EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Similar documents
EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

User s Manual YTA610 and YTA710 NEPSI Certification

EXPLOSION PROTECTION

Inductive slot sensor

srra IECEx Certificate of Conformity 2-otI - 03 *07 csa Broup certif CÅr 0f'l TopWox lnc. Gunent 2019{,3-07

Technical Data. General specifications. Rated operating distance s n 5 mm

OPTIWAVE X500 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

IECEx Certificate of Conformity

Fixed Gas Detection System/Meridian CERTIFICATION

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate of Compliance

IECEx Certificate of Conformity

Certificate of Compliance

Guide for hazardous areas

IECEx Certificate of Conform ity

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

4) Intrinsic Safety Certification

IECEx Certificate of Conformity

ATEX Explained A brief Introduction

IECEx Certificate of Conformity

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ ) (Attachment Ⅰ) Attachm

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Safety instructions VEGAPULS 64

Manual Power relay SR853

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Technical Data. Dimensions

Certificate of Compliance

IECEx Certificate of Conformity

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Approvals, Certificates and Conditions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Ar-Mite TM Low Flow Armored Flowmeter

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Electrical Installations Design, Selection, Erection and Inspection

Annubar Flowmeter Series

INSTRUCTION MANUAL (ATEX / IECEx)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

IECEx Certificate of Conformity

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

IECEx Certificate of Conformity

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

UL HAZARDOUS LOCATIONS SERVICES

OPTIBAR P 1010/2010 C Supplementary instructions

Rosemount 8600 Series Vortex Flowmeter. Quick Start Guide , Rev EB April 2018

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

srra, of Conformity IECEx Gert f cate ?-ot,b

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Indoor/outdoor resistance thermometer Model TR60

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Certification Supplement Manual

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Technical Data. Dimensions

IECEx Certificate of Conformity

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

INSTRUCTION MANUAL (ATEX)

IECEx Certificate of Conformity

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

Rosemount 3051 Pressure Transmitter

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Safety instructions VEGABAR 81, 82, 83, 86, 87

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Beamex. Calibration White Paper. Calibration in hazardous areas

official distributor of Newson Gale Ltd.

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

IECEx Certificate of Conformity

Beamex Calibration White Paper. Calibration in hazardous areas

Rosemount 644 Temperature Transmitter

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Integrated Solutions Low Voltage Systems

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

Quick Start Guide For the

Certificate of Compliance

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Transcription:

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ15.1138X Manufacturer: Product: Model Specification: Anti-explosion Mark: Topworx Inc. (Address: 3300 Fern Valley Road, Louisville, Kentucky 40213, USA) Valve Position Indicators TVA, TVF, TVH and TVL series Ex ia IIC /T6 Gb, Ex tb IIIC T75ºC Db, IP64/66/68 Product standard / Drawing No. CERT-ES-04334-1 Rev.11 After examining the drawings and technical documents as well as sample testing, it has been confirmed that the abovementioned products are in compliance with GB 3836.1-2010, GB 3836.4-2010, GB 3836.20-2010, and IEC 60079-31:2008 standards, and this certificate is hereby issued. This certificate is valid from May 22, 2015 to May 21, 2020 Remarks: 1. Please refer to the attachment of this certificate for safety precautions. 2. Please refer to the attachment of this certificate for specific model specifications. 3. Intrinsic electrical parameter is specified in the attachment to this certificate. 4. This certificate is also applicable to products with the same model number manufactured by Emerson Machinery Equipment (Shenzhen) Co., Ltd. (Address: Bao Heng Technology Industry Park, Liu Xian 1 st Road, District 68, Bao an District, Shenzhen) and by Emerson Process Management Magyarorszag Kft. (Address: 8000 Szekesfehervar, Holland Fasor 6, Hungary) Director [Signature - illegible] Date of Issue May 22, 2015 [Seal ] This certificate is valid only for products matching the approved documentation and sample. Address: 103 Cao Bao Road, http://www.nepsi.org.cn Tel: +86 21 64368180 Shanghai 200233, China Email: info@nepsi.org.cn Fax: +86 21 64844580 Edition 05

