I-355 Corridor Master Plan Update

Similar documents
LOCAL DISPATCH AREA: ALARM SPECIAL/ CHANGE OF LEVEL ENGINES TRUCKS SQUADS EMS CHIEFS SPECIAL EQUIPMENT QUARTERS

The transportation system in a community is an

INTRODUCTION SECTION 1 FRAMEWORK FOR PLANNING IN ROMEOVILLE. DRAFT - FOR REVIEW PURPOSES ONLY Introduction 1

2.0 AREA PLANS. Lakeside Business District. Lakeside Business District Land Use Categories:

Planning Districts INTRODUCTION

SECTION UNIFIED DEVELOPMENT ORDINANCE SECTION Part 1 Ordinance. ARTICLE 1 Zoning Districts

General Location Annex, Rezone & Preliminary Plat Lansdowne Addition, Unit Three

THE PLANNING AREA 2.1 PLANNING AREA LOCATION

Selected Area Study. Vision Plan Draft

CITY OF COLWICH COMPREHENSIVE PLAN LAND USE LAND USE 1

EXECUTIVE SUMMARY DRAFT CHAPTER 1 INTRODUCTION EXECUTIVE SUMMARY

Gold Line Bus Rapid Transit Transit Oriented Development (BRTOD) Helmo Station Area Plan

124 Subarea Visions. Vision Plan. A. Nelessen Associates, INC I Visioning I Planning I Urban Design

DRAFT ROOSEVELT ROAD. District Recommendations. Figure 5.23 The Roosevelt Road Corridor

Town Center (part of the Comprehensive Plan)

A Plan for the Heart of the Region: Tukwila, WA

... the real city lives on... Character Area 5: LOWER WASHINGTON

Prosperity Hucks Area Plan. Transportation and Planning Committee May 11, 2015

Strategic Growth Area #1 Northampton Boulevard Corridor Area

Policies and Code Intent Sections Related to Town Center

Subarea 4 Indian Creek. Vision The combination of park networks and transportation amenities make Subarea 4 the greenest hub in the Corridor.

Section 3: Land Use M C H E N R Y K A N E. Figure 3.1: Potential Future Municipal Boundaries. Future Municipal Boundaries. County Land Use Plans

MODEL ACCESS MANAGEMENT PLAN MINNESOTA TRUNK HIGHWAY 7 COMPREHENSIVE PLAN AMENDMENT (HUTCHINSON SEGMENT)

NWI Wetland Public Waters Inventory Low Density Residential Medium Density Residential. High Density Residential. Public or Institutional

A P P E N D I X B - O P P O R T U N I T Y S I T E S

[PLANNING RATIONALE] For Site Plan Control and Lifting of Holding Zone By-Law 101 Champagne Avenue. May 23, 2014

IH35 Corridor Plan Amendment to the Comprehensive Plan

YONGE STEELES CORRIDOR SECONDARY PLAN. Young + Wright / IBI Group Architects Dillon Consulting Ltd. GHK International (Canada) Ltd.

PORT WHITBY COMMUNITY

EXISTING COMPREHENSIVE PLAN

LAND USE MEADOWS PLANNING AREA

Ten Mile Creek Planning Area

Former Rockcliffe Airbase Community Design Plan Guiding Design Vision and Principles December 4, 2013

Table of Contents. Elm Avenue Improvement Plan City of Waco, Texas. Introduction 1. Existing Context 1 Figure 1 2.

17.11 Establishment of Land Use Districts

Civic Center District

Welcome. Comprehensive Plan & Transportation Plan Open House November 7, 2012

SYRINGA VALLEY SPECIFIC PLAN NARRATIVE

Blue Line LRT Extension

KANATA CENTRUM 255 KANATA AVENUE OFFICIAL PLAN AMENDMENT ZONING BY-LAW AMENDMENT

LAND USE DESIGNATIONS AND ZONING CLASSIFICATIONS

4 LAND USE DESIGNATIONS

Land Use. Existing Land Use. Existing Land Use Categories. Faribault Comprehensive Plan 4-1

