heat Auto Fan will appear on display. *Auto Fan is not available when the mode is set to Fan Only mode. 6

* In Heat mode, with Oil/Gas heat configuration (i.e., furnace): AUTO FAN - Fan will never be activated. FAN ON - The Fan will work continuously. Press the ON button to return to normal display. 5.4 Lock/Unlock the thermostat button Use the Lock option to prevent users from making unwanted changes. When the thermostat is locked, the SELECT button and the + and - buttons do not work. However, the users can turn the thermostat ON or OFF. The display will alternate between Loc and real time clock. Make sure both temperature set-points are different than 50ºF. Lock the thermostat - Press and hold the SELECT button (20 seconds) until Loc will appear on display. Unlock the thermostat - Press and hold the SELECT button again (20 seconds) until UnLo will appear on display. 7

5.5 Programming The thermostat is a 5-1-1 programmable; weekdays Monday through Friday, Saturday and Sunday both have individual programs. There are four program events per day: 1-Wake, 2-Day, 3-Return, 4-Sleep Switch between Programmable/Non Programmable configurations Press and hold the ON button (10 seconds) The word Program will either appear on display or disappear from display. When the word Program appears on display, the weekly program is enabled and can be modified. When the word Program does not appear on display, the weekly program is disabled and cannot be modified. Programming defaults from the factory. Monday to Friday 1 (Wake) 2 (Day) 3 (Return) 4 (Sleep) Start time 6:30 AM 8:00 AM 5:30 PM 10:00 PM Cool Set Point 78 F 85 F 78 F 82 F Heat Set Point 70 F 62 F 70 F 62 F Saturday 1 (Wake) 2 (Day) 3 (Return) 4 (Sleep) Start time 7:30 AM 12:30 PM 6:00 PM 11:30 PM Cool Set Point 78 F 74 F 72 F 78 F Heat Set Point 70 F 70 F 70 F 65 F Sunday 1 (Wake) 2 (Day) 3 (Return) 4 (Sleep) Start time 7:30 AM 12:30 PM 6:00 PM 11:30 PM Cool Set Point 76 F 74 F 72 F 78 F Heat Set Point 70 F 70 F 70 F 65 F To exit the Program mode, press ON button until normal display is reached. If no key is pressed for 30 seconds, the thermostat will return to normal display. 8

Program Chart 9

6. Technician Settings 6.1 Adjust temperature limits for cool and heat, and offset for temperature reading. Set temperature to 50 F. Wait until the display Press and hold the SELECT button (5 sec.) COOL and the temperature limit for cooling will appear on display. Adjust the temperature limit for cooling (Limit Cool) using the + and - buttons. Press the SELECT button again HEAT and the temperature limit for heating will appear on display. Adjust the temperature limit for heating (Limit Heat) using the + and - buttons. (Limit Heat should be higher than Limit Cool). Press the SELECT button again the OFFSET temperature will appear on display (a number between 6 +6). The offset is used for calibration of the measured temperature. Adjust the Offset for ambient temperature reading using the + and - buttons. Press the SELECT button again to return to normal display. 6.2 Freeze Protection When the temperature drops below 45 F, the thermostat will turn on the Heat and Fan outputs in order to protect the system from freezing. This function will be activated when the thermostat is either in On or Off position. The Display will alternate between AL and TEMP The thermostat will return to normal mode when the temperature rises above 48 F. 10

7. RT04 - Hand Held Remote Control - Option The remote control is Infrared; the remote must be pointed at the thermostat to operate. Every time you change parameters in the Remote Control, you must send it to the thermostat by pressing the ON/SEND button. 7.1 On/Send, OFF Press the ON/SEND button to turn the thermostat ON and/or update information. Press the OFF button to turn the thermostat OFF and update information. 7.2 Fan Modes Press FAN button to change between: FAN ON ( ) or AUTO FAN (A). Press the ON/SEND button to send information to thermostat. 7.3 Modes Press MODE button to change between: COOL, HEAT, AUTO CHANGE and FAN ONLY. Press ON/SEND button to send the information to the thermostat. 11