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Cert. No. GYJ15.1138X This is to certify that the product Valve Position Indicators manufactured by Topworx Inc. which model is (Address: 3300 Fern Valley Road, Louisville, Kentucky 40213, USA) TVA, TVF, TVH, TVL series Ex marking Ex ia IIC /T6 Gb, Ex tb IIIC T75ºC Db, IP64/66/68 product standard / drawing number CERT-ES-04334-1 Rev.11 has been inspected and certified by NEPSI, and that it conforms to GB 3836.1-2010, GB 3836.4-2010, GB 3836-20-2010, IEC 60079-31:2008 This approval shall remain in force until May 21, 2020 Remarks 1. Conditions for safe use are specified in the attachment to this certificate. 2. Safe parameters specified in the attachment to this certificate. 3. Intrinsic safety parameter specified in the attachment to this certificate. 4. This certificate is also applicable for the product with the same type manufactured by Emerson Machinery Equipment (Shenzhen) Co., Ltd. (Address: Bao Heng Technology Industry Park, Liu Xian 1st Road, District 68, Bao an District, Shenzhen, P.R. China) and Emerson Process Management Magyarorszag Kft. (Address: 8000 Szekesfehervar, Holland Fasor 6, Hungary). Director [Signature - illegible] Issued Date May 22, 2015 [Seal ] This certificate is valid for products compatible with the documents and samples approved by NEPSI. 103 Cao Bao Road http://www.nepsi.org.cn Tel: +86 21 64368180 Shanghai 200233, China Email: info@nepsi.org.cn Fax: +86 21 64844580

(GYJ15.1138X) (Attachment I) GYJ15.1138X Explosion Protection Certificate of Conformity Attachment I After inspection by the Explosion Protection and Safety of Instrumentation (NEPSI), the TVA, TVF, TVH and TVL series of valve position indicators produced by Topworx Inc., Emerson Machinery Equipment (Shenzhen) Co., Ltd. and Emerson Process Management Magyarorszag Kft., have been found to be in compliance with the following standards: GB3836.1-2010 Explosive Atmosphere Part 1: Equipment - General Requirements GB3836.4-2010 Explosive Atmosphere Part 4: Equipment Protected by Explosion Protection Type i GB3836.20-2010 Explosive Atmosphere Part 20: Equipment whose Equipment Protection Level (EPL) is Ga Level IEC 60079-31:2008 Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure t The anti-explosion mark of TVA, TVF series valve position indicators is:ex ia IIC /T6 Gb; the anti-explosion mark of TVH, TVL series valve position indicators is Ex ia IIC /T6 Gb, Ex tb IIIC T75ºC, IP64/66/68. The Explosion Protection Certificate of Conformity number is GYJ15.1138X. This certificate recognizes products with the specific model number: TVa-b c 0 d e f g h l j k Where: a indicates enclosure material; can be A, F, H or L; b indicates main line and sensor information; can be L, M, P, R, T, K, X, E or N; c indicates number of switches; can be 1~4; d e f g h l j k are parameters not related to explosion protection. The relationship between optional components and ambient temperature range for use as well as temperature groups is as follows: Optional Components Product Name Code Model No. Note name Mechanical Switch K V7 Simple equipment Micro/Limit Switch M VS10N001C2 Simple equipment Reed Switch P HSR-V933 Simple equipment Reed Switch R LV-ELE 145 Simple equipment Go Switch L 35 series Simple equipment DPDT Micro Switch T Cherry Burrell E19 or Simple equipment ITW DPDT-ZZ #26-804 Ambient for use Gas Group Dust Group ~+55 ºC T6 Page 1 of 3