8 Future Land Use Plan

M E M O R A N D U M January 6, 2017

Brampton. Secondary Plan. Review. Bram West. A New Direction in Planning & Public Consultation

IH35 Corridor Plan Amendment to the Comprehensive Plan

Issues, Challenges & Opportunities

THE NEIGHBORHOOD TODAY

Development Agreement Public Meeting. June 26, 2013

Description of Preferred Alternative

FUTURE LAND USE & DEVELOPMENT

C. Westerly Creek Village & The Montview Corridor

and services The protection and conservation of environmentally significant and sensitive natural heritage features and functions.

APPENDIX C SPECIAL PLANNING AREAS

The lands identified as Residential Areas on Schedule A1, Urban Structure, represent the areas that provide for stable residential communities.

Mark-up of the effect of the proposed Bronte Village Growth Area OPA No.18 on the text of section 24, Bronte Village, of the Livable Oakville Plan

RESOLUTION NO R

Land Use. Hardware Street Vendor Mixed-Use

Isabel Neighborhood Plan: Alternatives

QUEEN-RIVER SECONDARY PLAN

CHARLES PUTMAN CHARLES PUTMAN AND ASSOCIATES, INC

CHAPTER 2: FUTURE LAND USE CONCEPTS

Harlem Avenue Corridor Plan: Corridor Planning Across Municipal Boundaries

Town Center. Block 5 Existing multifamily residential units are expected to remain.

4. Shape Transitions. 4. Shape Transitions

UNIVERSITY OF MICHIGAN:

Employment and Commercial Review Analysis of Policy Directions

Dwelling Units Max 12 dwelling units per acre/min 8 dwelling units per acre. Development Mix 80% non residential/20% residential

Glenborough at Easton Land Use Master Plan

Land Use Plan. Strategic Plan. CHAPTER SEVEN Proposed Land Use Plan. Fort Washington Area

PROTOTYPE DESIGN/INTRODUCTION

4 C OMMUNITY D ISTRICTS

WORK SESSION STAFF REPORT Work Session Item No. 2. Michael Grochala, Community Development Director

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: May 18, 2017

Comprehensive Plan. Village of Downers Grove. Adopted October 4, 2011 Updated 2015 Updated 2017 LAKE MICHIGAN

4.1 LAND USE AND PLANNING EXISTING CONDITIONS REGULATORY BACKGROUND LAND USES IN THE PLAN AREA SURROUNDING LAND USES

LAND USE & COMMUNITY DESIGN

Subarea 5 Southern Gateway. Vision. Mobility The proposed street network will create developable blocks that are scaled appropriately for the area.

To ensure that resources will be available to provide a consistent level of public services to the community.

9 th Street Sub Area Plan

Chapter 1 - General Design Guidelines CHAPTER 1 GENERAL DESIGN GUIDELINES

SOUTH NATOMAS COMMUNITY PLAN

SHEFFIELD PARK Paulding County, GA DRI #588

Existing Transportation System 5-1

CHAPTER 7: Transportation, Mobility and Circulation

burlington mobility hubs study Downtown Burlington Mobility Hub

Atlanta BeltLine Subarea 3 Master Plan Update

Regency Developments. Urban Design Brief. Holyrood DC2 Rezoning

WEST OAKLAND SPECIFIC PLAN PROJECT DESCRIPTION

Seneca Meadows. Block 4 Locate office, technology, and medical development adjacent to I Screen views of garage structures from I-270.