7.4 Temperature Set Point In Cool Mode: Press the + or - buttons - COOL and set temperature for cooling will flash. Using the + and - buttons, adjust the set temperature for cooling. Press the ON/SEND button to send the information to the thermostat. In Heat Mode: Press the + or - buttons - HEAT and set temperature for heating will flash. Using the + and - buttons, adjust the set temperature for heating. Press the ON/SEND button to send the information to the thermostat. In Auto Change-over Mode: Press the + or - buttons - COOL and set temperature for cooling will flash. Using the + and - buttons, adjust the set temperature for cooling. Press the SELECT button HEAT and set temperature for heating will flash. Using the + and - buttons, adjust the set temperature for heating. Press the SELECT button again or Press ON/SEND button to send the information to the thermostat. 12

always less than Cool). The thermostat keeps a minimum differential of at least 1 degree between Heat set and Cool set (Heat is 7.5 Real Time Clock and Day Press the SELECT button CLOCK SET will flash. Press the + or - buttons - the hours will flash. Adjust the hours using the + and - buttons. Press the SELECT button again the minutes will flash. Adjust the minutes using the + and - buttons. Press the SELECT button again the weekday will flash. Adjust the day using the + and - buttons. Press the SELECT button again to exit the program or Press ON/SEND button to send the information to the thermostat. 7.6 Programming Set the Program times and Temperature settings for the week: The remote is 5-1-1 programmable: weekdays (Monday to Friday), Saturday, and Sunday can be programmed differently. 4 program events per day: 1 (Morning), 2 (Day), 3 (Evening), 4 (Night) The program can be set away from the thermostat and can be sent later on. To send the program to the thermostat, follow the steps below without adjusting times and temperatures. Only press the ON/SEND button each time the word SEND flashes on display (point the remote control to the thermostat) To enter programming, press and hold the SELECT button for three seconds - PROGRAM (flashing) and the days Mon-Fri will appear on display. 13

Press the + or - buttons, PROGRAM 1 & START (flashing) will appear on display. Press the + or - button - the hours will flash. Adjust the hours using the + and - buttons. 14

Press the SELECT button - the minutes will flash. Adjust the minutes using the + and - buttons. Press the SELECT button again COOL (flashing) & the set temperature for cooling will appear on display. Adjust the set temperature for cooling using the + and - buttons. Press the SELECT button again HEAT (flashing) & the set temperature for heating will appear on display. Adjust the set temperature for heating using the + and - buttons. The controller keeps a safety differential of at least 1 degree between Heating set point and Cool set point (Heat is always less than Cool). After selecting the heating set point, you cannot reduce the cooling set point less than the heating set point. Continue with the rest of the program Press the SELECT button again - PROGRAM 2 & START (flashing) will appear will appear on display. Press the + or - buttons and adjust the hours, minutes and temperature, the same way as in PROGRAM 1 Press the SELECT button again - PROGRAM 3 & START (flashing) will appear on display. Press the + or - buttons and adjust the hours, minutes and temperature, the same way as in PROGRAM 1 15

Press the SELECT button: PROGRAM 4 & START (flashing) will appear on display. Press the + or - buttons and adjust the hours, minutes and temperature, the same way as in PROGRAM 1 SEND will flash, press ON/SEND button to send the information to thermostat. PROGRAM (flashing) and SA (Saturday) will appear on display. Set programming for Saturday the same way as programming MON to FRI. SEND will flash; press the ON/SEND button to send the information to thermostat. PROGRAM (flashing) and SU (Sunday) will appear in display. Adjust the programming for Sunday the same way as programming MON to FRI. SEND will flash; press the ON/SEND button to send the information to the thermostat. The TIMER will flash; using the + or - buttons, Select TIMER ON or OFF. If you changed between TIMER ON (programmable) or OFF (non-programmable), SEND will flash. Press ON/SEND button to send the information to the thermostat. If you did not change between them, press the SELECT button to exit programming. 16