(GYJ15.1138X) (Attachment I) ASCO Solenoid Valve Module 1/2 3021..IA IECEx INE 10.0002X -40 ºC ~+56 ºC IFM Electronic Inductive Proximity Switch Slot-type Initiator Cuboidal Inductive- Type Sensor Cylindrical Inductive Sensor N N*50**, N95001&K15030 (power supply form 1, 2 or 3) IECEx BVS 06.0003 N SJ, SC IECEx TUN 04.0016X E NJ2 V3 N (power supply form 1, 2 or 3) -25 ºC ~+42 ºC ~+47 ºC ~+56 ºC IECEx PTB 11.0021X Other models (power supply form 1, 2 or 3) ~+35 ºC N NC, NJ (power supply form 1, 2 or 3) PTB 00ATEX2048X ~+39 ºC SN Sensor TopWorx 4~20mA Transmitter Module and Associated Potentiometer Turck 2-wire Proximity Sensor N NC, SJ (power supply form 1, 2 or 3) X / PTB 00ATEX2049X IECEx SIR L2.0076U N Y1 type IECEx KEM 06.0036X ~+40 ºC -40 ºC ~+52 ºC -25 ºC ~+42 ºC I. Specific Conditions for Safe Use of Product If the certificate number ends with a X, it indicates that the product is subject to special conditions for safe use: 1. When a simple switch is used in the valve position indicator, it must meet the following intrinsically safe parameters: Ui=30V, li=200ma, Pi=0.72W () /0.34W (T6), Ci=0, Li=0. 2. When the valve position indicator uses other components, its intrinsically safe parameters can be obtained by referring to the explosion protection certificate of conformity for the relevant components; 3. The 4~20mA loop circuit and various optional components (switches, sensors, valves, etc.) should be treated as different intrinsically safe circuits; 4. The installation method must be able to prevent the danger of ignition caused by impact or friction. Page 2 of 3

(GYJ15.1138X) (Attachment I) II. Safety Precaution for Use of Product 1. When the valve position indicator incorporates a 4~20mA transmitter module, the output terminal of the transmitter should be connected to a Novotechnic WAL305 potentiometer, and no more than two switches are permitted. This module cannot be used for TVA and TVF casing. 2. TVL and TVH can meet the requirements of IP66/68 only when fitted with a Spec Seals S50440A silicon O-ring; when it uses Parker S7395-60 silicon O-ring, its casing protection level is IP64; 3. To form an intrinsically safe explosion protection system for use in an explosive gas atmosphere, it must be used with certified explosion protection ancillary equipment. 4. When this product is used in a dusty environment, a cable entry device or sealing component that has passed the inspection of the State s designated testing laboratories and that is compatible with product dust anti-explosion mark with casing protection grade of IP64/66/68, and thread specification of 1/2NPT, 3/4NPT, M16x1.5 or M20x1.5 must be used for the cable entry point, and redundant cable inlets must be effectively sealed with sealing components. 5. To prevent damage, the user should not replace parts by themselves, and should work with the product manufacturer to jointly resolve malfunctions that occur during operation. 6. When this product is used onsite, its surface should be cleaned regularly and the thickness of dust accumulation should not exceed 5mm. 7. The installation, use and maintenance of this product shall comply with the relevant provisions in the product manuals, GB3836.13-2013 Explosive Atmosphere Part 13: Repair, Inspection and Maintenance, Restoration, and Renovation of Equipment, GB3836.15-2000 Electrical Equipment Used in Explosive Gas Atmosphere Part 15: Electrical Installation at Hazardous Sites (Except Coal Mines), GB3836.16-2006 Electrical Equipment Used in Explosive Gas Atmosphere Part 16: Inspection and Maintenance of Electrical Equipment (Except Coal Mines), GB50257-1996 Electrical Equipment Construction and Acceptance Standards for Electrical Equipment Installation in Dangerous, Explosive and Fire Hazard Atmosphere, GB15577-2007 Safety Regulations on Dust Explosion Protection, and GB12476.2-2010 Electrical Equipment Used in Flammable Dust Atmosphere Part 2: Selection of Model and Installation. III. Responsibilities of the Manufacturer: 1. The manufacturer must incorporate the special requirements and safety precautions mentioned above into the product manual; 2. The manufacturer must manufacture the product in strict compliance with the documentation approved by NEPSI; 3. The product nameplate must at least include the following: a) NEPSI Approval Label (please refer to the Explosion Protection Certificate of Conformity) b) Product Explosion Protection Mark c) Certificate Number of the Explosion Protection Certificate of Conformity d) Ambient temperature for use e) Intrinsically safe parameters May 22, 2015 [Seal ] Page 3 of 3