Be it enacted by the Town Board of the Town of Guilderland that the following new A (Transit Oriented Development (TOD) District) is adopted:

LAND USE OVERVIEW WHAT YOU WILL FIND IN THIS CHAPTER

Elm Fork Land Use. Trinity River Corridor Project Committee May 13, 2013

CITY OF WARRENVILLE SOUTHWEST DISTRICT PLAN MAY 25, 2016

Mitchell Ranch South MPUD Application for Master Planned Unit Development Approval Project Narrative. Introduction

Cobb County Design Guidelines Mableton Parkway & Veterans Memorial Highway Community Design Workshop January 12, 2017

Corridor Vision. 1Pursue Minnehaha-Hiawatha Community Works Project. Mission of Hennepin County Community Works Program

DRAFT ETC Master Plan. Appendix D Land Uses and Demographics

DRAFT MAJOR CORRIDORS 48 EAST BENCH MASTER PLAN

Transcription:

I- Corridor Master Plan Update February 19, 2014 prepared by

Lockport Regional Setting 88 Warrenville Lisle 88 Downers Grove Oak Brook 294 Hinsdale La Grange McCook Forest View 55 Summit Chicago 94 90 Naperville Woodridge Darien Willowbrook 55 Burr Ridge Hodgkins Willow Springs Bedford Park Burbank Bridgeview Hometown Hickory Hills Evergreen Park Oak Lawn 90 Bolingbrook Lemont Palos Hills 294 Palos Park Palos Heights Alsip Merrionette Park 57 Calumet Park Blue Island 94 I- Corridor Study Area Crestwood Plainfield Romeoville Homer Glen Orland Park Oak Forest Harvey Shorewood 55 Crest Hill Rockdale Lockport 80 Joliet New Lenox Orland Hills Mokena Frankfort Tinley Park 80 Matteson 57 Richton Park 294 Thornton Homewood Glenwood Flossmoor Chicago Heights South Chicago Heights 80 80 57 University Park Crete The I- Corridor is located along the s eastern boundary within Will County, Illinois, approximately 35 miles southwest of Downtown Chicago and 5 miles from Joliet. The is well-positioned within the Chicagoland area, having excellent access to the region s transportation network, including I-, I-88, I-55, I-80, Metra, and Midway Airport. Incorporated in 1830, the City has a rich heritage as one of Chicago s early canal towns and is part of the 120 mile long Illinois & Michigan Canal National Heritage Corridor. The City s population has been growing steadily over the past decade to a current population of approximately 25,046. As it passes through Lockport, the I- corridor includes a mix of residential, commercial, industrial, institutional uses, and also a considerable amount of vacant/undeveloped land. As a key new section of the region s highway system, connecting I-55 and I-80, the I- Study Area is poised for an increase in development and land use intensity. 1

Lockport Land Use Plan AV E. 143RD ST. AR CH ER 171 151ST ST. This figure illustrates the general land use recommendations of the I- Corridor Master Plan Update. The Plan seeks to balance compatibility with existing uses and the need to provide market viable land use and development scenarios. Although most areas have a specific land use designation, there are a few areas that could appropriately accommodate a range of uses and are therefore designated to provide additional flexibility. More detailed commentary regarding land use and development considerations for the different areas along the Corridor is provided in the following sub-area framework sections of this Plan Update. Homer Glen 159TH ST. 7 163RD ST. 7TH ST. Legend Study Area Boundary Creek / Drainage Lockport City Limits Floodplain 167TH ST. Land Use Residential Office / Business Park Residential / Potential Conversion Public / Semi-Public Commercial Light Industrial / Business Park Commercial / Flexible Parks / Open Space BRUCE RD. (175TH) Market Flexibility (Refer to Subarea Plans for designated uses) New Lenox 2

Land Use & Development Residential As presented in the Land Use Plan, the residential classification includes single-family attached, singlefamily detached and multi-family residential units. The Sub-Area Framework Plans identify the desirable mix of residential units for each area in more detail. Single-family residential uses are recommended for key locations within the Corridor that essentially extend the already existing single-family residential character of certain sections of the Study Area, or are properties of desirable size, shape, and location for single-family developments. Single-family attached and multi-family developments are primarily used to transition from non-residential areas to single-family residential areas. The Plan also anticipates the development of some age-restricted/age-targeted areas, which could provide an attractive mix of single-family attached and multifamily residential uses. Residential uses could also be considered appropriate for some of the areas designated for market flexibility and commercial/flexible Residential/Potential Conversion The existing properties in this classification are single-family detached homes on large lots that are likely to remain. However, in the future, if these properties were to redevelop, future uses should be compatible with the types of commercial development designated for adjacent areas. Commercial/Flexible Properties designated as commercial/flexible are located along 143rd Street between Archer Avenue and I-. These areas prioritize commercial development along the 143rd Street and Archer Road frontages, but can also possibly accommodate compatible multi-family and single-family attached residential, office, and business park uses on the interior portions of the sites. Frontage commercial could include retail, restaurant, office, entertainment, and more. Commercial uses are intended to generally be located within or near a 1/2 mile radius of the I- interchanges and along major arterials. Market Flexibility Four areas are designated as market flexibility the area northwest of 151st and I-, the area northwest of 159th and I-, the area northwest of 163rd and I-, and a portion of the area southwest of 163rd and I-. These areas can appropriately accommodate different land use designations and are therefore intended to provide increased flexibility. The area northwest of 159th and I- could appropriately accommodate office, business park, and/or residential uses (including single-family detached, singlefamily attached, and multi-family) and the area northwest of 163rd and I- could be considered appropriate for light industrial, business park, office, and/or commercial uses, but not residential. The area along 151st can range from residential to light industrial/business park, and the area southwest of 163rd and I- can accommodate residential and commercial uses. Commercial Properties in this classification are ideally suited for a variety of commercial uses, including retail, restaurant, service, office, entertainment, hotel, and more. Some commercial uses are better suited for certain areas, as described in the Land Use Framework Plans. Commercial uses are generally located within or near a 1/2 mile radius of the I- interchanges and along major arterials. Public/Semi Public Four sites are designated in this Plan as public/semi-public and all accommodate existing facilities, including two fire stations, a water tank, and a ComEd facility. No new public/semi-public uses or facilities are designated in the Plan. Office/Business Park In general, Office/ Business Park uses occupy areas that lack sufficient commercial frontage, access, and visibility. Uses that are appropriate for these properties may include office campus, employment centers, incubator businesses, research facilities, and more, and may also include non-traditional office uses such as gymnastics facilities, martial arts studios, or other athletic uses that require high ceilings and more affordable, large leasable spaces. Uses generating significant truck traffic should be discouraged for these areas. These areas should be developed in a campus setting with attractive landscaping and grounds. Light Industrial Appropriate uses in this classification include uses such as warehouse/distribution facilities, office space, employment centers, research facilities, and more traditional light industrial park uses, some of which may generate significant truck traffic from distribution services and general fleet vehicles. These higher impact uses are generally located in key locations within the Corridor that are near existing and future interchanges with I-. Appropriate screening and buffering are important features for future development in this classification. Parks/Open Space This designation is represented by open undeveloped land that can include parks and areas of natural environment. Although only a few such properties are designated as parks/ open space within the corridor, there exist several areas of flood plain, creek/riparian corridors, new buffer areas, mature tree stands, and more that are identified for protection, enhancement, and incorporation into future development. Collectively, these environmental features and the areas that contain them will help to shape the overall character of the area. 3

4

Lockport 1- Subareas AV E. This figure identifies the three subareas that have been created for purposes of illustrating more detailed analysis for each parcel within the Corridor Study Area. The following pages illustrate land use and development framework plans for each of these three subareas. Homer Glen AR CH ER 143RD ST. 143rd Street Subarea 171 151ST ST. 159TH ST. 7 159th Street Subarea 163RD ST. 7TH ST. 167TH ST. Study Area Boundary Creek / Drainage Lockport City Limits Floodplain Subareas 143rd Street Subarea Legend Bruce Road Subarea 159th Street Subarea Bruce Road Subarea BRUCE RD. (175TH) New Lenox 5

Lockport 143rd Street Subarea The 143rd Street Sub-Area extends from the northern end of the study area south to 151st Street. The Land Use Framework Plan for the 143rd Street Sub-Area focuses on establishing a retail/commercial node at the intersection of 143rd Street, Archer Avenue, and I-, with light industrial and business park uses in the other portions of the sub-area. The commercial node area prioritizes commercial uses fronting the major roadways and possibly including other residential, office, and business uses in the more interior portions of the sites. This commercial development opportunity will have a different character from the big box retail at 159th Street. This commercial node, with excellent visibility and access, can accommodate a mix of retail, hotel, entertainment, and restaurant uses. An existing single-family residential area also exists at the eastern edge of the sub-area. 1/2 Mile Radius 1 Homer Glen 143RD ST. ARCHER AVE. 2 171 4 3 151ST ST. Legend Study Area Boundary Lockport City Limits Creek / Drainage Floodplain Land Use Residential Commercial / Flexible Office / Business Park Market Flexibility (Residential, Commercial, Office / Business Park, Light 6 Industrial / Business Park) Key Roadways / Connections 1/2 Mile Radius from I- Interchange Buffering / Screening Public / Semi-Public Light Industrial / Business Park Parks / Open Space

1 Commercial/Flexible With frontage 3 Light Industrial, Office/Business Park, on both 143rd and Archer Avenue, and adjacency/proximity to I- and the 143rd Street interchange, this site is ideally suited for commercial/retail use, but can also accommodate other compatible uses such as multi-family residential, office, and other business uses on the interior/ non-frontage portions of the site. The overall size and geometry of the site can accommodate a variety of retail development, from standalone single-tenant uses to lifestyle center type developments. This area is also well situated for hotel, entertainment, and restaurant uses, with its easy access and visibility form 143rd Street, Archer Avenue, and I-. Service station uses are also well suited for this location. Any proposed uses other than commercial should be compatible with commercial uses and should not be located along Residential and Market Flexibility This area closely mirrors the land use strategy that exists across I- to the east. The area is primarily designated for light industrial and business park uses. Because some established residential uses exist adjacent to the area, any non-residential use in the area should be adequately screened and buffered from adjacent residential uses. The area located along 151st Street adjacent to the existing residential should also be designated as residential, in order to provide greater development compatibility. The area south of the creek should be designated as Market Flexibility and can accommodate a range of uses including residential, commercial, office, and business park/light industrial. Any development should be designed to mitigate any impact on the adjacent residential areas. the frontages of Archer and 143rd. 4 Light Industrial/Business Park/Distribution/Warehouse 2 Commercial/Flexible and Light This site has been Industrial/Business Park With frontage on both 143rd and Archer Avenue, and adjacency/proximity to I- and the 143rd Street interchange, this site is ideally suited for commercial/retail use along the 143rd Street and Archer Road frontages, but can also accommodate other compatible uses such as multi-family residential, office, and other business uses on the interior/ non-frontage portions of the site. The overall size and geometry of the site can accommodate a variety of retail, restaurant, office and services uses. Service station approved for a warehouse/distribution facility and parts of the development are already constructed. An existing singlefamily neighborhood is located within a portion of the northern segment of this site. It is expected that this residential use will remain, however, in the future, as the site surrounding the residential use is developed, these properties should be considered for redevelopment into non-residential uses that are compatible with the surrounding light industrial/business park/distribution/warehouse uses. uses are also well suited for this location. Any proposed uses other than commercial should be compatible with commercial uses and should not be located along the frontages of Archer and 143rd. 7

Lockport 159th Street Subarea The Land Use Framework Plan for the 159th Street Subarea builds upon the big box retail core that is existing and currently being developed. The Subarea is situated around the 159th Street/I- interchange and has excellent visibility and access. The sub-area extends form 151st Street on the north to 163rd Street on the south. The 159th Street Subarea should be intensely developed as the Study Area s primary commercial node, accommodating a variety of retail and service uses. Other uses in the sub-area include residential, business park, light industrial, and open space. Legend 151ST ST. Key Roadway / Extention Lockport City Limits Street / Network Connection Creek / Drainage Buffering / Screening Floodplain Key Potential Commercial Development Opportunity 1/2 Mile Radius from I- Interchange 5 1/2 Mi le R a Study Area Boundary Land Use 6 Residential Office / Business Park Residential / Potential Conversion Public / Semi-Public Commercial Light Industrial / Business Park Market Flexibility Parks / Open Space s diu 7 8 9 159TH ST. 7 15 10 14 18 11 12 17 13 16 7TH ST. 163RD ST. 19 20 21 22 167TH ST. 8

5 Open Space This area is designated 13 Market Flexibility Due to the site s as natural open space. location, orientation, size, geometry, visibility, and access issues, it is a challenging 6 Office/Business Park This area site to develop. With its orienta- should be considered for office/business park uses and be more of a transition area between the more intense light industrial development to the north and the designated commercial area to the south. Uses generating significant truck traffic should be discouraged in this area. tion along I-, it s relatively narrow frontage, and it adjacency to industrially designated property, the site should be considered for light industrial, business park, and office uses. The possibility also exists for destination retail due to the site s prominent visibility from I-. 7 Commercial/Retail The area should be developed for retail/commercial uses (possibly including office uses) as one of the key commercial corners of the 159th Street & Gougar Road intersection. As a core retail/commercial components of the corridor, all four corners of the Gougar Road/159th Street intersection should be developed for commercial/retail uses. 8 Market Flexibility Due to the site s location, orientation, geometry, visibility, and access issues, it is not conducive to retail development or light industrial uses. That being said, several other types of uses could be appropriately developed on the site in a manner compatible with surrounding uses. Office, business park, and residential uses should all be considered appropriate. Uses generating significant truck traffic should be discouraged in this busy commercial core area and new development should be appropriately buffered from adjacent residential areas. 9 Retail/Commercial This area has highly visible and accessible frontage along 159th Street should be developed for retail, restaurant, office and other commercial uses, compatible with the development adjacent to the south along the south side of 159th Street. Development of this site should incorporate coordinated access to Site 8, adjacent to the east. 10 Retail/Commercial Lockport Square retail center containing a mix of big box, mid box, and smaller retail tenants. This area is a key component of the retail commercial core for the I- Corridor. 11 Light Industrial/Business Park Existing Panduit Corporation with potential future expansion. 12 Market Flexibility With its location behind the Lockport Square shopping center, and adjacent to the Panduit property, this site along the north side of 163rd Street can appropriately accommodate a wide variety of uses, including light industrial, business park, and office uses, and possibility destination or big box retail. 14 Retail/Commercial This area is an important component of the 159th Street/ Gougar Road intersection, providing the southwest corner of the intersection. The northern portion of the site should be more intensely developed, preferably for retail uses, with the southern portions possibly developed for less intense uses. The existing ComEd sub-station facility should be relocated to accommodate redevelopment of this key intersection. This area will likely require significant property assembly in order to accommodate viable commercial development. 15 Retail/Commercial This area is an important component of the 159th Street/ Gougar Road intersection, providing a significant development opportunity on the southeast corner of the intersection. The site should be developed for retail uses, with other commercial and entertainment uses considered appropriate. 16 Retail/Commercial This small property should be considered for retail/ commercial uses, consistent with the area adjacent to the west, across Gougar Road. 17 Residential/Possible Conversion - This area consists of well-established, single-family homes on relatively large lots that will likely remain. However, if this area were to redevelop in the future, the site should be developed with uses compatible with adjacent Sites 15 and 16 (retail/commercial) and Site 18 (retail/commercial and residential). 18 Retail/Commercial and Residential The properties fronting along 159th Street should be developed for retail/commercial uses. The area south of the frontage properties should be developed for a mix of residential uses. Higher density residential uses such as condominiums and townhomes should be considered as a buffer adjacent to commercial uses, with lower density residential (townhomes and singlefamily detached) uses being incorporated further to the south. Ideally, commercial development along 159th Street would be of a depth to match the commercial properties designated in the plan to the west. 19 Residential and Market Flexibility The western portion of the site is designated for residential use and should be development in a manner compatible with and consistent with the character of the residential development to the west. The eastern portion of the site along I- and Gougar Road is designated for Market Flexibility, which includes residential and commercial uses for this area. 20 Light Industrial/Business Park With its location adjacent to I- and lacking any good commercial frontage opportunity, this site is well suited for light industrial/business park uses. Uses generating large amounts of truck traffic should be discouraged. 21 Office/Business Park This area should be developed for office/business park uses. Warehouse/distribution uses, and other uses generating significant truck traffic, should be discouraged. A public street connecting 167th Street and 163rd Street should be provided as part of the development of this site, possibly including a connection to the site adjacent to the west. The creek/floodplain area running along the eastern edge should be enhanced as a buffer to the residential areas designated to the east. 22 Residential This area should be developed for residential uses, primarily of single-family residential uses, but could also incorporate areas of townhomes. 9

Lockport Bruce Road Subarea The Land Use Framework Plan for the Bruce Road Sub-Area anticipates the construction of the future Bruce Road interchange at I-, and provides a mix of land uses to capitalize on the future improvements. Over time, the new interchange, Bruce Road improvements, and a new bridge over the Des Plaines River will dramatically alter the character of the Bruce Road corridor. The subarea includes retail/commercial, residential, light industrial/business park, and office/business park uses. 167TH ST. 23 24 1/2 Mi le 25 s diu Ra 27 26 Homer Glen BRUCE RD. (175TH) 28 29 30 New Lenox Legend Study Area Boundary Key Roadway / Extention Lockport City Limits Street / Network Connection Creek / Drainage Buffering / Screening Floodplain Toll Authority Facility 1/2 Mile Radius from I- Interchange Land Use Residential Commercial Office / Business Park Light Industrial / Business Park Parks / Open Space Public / Semi-Public 10

23 Office/Business Park This relatively small site sits just south of the Commonwealth Edison property and substation. The site is relatively isolated and is well-suited for a range of office/ business park uses, consistent with the business park area to the east. 24 Office/Business Park This existing business park has a wide range of existing and proposed uses, including a sports/entertainment facility, public works facility, transitional care facility, manufacturing business, and dentist office. Future build out of the business park should continue to accommodate a wide range of uses, but not uses that generate significant amounts of truck traffic. 25 Residential With single-family residential to the north and west (across Gougar Road, and open space to the south, this site is well situated for single-family detached residential development. The floodplain/wetland areas that run through the site should be sensitively incorporated as green space into any development plans. 26 Residential Due to the geometry and location of this site, and the fact that it is surrounded by open space, this site should be considered for single-family or townhouse development, similar in density to nearby residential areas. The floodplain/ wetland areas that run through the property should be sensitively incorporated as green space into any development plans. 27 Residential and Retail/ Commercial This site should be considered for residential development, including a mixture of single-family detached and single-family-attached dwellings. Given the size and location of the site, consideration should also be given to accommodating and age-targeted or age restricted development, possibly including multifamily components. The portion of the site fronting Bruce Road should be designated for commercial use, taking advantage of future Bruce Road improvements, traffic volumes, and I- interchange. 28 Retail Commercial In anticipation of a future Bruce Road/I- interchange and future upgrades and intensification of Bruce Road, this site should be designated for retail/commercial use. Any non-residential development and activity must be adequately screened and buffered from adjacent existing residential areas. 29 Retail/Commercial and Light Industrial/Business Park The northern portion of the site along Gougar and Bruce Roads should be designated for retail/commercial use, taking advantage of Bruce Road visibility, future improvements and traffic volumes, and the future I- interchange. That portion of the site that extends southward along I- lacks visibility and convenient frontage. This southern area is well suited for light industrial/business park uses. 30 Retail/Commercial and Light Industrial/Business Park The northern portion of the site fronting Bruce Road should be designated for retail/commercial use, taking advantage of Bruce Road visibility, future improvements and traffic volumes, and the future I- interchange. The portion of the site that extends southward along I- lacks visibility and convenient frontage, and would be adjacent to future interchange ramps, making the site undesirable for residential use. This southern area is well suited for light industrial/business park uses, with convenient access to I-. Any non-residential development on the site should be adequately screened and buffered from adjacent residential areas. 11